Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED FL_Metshield Peel n Stick_1225
1/6/2021 Florida Building Code Online Business & iYl „ tIF _ ProfessionalRegulation r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr �fl -lamProduct Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL16342-R3 SFCRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Drexel Metals,Inc. Address/Phone/Email 204 Railroad Drive Ivyland, PA 18974 (502) 303-1511 jshumate@drexmet.com Authorized Signature Jason Shumate jshumate@drexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2025 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL16342 R3 COI DRX13004.3 2020 FBC Eval MetShield final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJBMjgUlj3N8DFHbJ4A60SANVVVZgk6Ewtf9QdMIHXpw%3d%3d 1/2 1/6/2021 Florida Building Code Online Date Submitted 08/09/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/24/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 16342.1 MetShield ASTM D 1970 self-adhering roofing underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL16342 R3 II DRX13004.3 2020 FBC Eval MetShield Approved for use outside HVHZ:Yes fina1.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use Evaluation Reports FL16342 R3 AE DRX13004.3 2020 FBC Eval MetShield f[nal.pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: © 4L] ® Kid Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJBMjgUlj3N8DFHbJ4A60SANVVVZgk6Ewtf9QdMIHXpw%3d%3d 2/2 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: DREXEL METALS, INC. Issued August 9, 2020 1234 Gardiner Lane Louisville, KY 40213 (502)716-7143 www.drexmet.com Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: U nderlayments Code Sections: 1507.1.1, 1507.2.4 Properties: Physical properties REFERENCES Entity Report No. Standard Year TrinityJERD(TST6049) C41280.10.12 ASTM D 1970 2015a ICC-ES(EVL2396) ESR-2206 ASTM D 1970 2015a PRODUCT DESCRIPTION AND APPLICATION MetShield MetShield is a coated-polyolefin-composite film surfaced, self-adhered ASTM D 1970 underlayment for use on steep slope roofs. Deck Type: Solid or closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Min. slope: In accordance with FBC requirements Attachment method: Underlayment shall be attached in accordance with the FBC Section 1507.1.1, Table 1507.1.1.1 and manufacturer's installation instructions. Min. application temperature: 40°F. Contact the manufacturer when installing at temperatures below 40°F. Allowable roof coverings: Permitted to be used as prescribed in FBC Table 1507.1.1.1 with mechanically fastened roof coverings. DRX13004.3 FL16342-R3 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK DREXEL METALS, INC. MetShield TECHNICAL SERVICES, LLC LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) MetShield may be used as described in other current FBC product approval documents. 7) MetShield shall not be used with adhered tile roof coverings nor installed over existing roof coverings. 8) MetShield shall be exposed on the roof deck for a maximum duration of 30 days. 9) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer. G�PaY" , 2020.08.09 ••.��GENSF.Fs 12:30:46 No 74021 o•,,.Ys_. aP—t -04'00' '. STATE OF 44/ 0 Zachary R. Priest, P.E. % T••.;c� P.'��� Florida Registration No. 74021 �i�s R � � . C? Organization No.ANE9641 �0 N A� CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT DRX13004.3 FL16342-R3 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.