Loading...
HomeMy WebLinkAboutENERGY CALCFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CAUSLEY RESIDENCE Builder Name: DON HINKLE CONSTRUCTION Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: RAY AND AMI CAUSLEY Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2543.7 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2249.70 ft2 b. Frame - Wood, Adjacent R=11.0 294.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2545.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2545.00 ft= 6. Conditioned floor area above grade (ft2) 2545 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(314.8 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 200 a. U-Factor: Sgl, U=0.65 314.78 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13 Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.0 SEER:17.00 c. U-Factor: N/A ft2 SHGC: ft Area Weighted Average Overhang Depth: 8.738 . 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap: 1 gallons 9. Floor Types (2545.0 sqft.) Insulation Area EF:0.900 a. Slab -On -Grade Edge Insulation R=0.0 2545.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.124 Total Proposed Modified Loads: 73.71 PASS Total Baseline Loads: 78.24 1 hereby certify that the plans and specifications covered by Review of the plans and S7,42, this calculation are in mpliance with the Florida Energy specifications covered by this Code. calculation indicates compliance � yai` �„ ' •��� 0 with the Florida Energy Code rnrr. �•, :;:: „ O PREPARED BY: Before construction is completed DATE: 4-27-2021 this building will be inspected for a compliance with Section 553,908 e ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Co COD yyg'l4� OWNER/AGEN BUILDING OFFICIAL: _ DATE: DATE: _..._ -. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CAUSLEY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2545 Lot # Owner Name: RAY AND AMI CAUSLEY Total Stories: 1 Block/Subdh4sion: # of Units: 1 Worst Case: No PlatBook: Builder Name: DON HINKLE CONSTRUCTI Rotate Angle: 0 Street: TREE TOP TRAIL Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2545 26926.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 296 3048.8 No 0 1 1 Yes Yes Yes 2 M BATH 156 1451 No 0 1 Yes Yes Yes 3 M WIC 84 781.2 No 0 1 No Yes Yes 4 M TOILET 32 297.6 No 0 1 Yes Yes Yes 5 FOYER/LIVING RM 380 5320 No 0 1 Yes Yes Yes 6 DINING RM 180 2520 No 0 1 Yes Yes Yes 7 KITCHEN 300 2790 Yes 0 1 Yes Yes Yes 8 HALLWAY 60 558 No 0 1 No Yes Yes 9 LAUNDRY RM 216 2009 No 0 1 Yes Yes Yes 10 BEDROOM 3 156 1450.8 No 0 1 1 Yes Yes Yes 11 CLST 3 16 148.8 No 0 1 Yes Yes Yes 12 BATH 2 72 669.6 No 0 1 Yes Yes Yes 13 CLST 2 16 148.8 No 0 1 Yes Yes Yes 14 BEDROOM 2 168 1562.4 No 0 1 1 Yes Yes Yes 15 HALL 52 483.6 No 0 1 No Yes Yes 16 FAMILY RM 330 3399 No 0 1 Yes Yes Yes 17 CABANA BATH 31 288 No 0 1 Yes Yes Yes 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 35 ft 296 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 2O.9 ft 156 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 1 ft 84 ft' ---- 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 12 ft 32 ft' ---- 1 0 0 5 Slab -On -Grade Edge Insulation FOYER/LIVING R 20 ft 380 ft' ---- 1 0 0 6 Slab -On -Grade Edge Insulation DINING RM 12 ft 180 ft2 ---- 1 0 0 7Slab-On-Grade Edge Insulation KITCHEN 4 ft 300 ft' ---- 1 0 0 8 Slab -On -Grade Edge Insulation HALLWAY 1 ft 60 ft' ---- 1 0 0 9Slab-On-Grade Edge Insulation LAUNDRY RM 9 ft 216 ft' ---- 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 156 ft' _--- 1 0 0 11SIab-On-Grade Edge Insulation CLST 3 2 ft 16 ft' ---- 1 0 0 12SIab-On-Grade Edge Insulation BATH 2 9 ft 72 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation CLST 2 2 ft 16 ft' ---- 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 20 ft 168 ft' ---- 1 0 0 15SIab-On-Grade Edge Insulation HALL 1 ft 52 ft' ---- 1 0 0 16SIab-On-Grade Edge Insulation FAMILY RM 40 ft 330 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation CABANA BATH 18 ft 31 ft' ---- 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2757 ft2 0 ft2 Light N 0.3 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2545 ft2 N N 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 296 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 0 Blown 156 ft2 0.1 Wood 3 Under Attic (Unvented) M WIC 0 Blown 84 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET 0 Blown 32 ft2 0.1 Wood 5 Under Attic (Unvented) FOYER/LIVING R 0 Blown 380 ft2 0.1 Wood 6 Under Attic (Unvented) DINING RM 0 Blown 180 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 300 ft2 0.1 Wood 8 Under Attic (Unvented) HALLWAY 0 Blown 60 ft2 0.1 Wood 9 Under Attic (Unvented) LAUNDRY RM 0 Blown 216 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 3 0 Blown 156 ft2 0.1 Wood 11 Under Attic (Unvented) CLST 3 0 Blown 16 ft2 0.1 Wood 12 Under Attic (Unvented) BATH 2 0 Blown 72 ft2 0.1 Wood 13 Under Attic (Unvented) CLST 2 0 Blown 16 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 0 Blown 168 ft2 0.1 Wood 15 Under Attic (Unvented) HALL 0 Blown 52 ft2 0.1 Wood 16 Under Attic (Unvented) FAMILY RM 0 Blown 330 ft2 0.1 Wood 17 Under Attic (Unvented) CABANA BATH 0 Blown 31 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceArPR , le Ft1 N Exterior Concrete Block - Int InsuMASTER BE 4.1 18 0 10 4 186.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int InsuMASTER BE 4.1 17 0 10 4 175.7 ft2 0 0 0.3 0 3 N Exterior Concrete Block - Int Insul M BATH 4.1 9 0 9 4 84.0 ft2 0 0 0.3 0 4 E Exterior Concrete Block - Int Insul M BATH 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 5 N Exterior Concrete Block - Int Insul M TOILET 4.1 7 0 9 4 65.3 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Int Insul M TOILET 4.1 5 0 9 4 46.7 ft2 0 0 0.3 0 7 E Exterior Concrete Block - Int InsLIFOYER/LIVIN 4.1 20 0 14 0 280.0 ft2 0 0 0.3 0 8 S Garage Frame - Wood FOYER/LIVIN 11 5 0 14 0 70.0 ft2 0 0.1 0.3 0 9 W Exterior Concrete Block - Int InsulDINING RM 4.1 12 0 14 0 168.0 ft2 0 0 0.3 0 10 W Exterior Concrete Block - Int Insul KITCHEN 4.1 4 0 9 4 37.3 ft2 0 0 0.3 0 11 S Exterior Concrete Block - Int Insul-AUNDRY R 4.1 9 0 9 4 84.0 ft2 0 0 0.3 0 12 E Garage Frame - Wood LAUNDRY R 11 24 0 9 4 224.0 ft2 0 0.1 0.3 0 13 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.3 0 _ 14 S Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.3 0 15 S Exterior Concrete Block - Int Insul BATH 2 4.1 9 0 9 4 84.0 ft2 0 0 0.3 0 16 S Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.3 0 17 S Exterior Concrete Block - Int InsuBEDROOM 2 4.1 14 0 9 4 130.7 ft2 0 0 0.3 0 18 W Exterior Concrete Block - Int InsuBEDROOM 2 4.1 6 0 9 4 56.0 ftz 0 0 0.3 0 19 N Exterior Concrete Block - Int InsulFAMILY RM 4.1 22 0 10 4 227.3 ft2 0 0 0.3 0 20 S Exterior Concrete Block - Int InsulFAMILY RM 4.1 2 0 10 4 20.7 ft2 0 0 0.3 0 21 W Exterior Concrete Block - Int InsulFAMILY RM 4.1 16 0 10 4 165.3 ft2 0 0 0.3 0 22 N Exterior Concrete Block - Int InsVCABANA BAT 4.1 6 0 9 4 56.0 ftz 0 0 0.3 0 23 S Exterior Concrete Block - Int InsL(DABANA BAT 4.1 6 0 9 4 56.0 ft2 0 0 0.3 0 4/23/2021 2:36 PM EnergyGauge® USA 7.0 00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 I-UKM K4Ub-"LULU INVUI SUMMAKY GHt:L;KLI5I KtF'UKI WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 24 W Exterior Concrete Block - Int InsdABANA BAT 4.1 6 0 9 4 56.0 ft2 0 0 0.3 0 IleZe1:�? V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated LAUNDRY R None .23 2 8 6 8 17.8 ft2 WINDOWS V Wall # Ornt ID Frame Panes 1 N 1 Vinyl Low-E Single 2 W 2 Vinyl Low-E Single _ 3 E 4 Vinyl Low-E Single 4 N 5 Vinyl Low-E Single 5 E 7 Vinyl Low-E Single 6 E 7 Vinyl Low-E Single 7 E 7 Vinyl Low-E Single 8 W 9 Vinyl Low-E Single 9 S 11 Vinyl Low-E Single 10 S 13 Vinyl Low-E Single 11 S 15 Vinyl Low-E Single _ 12 S 17 Vinyl Low-E Single 13 N 19 Vinyl Low-E Single 14 W 21 Vinyl Low-E Single _ 15 N 22 Vinyl Low-E Single 16 S 23 Vinyl Low-E Single # Floor Area 1 624 ft2 ;fling Ar 624 ft2 Are NFRC U-Factor SHGC Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 Yes 0.65 0.25 GARAGE 5ed orientation Overhang mp Area Depth Separatic Y 20.0ft2 2ft0in 1ft4in N 33.3ft2 14ft0in 1ft4in Y 12.0ft2 12ft0in 1 ft4in Y 6.0ft2 2ft0in 1ft4in Y 45.0ft2 12ft0in 1ft4in Y 13.3ft2 12ft0in 1ft4in Y 20.0ft2 12ft0in 1 ft4in Y 30.0ft2 2ft0in 1ft4in N 20.0ft2 14ft0in 1ft4in Y 15.0ft2 2ft0in 1 114in Y 8.0ft2 2ft0in 1ft4in Y 15.0ft2 2ft0in 1ft4in N 33.3ft2 14ft0in 1ft4in Y 20.0ft2 2ft0in ift4in N 17.8ft2 12ft0in 1 114in Y 6.0ft2 2ft0in 1ft4in Wall 9ft Int Shade None None None None None None None None None None None None None None None None Wall Insulation 11 # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000336 2243.9 123.11 231.12 .1009 5 None None None None None None None None None None None None None None None None 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 17 48 kBtu/hr 1440 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.9 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — V -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar HeatinHJan Feb Mar Apr f Apr E May Jun Jul May Jun Jul Auge AuSeP Oct Nov f Oct Nov Dec Dec Ventin Jan Feb Mar [X] Apr [ May Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER/LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft ft' ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8lbs/sq.ft. ft' ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft' ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft' ft 0.3 FAMILY RM Default(8 Ibs/s .ft. ft2 ft 0.3 CABANA BATH 4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.