HomeMy WebLinkAboutENERGY CALCFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CAUSLEY RESIDENCE
Builder Name: DON HINKLE CONSTRUCTION
Street: TREE TOP TRAIL
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner: RAY AND AMI CAUSLEY
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(2543.7 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2249.70 ft2
b. Frame - Wood, Adjacent
R=11.0 294.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (2545.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2545.00 ft=
6. Conditioned floor area above grade (ft2) 2545
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(314.8 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 200
a. U-Factor: Sgl, U=0.65 314.78 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13 Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:17.00
c. U-Factor: N/A ft2
SHGC:
ft Area Weighted Average Overhang Depth: 8.738 .
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap: 1 gallons
9. Floor Types (2545.0 sqft.) Insulation Area
EF:0.900
a. Slab -On -Grade Edge Insulation R=0.0 2545.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.124 Total Proposed Modified Loads: 73.71
PASS
Total Baseline Loads: 78.24
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7,42,
this calculation are in mpliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
�
yai` �„ ' •��� 0
with the Florida Energy Code
rnrr. �•, :;:: „ O
PREPARED BY:
Before construction is completed
DATE: 4-27-2021
this building will be inspected for
a
compliance with Section 553,908
e °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Co
COD yyg'l4�
OWNER/AGEN
BUILDING OFFICIAL:
_
DATE:
DATE:
_..._ -.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
CAUSLEY RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2545
Lot #
Owner Name:
RAY AND AMI CAUSLEY
Total Stories:
1
Block/Subdh4sion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
DON HINKLE CONSTRUCTI
Rotate Angle:
0
Street:
TREE TOP TRAIL
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2545
26926.5
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
296
3048.8 No
0
1
1
Yes
Yes
Yes
2
M BATH
156
1451 No
0
1
Yes
Yes
Yes
3
M WIC
84
781.2 No
0
1
No
Yes
Yes
4
M TOILET
32
297.6 No
0
1
Yes
Yes
Yes
5
FOYER/LIVING RM
380
5320 No
0
1
Yes
Yes
Yes
6
DINING RM
180
2520 No
0
1
Yes
Yes
Yes
7
KITCHEN
300
2790 Yes
0
1
Yes
Yes
Yes
8
HALLWAY
60
558 No
0
1
No
Yes
Yes
9
LAUNDRY RM
216
2009 No
0
1
Yes
Yes
Yes
10
BEDROOM 3
156
1450.8 No
0
1
1
Yes
Yes
Yes
11
CLST 3
16
148.8 No
0
1
Yes
Yes
Yes
12
BATH 2
72
669.6 No
0
1
Yes
Yes
Yes
13
CLST 2
16
148.8 No
0
1
Yes
Yes
Yes
14
BEDROOM 2
168
1562.4 No
0
1
1
Yes
Yes
Yes
15
HALL
52
483.6 No
0
1
No
Yes
Yes
16
FAMILY RM
330
3399 No
0
1
Yes
Yes
Yes
17
CABANA BATH
31
288 No
0
1
Yes
Yes
Yes
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
35 ft
296 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
2O.9 ft
156 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
M W IC
1 ft
84 ft'
----
1
0
0
4 Slab -On -Grade Edge Insulation
M TOILET
12 ft
32 ft'
----
1
0
0
5 Slab -On -Grade Edge Insulation
FOYER/LIVING R
20 ft
380 ft'
----
1
0
0
6 Slab -On -Grade Edge Insulation
DINING RM
12 ft
180 ft2
----
1
0
0
7Slab-On-Grade Edge Insulation
KITCHEN
4 ft
300 ft'
----
1
0
0
8 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
60 ft'
----
1
0
0
9Slab-On-Grade Edge Insulation
LAUNDRY RM
9 ft
216 ft'
----
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
156 ft'
_---
1
0
0
11SIab-On-Grade Edge Insulation
CLST 3
2 ft
16 ft'
----
1
0
0
12SIab-On-Grade Edge Insulation
BATH 2
9 ft
72 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
CLST 2
2 ft
16 ft'
----
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 2
20 ft
168 ft'
----
1
0
0
15SIab-On-Grade Edge Insulation
HALL
1 ft
52 ft'
----
1
0
0
16SIab-On-Grade Edge Insulation
FAMILY RM
40 ft
330 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
CABANA BATH
18 ft
31 ft'
----
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Metal 2757 ft2
0 ft2 Light
N
0.3 No 0.9
No
20
22.62
ATTIC
V # Type
Ventilation
Vent
Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2545 ft2
N N
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) MASTER BEDRO
0
Blown
296 ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
0
Blown
156 ft2
0.1
Wood
3
Under Attic (Unvented) M WIC
0
Blown
84 ft2
0.1
Wood
4
Under Attic (Unvented) M TOILET
0
Blown
32 ft2
0.1
Wood
5
Under Attic (Unvented) FOYER/LIVING R
0
Blown
380 ft2
0.1
Wood
6
Under Attic (Unvented) DINING RM
0
Blown
180 ft2
0.1
Wood
7
Under Attic (Unvented) KITCHEN
0
Blown
300 ft2
0.1
Wood
8
Under Attic (Unvented) HALLWAY
0
Blown
60 ft2
0.1
Wood
9
Under Attic (Unvented) LAUNDRY RM
0
Blown
216 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 3
0
Blown
156 ft2
0.1
Wood
11
Under Attic (Unvented) CLST 3
0
Blown
16 ft2
0.1
Wood
12
Under Attic (Unvented) BATH 2
0
Blown
72 ft2
0.1
Wood
13
Under Attic (Unvented) CLST 2
0
Blown
16 ft2
0.1
Wood
14
Under Attic (Unvented) BEDROOM 2
0
Blown
168 ft2
0.1
Wood
15
Under Attic (Unvented) HALL
0
Blown
52 ft2
0.1
Wood
16
Under Attic (Unvented) FAMILY RM
0
Blown
330 ft2
0.1
Wood
17
Under Attic (Unvented) CABANA BATH
0
Blown
31 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
SpaceArPR
, le Ft1
N
Exterior Concrete Block - Int InsuMASTER BE
4.1
18
0 10
4
186.0 ft2
0
0
0.3
0
2
W
Exterior Concrete Block - Int InsuMASTER BE
4.1
17
0 10
4
175.7 ft2
0
0
0.3
0
3
N
Exterior Concrete Block - Int Insul M BATH
4.1
9
0 9
4
84.0 ft2
0
0
0.3
0
4
E
Exterior Concrete Block - Int Insul M BATH
4.1
12
0 9
4
112.0 ft2
0
0
0.3
0
5
N
Exterior Concrete Block - Int Insul M TOILET
4.1
7
0 9
4
65.3 ft2
0
0
0.3
0
6
E
Exterior Concrete Block - Int Insul M TOILET
4.1
5
0 9
4
46.7 ft2
0
0
0.3
0
7
E
Exterior Concrete Block - Int InsLIFOYER/LIVIN
4.1
20
0 14
0
280.0 ft2
0
0
0.3
0
8
S
Garage Frame - Wood FOYER/LIVIN
11
5
0 14
0
70.0 ft2
0
0.1
0.3
0
9
W
Exterior Concrete Block - Int InsulDINING RM
4.1
12
0 14
0
168.0 ft2
0
0
0.3
0
10
W
Exterior Concrete Block - Int Insul KITCHEN
4.1
4
0 9
4
37.3 ft2
0
0
0.3
0
11
S
Exterior Concrete Block - Int Insul-AUNDRY R
4.1
9
0 9
4
84.0 ft2
0
0
0.3
0
12
E
Garage Frame - Wood LAUNDRY R
11
24
0 9
4
224.0 ft2
0
0.1
0.3
0
13
S
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
13
0 9
4
121.3 ft2
0
0
0.3
0
_ 14
S
Exterior Concrete Block - Int Insul CLST 3
4.1
2
0 9
4
18.7 ft2
0
0
0.3
0
15
S
Exterior Concrete Block - Int Insul BATH 2
4.1
9
0 9
4
84.0 ft2
0
0
0.3
0
16
S
Exterior Concrete Block - Int Insul CLST 2
4.1
2
0 9
4
18.7 ft2
0
0
0.3
0
17
S
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
14
0 9
4
130.7 ft2
0
0
0.3
0
18
W
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
6
0 9
4
56.0 ftz
0
0
0.3
0
19
N
Exterior Concrete Block - Int InsulFAMILY RM
4.1
22
0 10
4
227.3 ft2
0
0
0.3
0
20
S
Exterior Concrete Block - Int InsulFAMILY RM
4.1
2
0 10
4
20.7 ft2
0
0
0.3
0
21
W
Exterior Concrete Block - Int InsulFAMILY RM
4.1
16
0 10
4
165.3 ft2
0
0
0.3
0
22
N
Exterior Concrete Block - Int InsVCABANA BAT
4.1
6
0 9
4
56.0 ftz
0
0
0.3
0
23
S
Exterior Concrete Block - Int InsL(DABANA BAT
4.1
6
0 9
4
56.0 ft2
0
0
0.3
0
4/23/2021 2:36 PM EnergyGauge® USA 7.0 00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
I-UKM K4Ub-"LULU INVUI SUMMAKY GHt:L;KLI5I KtF'UKI
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
24 W Exterior Concrete Block - Int InsdABANA BAT 4.1 6 0 9 4 56.0 ft2 0 0 0.3 0
IleZe1:�?
V # Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated LAUNDRY R None .23 2 8 6 8 17.8 ft2
WINDOWS
V
Wall
#
Ornt
ID
Frame
Panes
1
N
1
Vinyl
Low-E Single
2
W
2
Vinyl
Low-E Single
_ 3
E
4
Vinyl
Low-E Single
4
N
5
Vinyl
Low-E Single
5
E
7
Vinyl
Low-E Single
6
E
7
Vinyl
Low-E Single
7
E
7
Vinyl
Low-E Single
8
W
9
Vinyl
Low-E Single
9
S
11
Vinyl
Low-E Single
10
S
13
Vinyl
Low-E Single
11
S
15
Vinyl
Low-E Single
_ 12
S
17
Vinyl
Low-E Single
13
N
19
Vinyl
Low-E Single
14
W
21
Vinyl
Low-E Single
_ 15
N
22
Vinyl
Low-E Single
16
S
23
Vinyl
Low-E Single
# Floor Area
1 624 ft2
;fling Ar
624 ft2
Are
NFRC U-Factor SHGC
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
Yes
0.65
0.25
GARAGE
5ed orientation
Overhang
mp
Area
Depth
Separatic
Y
20.0ft2
2ft0in
1ft4in
N
33.3ft2
14ft0in
1ft4in
Y
12.0ft2
12ft0in
1 ft4in
Y
6.0ft2
2ft0in
1ft4in
Y
45.0ft2
12ft0in
1ft4in
Y
13.3ft2
12ft0in
1ft4in
Y
20.0ft2
12ft0in
1 ft4in
Y
30.0ft2
2ft0in
1ft4in
N
20.0ft2
14ft0in
1ft4in
Y
15.0ft2
2ft0in
1 114in
Y
8.0ft2
2ft0in
1ft4in
Y
15.0ft2
2ft0in
1ft4in
N
33.3ft2
14ft0in
1ft4in
Y
20.0ft2
2ft0in
ift4in
N
17.8ft2
12ft0in
1 114in
Y
6.0ft2
2ft0in
1ft4in
Wall
9ft
Int Shade
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Wall Insulation
11
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000336 2243.9 123.11 231.12 .1009 5
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 17
48 kBtu/hr
1440 cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric Tankless
Garage
0.9 1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
V
-- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 200 ft2
Attic
20 ft2 Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
HeatinHJan Feb Mar
Apr
f Apr E
May Jun Jul
May Jun Jul
Auge
AuSeP
Oct Nov
f Oct Nov
Dec
Dec
Ventin Jan Feb Mar
[X] Apr [
May Jun Jul
Aug
Se
[X] Oct Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10 11
12
Cooling (W D) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER/LIVING
RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft
ft'
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8lbs/sq.ft.
ft'
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft'
ft
0.3
FAMILY RM
Default(8 Ibs/s .ft.
ft2
ft
0.3
CABANA BATH
4/23/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.