HomeMy WebLinkAboutProdcut Approval Business & Professional •g +t
BCIS Home i Log In User Registration Hot Topics Submit Surcharge Stats&Fads Publications Contact Us BCIS Site Map Links Search l
bProduct
Approval
dpr 4 USER:Public User
Product Approval Menu>Product or Application Search>Apolication Lis[>Application Detail RECEIVED �,r�
FL# FL17834-R2 JUN ® 1 2021 06 J w (S 01-
Application Type Revision ED
41 it
Code Version 2020 Permitting Department .;�;,, � Ar rA�
Application Status Approved St. Lucie County m '
Ir COE
Comments � _ LUG CCU
c
Archived R Q�+C
Product Manufacturer L.V. Thompson, Inc. dba Thompson Architectural Metals Company (TAMCO)
Address/Phone/Email 5015 East Hillsborough Ave.
Tampa, FL 33610
(813) 248-3456
tony@gometalroofing.com
Authorized Signature Tony Christman
Copy
tony@gometalroofing.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/20/2024
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL17834 R2 COI LVT15001.2a 2020 FBC Eval Perforated Ridge Channel
final•pdf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1504.2.1
1507.3.7
1518.8.1
Product Approval Method Method 2 Option B
Date Submitted 09/16/2020
Date Validated 09/17/2020
Date Pending FBC Approval 09/22/2020
Date Approved 12/15/2020
Summary of Products
FL# Model, Number or Name Description
17834.1 L.V.Thompson Ridge- Perforated Min. 26 ga. perforated ridge for use with clay and concrete roof
tile
— .........-......._..._._ ...................... --- --
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL17834 R2 II LVT15001.2a 2020 FBC Eval Perforated Ridgg
Approved for use outside HVHZ: Yes Channel final.12df
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-244 Created by Independent Third Party: Yes
Other: See evaluation for limits of use. Evaluation Reports
FL17834 R2 AE LVT15001.2a 2020 FBC Eval Perforated Ridgg
Channel final.p,dt
Created by Independent Third Party: Yes
17834.2 L.V.Thompson Tile Hip/Ridge Metal Min. 26 ga. metal channel for use as a hip and ridge base with
Channel - Non-perforated clay and concrete roof tiles.
_.._..._.._......_..._-....--- -...---- -- ----...._._...---- — —
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL17834 R2 II LVT15001.2b 2020 FBC Eval HilRiid a Channel
Approved for use outside HVHZ: No HVHZ final.12d
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL17834 R2 AE LVT15001.2b 2020 FBC Eval Hi Ri gg
Channel HVHZ final.pdf
Created by Independent Third Party: Yes
'tick tacat.
on ::2601 it n R Tallahassee FL 2 Phone: -4 7- 4
Contact Us _fi0 Blair Stone oad, alla ssee 3 399 o e 850 8 182
The State of Florida is an AA/EEO employer.Copyriaht 2007-2013 State of Florida. ::Priva Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
eCheck E
Credit Card
Safe
� llmit�Im
G R E E K Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020)
Manufacturer: L.V. THOMPSON, INC. Issued September 16, 2020
dba Thompson Architectural Metals Company(TAMCO)
5015 E. Hillsborough Ave
Tampa, FL 33610
(813)248-3456
htti)://www.tamcometalroof.com
Manufacturing: Tampa, FL
Quality Assurance: PRI Construction Materials Technologies(QUA9110)
SCOPE
Category: Roofing
Subcategory: Roofing Accessories that are an integral part of the roofing system
Code Edition: Florida Building Code, 7`"Edition (2020)including High-Velocity Hurricane Zones(HVHZ)
Code Sections: 1504.2.1, 1507.3.7, 1518.8.1
Properties: Wind Resistance
PRODUCT DESCRIPTION
L.V. Thompson Ridge— Perforated
Dimensions: 10-ft lengths; 3, 4, 5,6, 7, and 8-inch heights
Description: ASTM A 653 G90 or ASTM A 792, preformed metal channel for use as a hip and ridge
base with clay and concrete roof tiles
Material: Min. 26 ga. steel; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 (non-
HVHZ)and 1517.6(HVHZ).
REFERENCES
Enti _t Report No. Standard Year
PRI Construction Materials Technologies(TST5878) LVTI-017-02-01 SBCCI SSTD 11 1997
TAS 101 1995
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. In the non-HVHZ,design wind loads shall be determined by others in accordance Section 1609 of the FBC.
3. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
4. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
LVT15001.2a FL17834-R2 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
a
CREEK L.V. THOMPSON, INC.
Perforated Ridge Channel
TECHNICAL SERVICES, LLC
INSTALLATION(HVHZ)
The component and installation shall comply with one of the following:
1) RAS 118, Detail 3
2) RAS 119, Detail 3
3) RAS 120, Detail 3
Perforated Ridge shall be attached 6-inch o.c.with approved fasteners, at minimum. Refer to manufacturer's
installation instructions as a supplemental guide for attachment.
P :
Ridge Tile
V
P
Pefftxated Ridge
Channel
Roof Deck
Approved Pooling f`als
: ved 6 o c
INSTALLATION(NON-HVHZ)
Roof Deck: Minimum 15/32-inch APA span rated plywood sheathing for new and existing roof deck
(Deck shall be designed by others in accordance with FBC requirements).
Perforated Ridge Minimum 11 ga. x 1.25 galvanized, ring shank nails attached 6-inch o.c. along each
Channel: mounting flange into the wood deck.
Ridge Tile: Clay or Concrete Ridge Tile shall be attached to the PERFORATED RIDGE CHANNEL
with one (1) 2-inch x 7-inch paddy (approx. 35g) of ICP Adhesives Polyset AH-160 as
shown below.
Or
Concrete Ridge Tile shall be attached to the PERFORATED RIDGE CHANNEL with one
(1)2-inch x 7-inch paddy(approx. 35g)of ICP Adhesives Polyset RTA-1 as shown below.
Maximum Uplift -233 psf with clay ridge tile adhered with ICP Adhesives Polyset AH-160
Resistance: -244 psf with concrete ridge tile adhered with ICP Adhesives Polyset AH-160
-126 psf with concrete ridge tile ICP Adhesives Polyset RTA-1
Calculated using 2:1 margin of safety per 1504.9.
LVT15001.2a FL17834-R2 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.