Loading...
HomeMy WebLinkAboutProdcut Approval-roof tile Ikit ® BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications i Contact Us j BCIS Site Map i Links Search drFioritia V Product Approval 006 USER: Public User �( .,. REVIEWED FOR 66 Product Approval Menu>Product or Application Search>Application List>Application Detail • • �V FL # FL7849 R14 C COMPLIANCE ODE Application Type Revision ST. LUCIE COUNTY Code Version 2020 BOCC Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Fi.le CLAY Comments Archived RECEIVED Product Manufacturer Boral Roofing Address/Phone/Email 7575 Irvine Center Drive JUN 0 1 1011 Suite 100 Irvine, CA 92618 Permitting Department (801) 380-6091 St. Lucie County RobinAnderson@boral.com Authorized Signature Anderson Robin RobinAnderson@boral.com Technical Representative Robin Anderson Address/Phone/Email 10701 So. River Front Parkway Suite 300 So. Jordan, UT 84095 (801) 380-6091 robinanderson@boral.com Quality Assurance Representative Robin Anderson Address/Phone/Email 7575 Irvine Center Dr. #100 Irvine, CA 92618 (801) 380-6091 robinanderson@boral.com Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity IAPMO Uniform Evaluation Services LLC. Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2025 Validated By Gary W. Walker Validation Checklist- Hardcopy Received Certificate of Independence FL7849 R14 COI IAPMO Uniform ES - Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM C1492 2009 ASTM E108 2016 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted 02/15/2021 Date Validated 05/07/2021 Date Pending FBC Approval Date Approved 05/11/2021 Summary of Products Go to Page (0 0 0 Page 2/2 0 0 D Model, Number or Name Description :Approved 1j Saxony 900 Flat Profile- Okeechobee, FL of U Installation Instructions HVHZ: No FL7849 R14 II EBS-Installation.{�df e for use in HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.Rd Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.22 Saxony 900- Hartford Slate, Shake, Flat Profile- Stockton, CA Slate, Country Slate&Split Old English Thatch Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.23 Saxony 900- Shake&Slate Flat Profile- Lathrop, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pd Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w ERpd 7849.24 Saxony 900 -Shake, Slate&Country Flat Profile- Henderson, NV Slate Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.p 1f Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP pdf 7849.25 Saxony 900 - Shake, Slate, Split Flat Profile- Lake Wales FL lShake&Country Slate Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP pdf 7849.26 Saxony 900 -Slate, Shake&Country Flat Profile - Rialto, CA Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.p� 7849.27 Tejas Espana/Barcelona High Profile- Katy,TX Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w ERpdf -_ _ - --- il--- --- - — — 7849.28 Villa Low Profile - Katy,TX Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w ERpd 7849.29 Villa Low Profile- Phoenix, AZ Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.30 Villa 600&900 Low Profile - Rialto, CA --------------- Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.31 Villa 600 &900 Low Profile -Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w ERpdf 7849.32 Villa 900 Low Profile- Lake Wales, FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installtion.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP pdf 7849.33 Villa 900 Low Profile-Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.34 Villa 900 Low Profile- Denver, CO Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf 7849.35 Villa Impact Low Profile- Denver, CO Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R14 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R14 II Florida High Wind Tile Installation Manual - Impact Resistant: N/A 6th Edition.p- Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R14 AE IAPMO UER 0412 w EP.pdf Go to Page 0 0 Page 2/2 0 0 Back Nett Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® Ed Credit Card Safe A UE$ E"LUATIONREPORT412 ® Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 BORAL ROOFING 3.0 PRODUCT USE 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 3.1 General: Boral Roofing Concrete Roof Tiles shall be (949) 756-1605 used as a roof covering in accordance with IBC Section www.BoralRootcom 1503 or IRC Section 903,as applicable. CONCRETE ROOF TILES 3.2 Installation: CSI Section: 3.2.1 Installation in accordance with the 2018 IBC or 07 32 16 Concrete Roof Tiles IRC: Boral Concrete Roof Tiles shall be installed in accordance with 2018 IBC Section 1507.3 or 2018 IRC 1.0 RECOGNITION Section R905.3, including the attachment requirements of Boral Roofing Concrete Roof Tiles recognized in this report 2018 IBC Section 1507.3.7 or 2018 IRC Section R905.3.7, have been evaluated for use as concrete roof tiles. The as applicable. Underlayment shall conform to 2018 IBC weather resistance, wind uplift resistance and fire Section 1507.1.1 or 2018 IRC Section R905.1.1.Installation classification properties of the roof tiles comply with the of accessory tiles,EnviroProe see section 4.1.1. intent of the provisions of the following codes and regulations: 3.2.2 Installation in accordance with the 2015, 2012, 2009,or 2006 IBC or IRC:Boral Concrete Roof Tiles shall • 2018, 2015, 2012, 2009, and 2006 International be fastened in accordance with the code specific Building Code®(IBC) requirements in Table 1 of this report using The Concrete • 2018, 2015, 2012, 2009, and 2006 International and Clay Roof Tile Installation Manual for Moderate Residential Code®(IRC) Climate Regions, dated July 2015, published by the Tile • 2019 California Building Code(CBC)—Supplement Roofing Institute and the Western States Roofing attached Contractors Association. The July 2015 TRI manual is • 2019 California Residential Code (CRC) — associated with ER-2015 in the UES Evaluation Report Supplement attached Directory and available for download at www.uniform- • 2020 Florida Building Code, Building (FBC, es•ore. Installation of accessory riles, EnviroPro® see Building)—Supplement attached section 4.1.1. • 2020 Florida Building Code, Residential (FBC, Residential)—Supplement attached TABLE 1—ATTACHMENT DESIGN Applicable Design 2.0 LIMITATIONS Code Criteria for Applicability Information Location Use of the Boral Roofing Concrete Roof Tiles recognized in 2015 or Ultimate Design Wind Roof Tile this report is subject to the following limitations: 2012 IBC Speeds(Vw,)s 130 MPH and Installation Mean Roof Hei t<60 feet Manual&Table 2.1 The roof tiles shall be manufactured, identified and 2009 or Basic Wind Speed(3 sec 1507.3.7 of the2006 IBC gust):5 100 mph and Mean applicable IBC installed in accordance with this report and the applicable Roof Hei t s 60 feet code.In the event of a conflict this report governs. 2015,2012, Roof Tile 2009 or Mean Roof Heights 40 feet Installation 2.2 Boral Roofing"concrete roof tile shall be installed on 2006 IRC Manual&Section roof slopes of 21/2 units vertical in 12 units horizontal(21- For SI:1 foot=305 mm,1 mph=1.6 m/s R905.3.7 percent slope)or greater."IBC Section 1507.3.2. 2.3 The supporting structure shall be designed to support the 3.3 Anchoring: Boral Concrete Roof tiles may be anchored loads and is beyond the scope of this report. using mortar in accordance with the applicable building code and,where permitted,the TRI Manual or adhesively attached 2.4 The Concrete Roof Tiles recognized in this report are in accordance with the adhesive manufacturer's research manufactured in Lake Wales,FL;Brookshire,TX;Phoenix, report issued by an approved evaluation service agency. AZ; Henderson,NV; Okeechobee, FL, Rialto, CA; French Camp, CA; Henderson, CO and Lathrop, CA; Tables 2 A through 2 I describe the tiles produced at each location. C � The product described in this Uniform Evaluation Service(LIES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply \� E with the intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the code in quality,strength,effectiveness,fire resistance,durability and safety,as applicable,in accordance with 18C Section 104.11,This document she//only be reproduced in its entirety. Copyright®2020 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States. Ph:1-877-41ESRPT•Fax:909.472.4171 web:www.uni/orm-es.org•4755 East Philadelphia Street,Ontario,California 91781-2816—USA ISQ'IEC 11065 Page 1 of 7 "°°""c."m""b"a°°y UES EVALUATION REPORT Number: 12 ® Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 4.0 PRODUCT DESCRIPTION 5.0 IDENTIFICATION Boral Roofing Concrete Roof Tiles comply with ASTM Shipping pallets are identified with the report holder's C1492 as required by Section 1507.3.5 of the IBC.The roof name (Boral Roofing), manufacturing address, product tiles are described by model, weight, dimensions, and tile name, installed weight, inspection agency,and evaluation factor in Tables 2 A through 2 1, for each of the production report number(ER-412). The Cedarlite 600, Madera 700 locations listed in Section 2.4 of this report. When installed and Madera 900 tiles are imprinted on the top side of each in accordance with this report on minimum 15/32-inch-thick tile with an"M",all other field tiles are imprinted with the (12 mm)plywood solid sheathing or non-combustible decks, name "Boral", `Boral Lifetile", "Monierlifetile", or the the assembly incorporating the roof riles achieve an ASTM Boral Roofing,or MonierLifetile or"Vostile"or logo.The E108 Class A rating per Section 1505.2 of the IBC and Boral EnviroPro product shall be clearly identified to Section R902.1 of the IRC, as applicable. Roof provide distinction between field tiles and accessory tiles classifications for adhesively attached systems shall be in as stated in the EnviroPro product installation guidelines. accordance with the adhesive manufacturer's approved The identification includes the IAPMO Uniform research report. Evaluation Service Mark of Conformity. Either Mark of Conformity may be used as follows: 4.1 Accessories: Boral EnviroPro® recognized in this report has been evaluated for use as an accessory product to be used with A P M 0 or U E S concrete roof tiles. The weather resistance, wind uplift resistance and fire classification properties of the product E S complies with the intent of the provisions of the codes and O O regulations in Section 1.0 of this report.The Boral EnviroPro IAPMO UES ER-412 product is subject to all limitations in Section 2.0 of this report. The Boral EnviroPro product complies with ASTM 6.0 SUBSTANTIATING DATA C 1492 as required by Section 1507.3.5 of the IBC.The Boral EnviroPro product is described by model, weight, Data in accordance with ICC-ES AC180, dated February dimensions,and tile factor in Tables 2 A through 21,for each 2012 (editorially revised March 2018), manufacturer's of the production locations listed in Section 2.4 of this report. descriptive literature and installation instructions. Test When installed in accordance with this report on minimum reports are from laboratories in compliance with ISO/IEC 15/32-inch-thick(12 mm)plywood solid sheathing or non- 17025. combustible decks, the assembly incorporating the Boral EnviroPro product achieves an ASTM E108 Class A rating 7.0 STATEMENT OF RECOGNITION per Section 1505.2 of the IBC and Section R902.1 of the IRC, as applicable. This evaluation report describes the results of research completed by IAPMO Uniform Evaluation Service on Boral 4.1.1 Installation: Roofing Concrete Roof Tiles to assess conformance to the codes shown in Section 1.0 of this report and serves as The Boral EnviroPro accessory product shall be limited to documentation of the product certification. Products are installation where roof tiles must be cut, such as in valleys manufactured at locations noted in Section 2.4 of this report and boundary edges at rakes,walls,chimneys,skylights,and under a quality control program with periodic inspection other roof openings and penetrations. The installed dry under the supervision of IAPMO UES. weight of Boral EnviroPro is equivalent to that of the tile profile in Tables 2A-21 with which it is used. For additional information about this evaluation report please visit www.uniform-es.or or email us at info(Wuniform-es.ore Page 2 of 7 EVALUATION REPORT Numberz, 412 CUE Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 Table 2 A-Tiles Manufactured at Denver(Henderson),CO Installed Dr DimemsionsZ Y Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Saxony—Shake,Slate,Country 9.6 17 X 13 1.568 1.115 Slate Split Old English Thatch Saxon —Im act 10.5 17 X 13 1.568 1.115 Villa 900 9.0 17 X 13 1.503 1.068 Villa—Impact 10.1 17 X 13 1 1.503 1.068 For SI: I inch=25.4 mm,1 psf=4.88 kg/mZ Table 2 B-Tiles Manufactured at Henderson,NV Installed D DimemsionsZ r3' Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio I Espana/Barcelona 9.0 17 X 123/8 1.470 1.045 Saxony 900—Shake,Slate, 9.1 17 X 13 1.533 1.090 Country Slate For SI: I inch=25.4 mm,1 psf=4.88 kg/m2 Table 2 C-Tiles Manufactured at Katy(Brookshire),TX Installed Dry DimemsionsZ Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Barcelona—Impact 10.3 16'/2 X 13 1.444 1.027 Saxony—Country Shake,Country Slate,Country Split Shake,English 10.3 16%2 X 13 1.392 0.989 Thatch Saxon —Impact 10.5 16'/2 X 13 1.392 0.989 Saxon —Shake,Slate 10.3 16'/2 X 13 1.392 0.989 Teas Espana/Barcelona 9.0 16'/2 X 13 1.407 1.000 Villa 9.0 16'/2 X 13 1.407 1.000 For SI:1 inch=25.4 mm,1 psf=4.88 kg/m2 NOTES TO TABLES: 1. Used on a 3-inch head-lap. 2. Nominal dimension. Page 3 of 7 VEg EVALUATION REPORT Number:,,,,, , 12 ® Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 Table 2 D-Tiles Manufactured at Lake Wales,FL Installed Dry Dimemsions2 Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Barcelona 900 9.5 17 X 13 1.525 1.084 Saxony 900—Shake,Slate,Split 9.5 17 X 13 1.545 1.098 Shake Country Slate Spanish"S"Nuevo 9.9 17 X 93/4 1.144 0.813 Villa 900 9.2 17 X 13 1.533 1.090 For SI: 1 inch=25.4 mm,I psf=4.88 kg/m2 Table 2 E-Tiles Manufactured at Lathrop,CA Installed Dry Dimemsions2 Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Barcelona 900 9.3 17 X 13 1.509 1.073 Saxon 900—Shake Slate 9.1 17 X 13 1.533 1.090 For SI: 1 inch=25.4 mm,I psf=4.88 kg/m2 Table 2 F-Tiles Manufactured at Phoenix,AZ Installed Dry Dimemsions2 Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Mission S/Barcelona 10.3 16'/2 X 13 1.494 1.062 Saxon —Shake,Slate 9.5 16'/2 X 13 1.494 1.062 Villa 9.0 16%2 X 13 1.407 1.000 For SI:1 inch=25.4 mm,1 psf=4.88 kg/m2 Table 2 G-Tiles Manufactured at Okeechobee,FL Installed Dry Dimemsions2 Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Bermuda 12.44 16'/s X 101/s 1.036 0.736 Estate"S" 7.9 16%2 X 13 1.417 1.007 Galena Spanish"S" 9.3 17 X 10 1.144 0.831 Plantation 10.4 16'/2 X 13 1.426 1.014 Saxony 900 9.3 17 X 13 1.533 1 1.090 For SI:1 inch=25.4 mm,1 psf=4.88 kg/mz NOTES TO TABLES: I. Used on a 3-inch head-lap. 2. Nominal dimension. Page 4 of 7 UES EVALUATION REPORTNumber: 12 Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 Table 2 H-Tiles Manufactured at Rialto,CA Installed D DimemsionsZ Dry Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio Espana/Barcelona 9.0 17 X 123/s 1.454 1.033 Espana 600/Barcelona 600 5.9 17 X 123/s 1.454 1.033 Saxony 600-Slate,Shake,Split 5.9 17 X 13 1.533 1.090 Shake Saxony 700-Slate,Shake,Split 7.1 17 X 13 1.533 1.090 Shake Saxony 900-Slate,Shake,Country 9.3 17 X 13 1.533 1.090 Shake Villa 600 5.8 17 X 13 1.494 1.061 Villa 900 9.0 17 X 13 1.494 1.061 For SI:1 inch=25.4 mm,1 psf=4.88 kg/m2 Table 2 I-Tiles Manufactured at Stockton(French Camp),CA Installed Dry DimemsionsZ Tile Factor Tile Weight' inch (psf) Length X Width TF(ft3) Ratio' Cedarlite 600 5.9 13'/2 X 13 0.942 0.673 Madera 700 7.2 13'/2 X 13 0.947 0.673 Madera 900 9.5 13'/2 X 13 0.947 0.673 Saxon 600-Slate Shake Split Shake 5.7 17 X 13 1.525 1.084 Saxon 700-Slate,Shake,Split Shake 7.2 17 X 13 1.525 1.084 Saxony 900-Hartford Slate,Shake,Slate Country Slate 9.1 17 X 13 1.533 1.090 Saxon 900-Split Old English Thatch 9.8 17 X 13 1.525 1.084 Villa 600 6.0 17 X 13 1.494 1.115 Villa 900 9.3 17.X 13 1.494 1.115 For SI:1 inch=25.4 mm,1 psf=4.88 kg/m2 NOTES TO TABLES: 1. Used on a 3-inch head-lap. 2. Nominal dimension. Page 5 of 7 qUES . 412 Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 CALIFORNIA SUPPLEMENT 2.4 Boral Roofing concrete roof tiles used on structures regulated by the Division of the State Architect or the Office BORAL ROOFING of Statewide Planning and Development are subject to 7575 Irvine Center Drive, Suite 100 installation provisions in CBC Section 1513. Irvine, California 92618 For additional information about this evaluation report please visit (949)756-1605 www.uniform-es.ore or email us at infoaa uniform-es.ore www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Concrete Roof Tiles and accessories evaluated in IAPMO UES ER412 are satisfactory alternative roof covering materials in accordance with the following codes and regulations: • 2019 California Building Code(CBC) • 2019 California Residential Code(CRC) 2.0 PRODUCT USE 2.1 The Boral Roofing concrete roof tiles may be used as a Class A, B, or C roof covering systems complying with Sections 1505.1.1 of the CBC or R902.1.1 of the CRC; Sections 1505.1.2 of the CBC or R902.1.2 of the CRC; or Sections 1505.1.3 of the CBC or R902.1.3 of the CRC, respectively. The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with Sections 1507.3.10 and 1513 CBC or Section 905.3 of the CRC,as applicable,and ER412. 2.2 Roof Tiles shall be installed in accordance with Sections 3.0 and 4.0 of ER412 except, where the building official requires conformance to the CBC or CRC,the following shall be substituted: 2.2.1 Underlayment shall conform with CBC Section 1507.1.1 or CRC Section 905.1.1. 2.2.2 Attachment of the concrete roof tiles shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3,as applicable. 2.3 Boral Roofing concrete roof tiles may be used in"new buildings located in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions" in accordance with Sections 701A.3 and 705A of the CBC, or Sections R337.1.3.1 and R337.5 of the CRC, as applicable, and with the IBC as presented in ER-412. Page 6 of 7 m = DES EVALUATION REPORT Number& 412 Originally Issued: 07/31/2015 Revised: 03/29/2020 Valid Through: 07/31/2021 FLORIDA SUPPLEMENT combinations shall be in accordance with Sections 1605.2 or 1605.3 of the FBC,Building,as applicable.Design wind BORAL ROOFING loads shall be in accordance with Section 1609.5 of the FBC, 7575 Irvine Center Drive, Suite 100 Building or Section R301.2.1 of the FBC, Residential, as Irvine, California 92618 applicable. (949)756-1605 www.boralamerica.com For additional information about this evaluation report please visit www.uniform-es.ora or email us at info6i uniform-es.ore CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Roofing concrete roof tiles and accessories evaluated in IAPMO UES ER-412 are a satisfactory alternative roof covering materials in accordance with to the following codes and regulations: • 2020 Florida Building Code, Building (FBC, Building) • 2020 Florida Building Code, Residential (FBC, Residential) 2.0 LEMTATIONS 2.1 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the production quality of products, in accordance with Section(5)(d)of Florida Rule 61 G20-3.008.The quality assurance agency shall be approved by the Commission(or the building official when the report holder does not possess an approval by the Commission). 2.2 Evaluation to the high-velocity hurricane zone provisions in Section 1512 of the FBC, Building and Chapter 44 of the FBC, Residential is beyond the scope of this report. 3.0 PRODUCT USE The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with the 2018 International Building Code and the 2018 International Residential Code, as applicable, as noted in ER-412. The FBC, Building Section 1507.3 and FBC,Residential Section R905.3 states that the installation of the Boral Roofing concrete roof tiles "shall be in accordance with the requirements of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition where the V.,d is determined in accordance with" FBC, Building Section 1609.3.1, FBC-Residential Section R301.2.1.3, or the recommendations of RAS 118, 119 or 120. Load Page 7 of 7