Loading...
HomeMy WebLinkAboutEngineeringEli eral gineering esting, Inc. DATE: 5/20/21 Phone: 954-784-2941 .875 . .. Environmental I Geotechnical I Materials Testing Roof Testing Inspections GPR CLIENT: Cardinal Roofing and Siding of Florida Order No 21R0417 ADDRESS: 1601 S.E. South Niemeva Circle: Port St Lucie, FL 34990 PROJECT: Roesemann Residence ADDRESS: 11100 Lando End Chase; Port St. Lucie, FL 34986 ASCE 7-16 DESIGN PRESSURE CALCULATIONS RECEIVED In Accordance with Chapter 30, Part I JUN 0 1 1011 Permitting Department Project Information: Sloped Wood Deck Roof St. Lucie County Height = 20' Exposure: C Length = 75' Category: H Width = 37' Slope: 6:12 Design Calculations: Ultimate Windspeed: Vint= 170 mph Basic Windspeed: Veld = 132 mph Kt= 0.90 Kd=0.85 Velocity Pressure: q = 0.00256*[(0.90)(0.85)(1.00)(1.00)(132)2] = 34.2 psf Width of Pressure Coefficient Zone: 0.1(37') = 3.7' 0.4(20') = 8.0' } use: a = 4'0" Effective Wind Area: <10ft2 For parapet height three feet (3) or larger, zone three (3) can be treated as zone two (2) (ASCE7-16). External Pressure Coefficient: 1) GCP1 = -1.4 2r) GCP2r = -2.0 2e) GCP2e = -2.0 3) GCP3 = -2.0 Design Pressures: 1) Field 2r) Perimeter Ridge: 2e) Perimeter Eave 3) Corners Internal Pressure Coefficient 1) GCPi = 0.18 P1 = 34.2*(-1.4 — 0.18) = -54.0 psf P2r = 34.2*(-2.0 — 0.18) = -74.6 psf P2e= 34.2*(-2.0 — 0.18) = -74.6 psf P3 = 34.2*(-2.0 — 0.18) = -74.6 psf �c- M E Approved laboratory F�r� Page 3 1 1100 Lando End Chase Port St Lucie, FL Based on RAS-127 and F.L. #7849.25, the following are our recommended tile attachment requirements: Attachment Requirements: Tile System: Moment Based (Boral Saxony 900 Flat Roof Tile) Aerodynamic Multiplier: 0.315 ft3 (Direct Deck Attachment) Restoring moment due to gravity: Mg = 7.17 ft. lb (6:12 slope) Attachment resistance expressed as a moment: Me = 83 ft-lb Single Medium Patty Foam Adhesive Set (24 g) Zone 1 Field: Mrt = (54.0*0.315) — 7.17 ft. lb = 9.9 ft. lb. < 83 ft. lb = PASS Zone 2e Perimeter Eave: Mrze = (74.6*0.315) — 7.17 ft. lb =16.3 ft. lb. < 83 ft. lb = PASS Zone 2r Perimeter Ridge: Mrz, _ (74.6*0.315) — 7.17 ft. lb = 16.3 ft. lb. < 83 ft. lb = PASS Zone 3 Corners: Mr3 = (74.6*0.315) — 7.17 ft. lb = 16.3 ft. lb. < 83 ft. lb = PASS System is acceptable as approved with ICP Adhesives Polyset AH-160 (Single Medium Paddy placement of 24 grams) Notes: All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2020 edition. Wind load calculations based on ASCE 7-16 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Sincerely, Keith LeBlanc, P.E. _7t Z, Federal Engineering & Testing, Inc. Florida Reg. No. 59394 Certificate of Authorization #5471 Miami -Dade County Certification #21-0201.02 --- • Aland Park, Florida 33334 �^� 1 MIMI®m MSMiOR� (6 FDOT �� � Approved Laboratory ��_