Loading...
HomeMy WebLinkAboutAPPROVED 21Tamko Asphalt Shingles4/7/2021 Florida Building Code Online fit BCIS Home 1 Log In User Registration ! Hot Topics i Submit Surcharge stats & Facts Publications l Contact us BCIS Site Map Links Search b'pr }Product ApprovalUSER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL18355-R6 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer TAMKO Building Products LLC Address/Phone/Email PO Box 97 Galena, KS 66739 (417)624-6644 Ext2305 kerri—eden@tamko.com Authorized Signature Kerr! Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Emall Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity UL LLC Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/18/2021 Validated By Robert Nieminen, PE, NEMO ETC, LLC Validation Checklist - Hardcopy Received Certificate of Independence FL18355 R6 COI UL Standards of Business Conduct - Independence.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTMD D7158 2019 Equivalence of Product Standards Certified By Sections from the Code https:l floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKAoKylAzpH5w7DkXuKoJ51Q%3d%3d 1/2 4/7/2021 Florida Building Code Online Product Approval Method Method 1 Option C Date Submitted 11/20/2020 Date Validated 11/23/2020 Date Pending FBC Approval Date Approved 11/24/2020 Summary of Products FL # Model, Number or Name `— _ .Description 18355.1 TAMKO Asphalt Shingles ASTM D3462 asphalt shingles and hip and ridge shingles Limits of Use Installation Instructions i Approved for use in HVHZ: No FL18355 R6 II 2020 11 18 TAMKO UL ER2919-0i.pdf Approved for use outside HVHZ: Yes Verified By: UL LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See evaluation report for limits of use. FL18355 R6 AE 2020 11 18 TAMKO UL ER2919-01.pdf E Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. a right 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refun Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Ed Credit Card Safe https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQW83MPT3uofKAoKy[AzpH5w7DkXuKoJ51 Q%3d%3d 2/2 MIAMI-DAD ` ° MIAMI-DADE COUNTY r PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE(NOA) w►vw.mtarnidade.aovreconomy TAMKO Building Products LLC 220 West 4th Street Joplin, MO 64801 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within "their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or.material fails to meet the requirements • of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof shingles • LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises and renews NOA No.19-1107.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino NOA No.: 20-0701.02 MIAMI•DADECGUNTY Expiration Date: 12/01/25 Approval Date: 11/05/20 Page 1 of 7 • • 4 w ROOFING ASSEMBLY APPROVAL Ca a or r Roofing Sub -Category: Asphalt Shingles Materi s: Laminate Deck Type: Wood SCOPE This approves TAMKO's Heritage, Heritage Woodgate, Heritage Premium, and Heritage Proline Titan XT w asphalt shingles, manufactured by TAMKO Building Products LLC, as described in this Notice of Acceptance and designed to comply with the Florida Building Code High Velocity Hurricane Zones. PRODUCT DESCRIPTION ft Product Dimensions Test Product Description Sgecifiications Heritage 13 '/a" x 39 3/e TAS 110 Dimensional asphalt shingle. Manufacturing Location # 1, 2, 3 Heritage Woodgate 13 '/4" x 39 3/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location # 1,3 • Heritage Premium 13'/4" x 39 3/$II TAS 110 Dimensional asphalt shingle. Manufacturing Location # 1, 2, 3 Heritage Proline Titan XT Manufacturing Location # 3, 4 13 1/411 x 39 3/81I TAS 110 Dimensional asphalt shingle, w MANUFACTURING LOCATIONS 1. Dallas, TX 2. Tuscaloosa, AL - 3. Frederick, MD 4. Phillipsburg, KS MIAMMADE COUNTY NOA No.: 20-0701.02 y Expiration Date: 12/01/25 Approval Date: 11/05/20 Page 2 of 7 a EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Reoort Date Underwriters Laboratories, Inc. TAS 107 & UL 790 04CA44252 02/25/05 _ ASTM D3462 02NK33813 09/23/02 ASTM D 3462 & TAS 107 R2919 Letter 03/10/11 ASTM D3462 4789110543 08/26/14 TAS 107 02/19/15 ASTM E 108 08/26/14 ASTM D3161, Class F 4787043752 l 0/20/15 ASTM D 3462 4789650787 10/12/20 R 2919 Letter 10/15/20 ASTM D 3462 4789682154 10/15/20 PRI Asphalt Technologies, Inc. TAS 100 TAP-129-02-01 05/26/05 TAS 100 TAP-130-02-01 05/26/05 TAS 100 TAP-131-02-01 05/26/05 PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14 TAS 100 TAP-307-02-01 02/10/15 TAS 100 TAP-317-02-01 09/02/ 15 MTAMIDADE CQUNTY 4 NUA No.; 20-0701.02 Expiration Date; 12/01/25 Approval Date; 11/05/20 Page 3 of 7 0 .r LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shingles shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION o: 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115. 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail `A', attached. 5. Nailing shall be in compliance with Details W, attached. LABELING • Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below: MIAMI-DADE COUNTY � BUILDING PERMIT REQUIREMENTS As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. • 0 NOA No.: 20-0701,02 MIA • ADE coin Expiration Date, 12/01/25 r Approval Date: 11/05/20 _.. Page 4 of 7 v DETAIL A HERITAGE, HERITAGE WOODGATE, HERITAGE PREMIUM, AND HERITAGE PROLINE TITAN XT All dimensions are in inches. 5TH COURSE 4TH COURSE 3RD COURSE _ 2ND COURSE 23 1ST COURSE 29 r, Fu11 -- DETAIL B HERITAGE, HERITAGE WOODGATE, HERITAGE PREMIUM, AND HERITAGE PROLINE TITAN XT SHINGLE FIG.1 FASTENING PATTERN All dimensions are in inches 39.3/8" �1 71/2 73/B' �I 7'/z" 7'/�' --> < i 3-1 /4" ................f........»......s......... ....f................................. Exposure � NOA No.: 20.0701.02 MIAMI•�AoscoU TY Expiration Date. 12/01/25 �' ' � Approval Date: 11/05/20 Page 5 of 7 DETAIL B (CONTINUED) HERITAGE, HERITAGE WOODGATE, HERITAGE PREMIUM, AND HERITAGE PROLINE TITAN xT SHINGLE FIG. 2 ALTERNATE FASTENING PATTERN • i i -- r i r r Common i3i3nci ' — FASTENERS ' (Cyyr, VCIO r+ 39-3!8" HERITAGE SHINGLE (TUSCALOOSA, AL) R& 3 ALTERNATE FASTENING PATTERN HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. I OR FIG. 2. VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE, M1RMI•DADE COUNT i E i W NOA No.: 20-0701.02 Expiration Date: 12/01/25 Approval Date: 11/05/20 Page 6 of 7 • ,r J :... HERITAGE PROLINE TITAN XT SHINGLES FIG. 4 ALTERNATE FASTENING PATTERN HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG. 2. VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE, Nail Zone Paint Lines END OF THIS ACCEPTANCE NOA No.; 20-0701.02 i. MDADEcaurr Expiration Date: 12/01/25 I + +■ Approval Date.11/05120 Page 7 of 7