HomeMy WebLinkAboutAPPROVED flat roofNEMo I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 0647$
(203) 262-9245
. .. .. ....
ENGINEER EVALUATE TEST CONSULT
APOC, sub of Gardner Asphalt Corp.
4161 E. 71h Avenue
Tampa, FL 33605
(813) 248-2101
SCOPE:
Evaluation Report 1-GG-18-001s0118-1114
FL26482-R6 (NON,,HVHZ)
Date of Issuance: 02/27/2018
Revision 4: 12/17/2020
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Gardners Roof Underlayments, for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.10
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prod uct(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility locations). NEMO ETC.,, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated"' may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon
request, a copy of this entire Evaluation Report shall
be
provided to the user by
the manufacturer
or its distributors
and shall be available for inspection at the job site at
the
request of the Building
Official.
This Evaluation Report consists of pages 1 through 7.
Prepared
IL
TN
�+ •• J... r ` T
Robert J.M.
Nieminen Pa Ed � .•, { �* The facsimile seal appearing was authorized by Robert
Florida Registration No. , � 'fC� � �� - ���, �� :�,��** �?,��� ierninen P.E. on 1 17 0 . Thisdoes not serge as
: ± an e ectronically signed document.
CERTIFICATION ATIO F INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
. Robert i ieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued,
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved ire the approval process of the
product.
.5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nie in n, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
92019 NEMO ETC, LLC
RoOFING COMPONENT EVALUATION:
4.1
4.2
r
NEMO I etc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: GardnerO Roof Underlayments, as produced by Gardner Asphalt Corp., have
demonstrated compliance with the following sections of the 7' Edition (2020) Florida Building Code through
testing in accordance with the following Standards.
Limitations / Conditions of Use set forth herein.
Section
1504.3.1
1 07.1.1, 1 07. .4� 1 7. .9. R90 .1.11
R95.+.
1 7.1.1.1(2&3, Exception), 1507.1.1.1(5)
R905.1.1.13, Exception), R90.1.1.(5
107.1.1.1&3, Exception), 107.1.1.1)
R9 5.1.1.1(2&3., Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
1 07. .3 R9 . .3
TA
Entity
MEMO
PRI
(TST5878)
PRI
(TST5878)
PRI
(TST5878)
PRI
(TST5878)
PRI
(TST5878)
PR!
(TST5878)
PRI
(TST5878)
PRI
(TST5878)
PRI
(TST5878)
PRI
(TSTS878)
PRI
(TST5878)
PRf
(TST5 8 78)
PRI
(TST5878)
PRI
(TST5878)
PRI
(TSTS878)
PRI
(TSTS878)
UL,
LLC. (QUA9625)
UL,
LLC. (QUA9625)
Compliance is subject to the Installation Requirements and
Property
Wind resistance
Material standard
Tear strength
Tensile strength
Liquid water transmission
Material standard
Accelerated Weathering
Examination
Traceability
ASTM D226 (physicals)
ASTM D 197 , D479
ASTM D1970, D49
FRSA TRI, ASTM D4798, TAS 103
AST! D, D45331 D4869
ASTM DJ. D4533, D4869
ASTM D197 , D479
ASTM D479
ASTIR D13, TS 103
UL1897
Criticality, ASTM D17
ASTM D903, D1 70
ASTM D123, TAS 103
ASTM D1970
ASTM D1623, D4798
Quality Assurance
Quality Assurance
Standard Year
U L1897 2015
ASTM D1970 2015
ASTM D433 201S
ASTM D5035 2011
ASTM D4869 2016
FRSA/TRI, Sixth Edition 2018
ASTM D4798 2011
Reference
Date
FBC Cross -Listing
12/10/2020
GGi-176-02-01
9/26/2016
GGI-178-02-01
10/24/2016
GGI-194-02-01
4/19/2017
G G I-196-02-01
7/26/2017
GGI-132-02-06
12/11/2017
GGI-199-02-02
12/11/2017
GGI-178-02-01
1/26/2018
GG I-178-02-D2
1/25/201$
GG I-201-02-01
1/26/2018
GG f-212-02-01
5/9/2018
GGi-209-02-01
5/18/2018
GGI-211-02-01
6/6/201$
GG I-202-02-01
8/9/2018
G G I-243-02-01
5/29/2019
397T0016
12/15/2020
397T0O18
12/16/2020
Service Confirmation
02/12/2020
Florida BC1S
Current
Product Material Standard Plank Us Description
Gardners Gard -Lock ASTM D1970 Springville, nominal -mil thick, , glass -fiber reinforced, polymer
AL modified asphalt, granulated self -adhering underlayment
Weather -Armor" FT 3 FRSA/TRI09-18 Springville, nominal -rail thick, , self -adhering membrane f elastic
Tile Underlaym nt AL polymers, bitumen and polyester and glass
reinforcement
NEMO ETC, LLC
Certificate of Authorization #32455
7TH EDITION 2 FBC NON-HVHZ EVALUATION
ardnerO Roof nderlayment ; 1) 4 - 1 1
Evaluation Report I- - -0 1. .1 -i 4
FL 4 -(NON-HVHZ)
Revision 4: 12/17/2020
Purge 2 of 7
4.3
4.4
4.5
4.7
.9
.10
.11
NEMO I etc.
Product
Material Standard
Plant(sl
I Des ri do
Eagle -Armor by Apoc
FI T I 09-1
Springville,
nornin l 0-rail thief, self -adhering membrane f elastic
AL
polymers, bitumen and polyester and glass
reinforcement
TriBuilt Fleece Tile
FRS TRI 09-1
Springville,
nominal 0-mil thief, self -adhering membrane of elastic
Underlayment
AL
polymers, bitumen and polyester and glass
reinforcement
We then- r or HT 2
ASTM D1970
Springville,
nominal -rail thick, self -adhering mernbrane composed
High Temp Premium
AL
of elastic polymers, bitumen, glass reinforcement and a
Roof Underlayment
cross -laminated sleet surface, gran in color
Weather-ArmorO HTI
ASTM D1970
Springville,
nominal 0 -rail thick, self -adhering membrane composed
sed
High Temp Premium
ILL
of elastic polymers, bitumen, glass reinforcement and a
Roof and rlayment
cross -laminated sheet surface, black/yellow in color
W th r- rm rO sB-1
ASTM D1970
Springville,
nominal 0-nail thick, glass -fiber reinforced, polymer
self-B ndO Roof
AL
modified asphalt, granulated self -adhering un l rl yment
undorlayment
ASTM D1970
Springville,
nominal -rail thick, glass -fiber reinforced, polymer
TriBuilt Ice and dater
and rlayment
AL
modified asphalt, granulated self -adhering underlayment
ator-s in TM Synthetic
1 07.1.1,1(2& ,
Hangzhou,
synthetic roof and rlaym nt comprised cf layers of
Roof Underlayment
Exception), 1 07.1.1.1 ,5
China
p lyol fin film
9 5. 1. ■ 1(i& 1
Exception), R90.1.1.1(5
G for shin 1 T"^
1507.1.1.1(2& ,
G u1j"arat,
synthetic roof underlayment comprised of layers of
Synthetic Roof
Exception), 150.1.1.1(
India
polypropylene film
Underlayment
. . 1. 1 jp
Exception), R905.1.1.1
11 eath r- rmor
1507.1.1.1(2& ,
Hangzhou,
hybrid underlay ent comprised of two layers of
r ssOver X-L
Exception), 1507.1.1.1(5)
China
polyolefin and polyester synthetic fabric with a lager of
Premium Hybrid Roof
F 90 .1.1.1( & {
modified bitumen between the two
Und rl ym nt
Exception),, R905.1.1.1(5)
S.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire
classification.
Refer
to
FBC
1505 for requirements and
(imitations regarding roof assembly fire classification.
Refer to FBC
2603
for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Gardners Roof Underpayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
NEMO ETC, LL
Certificate of Authoriation #32455
TH EDITION o IBC NON-HVHZ EVALUATION
GardnerO Roof Und rlaym nt ; (813) 4 - 101
Evaluation Report 1-GG-18-001.02.18-R4
FL25482-R5 (NON-HVHZ)
Revision 4; 12/17/2020
Page 3 of 7
)NEMO I etc.
5.6 Allowable Roof Corers:
TABLE 1: RoOF VE l PTI IS
F `e tfo :
1507.2
15073
. .fir1507.7
150Z8 & 1507.9
1507.5
Clay and Concrete Tile
Metal
.date r
j �/�}
U del ent
Asphalt
Panel ..[%
Slate -Type
Wood Shingles
Mechanical
dhe i�r �
�
Shingles
orShakes
Attach
Set
Shingles
Shingles
■ ES
rdn rO Gard Lock
YES
NO
NO
No
YES
(joint strips, 1507.1.1.3
Weather -Armor' FT Tile Underlayment
YES
YES
Yes
YES
YES
YES
(joint strips, 1.507.1.1.
Y
YES
Eagle -Armor bar po
YES
YES
YES
YES
(joint strips, 1507.1.1.
(Se P_ 5.6.1
R90.1.1.3)
Yes
YES
TriBuilt Fleece Tile Underlayment
YES
YES
YES
YES
(joint trips, 1S07.1.1,
. .
R905.11. )
Weather -Armor' HT1 High Temp Premium
YES
Roof Undrlyrt
YES
NO
YES
YES
(joint strips, 1507.1.1.3
R905.1.1.3)
1 th r- rr orO HT1 High Temp Premium
YES
Roof Undrlrrnt
YES
NO
IVY
YFS
YE
(joint strips, 1507.1.13
R905.1.1.3)
YES
TriBuilt High TernTernp Metal Underlayment
YES
NO
NO
YES
YES
Ooint strips, 15 7.1.1.
90.5.1.1.3)
Weather-ArmorSB-1 Self-BonO Roof
YES
Undrlymnt
YES
NO
NO
NO
YES
(joint strips* 1507.1.1.
YES
TriBuilt Ice and Water n d rl a yment
YES
NO
NO
NO
YES
joint strips, 1507.1.1.3
R905AA.3�
tor--S inTI Synthetic Roof Underlayment
YES
NO
No
YES
YES
NO
ator--Sly 10"' Synthetic Roof
Underlayment
YES
NO
NO
YES
YES
NO
I' t r-rm r Crossover X- L Premium
Hbrid hoof lJndt��rT�er�t
YES
!
'ES
YES
5.6.1 Adhesive -set file is limited to use of the following underfayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT TILE -ADHESIVE OM I ANTI IS-
erl yment
Adhesive
Florida Product Approval
Weather -Armor' FT1 Tile
Underlayment, Eagle -Armor by Apoc or
TriBuilt Fleece Tile Underlayment
DAP "Touch'n Seal St rm and Roof Tile he l*e"
FL14506
Dupont "Tile Bond" Roof Tile d i e"
FL22525
I P Adhesives `}Pol Set' H-1 "
FL6332
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC
Certificate of Authorization #32455
TH EDITION j FHC NON-HVHZ EVALUATION
GardnerO Roof nderla ment ; (813) 48-101
Evaluation Report 1- -1 - 1.0 .18- 4
L 4 2- (NON-HVHZ)
Revision 4: 12/17/2020
Page 4 of
)NEMO I etc.
5.7 Allowable Substrates:
TABLE Z: SUBSTRATE OPTIONS
Underlayment Substrates
Gardners Gard -Lock, Weather -Armor' FTC Tile Underlayment, Eagle -Armor by Apoc, TriBuilt Fleece Tile
Underlayment, Weather -Armor° HT2 High Temp Premium Roof Underlayment, Weather -Armor° HT3 High Plywood
Temp Premium Roof Underlayment, TriBuilt High Temp Metal Underlayment, Weather -Armors SB-1. Self -
Bond° Roof Underlayment, TriBuilt Ice and Water Underpayment
Weather -Armory FT3 Tile Underlayment, Eagle -Armor by Apoc, TriBuilt Fleece Tile Underlayment, Weather -
Armor° HT2 High Temp Premium Roof Underlayment, Weather -Armor' HT1 High Temp Premium Roof OSB
Underlayment, TriBuilt High Temp Metal Underlayment
Weather -Armor° FT3 Tile Underlayment, Eagle -Armor by Apoc, TriBuilt Fleece Tile Underlayment, Weather -
Armor"' HT2 High Temp Premium Roof Underlayment, Weather -Armor° HT' High Temp Premium Roof Structural
Underlayment, TriBuilt High Temp Metal Underlayment. *Note: minimum 73°Fambienf application concrete*
temperature for structural concrete.
5,8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under file roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Instc1lation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design
Pressure = -52.5
pst:
Deck:
Min. 1S/32-inch
plywood to meet project requirements to satisfaction of Authority Haying
Jurisdiction.
Primer: None
Underlayment: Weather -Armor' FTC Tile Underlayment, Eagle -Armor by Apoc or TriBuilt Fleece Tile
Underlayment, self -adhered.
#2 Maximum Design Pressure = -135.0 psf:
Deck; Min. 19/32-inch APA span -rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: None.
Underlayment: Weather -Armor' FT 3 Tile Underlayment, Eagle -Armor by Apoc or TriBuilt Fleece Tile
Underlayment, self -adhered.
#3 All other direst -deck, adhered underpayment systems beneath the roof systems carry a Maximum Design
Pressure of -45 psf.
NEMO ETC., LLC
Certificate of Authorization #32455
!"EDITION (2020) FCC NON-FiVtiZ EVALUATION
Gardners Roof UnderlaymentS; (813) 248-2101
Evaluation Report 1- -1- 01. .1 -R4
FL26482-R6 (NON-HVHZ)
Recision 4: 12/17/2020
Page 5 of 7
NEMO I etc.
S-9 Exposure Limitations:
TABLE * ExPOSURE UmITATIONS
Prepared Roof Cover
Maximum
Underlayment
Exposure
I�,��� Type
(days)
for- kin" Synthetic Roof Underlayment, t r- kin 1 TM Synthetic Roof
Underlayment, Weath r- rm o r HT High Temp Premium of
Underlayment or Weather -Armor' Crossover X-L Premium Hybrid Roof
Mechanically attached
30
Underlayment
rdner Ord -LE, Weather-rmr B-1 If -Bond f
Underlayment, TriBuilt Ice and Water r Underlayment
Mechanically attached
90
Weather -Armor"' HT3 High Temp Premium of Underlayment., TriBuilt
High Temp Metal Underlayment
1`Ihnla!!r attached
180
Adhesive -set tile
(Polyset' - )
Weather-ArmorO FTC Tile Underlayment, Eagle -Armor by oc TriBuilt
Adhesive -set the
Fleece Tile Underlayment
(Tile Bonn' Roof Tile Adhesive or
90
Touch 'n seal StormBond Roof Tile
Adhesive)
Mechanically attached
180
5.10 Tile Skppage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum rood slope shall be as follows. These slope limitations can only be exceeded by using battens daring
loading of the roof tiles.
TABLE : TILE SLIPPAr.3E UmITATIONS FOR L I E T-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Weather-rrr FTTiIe Underlayment, Eagle-
Armor by Apoc, TnBu Elt Fleece Tile U nd rlayment
Flat or Lid
Max. 1-tilt stack
6:12
6.1 Gardners Roof Underlayments shall be installed in accordance with Gardner° Asphalt Corp. published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable.
6.3
Gardners Gard -Lock, Weather-ArmorO HT High Temp Premium Roof Underlayment,, Weather -Armor° HT 3 High
Temp Premium Roof Underlayment, TriBuilt High Temp Metal Underlayment, Weather -Armory SB-1 Sellf-BondO
Roof Underlayment or TriBuilt Ice and Water Underlayment:
6.3.1 Shall be'Installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905,1,1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Multi -Ply Underlayment 5vstems:
Weather-ArmorO HT3 High Temp Premium Roof Underlayment or TriBuilt High Temp Metal Underlayment
followed by Weather-ArrnorO FV Tile Underlayment, Eagle -Armor by Apoc or TriBuilt Fleece Tile Underlayment
(per Section 6.4) is allowable for use under mechanically attached prepared roof systems. Limits of use are those
associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment
system is desired.
NEMO ETC, LLC
Certificate of Authorization #3245.5
7N EDITION 2 2 NON-14VHZ EVALUATION
ardn rO Roof Und rlayment ; (813) - 1 1
Evaluation Report 1- -1g- 1. .1 - R4
L- (NON-HVHZ)
Revision 4; 12/17/2020
Page 6 of
6.4
6.4.1
6.4.2
6.5
Weather-ArmorO FT'Tile Underlayment, Eagle -Armor by Apoc or TriBuilt Fleece Tile Underlayment:
Non -Tile, Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1-1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905,1,1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.11,
Tile Applications:
Shall be installed in compliance with requirements for aSelf-Adhered Membrane in the FRSA/TRI Florida Nigh
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for file staging limitations.
Gator-Skin T" Synthetic Roof Underlayment, Gator-Skin lOTM Synthetic Roof Underlayment or Weather -Armor
CrossOver CX-L Premium Hybrid Roof Underlayment:
6.5.1 5ha!l be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exceptian),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905,1.1.1(2, Exception), R905.1.1.1(3,, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.5.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be asset forth in FBC 1507.1.1.1 or FBA
Residential R905.1.1.1.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation af'this
product.
Contact the named Q,4 entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations haying met codified material standards.
UL, LLC. (QUA9625); (414) 248-6409; karen.buchmannul.com
NEMO ETC, LL
Ce rti ica to of A u th o riz a don ##3 2455
-END OF EVALUATION REPORT —
74" EDITION (2020) FBC NON-HVHZ EVALUATION
Gardners Roof Underlayments; (813) 248-2101
Evaluation Report 1- -1 - 1. .1 -
FL26482-R6 (NON-HVHZ)
Revision 4: 12/17/2020
Page 7 of 7