Lucas A. Turner, P.E.
FL PE #58201
Evaluation Report – CWS-466E
August 19, 2020
Product Description: Series 3500 Aluminum Single Hung Window, Non Impact, 56” x 91” unit
size 57 1/4” x 92 1/4” flange size, 1/8 or 3/16 Monolithic or IG Glass, Equal Split or Oriel
Manufacturer: Custom Window Systems, Inc. 1900 SW 44th Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above-listed product per the requirements of
FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements
of the 7th Edition (2020) Florida Building Code outside the High Velocity Hurricane Zone. The
product testing standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, PE, at 2428 Old Natchez Trc Trl, Camden, TN
2) Approval drawing CWS-466E, signed and sealed by Lucas A. Turner, P.E.
3) Test Reports NCTL-210-3586-1, -1A, -2, and -2A, from National Certified Testing
Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E.
a. Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-05
4) Supplemental Calculations to support CWS-466E, signed and sealed by Lucas A. Turner,
P.E.
Installation: Units must be installed according to approval document CWS-466E.
Limitations of Use: This product:
• May be used in O/X Equal Split or Oriel configuration in sizes up to 56” x 91” unit size or 57
1/4” x 92 1/4” flange size, with max. glass daylight heights of 58 5/16” for fixed panel and 42
7/8” for sash
• Achieves design pressures as indicated in comparative analysis tables in CWS-466E
• Is non-impact and requires the use of shutters in windborne debris regions
• May not be used in the High Velocity Hurricane Zone
• Requires 1/8 or 3/16 monolithic or IG glass, with E1300 design pressure limitations as shown
in the comparative analysis tables in CWS-466E
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a
financial interest in Custom Window Systems or in any company manufacturing or distributing
products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I
acquire, a financial interest in any other entity involved in the testing or approval process of this
product.
URNER
ENGINEERING &
CONSULTING, INC.
T
2428 Old Natchez Trace Trail
Camden, TN 38320
Ph. 941-380-1574
FBPE C.O.A. #29779