HomeMy WebLinkAbout6500 Las Palmas Way - Solar PV Plans F R O N H o O R-1 T U Inverter Type: Enphase IQ7-60-2-US O O PV Panel: (18)Q.PEAK DUO BLK-G5 320 F Racking: Q-Rail Light Total Wattage: 5,760W Ground Access Point Roof Type: Composition Shingles Wind Load: 7 to 20 Deg Fastener Type: Use Roof Tech Mini's 3' Access Pathway Sheet Index H S-1 Cover Sheet/ Site Plan S-2 Detail E-1 One - Line T T S-IA Mounting Plan lJ General Notes: S O -Enphase IQ7-60-2-US Micro Inverters R-1 are located on roof behind each module. E # Modules (18) -First responder access maintained and Pitch: 18' from adjacent roof. -MSP on interior Azimuth: 180' -Wire run from array to connection is 40 feet. wall behind Meter 5'-6" Utility Meter 1 03'-3" StJN TEC Layout Subject to Change Based on Site Conditions SOAR EYE G L3, Mak3n6Yaur Soler Day B:lgheer!!' 7300 Bryan Dairy Rd STE 400 Godwin Engineering and Donnie C .`.................HPD G, Seminole, FL 33777 Godwin * Design, LLC ,*: No 1360 '•:*= 8378 Foxtail Loop 2021 .05.1 gip'• STATE OF :•'� 727-571-4141 System meets the requirements of NFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec Pensacola, FL 32526 � �.,S�ONA„E?•O• Meets All Editions of Florida Fire Prevention Code 7th Edition Customer Info: D. Chad Godwin, PE 14:21 :48 oa Legend Chad@godwineng.com µo g Chimney 1 0 0 1 0 5- R ANY ELECTRONIC COPIES First responder access Satellite I st Responder Access ❑0 Utility Meter O Vent Pipe Represents all Fire Clearance p David Olivo Date: 5/7/2021 NPV Disconnect including Alternative methods m as Palmas Way of 36" unobstructed as per 6500 L Pal W D b MT Section R324 of the 2018 IRC yrawn y� Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2018 Port St. Lucie, FL Revised b International Residential Code) - 2nd Printing modified by the FL Building Standards , 2018 34952 Rev D International Energy Conservation Code, County of St. Lucie Code, 2017 National Electric Code.) Rev Date: Page: S-1 Coin ass for Aerial 4 NF General Notes: Install will be done to Manufacturer Spec - Roof Tech Mini's are secured to rafters .•"�Nn E'op @ 24 O.C. in Zone 1, @ 24 O.0 in Zone 2e, NOB1980 ;..= &@ 24" O.0 in Zone 2r. Godwin Engineering and s,a,E using (2) M5 x 60mm stainless steel Lag bolts. Design, LLC '°NA'EN 8378 Foxtail Loop �n�..�.s -No Mount to be installed in zone 3. Pensacola, FL 32526 Donnie GC Godwin - Subject roof has One layer. D. Chad Godwin, PE 2021 .05.11 - All penetrations are sealed. Chad@godwineng.com '00'05- 14:22:02 Roof Section Pitch Roof Rafter and Spacing Overhang Notes: EC skrq T BdL Ap @µ@PC3Y R1 4/12 2"x4" g 24 O.C. 12" Truss M Along Yo u r Snlar oyy H rl h!n r!!! per ne-Desi d as ASCE7-16 Customer Info: 7300 Bryan Dairy Rd STE 400 g p Inverter Type: Enphase IQ7-60-2-US Seminole, FL 33777 -Roof Height 15 PV Panel: (18) Q.PEAK DUO BLK-G5 320 727-571-4141 -Per 2020 FBC, the Roof Mounted PV System Racking: Q-Rail Light David Olivo Date: 5/7/2021 will be subject to the following design criteria: Total Wattage: 5,76OW 6500 Las Palmas Way Drawn by: MT Design Wind Speed(Vult) - 160mph 3 sec gust, Roof Type: Composition Shingles Port St. Lucie, FL Revised by: Wind Load: 7 to 20 Deg Rev #• 00 Exposure Category - C Fastener Type: Use Roof Tech Mini's 34952 Rev Date: Page: S-2 SOLAR PV SYSTEM EQUIPPED 3/8IN MIN.TEXT WITH RAPID SHUTDOWN DUAL POWER SUPPLY INVERTER OUTPUT CONNECTION: SOURCES:UTILITY GRID AND DO NOT RELOCATE THIS TURN RAPID PV SOLAR ELECTRIC SYSTEM OVERCURRENT DEVICE Enphase Output Ckt Per String SHUTDOWN SWITCH T 3/16 IN MIN.TEXI THE'OFF"POSITION T SHUT DOWN PV To Overcurrent Protection Device SYSTEM AND REDUCE SHOCK HAZARD IN THE W N I AC Max Output Current 11 ARRAY. 1 POWER SOURCE OUTPUT CONNECTION: Enphase IQ Trunk Cable Photovoltaics: AC Max Output Current * 1.25% 13.8 DO NOT RELOCATE THIS OVERCURRENT WARNING: DEVICE Q12-240 (18) Q.PEAK DUO BLK-GS 320 Overcurrent Protection A 20 PHOTOVOLTAIC SYSTEM DEDICATED SOLAR PANEL DO #12AWG THHN-THWN-2 No. of Current Carrying Cond <4 TH RAPID SHUTDOWN EQUIPPED WITH NOT CONNECT ANY OTHER LOADS UL 9703 Inverters: Conductor Gauge AWG 10 (18) Enphase IQ7-60-2-US Micro Inverters Enphase Total Output Ckt Grounding Conductor AC Max Output Current D 18 W * #10 AWG THN for Home runs to be bare#8 Awg Circuits: AC Max Output Current 1.25/0 22.5 (1)Line 1 (1) circuit of(11) Modules Overcurrent Protection(A) 30 (1)Line 2 NEMA 3R (1) circuit of(7) Modules No. of Current Carrying Cond <4 Per Circuit #8 AWG THwN Junction Box Roof Maximum Inverters Per 20A Circuit (16) Conductor Gauge (AWG) 10 (1)EGC Black-Ll Inside @ least 3/4"Conduit(tbd on site) Red-L2 NEC LABEL NOTES: Green-Ground 1. THE WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. Load Side Connection 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8"AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC WARNING Busbar Rating 200 REQUIREMENTS OF THE AUTHORITY HAVING ELECTRIC SHOCK HAZARD Main Breaker Size 200 JURISDICTION. DO NOT TOUCH TERMINALS. Bus Rating*1.2-Main Break Size 40 -- TERMINALS ON BOTH THE LINE AND LOAD SI GIZED IN Max Allowable Load Side 40 Load Size Breaker Size 30 • • • WARNING:PHOTOVOL • Mai 200A n Service POWER SOURCE M RATED AC OUTPUT CURRENT: 18A NOMINAL OPERATING VOLTAGE: 240VAC 200A Bus Enphase Combiner Utility PV AC Disco Donnie C 30A Non-Fused Disconnect Godwin Engineering and Godwin Per circuit .. (1)-20A Breaker Manual Lockable Disconnect Design, LLC No 81360 � : �.. 2Czaov 30A 8378 Foxtail Loop 2021 .05AM' STATE OF :'4U 15A Breaker for Envoy �Oc� Disconnect Pensacola, FL 32526 11 ;S-<.. . Solar Combiner Box N D. Chad Godwin, PE #x-IQ-AMI-240 14:22:11 Located Adjacent to Utility Meter Chad@godwineng.com emoE E. G '00'05- A�rELE�ao"1��oPIEs #10 AWG THWN GEC (2)Hot (1)Neutral #8 AWG EGC in @ least 3/4"Conduit Typically (;Sulm TEG S0LAR EF4ERGY Making Your Solar oaf BrIghte r!!I Load side connection Per 705.12(B)(2)(3)(b) 7300 Bryan Dairy Rd STE 400 System meets the grounding requirements of NEC 690.43 Use Matching or equivalent approved breaker if derating Seminole, FL 33777 Including the label below Note: GEC NOTES Customer Info• 727-571-4141 -All wirin to meet the 2017 NEC and - Ungrounded System per 690.41(A)(4) g - GEC must be installed per 250.64 Date: 5/7/2021 Florida electric codes. - GEC must be continuous un-spliced or irreversibly spliced from MT In Case of Emergency Call David Olivo Inverter Type: inverter to existing service ground system or continuous from the y:Drawn b Enphase IQ7-60-2-US 30A Disconnect arrays to the existing service ground system. 6500 Las Palmas Way PV Panel: SUri TeC Solar Energy -Type of conduit to be determined - GEC must be min#8 AWG d installed in conduit Y Revised b . (18) at 7r�7-57 1 —^ 1 ^ 1 - If GEC is not in conduit,it must be#6 min per NEC 690.54 Port St. Lucie, F''L, Rev #: 00 Q.PEAK DUO BLK-G5 320 1. G J 1 `t 1`t 1 on site by contractor. Total wattage: All Labels&Markings for photovoltaic system will be 34952 Rev Date: 5,760W Install will be done to Manufacturer Spec reflective and meet all requirements for NFPA 11.12 Page: E-1 Q-Rail Light 9 39'-0" 9'-4" Splice Bar 6 Roof Tech Mini's 60 Q-Mount Mids 32O L L L L 0 L L L Q-Mount Ends/End Caps 8 o L L 15�- 1 Combiner 1 L L L L Q-Mount Ground Lugs 2 Q.PEAK DUO BLK-G5 320 18 L L L L L L L L 5'-6" Enphase IQ7-60-2-US 18 71-711 Meter Main R- 1 3'-3" 30A Non-fused Disconnect 1 # Modules (18) y Plans satisfy zones FBG1510.7.1 30A Breaker 1 Install will be done to Manufacturer Spec 20A Breakers 2 Pitch: 18° Ao�oo .,, Enphase Combiner Box 1 �`r3fiF Azimuth: 180° Godwin Engineering and o�..T,a,E Design, LLC 8378 Foxtail Loop . ..o. a Pensacola, FL 32526 ion n ie C Godwin D. Chad Godwin, PE Chad@godwineng.com 2021 .05.11 '00'05- 14:22:22 sung TEc .riOLAR C.fE Fi.;. Making Your S.U,Ilea Tr r3;_•r"' Max cantilever is 8" as per manufacturer spec. 7300 Bryan Dairy Rd STE 400 Zone 1: Customer Info: Seminole, FL 33777 Max Cantilever = Max Span * (3)=24"*(3)=8" Inverter Type: Enphase IQ7-60-2-US 7inole, L 41 33 Max cantilever is 8" as per manufacturer spec. PV Panel: (18) Q.PEAK DUO BLK-G5 320 Zone 2e: Max Cantilever = Max Span * ( Racking: Q-Rail Light David Olivo Date: 5/7/2021 3)=24"*(3)=8" Max cantilever is 8 as per manufacturer spec. Total Wattage: 5,760W 6500 Las Palmas Way Drawn by: MT Zone 2r: Roof Type: Composition Shingles Port St. Lucie FL Revised by: Max Cantilever = Max Span * (3)=24"*(3)=8" Wind Load: 7 to 20 Deg Rev #: 00 Fastener Type: Use Roof Tech Mini's 34952 Rev Date: No mount to be installed in zone 3. Page: S-1 A powered by MECHANICAL SPECIFICATION a` DUO Format 66.3 in x 39.4in x 1.26 in(including frame) surases4mG ,,.5 a52.5mp4 (1685mm x 1000 mm x 32mm) Weight 41.2 1 bs(18.7 kg) 4.Gmpaamg p..mrarrl•(a,Smm) b,•,• Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology Back Cover Composite film 3oaa• 51mm Frame Black anodized aluminum : ® 55.4•a000mm> Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in (70-85mm x 50-70mm x 13-21 mm),decentralized,IP67 U U 41Mou tlngalah(GET41L4 •"�"-g••" Cable 4mm2 Solar cable;(+)z43.3 in(1100 mm),(-)a43.3 in(1100 mm) -{I-1zc l5xm4G GETAILA G.sS>a5m.a H Connector Multi-Contact MC4,IP68 o.5G5•u4.5mm)I I(L-W-w ELECTRICAL CHARACTERISTICS Q. PEAK DUO 300= , POWER CLASS 30D 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC1(POWER TOLERANCE+5 W/-OW) Power at MPP' PMPP [W] 300 F 305 1 310 315 F 320 t NTUM SOLAR J e MODULE Short Circuit Current' Igo [A] 9.72 9.78 9.83 9.89 9.94 Open Circuit Voltage' VGG IV] 39.48 39.75 40.02 40.29 40.56 Current at MPP IMPP [A] 9.25 9.31 9.36 9.41 F 9.47 Voltage at MPP VMPP IV] 32.43 32.78 33.12 33.46 33.80 The new Q.PEAK DUO BLK-G5 solar module from Q CELLS impresses with Efficiency' rl I%] >_17.s >_1s.1 >_18.4 >_18.7 >_19.o its outstanding visual appearance and particularly high performance MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOV on a small surface thanks to the innovative LI,r�)1-Mlil BUD Technology. Power at MPP PMPP [W] 224.1 227.8 231.E F 235.3 1 239.1 Q.ANTUM's world-record-holding cell concept has now been combined £ Short Circuit Current 1, [A] 7.83 7.88 7.92 7.97 8.01 with state-of-the-art circuitry half cells and a six-busbar design, thus Ourrepen nt at Voltage VGg [A] 37.28 37.32 37.66 37.41 38.17 Current at MPP IMPP [A] 7.28 7.32 7.37 7.41 7.45 achieving outstanding performance under real conditions - both with Voltage at MPP VMPP Iv] 30.78 31.11 31.44 31.76 32.08 low-intensity solar radiation as well as on hot, clear summer days. 'Measurement tolerances PM :L3%;I�,.V°Ct5%atSTC:l000W/m2,2st2°C,AM1.5GaccordingtolEC60904-3.2800W/m2,NMOT,spectrumAM1.5G Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY „G y.,Iao _ --T-----r - ----� G ;e °CELLS At least 98%of nominal power during first year. Higher yield per surface area, lower BOS costs, higher power ;;;;o;;1e� a;u. Thereafter max.0.54%degradation per year. o W a B5 -------------------------- At least 93.1%of nominal power up to 10 years. ,m I I classes, and an efficiency rate of up to 19.3 /o. W At least 85%of nominal power up to 25 years. - � w I All data within measurement tolerances. -- --r-----r-----i------------- r INNOVATIVE ALL-WEATHER TECHNOLOGY e „ Full warranties in accordance with the warranty 5 Optimal yields, whatever the weather with excellent low-light terms of the Q CELLS sales organization of your respective country. wo 4ao Goo No ]mo and temperature behavior. < IRRADIANCE[W/m'] zi QN ]5 S ENDURING HIGH PERFORMANCE sws I—Ign.."I,h.10w �la �.m i- 2g YEARS Typical module performance under low irradiance conditions in 14 .hhm.hgh•ap,d�na�__tymzm4(. 1:Ga�mL..2o14) comparison toSTC conditions(25°C,1000W/mz). o Long-term yield security with Anti LID Technology, 0CELLS Anti PID Technology', Hot-Spot Protect and Traceable Quality Tra.QTM. TOP a® TEMPERATURE COEFFICIENTS N, Temperature Coefficient of IGc a [%/Kl +0.04 Temperature Coefficient of VGr [%/K] -0.28 0 0 EXTREME WEATHER RATING Temperature Coefficient of PMPP y [%/Kl -0.37 Normal Operating Module Temperature NMOT [°F] 109 t5.4(43 t3°C) �I AHigh-tech aluminum alloy frame, certified for high snow 2018 PROPERTIES FOR SYSTEM DESIGN m (5400 Pa) and wind loads (4000 Pa) regarding IEC. Maximum system voltage vSYS Iv] 1000(1 EC)/1000(UL) Safety Class 11 Maximum Series Fuse Rating [A DC] 20 Fire Rating C(IEC)/TYPE 1(UL) CY A RELIABLE INVESTMENT M Max.Design Load,Push/Pull(UL)2 [lbs/ftzl 75(3600 Pa)/55(2667 Pa) Permitted module temperature -40°F up to+185°F pv nursEMc ` Inclusive 12-year product warranty and 25-year Cluality,Tested r Y• jl on continuous duty (-40°C up to+85°C) linear performance guaranteez. ;„"�„ n - '� Max Test Load,Push/Pull(UL)r [lbs/ftzl 113(5400Pa)/84(4000Pa) 2 see installation manual STATE OF THE ART MODULE TECHNOLOGY ID.40032587 "� �.. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Q.ANTUM DUO combines cutting edge cell separation UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 32 EC 61215:2016;IEC 61730:2016,Application class A 21 and innovative wiring with Q.ANTUM Technology. APT test conditions according to Number of Pallets per53'Trailer 30 IECITS 62804-1:2015, V ��® Number of Pallets per High Cube Container 26 0 method B(-1500V, 168 h) D E C E C Pallet Dimensions(L x W x H) 69.3 in x 45.3 in x 46.9 in iF 2 See data sheet on rear for further c UL1"�us (1760mm x 1150mm x 1190mm) information. 256a1 THE IDEAL SOLUTION FOR: Pallet Weight 1415lbs(642kg) - NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use - Rooftop arrays on of this product. y ®residential buildings Hamvha Q CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us Engineered in Germany OCELLS Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V The high-powered smart grid-ready Max DC short circuit current(module Ise) 15 A 15 A Overvoltage class DC port 11 11 Enphase Enphase IQ 7 MicroTM and Enphase IQ 7+ MicrOTM DC port backfeed current 0 A 0 A Q 7 and I Q 7 dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak Microinverters Part of the Enphase IQ System,the IQ 7 and Maximum umcontinutput 240 VA 290VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L-L)voltage/ranger 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'"', Enphase IQ Battery'"", and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'"" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype(I07-60.2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) Connector type(I07-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: • Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure • Class 11 double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor • UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break Complies with advanced grid support,voltage and disconnect required by NEC 690. _ frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. U *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/su000rt/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. E N P H AS E® To learn more about Enphase offerings,visit enphase.com E N PHASE. To learn more about Enphase offerings,visit enphase.com u �./ ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 f P QRai [" — Fully Integrated Mounting and Racking System Fast, Simple Installation : It Just Clicks The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar QCIickTechnologyTM designers and installers. Combined with Quick Mount PV's industry-leading waterproof mounts, QRail offers a The universal mid and end clamps use patented QClick r- v1. complete racking solution for mounting solar modules on any roof. technology to simply"click" into the rail channel and _ remain upright, ready to accept the module.The - Easily design array configurations with the QDesign software pre-assembled clamps fit virtually all module frames and it J« application. Generate complete engineering reports and calculate require no extra hardware, eliminating pre-loading and , ti! a precise bill of materials for all the mounting, racking and reducing installation time. UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP • accessories needed for a complete solar array. 2 2 clamps for modules from 2 clamps for modules from 30-45mm or38-50mm thick 30-45mm or38-50mm thick click! Comprehensive, One-Source Solution Installing is as easy as 1-2-3 QRail, together with Quick Mount PV's waterproof mounting products, provides the benefit of a single-sourced, QSplice"Technology seamlessly integrated rooftop installation that works with all roof types — composition/asphalt shingles, QRail's innovative internal QSplice installs in seconds, requiring no flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof tools or screws. Simply insert QSplice into the rail and slide the other _ rail on to create a fully structural, bonded splice.An external splice is QSPLICE attachment system for maximum flexibility. also available. 1 - Superior Strength and versatility QRail is engineered for optimal structural performance. The system �r - is certified to UL 2703, fully code compliant and backed by a 25-year HEAw '' Installs in se — erequired warranty. QRail is available in Light, Standard and Heavy versions to -match all geographic locations. QRail is compatible with virtually all STANDARD - Fully Integrated Electrical Bo n d i n g IGMT modules and works on a wide range of pitched roof surfaces. Modules The QRail system provides an integrated electrical bonding path, ensuring that all exposed metal arts and QRails come in two lengths— y P g g P g p p can be mounted in portrait or landscape orientation in standard or 168 inches(14 ft)and 208 inches(17.3 ft) the solar module frames are electrically connected. All electrical bonds are created when the components are shared-rail configurations. Mill ond Block Finish installed and tightened down. GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chad@godwineng.com May 10, 2021 To: St. Lucie County Building Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Olivo- Residential PV Roof Mount Installation 6500 Las Palmas Way Port St. Lucie, FL 34952 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 7th Edition, FBC ASCE 7 Min. Design Loads for Buildings &Other Structures Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V it) - 160mph 3sec gust, Exposure Category-C The PV System consist of the modules,railing, and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 1/z"plywood decking and 2"x 4" roof trusses 24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Quickmount Q-rail Light railing and the RT mini mounts.The attachments can be attached up to 24" apart in roof zones 1, 2e, &2r.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with 2 x M5 x 60mm stainless lag screws directly to the roof truss. Please see attached documents and contact me should you have any questions. JI'lApuG��ly Donnie C Sincerely, Godwin No 81360 '= D. Chad Godwin, PE 81360 f STATE o 2021 .05.11 Exp. 02/28/2023 14:22:35 '00'05- o. o0 ASCE 7-16 CHAPTER 29 WIND LOADS-Rooftop Solar Panels Minimum Design Loads-Part 1:Enclosed(Hip,h<60ft,7*<0<20°) Risk Category II Table 1.5-1 Load Types Load,PSf Basic Wind Speed(Ult) Figure 26.5-1B Dead Load,D 3 Wind Speed(asd) 124 IBC 1609.3.1 Weight of Ice,Di 0 Roof Angle 18 Earthquake,E 0 Effective Wind Area 17.88 W 26.20 Fluid,F n/a Wind Load Parameters Flood Load,Fe n/a Wind Directionality Kd 0.85 Table 26.6-1 Lateral Earth psi,H n/a Exposure Cat. B,C,or D C Section 26.7 Live Load,L n/a Topographic factor K,t 1.00 26.8 or 26.8.2 Roof Live,Lr n/a Ground Elevation Factor Ke 1.00 Table 26.9-1 Rain,R n/a Velocity Exposure Coefficient K, 0.85 Table 26.10-1 Snow,S Array Edge Factor YE 1.50 29.4.4 *Modules are considered Exposed Self-Straining,T n/a Solar Panel Equalization Factor Y. 0.70 Fig.29.4-8 Wind,W see talc Velocity Pressure qh 28.41 psf qh=0.00256 K,K,,KdK,V7 Wind-on-Ice,Wi n/a Mean Roof Height h 20.00 ft h2 5 in Not,10in(height above roof) 0.4h 8.00 ft 2h2 10 In min distance array shall be from the roof edge,Gable Ridge,or hip ridge least horizontal dim 360 in 0.25 in min gap betweenall panels but no 6.7ft 10%of least horizontal dim 3.00 ft dl 1.00 ft Horizontal distance orthogonal to panel edge Roof Zone Set Back a 3.00 ft d2 0.25 ft Horizontaldistancefromedgeofonepanelto theneare-digeinthenextro h/B 0.67 0.5h 10.00 ft 1.51-p 8.25 ft Figure 30.3-2G(Hip roof,h<60ft,7°<0<20*) Zone 1 2r 2e 3 GC, -1.30 1 -1.70 1 -1.70 -2.20 uplift GCpj 0.70 1 0.70 1 0.70 1 0.70 1 downward p=gh(GCp)(-/j(Ya) -38.73 -50.65 -50.65 -65.54 psf uplift 29.4-7 p=gh(GCp)(7'E)(Ya) 20.85 20.85 20.85 20.85 psf downward 29.4-7 Design Calculations for the Use of Attachment to Roof Truss/Rafter Module Length C(Lp) 5.50 ft Module Width B 3.25 ft Module Area A 17.88 ft2 Total Design Load(Uplift) Pde,ign -35.73 -47.65 -47.65 -62.54 psf Total Design Load(Downforce) Pdmign 20.85 20.85 20.85 20.85 psf Design Load per Module Tup -638.67 -851.68 -851.68 -1117.95 Its Tup=A*Pde,ign Design Load per Module Tdawo 372.77 372.77 372.77 372.77 Its Tan=A*Pde,ign Distributed Load(Uplift) Pdi,t.up -98.26 -131.03 -131.03 -171.99 plf Tup/B*2 Distributed Load(Down) PuM.Down 57.35 57.35 57.35 57.35 plf Tdn/B*2 Railspan Between Anchor Points L ft Point Load per Mount(Uplift) R -196.51 -262.06 -262.06 -343.98 Ibs Point Load per Mount(Down) R 57.35 57.35 57.35 57.35 Ibs 1 2r 2e 3 Table 1.1-Pullout Value,Max Span,Max Cantilever-RT Mini Specific Gravity G 0.55 0.55 0.55 O.5 Table 11.2A,NDS 2005,page 68(SYP) Diameter of Lag Screw D 1/4 1/4 1/4 1/4 In Pullout Value of W 259.5802 259.5802 259.5802 259.5802 lbs/in W=1800 G'f7 D'f4 #of Lag screws 2 2 2 2 Thread Length Td 1.75 1.75 1.75 1.75 In Table L2,NDS 2005 Design Pullout Value per Mount Wt 447 447 447 447 Wt=W*#of Lags*Td SAFTEY FACTOR SF 2.27 1.71 1.71 1.30 Calculation:SF=WIR(Uplift) 1 2r 2e 3 Maximum Cantilever from Last attachment Max Cantilever M 8 8 8 8 in Max rail span*33% ,1 pDrrGo"I Donnie C No 81380 Godwin O1. STATE OF2021.05.11 p�S`p�ONA tE�aG� '00'05- 14:22:43