OWENS CORNING ROOFING & ASPHALT RHIOROOF GRN
Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 Evaluation Report 3m-OC-20-FBCER.01-RI FL32344-R1 Date of Issuance: 06/04/2020 Revision 1: 12/10/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7' Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof® GRN LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 `�4s�,uar+rrrry,ri. :..: • fib,,, .:: ,��?. The facsimile seal appearing was authorized by Robert i,S�ykayi Nieminen, P.E. on 12/10/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 MEMO ETC, LLC ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof® GRN, as produced by Owens Corning Roofing and Asphalt, LLC, has demonstrated compliance with the following sections of the 71 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro a Standard Year 1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015 / R905.1.1, R905.2.8.2 Entity Examination Reference Date PRI(TST5878) ASTM D1970 OCF-293-02-03 12/20/2017 PRI(TST5878) ASTM D1970 OCF-253-02-02 12/21/2017 Owens Corning Quality Control Declaration 07/15/2020 PRI (QUA9110) Quality Control Service Confirmation 05/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current � •se i o Product Material Standard Plant(s) Description RhinoRoof® GRN ASTM D1970 (Table 1)1 Brentwood, NN Granule -surfaced, self - Houston, TX adhering, roof underlayment 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 RhinoRoof GRN may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 1 Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance of RhinoRoof GRN. NEMO ETC, LLC Evaluation Report 3m-OC-20-FBCER.01-R1 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL32344-Rl Owens Corning RhinoRoof® GRN Revision 1: 12/10/2020 Page 2 of 3 5.6 5.7 5.8 NEMO etc. Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 Clay and Concrete TILE Metal Wood Underlayment Y Asphalt Slate or Slate- Mechanical Adhesive- Shingles Panels Shingles g Type Shingles g Shingles Shakes Attach Set Yes RhinoRoof® GRN Yes No No No No Yes (joint strips, 1507.1.1.3 1 R905.1.1.3) Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) RhinoRoof" GRN self -adhering Deck / sheathing None Plywood Attachment Limitations: For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) RhinoRoof® GRN Mechanically attached 30 6.1 RhinoRoof GRN shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 1 RhinoRoof® GRN: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report 3m-OC-20.FBCER.01-Ri Certificate of Authorization #31455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL32344-R1 Owens Corning RhinoRoof" GRN Revision 1: 12/10/2020 Page 3 of 3