HomeMy WebLinkAboutKSM NUCLEAR DENSITY TEST RESULTHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 June 2, 2021 CONTRACTOR: JOB LOCATION: PERMIT #: To Whom it may concern, Ve C41 t ENGINEERING i117AYL AND TESTING Regal Plumbing 681 SW McCollough Ave Port St Lucie, FL 34953 1071 South Header Canal Road Fort Pierce, Florida 2103-0980 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 214082-1d/MH/bm Enclosed, please find the nuclear density test results performed on the compacted foundation fill at the above referenced project. Should you have any questions, please feel free to contact our office. Respectfully, This item has been electronically signed and sealed by Julie Keller, P.E. R. Lic. I'll, on the date stated directly to the right using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Digitally signed by Julie Keller Date: 2021.06.02 10:42:11 Julie E. Keller, P.Q.4;QQ ent PE# 68366 06/02/21 Email: office@myregalplumbing.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headquarters 1W C IL t ENGINEERING Mailing 11345 U.S. Highway 1 L--,V L AND TESTING PO Box 78-1377 Sebastian, FL. 32958 IIIL1 IL Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way C.A.# 5693 Sanford, FL. 32771 KSMengineering.net SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 DATE TESTED: June 1, 2021 KSM JOB #: 214082-1d/MH/bm NUC # 630 PERMIT #: 2103-0980 Nuc Model: MC-IDR-P Nuc Serial #: 30630 CONTRACTOR: Regal Plumbing JOB LOCATION: 1071 South Header Canal Road Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.W. 0" - 12" 50 110.1 112.1 98.2% 2 N.W. 50 108.0 96.3% 3 Center 50 109.3 97.5% 4 S.E. 50 108.7 97.0% 5 N.E. 50 109.0 97.2% Soil Description: Brown Sand with Shell Fragments In Place Moisture: 6.9 Proctor Optimum Moisture: 11.0 Proctor Max. Dry Density: P.C.F. 112.1 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Disclaimer: Contractor is responsible to maintain Minimum Requirement the tested area in the condition that KSM for Unstaked Foundation completed the indicated passed compaction test. KSM is not responsible if the tested area has been Julie E. Keller, P.E. President altered from the approved inspected condition. PE# 68366 6/2/2021 Email: office@myregalplumbing.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headquarters 1W C IL t ENGINEERING Sebastian, FLIg329 81 i11-J LVL AND TESTING Orlando 723 Progress Way Sanford, FL. 32771 SOIL COMPACTION REPORT ASTM D 1557 DATE TESTED: June 1, 2021 PERMIT #: 2103-0980 CONTRACTOR: Regal Plumbing JOB LOCATION: 1071 South Header Canal Road Fort Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 214082-1d/MH/bm 114.0 I I I I I I I W E I I I I I I I I I113.0.._...._.._._.._..._.._..�.._...._.._. G I I I I I I I I H T 112.0 ._.._..�.._..�.._. _..�.._..�.._.._, I I I I I I I PI ....... _. _.._�._.._..I_.. �.._.._. C I I I I I I I I I I I I I I F 110.0 _..i.._.._.I._.._ I _..i.._.._i._.._..i _..i.._.._. • I I I I I I I I 109.01._.._..F.._..-T.._.._I._.._..r—.._..-T.._.._. D R I I I I I I I I Y108.0 4—.._.. _.._._.._..._.._..�.._...._.._. I I I I I I I I 107.0.._...._.._1._.._...._..-4.._.._1._.._...4.._..—, 6 7 8 9 10 11 12 13 14 Moisture - % of Dry Weight Soil Description: Brown Sand with Shell Fragments Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 112.1 Julie E. Keller, P.E. President PE # 68366 6/2/2021 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE