Loading...
HomeMy WebLinkAboutEvaluation Report; 5V Panel— RECEIVED MAY L 9 2021 Permitting Department R EV1 iE;—za L� g"" U ,q 5t. r_vcte County E �Rd T OF UNIO =5VPA�NEL' DE CO PLEANC r:`26 T. ILUCIE COUNTY FLORIDA BUILDING CODE 7TH EDITION (2020) FLORIDA PRODUCT APPROVAL F112 Col FL 20484.1=R2 ROOFING METAL ROOFING Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 3664543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Load Span Table (1 Page) Report No. C2401-1 Date: 10.10.2020 aa���,oBaace;�eey �z'°,"oCKAL./iv No 62240 rr STpSE OF O •• \ ;"gj.E�49Gf� '_ FL 20484.1-R2 C2401-1 10.10.2020 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 15/32" thick APA rated plywood or min. 3/a" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1. Required for new construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2 Design Uplift Pressure: 71.0 psf at fastener spacing of 24" o.c. (Factor of Safety = 2) 169.0 psf at fastener spacing of 6" o.c. Panel Attachment: #10-15 x 2" long wood screw with washer. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. At interior max 12" o.c. across panel width through panel rib At panel ends max 6" o.c. across panel width through panel flat and rib Minimum fastener length of 1.5" for new construction. For existing construction, fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress FL 20484.1-R2 C2401-1 10.10.2020 Page 3 of 3 design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T197-16, Reporting Date 5/12/16 PANEL OVER NEW UNDERLAYMENT ROOF PANEL SEE DETAIL 2 PANEL FASTENER SEE DETAIL 1 SPACING PER ALLOWABLE )( UPLIFT LOAD TABLE JV EXISTING UNDERLAYMENT EXISTING SHINGLES DECK ATTACHMENT AND PLYWOOD 15/32" THICK (MIN.) (OPTIONAL) (OPTIONAL) SUPPORTS MUST BE DESIGNED AND INSTALLED BY OTHERS mill. ZA_ rvwU jwrir_R/,JUiai/ TRUSS AT MAX. 24" O.C. #10-15 X 2" LONG WOOD SCREW WITH WASHER NEW UNDERLAYMENT EXISTING UNDERLAYMENT (OPTIONAL) DETAIL 1 #10-15 X 2" LONG WOOD SCREW WITH WASHER NEW UNDERLAYMENT 1 6 EXISTING UNDERLAYMENT I (OPTIONAL)DETAIL 2 TYPICAL PANEL INSTALLATION X-SECTION MIN 26 GA. PANEL �- EXISTING SHINGLES (OPTIONAL) a � - PLYWOOD5/32" THICK (MIN.) GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OFN IF za BS. Z ��" R. 8 m A PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS IN 26 GA. PANEL SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM EXISTING SHINGLES (OPTIONAL) REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. PLYWOOD C2401-1 15/32" THICK (MIN.) SHEET N0. OF UNION CORRUGATING COMPANY ' 5V Panel Uplift Loads (Mn 26 ga.) Description Fastener Spacing along Panel Length (in) Allowable Uplift Load (psf) Coverage width: 24" Panel Fasteners #10-15 hex head screws with sealed washer Panel fasteners spaced at 12" o.c. across panel width through ribs. 6 169.0 8 158.1 10 147.2 12 136.3 14 121.7 16 106.5 18 94.7 20 85.2 22 77.5 24 71.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 918 492 5992 oc:'%;; a 8V4.l9 OCKAL�0�r �9 5 ......, �VG, 'sari No 622.40 C STATE OF ; '1 , a0 Al 1;0. -10.2G2G Bala Sockalingam, Ph.D., P.E. FL 62240