1149 ABTco Road
North Wilkesboro, NC 28697
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Allura Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. VERT/ LAP/ SHAPES/ SOFFIT, titled: "Fiber Cement Vertical Panel/
Lap Siding/ Shapes/ Soffit Installation Details", sheets 1 through 8 of 8, prepared by Plycem USA, LLC, dated
01/24/2002, with the last revision 2 dated 04/26/2018, signed and sealed by Robert Nieminen, P.E., bearing the Miami -
Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -
Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, North Wilkesboro, NC, model/
series and the following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product
Control Approved" is to be located on each siding unit and per FBC 1709.10.2 and 1709.10.3 on soffit units.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA # 14-1022.03 and consists of this page 1 and evidence pages E-1, E-2
and E-3, as well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
F.
�> NOA No. 18-0222.08
Expiration Date: April 24, 2023
Approval Date: June 21, 2018
Page 1
Plycem USA, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA'S
A. DRAWINGS "Submitted under NOA # 14-1022.03"
L Drawing No. IOSBC00164B0000-E through IOSBC00164B0007-E, titled: Fiber
Cement Panel/ Plank, Fiber Cement Random Square Shapes and Fiber Cement Soffit
Installation Details Steel/ Wood Stud Construction", sheets 1 through 8 of 8, prepared
by Plycem USA LLC, dated 01/24/2002, with the last revision E dated 01/19/2015,
signed and sealed by Jose D. Mitrani, P.E.
B. TESTS "Submitted under NOA # 02-0503.01 "
Report Test Date Signature
1. AT-0142883.01 ASTM C1185 03/11/03 A. N. Reeves, P.E.
2. RT41168-98 ASTM C1185 02/27/02 B. I. Ogawa, P.E.
3. HETI 014056 TAS 202 08/27/01 H. M. Medina, P.E.
4. HETI 014058 TAS 202 08/28/01 H. M. Medina, P.E.
5. HETI 014 021 TAS 202 06/06/01 H. M. Medina, P.E.
6. HETI 014000 TAS 202 06/01/01 H. M. Medina, RE
7. HETI 014036 TAS 203 06/22/01 H. M. Medina, P.E.
8. HETI 014072 TAS 202 09/06/01 H. M. Medina, P.E.
9. HETI 014035 TAS 202 06/22/01 H. M. Medina, P.E.
10. HETI 014023 TAS 202 06/01/01 H. M. Medina, P.E.
11. HETI 014060 TAS 202 08/28/01 H. M. Medina, P.E.
12. HETI 014 022 TAS 203 06/01/01 H. M. Medina, P.E.
13. HETI 014024 TAS 203 06/01/01 H. M. Medina, P.E.
14. HETI 014033 TAS 203 06/14/01 H. M. Medina, P.E.
15. HETI 014057 TAS 203 08/27/01 H. M. Medina, P.E.
16. HETI 014059 TAS 203 08/29/01 H. M. Medina, P.E.
17. HETI 014061 TAS 203 08/28/01 H. M. Medina, P.E.
18. HETI 014073 TAS 203 09/06/01 H. M. Medina, P.E.
C. CALCULATIONS "Submitted under NOA # 08-0213.05"
1. Anchor verification calculations and structural analysis, complying with FBC-2007,
dated 04/11/2008, prepared, signed and sealed by Jose D. Mitrani, P.E.
"Submitted under NOA # 024503.01 "
2. Fasteners calculations prepared by Jose D. Mitrani, sheets 1 through 19, signed and
sealed by Jose D. Mitrani, P.E.
Carlos M. 'CTtrera, P.E.
Product Control Examiner
NOA No. 18-0222.08
Expiration Date: April 24, 2023
Approval Date: June 21, 2018
E-1
Plycem USA, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # 14-1022.03"
1. Bill of sale dated 02/01/2014.
"Submitted under NOA # 11-1014.08"
2. Statement letter of code conformance to 2007 and 2010 FBC (including ASTM
C1186, Type A) issued by Jose D. Mitrani, P.E., dated 12/11/2011, signed and sealed
by Jose D. Mitrani, P.E.
"Submitted under NOA # 08-0213.05"
3. No financial interest letter issued by Jose D. Mitrani, P.E., dated 04/11/2008, signed
and sealed by Jose D. Mitrani, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 18-0222.08
Expiration Date: April 24, 2023
Approval Date: June 21, 2018
E-2
Plycem USA, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. VERT/ Lap/ Shapes/ Soffit, titled: "Fiber Cement Vertical Panel/ Lap
Siding/ Shapes/ Soffit Installation Details", sheets 1 through 8 of 8, prepared by
Plycem USA, LLC, dated 01/24/2002, with the last revision 2 dated 04/26/2018,
signed and sealed by Robert Nieminen, P.E.
B. TESTS
1. None.
C. CALCULATIONS
L Anchor calculations prepared by Nemo etc., dated 04/26/2018, signed and sealed by
Robert Nieminen, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of no financial interests and of code conformance toedition
(2017) FBC, issued by Nemo etc., dated 04/25/2018, signed and sealed by Robert
Nieminen, P. E.
2. Laboratory testing contract letter issued by QAI Laboratories, dated 03/13/2018,
signed by Michael Brunk.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 18-0222.08
Expiration Date: April 24, 2023
Approval Date: June 21, 2018
E-3
48"
120"
3 Studs @ 16" o.C.
TNote: Plywood Fasteners not shown for clarity
I II � it I II II
II II I II
II I I II II If II
11 I I°I I°I I I 11
IL
ITW
Buildex 5-12 #8 x 1-5/8" x 0.315" HD
corrosion resistant ribbed bugle screws
spaced 6" o.c. around the perimeter of the
panel and intermediate vertical studs (Typ.)
�" CDX Grade Plywood
Sheathing Mechanically
Fastened To Studs with
#Sx1 4." Rock —on SDS
Fasteners (By Others)
Minimum
Edge Distance
Screws @ 6" o.c. (Typ.)
2" Minimum Corner Distance
2" Minimum from Gorner
SEE DETAIL A
A -
3-5i13"x 1—�'x0.031 "
Weatherproofing 20 Gage Steel Studs
Per 14042 Of F.B.C.
ITW Buildex S-12 #8 x 1-5/8" x 0.315" HD
Acorrosion resistant ribbed bugle screws
llura
Fiber Cement Panel DETAIL A spaced 6" o.c. around the perimeter of the
panel and intermediate vertical studs
General Notes
1 • Wall receiving Fiber Cement Panels shall be checked for structural adequacy (By Others)
2. Walls shall be weather proofed as described in section 1404.2. of the F.B.C.
Product Description
Allura panel material is a non —asbestos fiber
Cement product tested In accordance with ASTM
C-1185 and meeting the requirements of the
Florida Building Code
Dimensions
Width Length Thickness
48" 8119%10' 6"
Grade Design Pressure Rating
ywood Sheathing Installation on: Design Pressure:
echanically Fasted Steel Studs —89 PSF
Studs Impact Resistont—Panels installed over plywood sheathing
atherproofing
1404.2.
F.B.C.
20 Gage
Steel Studs
era Fiber
cement Panel
SECTION B-B
Installation Notes
1. All installation shall be done in conformance with
this Notice of Acceptance, the manufacturer's installation
recommendations and the requirements of the
Florida Building Code.
2. Metal studs on, to which Allura Fiber Cement Panels will
be installed shall be designed by a Registered Professional
Engineer or Licensed Architect per the F.B.C. and the
requirements of this N.O.A.
i
3. Panels are to be installed vertically, ovoidingi horizontal
ts, over %" CDX grade APA rated plywood supported by
20 gage x3—%"x1—%" steel studs spaced a maximum
of 16" o.c.
4. Allura fiber cement panels shall be fastenedwith ITW
Buildex S-12 #8 x 1-5/8" x 0.315 HD corrosion resistant
ribbed bugle screws.
5. Fasteners shall be placed 6" o.c. around the perimeter of the
panel and intermediate vertical studs, driven through the plywood
sheathing into the studs. All joints shall be over studs and screws
shalI have a minimum edge distance of �4" and minimum
clearance of 2" from the corners.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 18-0222.08
Expiration D to 04/24/2023
By
Miami-Da`de Product Control
N EMOletc.
fNGINEE0.IEVALUATE I TEST I CONSULT I CERTIFY
353 Christian Street, Unit#13
Oxford, CT 06478
TEL: 203 262 9245
FAX 203 262 9243
WWW.NEMOETC.COM
Drawn by:
L Cadena
P-E Review
�MINE/V /!i�
�e�Q�GF'NSEo0
0
L
of �. C7
O • ``4.
0 _ . �P .e
1�all�ra
15055 Wood ham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
1149 ABTco Road
Wilkesboro NC 28659
Rev
Description
Date
0 I
2017 FBC
04.24. [ 8
02
HETk0I-105
.04.26.18
FIBER CEMENT VERTICAL
PANEL INSTALLATION DETAILS
STEEL STUD CONSTRUCTfON
Dnwin& Sheet:
VERT-1
�to4/2612018 1 Of 8
Smle
fee
NONE
48"
120"
96"
Note: Plywood Fasteners not shown for clarity
Studs @ 16" o.c.
Minimum
B "--Vertical Direction Edge Distance
6dx2" long galvanized common wire nails
spaced 6" o.c. around the perimeter of the
panel and intermediate vertical studs (TVD.)
V
CDX Grade P
Sheathing Mechani
Fastened To Stud:
#8x1 Y4" Rock -on
Fasteners.(By Oth
Weatherproofing
Per 1404.2 Of F.I
Allura
Fiber Cement Panel
f�eneral Notes
DETAIL A
Nails @ 6" o.c. (Typ.)
2" Minimum Corner Distance
2" Minimum from Corner
Product Description
Ahura panel material is a non —asbestos fiber
Cement product tested In accordance with ASTM
C-1185 and meeting the requirements of the
Florida Building Code
SEE DETAIL A
ADimensions
Width Length Thickness
48" 8',9',10, Is"
2x6 Wood Studs with. a
Specific Gravity of 0.55 or More
6dx2" Long Galvanized
Common Wire Nails spaced
6" o.c. around the perimeter
of the panel and Intermediate
vertical studs
1. Wall receiving Fiber Cement Panels shall be checked for structural adequacy (By Others)
Z. Wails shall be weather proofed as described in section 1404.2. of the F.B.C.
j Design Pressure Ratina
CDX Grode Design Pressure:
/ Plywood Sheathing Installation on: 9
Mechanically Fastened Wood Studs —76 PSF
To Studs
Impact Resistant —Panels installed over �" plywood sheathing
Installation Notes
1. All installation shall be done in conformance with
Weatherproofing this Notice of Acceptance, the manufacturer's installation a am
Per 1404.2 Of F.B.C. recommendations and the requirements of the
i Florida Building .Code.
2. Wood studs on to which Allura Fiber Cement Panels will be
Installed shall be designed by a Registered Professional
i 2x6 Wood Studs Engineer or Licensed Architect per the F.B.C. and the
l requirements of this N.O.A.
1 Allura Fiber 3. Panels are to be installed vertically, avoiding horizontal
Cement Panel joints, over CDX grade APA rated plywood supported by
2x6 wood studs with a specific gravity of 0.55 or more spaced
B—B a maximum of 16" o.c. "
4. Allura fiber cement Panels shall be fastened with 6dx2
long galvanized common wire- nails. .
5. Fasteners shall be placed 6" o.c. around the perimeter of the
panel and intermediate vertical studs, driven through the plywood
sheathing into the studs. All joints shall be over studs and nails
shall have a minimum edge distance of Y4" and 'minimum
clearance of 2" from the corners.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 18-0222.0B
Expiration ate 04/24/2023
ey
Miami—Dide Product Control
N EMO letc.
ENGINEER�EVALUATE I TEST I CONSULT ICERTIFY
353 Christian Street, Unit#13
Oxford, CT 06478
TEL• 203 262 4245
FAX: 203 2b2 9243
WWW.NEMOEMCOM
Drawn'by:
L. Cadena
P.E. Review
1�allura
Ply°sm USA LLC.
15055 Woodham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
1149 ABTco Road
Wilkesboro
C 28659
Rev # Description Date
O1 2017 FBC 04.24.18
IN
Tt�e:
F{BER CEMENT VERTICAL
PANEL INSTALLATION DETAILS
WOOD STUD CONSTRUCTION
°ivnig Sheet
VERT-2 r
D8C04/24R016 L OI
Sale
NONE
IN
Tt�e:
F{BER CEMENT VERTICAL
PANEL INSTALLATION DETAILS
WOOD STUD CONSTRUCTION
°ivnig Sheet
VERT-2 r
D8C04/24R016 L OI
Sale
NONE
B
A120"
sheathing into the studs (typ)
5.g" CDX Grade Plywood
Sheathing Mechanically
Fastened To Studs with
#8x1 Y4" Rock -on SDS
.Fasteners
Weatherproofing
Per 1404.2
Of F.B.C.
Allura Fiber Cement
Lap. Siding
General Notes
20 Gage Steel Studs
iITW Buildex S-12 #8 x 2-1/4" x 0.315" HD
corrosion resistant ribbed bugle screws
D ETAI L A fastened in the overlapping area < or=8" o.c9
vertically and 16" o.c. through the plywood
sheathing into the studs
1. Wall receiving Fiber Cement Lap Siding shall be checked for structural adequacy (By Others)
2.. Walls shall be weather proofed as ,described in section 1404.2 of the F.B.C.
1
Product Description
Allura panel material is a non -asbestos fiber
Cement product tested In accordance with ASTM
C-1185 and meeting the requirements of the,
S E E D ETAI L A Florida Building Code
Dimensions
Width Length Thickness
< 94 12' Vie"
�" CDX Grade
Plywood Sheathing Design Pressure Rating
Mechanically Fastened Installation: Design Pressure:
To Studs —67. PSF
Impact Resistant —Planks installed over plywood sheathing
Install.otion Notes
All installation shall be done in conformance with
Weatherproofing this Notice of Acceptance, the manufacturer's installation
Per 1404.2. recommendations and the requirements of the
Of F.B.C. Florida Building Code,
2. Metal studs on to which Allura Fiber Cement Lap Siding will
,20 Gage be installed shall be designed by a Registered Professional
Steel Studs Engineer or Licensed Architect per the F.B.C. and the
requirements of this N.O.A.
A(IUra Fiber 3. Lap Siding are to be installed horizontally commencing from the
C ent La Siding bottom course of a wall with 1 Y4" wide laps at the top of the
p g plank. The vertical joints must be over framing members.
SECTION B-B Optional PVC butt joint inserts are used for on -stud jointing.
4. Lap Siding are to be installed over %" CDX grade APA rated
plywood supported by 20 gage x3-Vx1-3V steel studs
spaced a maximum of 16" o.c.
5. Allura Fiber Cement Lap Siding shall be fastened through the
overlapping planks with ITW Buildex S-12 #8 x 2-1 /4" x 0.315"
HD ribbed bugle screws.
6. The fasteners shall be placed in the overlapping area < 8" o.c.
vertically and 16" o.c. horizontally through the, plywood sheathing
into the studs. Screws . shall have a minimum edge distance of 3/4"
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 9 8-0222_111R
Expiration Date 04/24/2023
Miami- aide Product Control
N EM O letc.
ENGINEERIEVALUATEI TEST I CONSULT I CERTIFY
353 Christian Street, Unit#13
Oxford, CT 06478
TEI.: 203 262 9245
FAX 203 262 9243
WWW.NEMOETC.COM
by.
L Cadena
P.E Review
��a��ii a rrrrii
NIEA4/ '',*,.
s
;o��Q:•GENSF'•F�Y'%
Q:• N 59A 6 '•
:u
pF : tt
E
R �O0 C)
allura
Plycam USA LLC.
15055 Woodham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
1149 ABTco Road
Wilkesboro NC 28659
Rev #
Description
Date
01
2017 FBC
04.24.18
FIBER CEMENT LAP SIDING
INSTALLATION DETAILS
STEEL STUD CONSTRUCTION
(FACE FASTEN)
Dawing Sheet:
LAP- I
04/24/20I8 3 Of 8
sue.:
NONE
48"
Sdx2 �" long galvanized common wire nails
fastened in the overlapping area < or = 8" o.c.
vertically and 16" o.c. through the plywood
sheathing into the studs (typ.)
�" CDX Grade Plywood
Sheathing Mechanically
Fastened To Studs with
#8x1 Ya" Rock —on SDS
Fasteners (By Others)
Weatherproofing
Per 1404.2
Of F.B.C.
Cement Lap Siding
Allura Fiber
General Notes
120"
Studs @ 16"
DETAIL A
SEE DETAIL A
A
Plywood Fasteners not shown for clarity
CDX Grade
PI wood Sheathing
Mechanically Fastened
To% Studs
i
Weatherproofing
Jer 1404.2.
Of F.B.C.
2x6 Wood Studs
,Ilurp Fiber
ement Lap Siding
SECTIOW B-B
Minimum
Distance
2x6 Wood Studs with a
Specific Gravity of 0.55
8dx2—)�" Long galvanized common wire nails
fastened in the overlapping area < or = 8" o.c.
vertically and 16" o.ce through the plywood
sheathing into the studs (typ.)
1. Wall receiving Fiber Cement Lap Siding shall be checked for structural adequacy (By Others)
2. Walls shall be weather proofed os described in section 1404.2. of the F.B.C.
t C
NEMOletc.
ENGINEER[ EVALUATE I Tyr I CONSULT I CERTIFY
Product. Descri tlOn 353 Christian street, Unit#13
1' Oxford, CT 06478
Allura panel material is a non —asbestos fiber
Cement product tested In accordance with ASTTEL: 203 262 9245
C-1 185 and meeting the requirements of the FAX 203 262 9243
Florida Building Code IWWW.NEMOETC.COM
Dimensions
Width Length
<9 Ya" 12'
t
ThicSk�ness
�7 6"
besign Pressure Rating
Installation: Design Pressure:
Wood Studs —115 PSF
Impact Resistant —Planks installed over �'e" plywood sheathing
Install
ation Notes
1. All installation shall be done in conformance with
this Notice of Acceptance, the manufacturer's installation
recommendations and the requirements of the
Florida Building Code.
2. Wood studs on to which Allura Fiber Cement .Lap Siding will
be installed shall be designed by a Registered Professions(
Engineer or Licensed Architect per the F.B.C.'and the.
requirements of this N.O.A.
3. Lap Siding are to be installed horizontally commencing from the
bottom course of a wall with 1 Y4" wide laps at the top of the'
plank. The vertical joints must be over framing members. o Optional PVC butt joint inserts are used for ,n—stud jointing.
4. Lap Siding are to be installed over %" CDX grade APA rated
plywood supported by 2x6 Wood studs with a specific gravity
of 0.55 or more spaced a maximum of 16"; o.c.
5. Allura Fiber Cement Lap Siding shall be fastened through the
overlapping planks with 8dx2 2" long galvanized common wire
nails.
6. The fasteners -shall be placed in the overlapping area < 8" o.c.
vertically and 16" o.c. horizontally through the plywood sheathing
into the studs. Screws shall have a minimum edge distance of 3/4"
PRODUCT REVISED
as complying with the Florida
Building Code
NOA—No. 18-0222.08
Expiration � e 04/24/2023
y �..
Miami -Da _ Product Control
Drawn
L Cadena
P.E. Review
I EM/N 41! if
cc
IL
dF : W
��. SATE •,�
O R.••��•�44*
;.
1allura
Plycern USA LIC.
15055 Wood ham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
1149 ABTco Road
Wilkesboro NC 28659
Rev #
Description
Date
01
2017 FBC
04.24. ( 8
Title:
FIBER CEMENT LAP SIDING
INSTALLATION DETAILS
WOOD STUD CONSTRUCTION
(FACE FASTEN)
onw,"g Sheet
LAP-2
018 4 Of S
Smle:
NONE
48"
{TW Buildex S-12 .#8 x2 Y4"x0:315" HD
corrosion resistant ribbed bugle screws
fastened in the overlapping area above the top
Df the keyway and 16" o.c. horizontally through
the plywood sheathing into the studs. Fasteners
vertical spacing not to exceed 8"_c•
5/8" CDX Grade Plywood
Sheathing Mechanically
Fastened To Studs with
#8x1AY4" Rock —on SDS
Fasteners (By Others)
Weatherproofing
Per 1404.2
Of. F.B.C.
Allura Fiber Cement Shapes
General Notes
Studs
Fasteners not shown for clarity
20 Gage Steel Studs
ft
SEE DETAIL A
�" CDX Grade
Plywood Sheathing
Mechanically Fastened
To Studs
Product Description
Allura .random square material is a non —asbestos Fiber
Cement product tested In accordance with ASTM
C-1185 and meeting the requirements of the
Florida Building Code
Dimensions
Width Length Thickness
S 16" 4' 5(6"
Design Pressure Ratina
Installation on: Design Pressure:
Steel Studs —67 PSF
Impact Resistant —Planks installed over plywood sheathing
Installation Notes
;dtherproofing 1. All installation shall be done in conformance with
r 1404.2 this Notice of Acceptance, the manufacturer's installation
F.B.C. recommendations and the requirements of the
Florida Building Code.
20 Gage 2. Metal studs on to which Allura Fiber Cement Random
Steel Studs Square Shapes will be installed shall be designed by a
ara Fiber Registered Professional Engineer or Licensed Architect
ment Shapes per the F.B.C. and the requirements of this N.O.A.
S ECT(0 N B - B
ITW Buildex S-12 #8 x2—Ya"x0.315" HD
corrosion resistant ribbed .bugle screws
fastened in the overlapping above the top
of the keyway and 16" o.c. horizontally through
D ETAI L A the plywood sheathing into the studs
1. Wall receiving Fiber Cement Random Square Shapes shall be checked for structural adequacy
(By Others)
Z. Walls shall be weather proofed as described in section 1404.2. of the F.B.C.
3. Shapes are to be installed horizontally
commencing from the bottom course of a wall. The vertical
joints must be over framing members. Overlap dimension is
4. Shapes are to be installed over �" CDX grade
APA rated plywood supported by 20 gage x 3-%"x1-%" stee
studs spaced a maximum of 16" o.c.
5. Allura Fiber Cement Shapes shall be fastened
through the overlapping planks with ITW Buildex
S-12 #8 x2 X%0.315" HD corrosion resistant ribbed bugle
6. The fasteners shall be placed in the overlapping area above
top of the keyway and 16" o.c. horizontally through the plyv
sheathing into the studs. Screws shall have a minimum edge
distance of 1'4". Vertical spacing not to. exceed 8" o.c.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 18-0222.08
Expiration Date 04/24/2023
Miam D Product Control
NEMOletc.
ENOINEER�EVALUgTE I TEST I CONSULT I CERTIFY
353 Christian Street, Unit#13
Oxford, CT 06478
TEL: 203 262 9245
FAX: 203 262 9243
WWW.NEMOETC.COM
Drawn
L Cadena
P.E Review
1�►allura
Plycom USA LLC.
15055 Woodham Drive
Houston, Texas 77073
Steve Phelps
A{iura Plant Engineer
1149 ABTco Road
Wilkesboro NC 28659
Rev
Description
Date
01
2017 FBC
04.24.18
rTitle:
FIBER CEMENT SHAPES
INSTALLATION DETAILS
STEEL STUD CONSTRUCTION
SHAPES- I
Datc
04/24/2018 5 O
NONE
48"
8dx2 Yz" long galvanized common wire nails
fastened in the overlapping area above the top
of the keyway and 16" o.c. horizontally through
the plywood sheathing into the studs. Fastener
vertical spacing not to exceed 8" o.c.
CDX Grade Plywood
Sheathing Mechanically
Fastened To Studs with
#8x1 Y4" Rock —on SIDS
Fasteners (By Others)
Studs © 16"
Plywood Fasteners not shown for clarity
IVIII III I IL/I I I VVI I I�..t ✓IJ IIJI ITV
2x6 Wood Studs with a
Specific Gravity of 0.55 or More
SEE DETAIL A
A
�fi" CDX Grade
Plywood Sheathing
Mechanically Fastened
To Studs
aatherproofing
r 1404.2
F.B.C.
2x6 Wood Studs
ura Fiber
ment Shapes
1
SECTION B-Q
I
Weatherproofing
Per 1404.2 8dx2 7�" long galvanized common wire
Of F.B.C. nails fastened in the overlapping above
the top of the keyway and 16" o.c.
Allura Fiber Cement Shapes horizontally through the plywood sheathing
DETAIL A into the studs
General Notes
1. Wall receiving Fiber Cement Random Square Shapes shall be checked for structural adequacy
(By Others)
2. Walls shall be weather proofed as described in section 1404.2. of the F.B.C.
Product Description
Altura random square material is a non -asbestos Fiber
Cement product tested In accordance with ASTM
C-1185 and meeting the requirements of the
Florida Building Code
Dimensions .
Width Length Thickness
S 16 4' N6"
Design Pressure Rating
Installation on: Design Pressure:
Wood
Impact Studs -95 PSF
Resistant -Planks installed over plywood sheathing
Installation Notes
1. All installation shall be done in conformance with
this Notice of Acceptance, the manufacturers installation
recommendations and the requirements of the
Florida Building Code.
2. Wood studs on to which Allura Fiber Cement Random
Square Shapes will be installed shall be designed by a
Registered Professional Engineer or Licensed Architect
per the F.B.C. and the requirements of this N.O.A.
3. Shapes are to be installed horizontally
commencing from the bottom course of a wall. The vertical
ts must be over framing members. Overall dimension is 9".
4- Shapes are to be installed over %" CDX grade
APA rated plywood supported by 2x6 wood studs with a specific
gravity of 0.55 or more spaced a maximum of 16" o.c.
5. Shapes shall be fastened through the overlapping
planks with 8dx2 X" galvanized common wire nails.
6. The fasteners shall be placed in the overlapping area above the
top of the keyway and 16" o.c. horizontally through the plywood
sheathing into the studs. Screws shall have a minimum edge
distance of �". Vertical spacing not to exceed 8" o.c.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 15-0222.OS
Expiration a 04/2412023
By
Miami -Dads Product Control
N EMOIetc.
ENGINEER�EVALUATE I TEST I CONSULT [CERTIFY
353 Christian Street, Unit#13
Oxford, CT 06478
TEL: 203 262 9245
FAX 203 262 9243
WWW.NEMOEMCOM
Drawn
L Cadena
P.E. Review
Int
Iallura
Plycam USA LLC.
15055 Wood ham Drive
Houston, Texas 77073
Steve Phelps
Altura Plant Engineer
1 149 ABTco Road
Wilkesboro NC 28659
Rev _
Description
Date
01
2017 FBC
04.24.18
Title:
FIBER CEMENT SHAPES
INSTALLATION DETAILS
WOOD STUD CONSTRUCTION
SHAPES-2 r
04/24/2018 6 O1 0
Sale
NONE
48"
120"
B ~—I 'r- -' Studs � 16" o.c.
II II II II II II II
1 I�I I�I I I 1 I I I
0 0 0 0 �,
3/4" Minimum
B Edge Distance
ITW Buildex S-12 #8x1—Y4"x0.315" HD
corrosion resistant ribbed bugle screws
placed 4" o.c. around the perir--�__ _r .L...
soffit and intermediate
Al (u ra
Fiber Cement Soff
General Notes
DETAIL A
Screws C� 4" o.c. (Typ.)
2" Minimum Corner Distance
Product Description
Allura Soffit material is a non—asbestds fiber
Cement product tested In accordance with. ASTM
C-1185 and meeting the requirements of the
Florida Building Code
A SEE DETAI L A
Soffit. Dimensions
Width Length Thickness
B---� < 24" 12' � s"
ITW Buildex S-12 #8x1 Ya"x0.315" HD
corrosion resistant ribbed bugle screws
placed 4" o.c..around the .perimeter of the
soffit and intermediate studs.
..-5i�"x 1—�"x.031 "
20 Gage Steel Studs
1. Studs receiving Fiber Cement Soffit shall be checked for structural adequacy (By Others)
Design Pressure Ratinq
Installation in: Design Pressure:
Steel Studs —70 PSF I
Installation Notes
1. All installation shall be done in conformance with
this Notice of Acceptance, the manufacturer's installation
recommendations and the requirements of the
Florida Building Code..
2. Metal studs on to which Allura Fiber Cement Soffit will• be
Installed shall be designed by. a Registered Professional
� 20 Gage Engineer or Licensed Architect per the F.B.C. and the
Steel Studs requirements of this N.O.A.
Allura Fiber 3- Soffits. are to be installed over 20 gaga x3—�"x1—�"
Cement Soffit steel studs spaced a maximum, of 16' o.c.
4. Allura Fiber Cement Soffit shall be fastened with ITW
Buildex S-12 #8x1 Ya"x0.315" HD corrosion resistant ribbed
bugle screws.
5. Fasteners shall be placed 4" o.c. around the perimeter of thee...
panel and intermediate studs. A(I joints shall be over
studs. screws shall have a minimum edge distance of 3/4" and'
minimum clearance of 2" from the corners.
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 18-0222.08
Expiration D to 04/24/2023
gy � w� -
Miami -Dads Product Control
N EMOletc.
ENGINEER � EVALUATE � Tk3T� CONSULTS CERTI%
353 Christian Street, Unit#I3
Oxford, CT 06476
TEL: 203 262 9245
FAX: 203 262 9243
VWVW.NEMOETC.COM
Drawn by.
L Cadena
P.E. Review
``�yttu>!iltes����
`�0, � 6
4'. Na `'g1 •�
'� TE pF :L
''o' g�P Q.;'Z
.� � ..
O
•���' L O R � C? ,
1�►allura
Plyc�m USA LLC.
15055 Woodham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
I I49 ABTco Road
Wilkesboro NC 28659
Rev
Description
Date
OI
2017 FBC
04.24.18
Title:
FIBER CEMENT SOFFIT
INSTALLATION DETAILS
STEEL STUD CONSTRUCTION
°rawing Sheet:
SOFFIT-1 p
�04/24/2018 7 Of 8
snlc
NONE
48"
� 20"
Studs 16" o.c.
I II I it ll II II II
II I I°I I°I II N II
lal--iL_11- 1
3/4" Minimum
B Edge Distance
Nails © 4" o.c. (Typ.)
6dx2° long galvanized common wire nails
placed 4" o.c. around the perimeter of the
soffit and intermediate st
Allura
Fiber Cement Soffit
General Notes
DETAIL A
2Minimum Corner Distance
"
A SEE DETAIL A
6dx2" long galvanized common wire nails
placed 4" o.c. around the perimeter of the
soffit and intermediate studs.
_.:6 Wood Studs with a
Specific Gravity of 0.55 or More
1 • Studs receiving Fiber. Cement Soffit shalt be checked for structural adequacy (By Others)
i
Wood Studs
Allura Fiber
Cement Soffit
Product Description
Allura Soffit material is a non -asbestos fiber
Cement product tested In accordance with ASTM
C-1.185 and meeting the requirements of the
Florida Building Code
Soffit Dimensions I
Width Length Thickness
< 24" 12Wj 6"
Design Pressure Rating,
Installation on: Design Pressure:
Wood Studs —70 PSF
Installation Notes
1. All installation shall be done in conformance with
this Notice of Acceptance, the manufacturer's installation
recommendations and the requirements of the
Florida Building Code,
2. Wood studs on to which Allura Fiber Cement Soffit will be
installed shall be designed by a Registered Professional
Engineer or Licensed Architect per the F.B.C. and the
requirements of this N.O.A.
3. Soffits are to be installed .over 2x6 wood studs with a specific
gravity of 0.55 or more spaced a maximum of 16" o.c.
4. Allura Fiber Cement Soffit shall be fastened with 6dx2"
long galvanized common wire nails.
5: Fasteners shall be placed 4" o.c. around the perimeter of the
panel and intermediate studs. All joints shall be over
studs. screws shall have a minimum edge, distance of 3/4 and
mum clearance of 2" from the corners..
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 18-0222.08
Expiration D 04/24/2023
By
Miami-D4dProduct Control
_ NEMOIetc.
ENGINEER EVALUATE j TEST I CONSULT I CERTIFY
353 Christian Street, Unit#l3
Oxford, CT 06478
TEL: 203 262 9245
FAX: 203 262 9243
WWW.NEMOETC.COM
Drawn by:
L Cadena
A.E. Review
jjN
`��O��P•G E N S , as
�����•
l
�; No 591 6 oo
cc
w
-O ST TE DF Z :
et
Iallura
%ycem USA LLC.
15055 Woodham Drive
Houston, Texas 77073
Steve Phelps
Allura Plant Engineer
C149 ABTco Road
Wilkesboro NC 28659
Rev # Description Date
01 2017 FBC 04.24.18
e:
DETAILS
FIBER CEMENT SOFFIT
INSTALLATION
WOOD STUD CONSTRUCTION
Drawing. Sheet:
SOFFIT-2
°ato4/24/201 s 8 Of 8