Loading...
HomeMy WebLinkAboutAPPROVED underlayment product approval5/26/2021 Florida Building Code Online Y. ,:gip rA�„ts►oflydi1�a.r BCIs Home Log In user Registration Hot Topics Submit Surcharge stats & rails Publications Contact Us MIS Site Map Lnks search b(412roduct Approval USER: Public User Product Approval Menu > Product or Application Search > Apph4atjon List > Applltation Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL32344-Rl Revision 2020 Approved Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43645 (740)321-6345 Greg. Keeler@owenscorning.com Keeler Greg Greg, Kee ler@owenscorning,com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 05/05/2021 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL32344 R1 CO] 2020 01_COI NIEM_INEN.p2f Standard ASTM D1970 Year 2015 Product Approval Method Method 1 Option D https:llwww.noridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDquO6fur%2fZNOOlyVpO6mrKFjUpV6vnB6jKEzzSO8%2fRaQFw%3d%3d 112 5/26/2021 Florida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL 7f 32344.1 Model, Number or Name RhmoRoof GRN Limits of Use Approved for use in HVH2: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. 12/11/2020 12/15/2020 12/17/2020 02/09/2021 Description Granule -surfaced, self -adhering roof underlayment Installation Instructions FL32344 BI II 2020 17 10 FINAL ER RHINOROOF GRN FL32344-R1 p_df Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL32344 RI AE 2020 12 10 FINAL ER RHINOROOF GRN FL32344-R1 pd Created by Independent Third Party: Yes Contact Us :: 2601 ala' S[ Load.Tall h FL 32399 Phone 850-98]-1829 The State of Florlda is an AA/EEO employer. Capyjgh[ 200]-2013 State of FI Id :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395, "Pursuant to Section 455.275(t), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emous provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here -. Product Approval Accepts: https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu06fur%2fZNOOlyVpO6mrKFjUpV6vnB6jKEzzSO8%2fRaQFw%3d%3d 2/2 0 ENGINEER EVALUATE Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740)321-6345 NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT06478 (203) 262-9245 TEST CONSULT Evaluation Report 3m-OC-20-FBCER.01-RI FL32344-RI Date of Issuance:06/04/2020 Revision 1: 12/10/2020 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RhinOROOfO GRIN LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3 Prepared by:,,,,i Robert J.M. Nieminen, P.E. q.= The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983,?*,-, E .; .._: '•,„d�.�, q:: Nieminen, P.E. on 12/10/2020. This does not serve as �+`� an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturingor distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used forpermitting or design guidance unless retained specifically for that purpose. ®2019 NEMO ETC, LLC NNEMO etc. ROOFING COMPONENT EVALUATION: a• Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoofO GRIN, as produced by Owens Corning Roofing and Asphalt, LLC, has demonstrated compliance with the following sections of the 7tn Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015 / R905.1.1, R905.2.8.2 3. REFERENCES: Ent(ty Examination Reference Date PRI(TST5878) ASTM D1970 OCF-293-02-03 12/20/2017 PRI(TST5878) ASTM D1970 OCF-253-02-02 12/21/2017 Owens Corning Quality Control Declaration 07/15/2020 PRI (QUA9110) Quality Control Service Confirmation 05/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current Product Material Standard Plant(s) Description RhinoRoof® GRN ASTM D1970 (Table 1)1 Brentwood, NN Granule -surfaced, self - Houston, TX adhering, roof underlayment 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction, 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 RhinoRoof GRN may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. t Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of A5TM D1970-15, should be established as to slip resistance of RhinoRoof GRN. NEMO ETC, LLC Evaluation Report 3m-OC-20-FBCER.01-R1 Certificate ofAuthorizotion #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL32344-RI Owens Corning RhinoRoof* GRN Revision 1: 12/10/2020 Page 2 of 3 5.6 5.7 5.8 5.9 NNEMO etc. Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FOCSection: 1507.2 1507.3 1507.4 & 15075 15077 1507.8 & 3507.9 Clay and Concrete TILE Metal wood Underlayment Asphalt Shingles Slate or Slate. Mechanical Adhesive- Attach Attach Set Panels Shingles Type Shingles Shingles Shakes Yes RhinoRoofe GRN Yes No No No No Yes (loirtwips, 1507A.13/ R905.1.1.3) Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) RhinoRoof®GRN self -adhering Deck/sheathing None Plywood Attachment Limitations: For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) RhinoRoof® GRN Mechanically attached 30 6. INSTALLATION: 6.1 RhinoRoof GRN shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 1 RhinoRoofe GRN: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. BUILDING As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named GA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. PRI Construction Materials LLC— QUA9110; (813) 621-5777; bwilson@pricmt.com END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 3m-OC-20-FBCER.01-RI Certificate afAuthorizotion N32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL32344-R1 Owens Corning RhinoRoof- GRN Revision 1: 12/10/2020 Page 3 of 3