Loading...
HomeMy WebLinkAboutAPPROVED Rhino U20 underlayment product Approval5/26/2021 Florida Building Code Online $ r.'t.• '�1�` ,�; r� � a to ���. BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications ci blpr �a Product Approval USER: Public User Product APpr va—A� > product or Application Search > 8pp6c_.,�{ion List > Application Detail FL # FL15216-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Contact Us BCIS Site Map Links Search Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740)321-6345 Greg, Keel er@owenscorning, cam Authorized Signature Keeler Greg Greg. Keefer@owenscorning, com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740)321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc, - QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By John W, Knezevich, PE Certfficate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Validation Checklist - Hardcopy Received FL15216 RS COI 2 20 01 COI NIEMINEN pdF Standard Year ASTM D226 (physicals) 2009 ASTM D4533 (tear strength) 2015 ASTM D4798(weathering) 2011 ASTM D4869 (liquid transmission) 2016 ASTM D5035 (tensile strength) 2011 https:Ilwww,floridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl QRAdhyl2u8kQGLi8btgGXrz3lAl6NKjRPbg%3d%3d 112 5/26/2021 Sections from the Code Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 12/16/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Summary of Products FL # Model, Number or Name Description 15216.1 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See ER Section 5 for Limits of Use. Synthetic roof underlayments Installation Instructions F 1 16 R8 II 101 1 1 FINAL ER OWENS CORNING RHINOROOF F ts21r; BL _df Verified By: Robert Mennen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL15216 R8 AE 2020 12 15 FINAL Eg OWENS CORNING RHINOROOF FL1521 R8 pdf Created by Independent Third Party: Yes ContactUs : 2601 Bla r Stone R„�n Tallahass a FL 99 Phone, 850-487-1824 The State of Florida Is an A VEEO employer. Sqp qhl 2007-2013 S[at f FI tl Pr vacv Statement :: Access b ITy Statement :: Refunds t Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the once by phone or by traditional mall. If you have any questions, please contact 850.487 ' 1395. 'Pursuant to Section 455.275(t), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The amends provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please click here. Product Approval Accepts: rT W] FIX heq https://www.floridabuilding.orglprlpr_app_dtl.asp,?param=wGEVXQwtDgv3yVVKJZlQRAdhyl2u8kQGLi8btgGXrz3lAl6NKiRPbg%3d%3d 2/2 CNUI NUK EVALUATE Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 linai 191-GIAC TEST CONSULT Evaluation Report 140510.02.12-119 FL15216-R8 Date of issuance:02/17/2012 Revision 9:12/15/2020 SCOPE: This Evaluation Report is issued under Rule 61G20.3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. '•My{i :,,`�_; The facsimile seal appearing was authorized by Robert Florida Registration No, 59166, Florida OCA ANE1983 y;,,i;,..• Nieminen, P.E. on 12/15/2020. This does not serve as an CERTIFICATION OF INDEPENDENCE: electronically signed document. 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC NINEM0 etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1507.1.1.1(2&3, Exception), Tear strength ASTM D4533 2015 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1518.4, RAS 115 Unrolling, Breaking Strength, Pliability ASTM D226 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Enti Examination Reference Date ITS(TST1509) ASTM D226 100539395COQ-006 10/26/2011 ITS(TST1509) ASTM D4869 100539395COQ-002 10/26/2011 PRI (TST5878) ASTM D226 / D4798 / D4869 OCF-394-02-07.4 01/06/2020 PRI (TST5878) ASTM D226 / D4798 OCF-464-02-02.2 01/06/2020 PRI (TST5878) ASTM D4533/ D5035/ D4798 1378TO109 10/15/2020 PRI(TST5878) ASTM D4533/D5035 1378TO127 10/15/2020 ITS (QUA1673) Quality Control Service Confirmation 12/09/2020 ITS (QUA1673) Quality Control Florida BCIS Current 4.1 4.2 43 PRODUCT Product Specification Plant(s) Description RhinoRoof U20 1507.1.1.1(2&3, Exception), Qingdao, China Multilayered polymer woven 1507.1.1.1(5) / R905,1.1.1(2&3, coated synthetic roof Exception), R905.1.1.1(5) underlayment ABC Pro Guard 20 1507.1.1.1(2&3, Exception), Silvassa, India Multilayered polymer woven 1507.1.1.1(5) / R905.1.1.1(2&3, coated synthetic roof Exception), R905.1.1.1(5) underlayment SRS TopShield TS20 1507.1.1.1(2&3, Exception), Silvassa, India Multilayered polymer woven 1507.1.1.1(5) / R905.1.1.1(2&3, coated synthetic roof Exception), R905.1.1.1(5) underlayment NEMO ETC, LLC Evaluation Report 140530.02.12-119 Certifcote of Authorizotion#32455 7'H EDITION (2020) FBC NON-IIVHZ AND HVHZ EVALUATION FL15216-R8 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 2 of 4 ONEMOIetc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 Rhinc Roof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers: TABLE 1: ROOF COVER OPTIONS FBC NON-HVHZ: 1507.2 1507.3 1507.4 & 1507.5 15077 IS07.8 & 1507.9 FBC HVHZ: TAS 1101510), RAS IIS TA5130(S13), RAS 133 iA5110(S11) RAS 130 RAS 118 119 & 120 Underlayment Asphalt Shingles Clay and Concrete Metal Slate or Slate -Type wood Tile Shingles Rhino Roof U20 Yes No Yes No NON-HVHZ: No HVHZ: Yes ABC Pro Guard 20 Yes No Yes No NON-HVHZ: No HVHZ: Yes SRS TopShield TS20 Yes No Yes No NON-HVHZ: No HVHZ: Yes 5.6 Exposure Limitations: TABLE 2: EXPOSURE LIMITATIONS Underlayment Maximum Exposure (days) RhinoRoof U20 60 ABC Pro Guard 20 30 SRS TopShield TS20 30 NEMO ETC, LLC Evaluation Report 140510.02.12-119 Certificate o)Autharizotion N32455 7- EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-118 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 3 of 4 NNEMO I etc. 6.1 RhinORoof U20, ABC Pro Guard 20 and SRSTopShleld TS20 Roof Underlayments shall be installed in accordance with the manufacturer's published installation instructions subject to the Limitations set forth in Section S herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments: 6.3.1 1 NON-HVHZ Jurisdictions: 6.3.1.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.1.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.3.2 HVHZ Jurisdictions: 6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side (horizontal) laps and minimum 6-inch wide end laps, and fastened in accordance with FBC HVHZ 1518.2. BUILDING7. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. Intertek Testing Services NA Inc.—QUA1673; (312) 906-7779; maura.norlander@mtertek com END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 140510.02.12•R9 Certificate of Authorization#32455 7T" EDITION (2020) FeC NON-HVHZ AND HVHZ EVALUATION FL15216-R8 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 4 of 4