HomeMy WebLinkAboutProject Information y
..,' Jj
RECEIVED
JUN 01 1011
Section A(Genera!Information) Permitting Department
St. Lucie County
Master Permit No. Process No.
Contractors Name: ) recxSv reeC n� c, 653
Job Address d � !� ICo ou �C'
ROOF CATEGORY
0 LowSlope ❑Mechanically Fastened Tile 13Mortar/Adhesive Set Tiles `
0Asphaltic Shingles IqMetal Panel/Shingles DWood Shingles/Shakes
13 Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
0 New roof 13.Repair 13 Maintenance Reroofing ❑Recovering
.ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF)_Jl�V
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
I F
spm �.•
12 24(240) 17
c
DAS 28
(1`1D4)
i
33 20
GPA 21
(42D)
t
I
L U
Section C(Low Slope-Roof) Surfacing:
Fill in specific root assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
.manufacturer Zone 1':—"oc @ Lap,Lt Rows—@ 00
(if a component is not used,identify as'WA") Zone 1: oc 6 Lap,#Rows—@
0C
System Manufacturer: Zone 2:-'1,oc'@ Lap,:#Rows.—@ Woo
Product Approval No.: Zone 3:--" oc @'Lap,#Rows--��@00'
Number of Fasteners Per Insulation'Board,
Design Wind Pressures.,From RAS.128 Or Calculations: Zone 1': Zone 1: Zone 2:—Zone 3:
Zone V: - Zone 1: Zone 2:—Zone 3' Illustrate-Components Noted and Details as Applicable:
Max. Design Pressure.,from the.specific product approval Woodblockihg,, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous, Cleat, Cant Strip, Base Flashing',
CoOnterflashing,Coping,Etc'.,
Deck: Indicate; Mean-Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness,Fastener
'Gauge Thickness: Type,Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s)t
.Anchor/Base Sheet Fastener/Bonding Material: ------FT.-----_2
Insulation Base,Layer:
Base Insultation Size and Thickness-, Parapet
Base Insulation Fastener/Bonding.Material; Height
Top insulation Layer:
Too Insulation Size and Thickness: FT.-
Top insulation Fastener/Bonding Material:
Mean
Base Sheet(s)St No.of Plj(s): Roof
Base Sheet Fastener/Bon ding Material: Height
.Ply Sheet(4)'&No.'of Ply(s)-*
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top.PIV Fastener/Bonding Material:
L U FI E?"as
Section D:(Steep Slope Roof.Syst�e\m)
Roof system Manufacturer: VQlid CIC-3Y• yuAa in
.Notice of Acceptance Number:
L aay�y- �
Minimum Design Wind Pressures;If Applicable(From RAS 127 or Calculations):
Zone 1:: Zone 2e:-Zone 2n:-Zone 2r:Z&Uone 3e: Zone 3r:"f y
Deck Type: y 4J
Type Underiayment ]�,eel Qn G
Roof Slope:
—� 12 insulation:
• �re Barrier• ..
F
idge Veritilatlan? Fastener Type&Spacing:
Adhesive Type:
�v Q,�i 6" SGre t
'Type Cap Sheet �!
Mean Roof Height: ;L I ' Roof Coveiing, "Cin��its 4 rti5 C..� `40
Type&Size Drip
Edge: