Loading...
HomeMy WebLinkAboutProject Information y ..,' Jj RECEIVED JUN 01 1011 Section A(Genera!Information) Permitting Department St. Lucie County Master Permit No. Process No. Contractors Name: ) recxSv reeC n� c, 653 Job Address d � !� ICo ou �C' ROOF CATEGORY 0 LowSlope ❑Mechanically Fastened Tile 13Mortar/Adhesive Set Tiles ` 0Asphaltic Shingles IqMetal Panel/Shingles DWood Shingles/Shakes 13 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. 0 New roof 13.Repair 13 Maintenance Reroofing ❑Recovering .ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF)_Jl�V Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. I F spm �.• 12 24(240) 17 c DAS 28 (1`1D4) i 33 20 GPA 21 (42D) t I L U Section C(Low Slope-Roof) Surfacing: Fill in specific root assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: .manufacturer Zone 1':—"oc @ Lap,Lt Rows—@ 00 (if a component is not used,identify as'WA") Zone 1: oc 6 Lap,#Rows—@ 0C System Manufacturer: Zone 2:-'1,oc'@ Lap,:#Rows.—@ Woo Product Approval No.: Zone 3:--" oc @'Lap,#Rows--��@00' Number of Fasteners Per Insulation'Board, Design Wind Pressures.,From RAS.128 Or Calculations: Zone 1': Zone 1: Zone 2:—Zone 3: Zone V: - Zone 1: Zone 2:—Zone 3' Illustrate-Components Noted and Details as Applicable: Max. Design Pressure.,from the.specific product approval Woodblockihg,, Gutter, Edge Termination, Stripping, system: Flashing, Continuous, Cleat, Cant Strip, Base Flashing', CoOnterflashing,Coping,Etc'., Deck: Indicate; Mean-Roof Height, Parapet Height, Height of Base Type: Flashing,Component Material,Material'Thickness,Fastener 'Gauge Thickness: Type,Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s)t .Anchor/Base Sheet Fastener/Bonding Material: ------FT.-----_2 Insulation Base,Layer: Base Insultation Size and Thickness-, Parapet Base Insulation Fastener/Bonding.Material; Height Top insulation Layer: Too Insulation Size and Thickness: FT.- Top insulation Fastener/Bonding Material: Mean Base Sheet(s)St No.of Plj(s): Roof Base Sheet Fastener/Bon ding Material: Height .Ply Sheet(4)'&No.'of Ply(s)-* Ply Sheet Fastener/Bonding Material: Top Ply: Top.PIV Fastener/Bonding Material: L U FI E?"as Section D:(Steep Slope Roof.Syst�e\m) Roof system Manufacturer: VQlid CIC-3Y• yuAa in .Notice of Acceptance Number: L aay�y- � Minimum Design Wind Pressures;If Applicable(From RAS 127 or Calculations): Zone 1:: Zone 2e:-Zone 2n:-Zone 2r:Z&Uone 3e: Zone 3r:"f y Deck Type: y 4J Type Underiayment ]�,eel Qn G Roof Slope: —� 12 insulation: • �re Barrier• .. F idge Veritilatlan? Fastener Type&Spacing: Adhesive Type: �v Q,�i 6" SGre t 'Type Cap Sheet �! Mean Roof Height: ;L I ' Roof Coveiing, "Cin��its 4 rti5 C..� `40 Type&Size Drip Edge: