Loading...
HomeMy WebLinkAboutProduct Approval BCIS Home i Log In User Registration `Hot Topics } Submit Surcharge j. Stats @ Facts { Publications j Contact Us']' BCIS:Site Map i Links Search. Flod,a Product Approval USER:Public user RECEIVED . � Prcxhict Approval Wnu>Product or Application Search'>Armiicanon U >Application Detail JUN 0 2021 S r R20484-R2 >rt Permitting Department Application Type Revision St, Lucie County, Code Version 2020 Application Status Approved :Comments D Archlved /7 Product Manufacturer UNION CORRUGATING COMPANY OAD C ® p® Address/Phone/Email 701 S.KING ST. ., FAYETTEVILLE,NC 28301 �IJC® ®� (910)813-2432 Ae c �� rblake@unioncorrugating.cor I N Authorized Signature Randy Blake VC C rblake @uh ioncorrugating,com Technical Representative Address/Phone/Email �ls Quality Assurance Representative L®�� Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from'a Florida Registered.Architect.or a Licensed Florida Professional Engineer f , Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Baia Sockalingam the Evaluation Report Florida license PE-62240 Quality Assurance Entity Keystone'Certirications,Inc. Quality Assurance Contract Expiration Date 09/07/2027 Validated By Yoosef Lavi,P.E. W Validation Checklist-Hardcopy Received '. Certificate of Independence FL20484''R2 COI Certificatelndeoendetice:rid f Referenced Standard and Year(of-Standard) Standard Year FM 4470 2016 TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https:/Iwww.floridabuilding.org/pr/pr app_dtl.aspx?param=%vGEVXQwtDgsJ9a49YAgXJ... 1/12/2021 Florida Building Code Online '' Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 16/10/2020 Date Validated 10/12/2620 Date Pending FBC Approval 10/22/2020 Date Approved 12/16/2020 - t Summary of Products FL#, Model,Number or.Name. Description 20484.1 5V' Min 26 ga.,24"wide throughfastened panel over'15/32" thick'plywood Limits of Use Installation Instructions Approved for use in HVHZ:-No FL20484 R2'I1 Eva luationReportC2401 .I.pdf Approved for-use outside HVHZ:Yes Verified Byi Bala Sockalingam,`P.E.62240 Impact Resistant:-N/A Created by Independent Third Party:-Yes _ Design Pressure:+N/A/-1"69 Evaluation Reports Other:Uplift load of 71.0'psf @:fastener spacing of 24":6c. FL20484 R2`AE EvaluationRen6rtC2401 1.pdf &169.0_psf @ fastener'spacing of 6"o.c. Created by Independent Third Party:Yes 20484.2 Advantage=Lok II Min 26 ga:;16"wide concealed.fa6tened.panel.over.7/16" thick OSB&45/32"&thick plywood. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R2 II`Eva luationReportC240I 2.odf Approved for'use outside-HVHZ:'Yes. Verified By:Bala Sockalingam P.E.62240 Impact Resistant:N/A Created by IndependentThird•Party:Yes Design Pressure:.+N/A/-131.5 Evaluation Reports Other:Maximum uplift load of 131.5 psf.@ seam fastener FL20484 R2 AE Evaluat!6nReoortC2.401 2.rdf spacing-of 4-518"o.c.along seam into min.15132"thick APA . .Created by Independent Third Party:Yes rated plywood with retainer strap. 20484.3 Aluminum Advantage-Lok.II Max 16.375"wide;nom 0.032"thick,(min:)-alumIhum concealed Fastener roof panel over min 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation.Instructions Approved for use'in HVHZ:No: FL20484 R2 11-EvaluationReoortC2401 3.ndf. Approved for use outside HVHZ:Yes Verified By:Baia Sockalingam P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-93.5 Evaluation Reports Other:Uplift load of 22.5 psf at fastener spacing of 18.5" FL20484 R2 AE EvaluationReaorEC240t 3.ndf o.c.and 86.0 psf at fastener spacing of 4.63"o.c.in 15/32'. Created'by Independent Third Party:Yes- plywood or 7/16".OSB,,Uplift load of 93.5 psf at fastener spacing of'4.63".o:c.with adhesive in 15/32"plywood. 20484.4 Aluminum SL150 Max 16"wide;nom 0.032"thick(min.)aluminum snap-lock standing seam metal panel over min 15/32"thick plywood deck or 7/16"thick OSB Limits of Use Installation'Instructions Approved for use in HVHZ:No FL20484.R2 II Eva lua_tiongeaortC240I 4,odf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240 Impact Resistant:,N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-86 Evaluation Reports Other:Uplift load of 45.0 psf at clip spacing of 24"o.c.and FL26484 112"AE EvaluationReportC2401 4.bdf 78.5 psf at clip spacing of 6"o.c.in 15/32"plywood or 7/16" Created,by Independent_Third'Party:-Yes OSB.Uplift load of.86.0 psf at clip spacing of 6"o.c.with adhesive in 15/32"plywood. 20484.5 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32" thick plywopd'or 7/16"thick OSB Limits of Use Installation instructions Approved for use in HVHZ:No FL20484 R2 1I.EvaluationReoorQ401 5.odf Approved for use outside HVHZ:Yes Verified By:.Bala Sockalingam;P:E.•62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-124 Evaluation Reports. Other:Uplift load of 56.0 psf @ fastener spacing of 24"o:c. FL20484 R2'AE Eva hiationReportC2401 S.pdf, lk 124.0 psf @fastener spacing of 6''o.c. Created by Independent Third Party:Yes, 20484.6` MasterRib Min 29 g6.,.36"wide through fastened pariel.over 15/32" thick plywood Limits of Use Installation Instructions Approved for'use in HVHZ:No FO-0484 R2-II EvaluationReo6rtQ22401 6.1idf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact"Resistant:N/A Created.by Independent Third Party:Yes Design Pressure:+N/A/788.5 Evaluation Reports Other:Uplift load of 56 psf for Fastening System 1.Uplift FL20484`R2 AE EvaluationR6ortC2401 6.odf load of 88.5 psf for,Fastening System 2. Created by.Independent Third Party:Yes https://www.floridabuilding.org/pr/pr=app_dtl:aspx?param=wGEVXQwtDcisJOa49YAgxj... 1/12/2021 Florida Building Code-Online i Page 3 of 3 . J 20484.7 ML150 Max 16.5"wide,min 24 ga.steel standing'seam panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R'2 11 EvaluationReportC2401 7.odf Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design.Pressure:+N/A/-124 Evaluation Reports Other:.Maximum uplift load of 124 psf @ clip spacing of 6" FL20484 R2 AE Evalu6ti6nRenoi2C2401 7:odf D.C.with 180 seam,self-adhering membrane and fixed clip. Created by Independent Third Party:Yes 20484.8 PBR or R Panel Min 26 ga.,36"wide through fastened panel over 15/32" thick.plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R2 II Eva luationRerwtC2401 8.odf ' Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P:E.62240 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-161.5' Evaluation Reports Other:Uplift load of 30.0 psf.at fastener spacing of 48"o.c. FL20484 R2 AE Eva IuationRenoaC2401 8:6df and 161.5 psf at fastener spacing of 6"o.c. Created by Independent.Third Party:Yes' 20484.9 SL175 Max 18"wide,min 24 ga.,snap-lock standing seam metal panel over 15/32"thick plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL20484 R2 II Eva luationRepprtC2401 9.edf Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam;P.E.62240 Impact Resistant:N/A Created by'Independent-Third Party:Yes Design Pressure:+N/A/-93.5 Evaluation Reports Other:Uplift load of39.8 psf @ clip spacing of 36"D.C.and FL20484 R2 AE EvaluationR.eDortC2401 9(12df 78.6 psf @ clip spacing of 8"o.c with felt.Uplift load of 93.5 Created by Independent Third Party:Yes psf @ clip spacing of 12"o.c.with self-adhering membrane. Back next Contatt Us::2601 Blair Stone Road.Tallahassee FL32399 Phone:850-487-1824 The State of Florida is an AA/EEO empioyer.Coovdntit 2007-2013 State of Flodda.::Privacy.Statement::Accessibility Statement::Refund Statement .Under Florida law,email addresses are public records.If you.do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.-Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275 (1),Mrida Statutes,effective October 1,2012,'licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have.one.The emails provided may be used for official communication tvlth the licensee.However email addresses are,public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts:. ! Credit Card Safe hops://www.floridabuilding.org/pr/pr app_dtl.aspx?paratn=wGEVXQwtDq J9a49YA9XJ:.. 11/12/2021. 'EVALUATION REPORT OF UNION'CORRUGATING COMPANY `26 GA.ADVANTAGE-LOK II' FLORIDA BUILDING CODE 7Tx EDITXON(2020) FLORIDA PRODUCT APPROVAL FL 20484.2-R2 ROOFING METAL ROOFING Prepared For: Union Corrugating Company 701 S. Ding St. 'Fayetteville,NC 28501 Telephone: (910).483-0479 Fax: (910)483-1091 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida.Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa, OIL 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) ,g:`'coo GKAL'/,�,G,�: �a 62249 •�� Report No. C2401-2 ro`• C OF Date: 16.10.2020 STAB ���, . 0 1 • • lG. tC'�. 202...0 FL 20484.2-R2 C2401-2 10.10.2020 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: Advantage-Lok II Panel Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Minimum 26 ga., 50 ksi'steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 7/16" thick OSB or min. 15/32" thick APA rated plywood or min. W thick wood plank" '(min SG of 0.42) for new and existing constructions.:Designed by others and installed as per FBC 2020. New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1. Required for new construction. Existing Underlayment: One layer of asphalt shingles over one layer of 430 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 2:12. Design Uplift Pressure: 30.0 psf at panel fastener spacing of 13-7/8" o.c. along seam (Factor of Safety=2) 63.5 psf at panel fastener spacing of 9-1/4" o.c. along seam 78.5 psf at panel fastener spacing of 4-5/8" o.c, along seam 112.5 psf at seam fastener spacing of 4-5/8" o.c. along seam with 3/16" diameter bead adhesive in panel seam 131.5 psf at seam.fastener spacing of 4-5/8" o.c. along seam into min. '15/32" thick APA rated plywood with retainer strap Panel Attachment: #10-12 pancake head wood-screws along panel seam. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". .Retainer Strap: 5" wide, 24_ga., 50 ksi strap fastened to deck with 2 rows of#10-12 x 1" long pancake head screws at 12" o:c.spacing and 6" staggered. The strap is continuous over the entire corner or edge roof zones. Prior to the panel installation, two rows of 3/8" bead of adhesive are field applied along the length of the strap and a row of 3/8 bead of adhesive.on the male leg of panel. Seam Adhesive: 8ikaflex-201 or APS 500 Advance Polymer Sealant. In lieu of Sikaflex or APS sealant, adhesive with greater or equal tensile properties may be used. FL 20484.2-R2 C2401-2 l 0.10.2020 Page 3 of 3 Test Standards: Roof assembly tested in accordance with UL580=06 `Uplift Resistance of Roof Assemblies' & UL189.7-04 `Uplift Tests for Roof Covering Systems' .or TAS 125-03 `Standard Requirements for Metal Roofing Systems' Test.Equivalency: The test procedures in UL 1897-04 comply with test .procedures prescribed in UL 1807-12. 'Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in.-accordance with FBC,.2020 .Section 1609 or. ASCE 7-16 using allowable stress design. The maximum fastener spacing listed herein -shall not be exceeded. This :evaluation,report is riot applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is riot within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials-directory .or ASTM E108/UL790 report from an'accredited laboratory for fire'ratings of this product. Supporting Documents: UL580&UL1897 Test Reports 'PRI Construction Materials Technologies UCC-006-02-1 Rev 1,Reporting Date 2/10/12 TAS 125 Test Report Farabaugh Engineering and Testing Inc. Project No.T30246,Reporting Date 1-1/16/16,Revised Date 1/18/17 Project No. T303-16,Reporting Date'l 1/16/16,Revised Date 1/18/17 Project No.T304-16,Reporting Date 11/16/16,Revised Date 1/18/17 i 1 NEW UNDERIAYMENT SEE DETAILS 1 & 2 PANEL OVERLAP PANEL FASTENER - ROOF PANEL owu ®'MAX:13-7/B'O.C. �rsvns "a EAI7— STING UNDER IAYMENT II OSB 7/i6'.THICK(MIN.)OR I 'g (OPTIONAL) (OPTIONAL) SHINGLES DECK ATTACHMENT.AND PLYWOOD 15 IC THICK(MIN.) yg@ (OPTIONAL) SUPPORTS MUST BE :/ d RAFTEa/JOISi/TRU55 DESIGNED AND INSTALLED t� BY OTHERS 6 'TYPICAL PANEL. INSTALLATION X-SECTION NEW UNDERLAYMENT 3/8'BEAD OF •(2)3/8'BEAD OF I@10-12%1'SCREYIS PANEL FASTENER ROOF PANEL "ADHESVEADHESNE2 ROWS STAGGERED .®'MAX:4-5/8'.D.C. ®6'O.C.rxi— ADHESuE z 'i Z RETAINER� STRAP -;_PLYWOOD 15/32'THICK(MIN.) U DECK ATTACHMENT AND S'IMDE,24 CA SUPPORTS MUST BE . DES;CNED AND INSTALLED 'RAFTER/JOIST/RtUSS z C BY OTHERS AT 1.lAlc.24'O.C. o PANEL INSTALLATION WITH RETAINER STRIP 2 4 MIN 26 CA. PANEL 110=12 PANCAKE HEAD -_ a WOOD FASTENER ALLOWABLE UPLIFT PRESSURE m. c „;R NEW UNDERIAYMENT - - o E%ISTOTC SHINGLES 14-5/0- . MINIA!UM SEAM` RETAINER PRESSURE a as` (OPDOY41)" .SUBSTRATE ADHESIVE STRAP --'-'- ---' DwETER (��7/16'OSS . .NONE- NONE, 30.0o7/i6'OSBNONE NONE 63.5E%ISTING IIDERAYUENT 7/16-OSB NONE - 'NONE 78.5 p 2(OPDaNAL) DETAIL 1 :OSS 7/16-THICK(MIN.)OR PLYWOOD 15/32'THICK(MIN.) 7/16-OSB 3/16' .NONE .1125 15/32'-PLY 1 3/6', REQUIRED. 131.5 IKAFLEI(2a1 MIN 26 GA. PANEL OR EQUNALENT GENERAL N OTESI 3/16"BEAD #,10-12PANCAKE HEAD' 1.ARCHITECTURAL ROOF.PAHEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE WOOD FASTENER FLOW BUILDING CODE(FBC). ` NEW UNDERLAYL!EUT 2. ROOF PANELS ARE'SHALL BE.26 GA.EFFECTTrEICOVERING WIDTH OF —_ E%ISRRG SHINGLES OF PANEL- 16'. (OPT—) 3. HE ROOF PANELS SHALL BE INSTALLED OVER SHEATKNG&STRUCTURE AS _—_—__ —_—_ SPECIFIED ON THIS DRAWING. ' 4. REQUIRED'DESIGN WIND LOADS SHALL BE DETERMINED FOR'EACH PROJECT. THIS.PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN -WIND LOADS ARE,GREATER THAN THE,ALLOWABLE WIND LOAD TABLE. - 5.ALL FASTENERSm MUST BE IN ACCORDANCE WITH THIS DRAWING&THE FLORIDA E%ISONG UNDERIAYMENT J BUILDING CODE. IF A DGFERENCE,000URS''BETWEEN THE MINIMUM _(OPTIONAL) DETAIL 2 OSB 7/I6-THICK(MIN.)OR REQUIREMENTS DF THIS DRAMANC&THE CODE,THE CODE SHALL CONTROL Z4O1-Y PLYWOOD 15/32.THICK(MIN.) .6.RAFTERS/JOISTS/TRUSSES MUST,BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND:ARE,THE RESPONSIBILITY OF OTHERS. swTa 1p 1 � T