HomeMy WebLinkAboutCompaction testA Universal
Engineering
Sciences
Company
UES Project No: 3310.2100034.0000
Workorder No: 234811-1
Report Date: 05/28/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: K. HOVNANIAN HOMES UES Technician: Mark Rogers
3601 Quantum Blvd. Date Tested: 05/28/2021
Boynton Beach, FL 33426
Project: CMT/CSD Aspire at Waterstone
5226 Arming Place, Ft. Pierce, St. Lucie County, FL 34951
Area Tested: Lot 25 - 5126 Arming Place, Ft Pierce
Material: Backfill
Reference Datum: 0 =Top of Fill
The tests below meet the 95% minimum compaction requirement.
sir of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory, ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
N
(pcf)
N
N
Fail
1
Northeast corner of lot
0-1 ft
120.1
10.9
116.7
10A
97
Pass
2
Southwest corner of lot
0-1 ft
120.1
10.9
117.7
10.6
98
Pass
3
Center of lot
0-1 ft
120.1
10.9
117.8
10.6
98
Pass
Remarks: Above stripped surface 1-2', 2-3' HCP=60+5 > 95 %Compaction, PASS. HCP tests are empirically correlated to the
relative density of the soil.
Permit: 2104-0686
Reviewed By
GFA International, Inc
FBPE Registry No.4930
V%
. SQOMINC,N� /i
'; moo•,. ., � ;
` * - No. 64146
SPATE O``
�i �� �•• FIORVOP.•�G�:
SS/ONA1. E . `.
rrrlriirit,,
Digitally signed by
Thomas D
Montano:A01410000000
17818498DCD000019A3
Date: 2021.05.28
13:56:27-04'00'
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1