Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED M 210427 ENERGY FORM
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: CARUSO RESIDENCE BuilderName: Street: 4805 WATERSONG WAY Permit Office: City,State,Zip: FT.PIERCE ,FL, PermitNumber: Owner: JEAN CARUSO Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(4049.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=5.0 3629.00 ft2 b.Frame-Wood,Adjacent R=11.0 420.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (1167.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 1167.00 ft2 6. Conditioned floorarea above grade(ft2) 2761 b.N/A R= ft2 Conditioned floorarea belowgrade(ft2) 0 c. N/A R= ft2 7. Windows(522.6 sqft.) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:A/C 1 6 275 a. U Factor: Sgl,U=0.65 522.64 ft2 b.Sup: Attic,Ret:Attic,AH:HALLWAY 6 95 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 36.0 SEER:17.00 c. U-Factor: N/A ft2 b.Central Unit 25.0 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 4.408 ft. 14. .ElecricStipHems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a.Electric Strip Heat 27.0 COP:1.00 b.Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (2761.0 sqft.) Insulation Area EF:0.950 a.Floor Over Other Space R=0.0 1747.00ft2 b.Conservation features b.Slab-On-Grade Edge Insulation R=0.0 553.00 ft2 None c.other(see details) R= 461.00 ft2 16.Credits None Glass/Floor Area: 0.189 Total Proposed Modified Loads: 94.81 PASS Total Baseline Loads: 96.35 1 hereby certify that the plans and specifications covered by Review of the plans and *tj4E Sr4p this calculation are in compliance with the Florida Energy specifications covered by this4r� _ 0, Code. calculation indicates compliance Ill with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 1-12-2 1 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. , S� with the Florida Energy Code. OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CARUSO RESIDENCE Bedrooms: 0 Address Type: Street Address Building Type: User ConditionedArea: 2761 Lot# OwnerName: JEAN CARUSO Total Stories: 3 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 4805 WATERSONG W Permit Office: CrossVentilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, FamilyType: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT#2 1063 10630 2 UNIT#1 1698 16198 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 142 1391.6 No 1 1 Yes Yes Yes 2 STAIRS 84 823 No 0 1 Yes Yes Yes 3 A/C1 17 167 No 0 1 No Yes Yes 4 BATH 2 54 529 No 0 1 No Yes Yes 5 DINING ROOM 320 3136 No 2 1 Yes Yes Yes 6 GREAT ROOM 288 2822 No 4 1 Yes Yes Yes 7 KITCHEN 240 2352 No 0 1 Yes Yes Yes 8 CABANA 80 720 No 0 1 Yes Yes Yes 9 FLEX SPACE 284 2556 No 2 1 Yes Yes Yes 10 ELEV. 30 270 No 0 1 Yes Yes Yes 11 ENTRY 70 630 No 0 1 Yes Yes Yes 12 FOYER 89 801 No 0 1 Yes Yes Yes 13 OFFICE 174 1740 No 2 1 Yes Yes Yes 14 EXERCISE 130 1300 No 2 1 Yes Yes Yes 15 WIC 104 1040 No 0 1 Yes Yes Yes 16 MASTER SUITE 251 2510 No 2 1 Yes Yes Yes 17 HALLWAY 142 1420 No 0 1 Yes Yes Yes 18 STAIRWAY 88 880 No 0 1 Yes Yes Yes 19 ELE 25 250 No 0 1 Yes Yes Yes 20 M BATH 149 1490 No 0 1 Yes Yes Yes 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 FlooroverGarage BEDROOM 2 ____ ---- 62 ft2 19 0 0 1 2 FlooroverGarage BEDROOM 2 ____ ---- 28 ft2 19 0 1 0 3 FlooroverGarage BEDROOM 2 ____ ---- 52 ft2 19 0 1 0 4 Crawlspace STAIRS 3.9 ft 0 27 ft2 19 0 0 1 5 Floor Over Other Space STAIRS ____ ____ 21 ft2 0 0 1 0 6 Floor Over Other Space STAIRS ____ ____ 36ft2 0 0 1 0 7 Crawlspace A/C 1 1 ft 0 16 ft2 19 0 0 1 8 Floor Over Other Space A/C 1 ____ ____ 1 ft2 0 0 1 0 9 FlooroverGarage BATH 2 ____ ____ 36 ft2 19 0 0 1 10Floor Over Other Space BATH ____ ____ 9ft2 0 0 1 0 11Floor Over Other Space BATH ____ ____ 9ft2 0 0 1 0 12FIoor Over Other Space DINING ROOM ____ ____ 102ft2 0 0 1 0 13FIoor Over Other Space DINING ROOM ____ ---- 80ft2 0 0 1 0 14FIoor Over Other Space DINING ROOM ____ ---- 68ft2 0 0 1 0 15FIoor Over Other Space DINING ROOM ____ ---- 30ft2 0 0 1 0 16FIoor Over Other Space DINING ROOM ---- ---- 40ft2 0 0 1 0 17FIoor Over Other Space GREAT ROOM ____ ____ 84ft2 0 0 0 1 18FIoor Over Other Space GREAT ROOM ____ ____ 19 ft2 0 0 1 0 19FIoor Over Other Space GREAT ROOM ____ ____ 185ft2 0 0 1 0 20FlooroverGarage KITCHEN ____ ____ 225ft2 19 0 0 1 21FlooroverGarage KITCHEN ---- ____ 15 ft2 19 0 1 0 22SIab-On-Grade Edge Insulation CABANA 18ft 0 80ft2 ____ 0 1 0 23SIab-On-Grade Edge Insulation FLEX SPACE 50 ft 0 284 ft2 ____ 0 1 0 24SIab-On-Grade Edge Insulation ELEV. 11 ft 0 30ft2 ____ 0 1 0 25SIab-On-Grade Edge Insulation ENTRY 13ft 0 70ft2 ____ 0 1 0 26SIab-On-Grade Edge Insulation FOYER 44ft 0 89ft2 ____ 0 1 0 27FIoor Over Other Space OFFICE ____ ---- 5ft2 0 0 1 0 28FIoor Over Other Space OFFICE ____ _--- 7 ft2 0 0 1 0 29FIoor Over Other Space OFFICE ____ _--- 20ft2 0 0 1 0 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 30Floor Over Other Space OFFICE ____ ---- 142ft2 0 0 1 0 31FIoor Over Other Space EXERCISE ____ ---- 130ft2 0 0 1 0 32FIoor Over Other Space WIC ____ ____ 39ft2 0 0 1 0 33FIoor Over Other Space WIC ____ ____ 65ft2 0 0 1 0 34FIoor Over Other Space MASTER SUITE ____ ____ 209ft2 0 0 1 0 35FIoor Over Other Space MASTER SUITE ---- ____ 36ft2 0 0 1 0 36FIoor Over Other Space MASTER SUITE ____ ____ 6 ft2 0 0 1 0 37FIoor Over Other Space HALLWAY ____ ____ 6 ft2 0 0 1 0 38FIoor Over Other Space HALLWAY ____ ____ 62ft2 0 0 1 0 39FIoor Over Other Space HALLWAY ____ ____ 39ft2 0 0 1 0 40Floor Over Other Space HALLWAY ____ ---- 10ft2 0 0 1 0 41FIoor Over Other Space HALLWAY ---_ ____ 25ft2 0 0 1 0 42FIoor Over Other Space STAIRWAY ____ ____ 9ft2 0 0 1 0 43FIoor Over Other Space STAIRWAY ____ ____ 2 ft2 0 0 1 0 44FIoor Over Other Space STAIRWAY ____ --__ 77ft2 0 0 1 0 45FIoor Over Other Space ELE ____ ---- 25ft2 0 0 1 0 46FIoor Over Other Space M BATH ____ ---- 149ft2 0 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1230 ft2 0 ft2 Light N 0.6 No 0.9 No 20 18.43 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1167 ft2 N N 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) DINING ROOM 0 Blown 48ft2 0.1 Wood 2 Under Attic(Unvented) GREAT ROOM 0 Blown 34 ft2 0.1 Wood 3 Under Attic(Unvented) FLEX SPACE 0 Blown 22 ft2 0.1 Wood 4 Under Attic(Unvented) OFFICE 0 Blown 174ft2 0.1 Wood 5 Under Attic(Unvented) EXERCISE 0 Blown 130ft2 0.1 Wood 6 Under Attic(Unvented) WIC 0 Blown 104ft2 0.1 Wood 7 Under Attic(Unvented) MASTER SUITE 0 Blown 251 ft2 0.1 Wood 8 Under Attic(Unvented) HALLWAY 0 Blown 142ft2 0.1 Wood 9 Under Attic(Unvented) STAIRWAY 0 Blown 88ft2 0.1 Wood 10 Under Attic(U nvented) ELE 0 Blown 25ft2 0.1 Wood 11 Under Attic(U nvented) M BATH 0 Blown 149ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o V. R- P. Ft In Ft In Area RA/alue Fraction Ah-nr 1 NE Exterior Concrete Block-Int InsuBEDROOM 2 5 13 0 9 8 125.7 ft2 0 0 0.4 0 2 NW Exterior Concrete Block-Int InsuBEDROOM 2 5 12 0 9 8 116.0 ft2 0 0 0.4 0 3 NW Exterior Concrete Block-Int Insul STAIRS 5 12 0 9 8 116.0 ft2 0 0 0.4 0 4 SE Exterior Concrete Block-Int InsuDINING ROO 5 7 0 9 8 67.7 ft2 0 0 0.4 0 5 SW Exterior Concrete Block-Int InsuDINING ROO 5 16 0 9 8 154.7 ft2 0 0 0.4 0 6 NW Exterior Concrete Block-Int InsuDINING ROO 5 20 0 9 8 193.3 ft2 0 0 0.4 0 7 SE Exterior Concrete Block-Int InsuGREAT ROO 5 22 0 9 8 212.7 ft2 0 0 0.4 0 8 SW Exterior Concrete Block-Int InsuGREAT ROO 5 12 0 9 8 116.0 ft2 0 0 0.4 0 9 NE Exterior Concrete Block-Int Insul KITCHEN 5 15 0 9 8 145.0 ft2 0 0 0.4 0 10 SE Exterior Concrete Block-Int Insul KITCHEN 5 15 0 9 8 145.0 ft2 0 0 0.4 0 11 SE Exterior Concrete Block-Int Insul CABANA 5 3 0 9 0 27.0 ft2 0 0 0.4 0 12 SW Exterior Concrete Block-Int Insul CABANA 5 6 0 9 0 54.0 ft2 0 0 0.4 0 13 NW Exterior Concrete Block-Int Insul CABANA 5 9 0 9 0 81.0 ft2 0 0 0.4 0 14 SE Exterior Concrete Block-Int InsuFLEX SPACE 5 18 0 9 0 162.0 ft2 0 0 0.4 0 15 SW Exterior Concrete Block-Int InsuFLEX SPACE 5 15 0 9 0 135.0 ft2 0 0 0.4 0 16 SW Exterior Concrete Block-Int Insul ELEV. 5 6 0 9 0 54.0 ft2 0 0 0.4 0 17 NW Exterior Concrete Block-Int Insul ELEV. 5 5 0 9 0 45.0 ft2 0 0 0.4 0 18 NW Exterior Concrete Block-Int Insul ENTRY 5 7 0 9 0 63.0 ft2 0 0 0.4 0 19 NE Exterior Concrete Block-Int Insul FOYER 5 7 0 9 0 63.0 ft2 0 0 0.4 0 20 NW Exterior Concrete Block-Int Insul FOYER 5 17 0 9 0 153.0 ft2 0 0 0.4 0 21 NE Exterior Concrete Block-Int Insul OFFICE 5 15 0 10 0 150.0 ft2 0 0 0.4 0 22 NW Exterior Concrete Block-Int Insul OFFICE 5 13 0 10 0 130.0 ft2 0 0 0.4 0 23 NE Exterior Concrete Block-Int Insul EXERCISE 5 13 0 10 0 130.0 ft2 0 0 0.4 0 24 SE Exterior Concrete Block-Int Insul EXERCISE 5 10 0 10 0 100.0 ft2 0 0 0.4 0 25 SE Exterior Concrete Block-Int Insul WIC 5 8 0 10 0 80.0 ft2 0 0 0.4 0 26 SE Exterior Concrete Block-Int InsuM1ASTER SUI 5 16 0 10 0 160.0 ft2 0 0 0.4 0 27 SW Exterior Concrete Block-Int InsuM1ASTER SUI 5 12 0 10 0 120.0 ft2 0 0 0.4 0 28 NW Exterior Concrete Block-Int InsuM1ASTER SUI 5 1 0 10 0 10.0 ft2 0 0 0.4 0 29 NW Exterior Concrete Block-Int Insul HALLWAY 5 4 0 10 0 40.0 ft2 0 0 0.4 0 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o R- Ft In Ft In Area R-Valwa Fraction Ah-nr G 30 NW Exterior Concrete Block-Int Insul STAIRWAY 5 11 0 10 0 110.0 ft2 0 0 0.4 0 31 NW Exterior Concrete Block-Int Insul ELE 5 5 0 10 0 50.0 ft2 0 0 0.4 0 32 SE Exterior Concrete Block-Int Insul M BATH 5 8 0 10 0 80.0 ft2 0 0 0.4 0 33 SW Exterior Concrete Block-Int Insul M BATH 5 16 0 10 0 160.0 ft2 0 0 0.4 0 34 NW Exterior Concrete Block-Int Insul M BATH 5 8 0 10 0 80.0 ft2 0 0 0.4 0 35 NE Garage Frame-Wood BEDROOM 2 11 42 10 420.0 ft2 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated FOYER None .39 3 7 21 ft2 WINDOWS Orientation shown istheentered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NE 1 Vinyl Low-ESingle Yes 0.65 0.25 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 2 NW 2 Vinyl Low-ESingle Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 5 Vinyl Low-ESingle Yes 0.65 0.25 N 51.2 ft2 2 ft 0 in 1 ft 4 in None None 4 NW 6 Vinyl Low-ESingle Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 5 SE 7 Vinyl Low-ESingle Yes 0.65 0.25 N 18.3 ft2 2 ft 0 in 1 ft 4 in None None 6 SW 8 Vinyl Low-ESingle Yes 0.65 0.25 N 64.0 ft2 8 ft 0 in 1 ft 4 in None None 7 NE 9 Vinyl Low-ESingle Yes 0.65 0.25 N 17.3 ft2 2 ft 0 in 1 ft 4 in None None 8 SE 11 Vinyl Low-ESingle Yes 0.65 0.25 N 17.8 ft2 8 ft 0 in 1 ft 4 in None None 9 SW 12 Vinyl Low-ESingle Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 10 SW 15 Vinyl Low-ESingle Yes 0.65 0.25 N 64.0 ft2 8 ft 0 in 1 ft 4 in None None 11 NW 18 Vinyl Low-ESingle Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 12 NW 20 Vinyl Low-ESingle Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 13 NE 21 Vinyl Low-ESingle Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 14 NW 22 Vinyl Low-ESingle Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 15 NE 23 Vinyl Low-ESingle Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 16 SW 27 Vinyl Low-ESingle Yes 0.65 0.25 N 64.0 ft2 8 ft 0 in 1 ft 4 in None None 17 NW 29 Vinyl Low-ESingle Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 18 SW 33 Vinyl Low-ESingle Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 42 ft loft 11 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000308 2235.6 122.65 230.27 .1514 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 2 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:17 36 kBtu/hr 1080 cfm 0.7 2 sys#1 2 Central Unit/ Split Single SEER:16 25 kBtu/hr 750 cfm 0.7 1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 65 ft2 DefaultLeakage A/C 1 (Default)c(Default)c 1 1 2 Attic 6 95 ft2 Attic 25 ft2 DefaultLeakage HALLWAY (Default)c(Default)c 2 2 TEMPERATURES ProgramableThermostat: N Ceiling Fans: Cool' Jan Feb Mar Apr jMa X Jun X Jul X Au X S Oct Nov Dec Heating H JanFebMarApray Jun Jul Aug Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 STAIRS Default(8lbs/sq.ft. ft2 ft 0.3 A/C 1 Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8lbs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 CABANA Default(8lbs/sq.ft. ft2 ft 0.3 FLEX SPACE Default(8lbs/sq.ft. ft2 ft 0.3 ELEV. Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 OFFICE Default(8lbs/sq.ft. ft2 ft 0.3 EXERCISE Default(8lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8lbs/sq.ft. ft2 ft 0.3 STAIRWAY Default(8lbs/sq.ft. ft2 ft 0.3 ELE Default(8lbs/sq.ft. ft2 ft 0.3 M BATH 1/12/2021 11:45 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 8 of 8