HomeMy WebLinkAboutAPPROVED M 210427 MANUAL J Project Summary Job: +� wrightsoft UNIT#1 ry Date: QUICK CALCS, INC. 317 ST LUCIE LANE,FT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For: JEAN CARUSO 4805 WATERSONG WAY,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 20047 Btuh Structure 22423 Btuh Ducts 3888 Btuh Ducts 2774 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23935 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 23937 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3642 Btuh Ducts 2155 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft�) 1698 1698 Equipment latent load 5797 Btuh Volume(ft3) 16198 16198 Air changes/hour 0.33 0.16 Equipment Total Load(Sen+Lat) 29734 Btuh Equiv.AVF(cfm) 88 44 Req.total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ANB136AO0310 AHRI ref Coil FV4CNF002L AHRI ref 10360943 Efficiency 100 EFF Efficiency 13.0 EER, 17 SEER Heating input 6.9 kW Sensible cooling 25200 Btuh Heating output 23380 Btuh Latent cooling 10800 Btuh Temperature rise 50 °F Total cooling 36000 Btuh Actual airflow 425 cfm Actual airflow 1200 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2021-Jan-1 2 11:42:42 ^.,.I ",1,.,.I---..I..,,,. Right-Sute®Uriversal 20l9 l9.0.21 RSU08101 Page 1 ACCA ...\Doaments\WrightsoftHVAC\CARUSO RESIDE NCE.rup Calc=MJ8 Front Door faces: N Project Summary Job: +� wrightsoft UNIT#2 ry Date: QUICK CALCS, INC. 317 ST LUCIE LANE,FT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For: JEAN CARUSO 4805 WATERSONG WAY,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10331 Btuh Structure 12220 Btuh Ducts 1948 Btuh Ducts 1394 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12278 Btuh Use manufacturer's data In Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 12934 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2347 Btuh Ducts 1077 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft�) 1063 1063 Equipment latent load 3424 Btuh Volume(ft3) 10630 10630 Air changes/hour 0.31 0.15 Equipment Total Load(Sen+Lat) 16358 Btuh Equiv.AVF(cfm) 55 27 Req.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ANB724AO0310 AHRI ref Coil FV4CNF003L AHRI ref 10328104 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.5 kW Sensible cooling 16800 Btuh Heating output 12101 Btuh Latent cooling 7200 Btuh Temperature rise 50 °F Total cooling 24000 Btuh Actual airflow 220 cfm Actual airflow 800 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.059 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2021-Jan-1 2 11:42:42 ^.,.I ",1,.,.I---..I..,,,. Right-Sute®Uriversal 20l9 l9.0.21 RSU08101 Page 2 ACCA ...\Doaments\WrightsoftHVAC\CARUSO RESIDE NCE.rup Calc=MJ8 Front Door faces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name UNIT#1 BEDROOM2 2 E)posed wal I 280.0 ft 25.0 It 3 Room height 9.5 It 9.8 It heat/cool 4 Room dimensions 1.0 x 142.0 It 5 Room area 1698.0 ft2 142.0 fF Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 773 721 2524 1379 118 100 349 190 4A5-2ob 0.560 n 15.68 16.16 8 0 125 129 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 18 0 282 291 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 8 0 105 108 0 0 0 0 11 4A5-2ov 0.470 n 13.16 13.55 18 0 237 244 18 0 237 244 13A-5ocs 0.125 a 3.50 1.91 337 251 879 480 127 79 278 152 1013-v 0.600 a 16.80 31.61 48 4 806 1517 48 2 806 1517 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 17 3 226 600 0 0 0 0 D 11 DO 0.390 a 10.92 10.34 21 21 229 217 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 620 589 2062 1127 0 0 0 0 10B-v 0.600 s 16.80 12.02 13 26 219 157 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 18 36 237 244 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 517 330 1156 632 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.45 8 1 125 332 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 51 6 674 1819 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 128 12 1684 4581 0 0 0 0 P 12C-Osw 0.091 2.55 1.06 387 387 986 409 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 104 104 165 142 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 450 450 214 115 62 62 29 16 F 22A-tpl 0.989 27.69 0.00 553 136 3766 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 164 23 630 0 28 5 137 0 6 c)AED excursion 2204 -112 Envelope loss/gain 17334 16727 1836 2007 12 a) Infiltration 2713 727 296 79 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 9 2070 1 230 Appliances/other 2900 0 Subtotal(lines 6 to 13) 20047 22423 2131 2316 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 158 71 14 Subtotal 20047 22423 2289 2387 15 Dud loads 19% 12% 38881 2774 19% 12%1 444 295 FFTotal room load 23935 25197 2733 2683 Air required(dm) 425 1200 49 128 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@Unversa1201919.0.21RSU08101 Pagel \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 Fron[Doorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name STAIRS A/C 1 2 E)posed wal I 12.0 It O ft 3 Room height 9.8 It heat/cool 9.8 It heat/cool 4 Room dimensions 7.0 x 12.0 It 1.0 x 17.0 It 5 Room area 84.0 ft2 17.0 ft Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 118 118 412 225 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 16.80 31.61 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 10B-v 0.600 s 16.80 12.02 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 1.06 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 27 27 13 7 16 16 8 4 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -14 0 Envelope loss/gain 424 217 8 4 12 a) Infiltration 142 38 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 566 255 8 4 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution -566 -255 -8 -4 14 Subtotal 0 0 0 0 15 Dud loads 19% 12%1 01 0 19% 12%1 0 0 Total room load 0 0 0 0 Air required(dm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 2 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name BATH 2 DINING ROOM 2 E)posed wal I O ft 43.0 It 3 Room height 9.8 It heat/cool 9.8 It heat/cool 4 Room dimensions 6.0 x 9.0 It 16.0 x 20.0 It 5 Room area 54.0 ft2 320.0 W Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 0 0 0 0 196 188 658 360 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 8 0 105 108 11 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 16.80 31.61 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 69 69 240 131 10B-v 0.600 s 16.80 12.02 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 157 106 370 202 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 51 3 674 1819 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 1.06 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 0 0 0 0 48 48 76 66 F 19C-19cscp 0.049 0.48 0.25 36 36 17 9 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 102 14 380 0 6 c)AED excursion 0 710 Envelope loss/gain 17 9 2502 3395 12 a) Infiltration 0 0 509 136 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 17 9 3011 3992 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 233 105 180 81 14 Subtotal 250 114 3191 4073 15 Dud loads 19% 12%1 491 14 19% 12%1 619 504 Total room load 299 128 3810 4577 Air required(dm) 5 6 68 218 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 3 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name GREAT ROOM KITCHEN 2 E)posed wal I 34.0 It 30.0 It 3 Room height 9.8 It heat/cool 9.8 ft heat/cool 4 Room dimensions 1.0 x 288.0 It 1.0 x 240.0 It 5 Room area 288.0 W 240.0 fF Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 147 130 454 248 1013-v 0.600 a 16.80 31.61 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 17 1 226 600 D 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 216 198 692 378 147 147 515 281 10B-v 0.600 s 16.80 12.02 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 18 18 237 244 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 118 54 188 103 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 64 3 842 2291 0 0 0 0 P 12C-Osw 0.091 2.55 1.06 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 34 34 54 47 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 84 84 40 21 225 225 107 57 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 19 2 62 0 15 2 52 0 6 c)AED excursion 808 -133 Envelope loss/gain 2114 3891 1354 1054 12 a) Infiltration 402 108 355 95 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 4 920 0 0 Appliances/other 900 2000 Subtotal(lines 6 to 13) 2516 5818 1709 3149 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 3 1 14 Subtotal 2516 5818 1712 3150 15 Dud loads 19% 12%1 4881 720 19% 12%1 332 390 Total room load 3004 6538 2044 3540 Air required(dm) 53 311 36 169 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 4 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name CABANA FLEXSPACE 2 E)posed wal I 18.0 It 50.0 It 3 Room height 9.0 It heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 80.0 ft 1.0 x 284.0 ft 5 Room area 80.0 ft2 284.0 W Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 81 81 284 155 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 16.80 31.61 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 27 14 49 27 162 162 567 310 10B-v 0.600 s 16.80 12.02 13 13 219 157 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 54 46 161 88 135 71 249 136 G 4A5-2ob 0.560 w 15.68 41.45 8 1 125 332 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 64 3 842 2291 P 12C-Osw 0.091 2.55 1.06 0 0 0 0 153 153 390 162 C 16X19-0md 0.408 1.59 1.37 0 0 0 0 22 22 35 30 F 19C-19cscp 0.049 0.48 0.25 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 80 18 498 0 284 50 1385 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 100 935 Envelope loss/gain 1336 858 3467 3863 12 a) Infiltration 196 52 358 96 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 1532 911 3826 4419 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 350 95 0 0 14 Subtotal 1882 1006 3826 4419 15 Dud loads 19% 12%1 3651 124 19% 12%1 742 547 Total room load 2247 1130 4567 4965 Air required(dm) 40 54 81 236 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 5 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name ELEV. ENTRY 2 E)posed wal I 11.0 It 13.0 ft 3 Room height 9.0 It heat/cool 9.0 It heat/cool 4 Room dimensions 6.0 x 5.0 It 10.0 x 7.0 ft 5 Room area 30.0 ft' 70.0 W Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 45 45 158 86 63 55 193 105 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 8 0 125 129 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 16.80 31.61 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 10B-v 0.600 s 16.80 12.02 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 54 54 189 103 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 1.06 0 0 0 0 54 54 138 57 C 16X19-0md 0.408 1.59 1.37 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 30 11 305 0 70 13 360 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -12 -17 Envelope loss/gain 651 177 816 275 12 a) Infiltration 119 32 76 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 771 209 892 295 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution -771 -209 420 114 14 Subtotal 0 0 1312 409 15 Dud loads 19% 12%1 0 0 19% 12%1 254 51 Total room load 0 0 1566 460 Air required(dm) 01 0 28 22 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 6 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#1 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name FOYER 2 E)posed wal I 44.0 It 3 Room height 9.0 It heat/cool 4 Room dimensions 1.0 x 89.0 It 5 Room area 89.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/W-T) (Btuh/fF) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 153 135 473 258 G 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 G 4A5-2ob 0.560 n 15.68 16.16 18 0 282 291 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 11 G 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 13A-50cs 0.125 e 3.50 1.91 63 42 147 80 G 1013-v 0.600 e 16.80 31.61 0 0 0 0 G 4A5-2ob 0.560 e 0.00 0.00 0 0 0 0 4A5-2ov 0.470 e 13.16 34.89 0 0 0 0 D 11DO 0.390 e 10.92 10.34 21 21 229 217 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 10B-v 0.600 s 16.80 12.02 0 0 0 0 G 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 13A-50cs 0.125 w 3.50 1.91 0 0 0 0 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 4A5-2ov 0.470 w 13.16 35.53 0 0 0 0 G 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 P 12C-0sw 0.091 2.55 1.06 180 180 459 190 C 16X19-0md 0.408 1.59 1.37 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 89 44 1218 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 6 c)AED excursion -59 Envelope loss/gain 2808 977 12 a) Infiltration 261 70 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 3069 1047 Less extemalload 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 3069 1047 15 Dud loads 19% 12%1 595 129 Total room load 3664 1176 Air required(cfm) 65 56 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Sute@ Uriversal 2019 l9.0.21 RSU08101 Page 7 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 Fron[Doorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#2 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name UNIT#2 OFFICE 2 E)posed wal I 140.0 It 28.0 ft 3 Room height 10.0 It 10.0 ft heat/cool 4 Room dimensions 1.0 x 174.0 It 5 Room area 1063.0 W 174.0 fF Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 420 394 1379 754 130 112 392 214 4A5-2ob 0.560 n 15.68 16.16 8 0 125 129 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 18 0 282 291 18 0 282 291 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 280 208 728 398 150 114 399 218 1013-v 0.600 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.29 72 9 1129 3045 36 2 564 1522 4A5-2ov 0.470 e 0.00 0.00 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 420 420 1470 803 0 0 0 0 10B-v 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 280 196 686 375 0 0 0 0 G 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.95 20 3 314 839 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 64 6 842 2291 0 0 0 0 P 12C-Osw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 1063 1063 1685 1454 174 174 276 238 F 19C-19cscp 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 10 -383 Envelope loss/gain 8641 10388 1914 2100 12 a) Infiltration 1690 453 338 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 6 1380 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 10331 12220 2252 2651 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 0 0 14 Subtotal 10331 12220 2252 2651 15 Dud loads 19% 11%1 19481 1394 19% 11%1 424 302 Total room load 12278 13615 2676 2954 Air required(dm) 220 800 48 174 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 8 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#2 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name EXERCISE WIC 2 E)posed wal I 23.0 It 8.0 It 3 Room height 10.0 It heat/cool 10.0 It heat/cool 4 Room dimensions 13.0 x 10.0 It 13.0 x 8.0 It 5 Room area 130.0 ft 104.0 W Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 130 94 329 180 0 0 0 0 1013-v 0.600 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.29 36 2 564 1522 0 0 0 0 4A5-2ov 0.470 e 0.00 0.00 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 100 100 350 191 80 80 280 153 10B-v 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 G 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 130 130 206 178 104 104 165 142 F 19C-19cscp 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -209 -41 Envelope loss/gain 1450 1862 445 255 12 a) Infiltration 278 74 97 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1727 2397 541 281 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 0 0 14 Subtotal 1727 2397 541 281 15 Dud loads 19% 11%1 3261 273 19% 11%1 102 32 Total room load 2053 2670 644 313 Air required(dm) 37 157 12 18 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Suite@ Universal 2019 19.0.21 RSU08101 Page 9 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#2 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name MASTER SUITE HALLWAY 2 E)posed wal I 29.0 It 4.0 It 3 Room height 10.0 It heat/cool 10.0 It heat/cool 4 Room dimensions 1.0 x 251.0 It 1.0 x 142.0 It 5 Room area 251.0 ft 142.0 ft Ty Consh'ucton U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 10 10 35 19 40 32 112 61 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 8 0 125 129 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 0.00 0.00 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 160 160 560 306 0 0 0 0 10B-v 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 120 56 196 107 0 0 0 0 G 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 64 3 842 2291 0 0 0 0 P 12C-Osw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 251 251 398 343 142 142 225 194 F 19C-19cscp 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpI 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 579 -50 Envelope loss/gain 2031 3645 463 335 12 a) Infiltration 350 94 48 13 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2381 4199 511 347 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 128 60 14 Subtotal 2381 4199 639 407 15 Dud loads 19% 11%1 4491 479 19% 11%1 121 46 Total room load 2830 4678 760 453 Air required(dm) 51 275 14 27 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� . am` Right-Srite@Uriversal20l9l9.0.21RSU08101 Page 10 .\Doe nts\WrightsoftHVAC\CA RUSO RESIDE NCE.rrp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#2 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name STAIRWAY ELE 2 E)posed wal I 11.0 It 5.0 It 3 Room height 10.0 It heat/cool 10.0 It heat/cool 4 Room dimensions 8.0 x 11.0 It ft 5.0 x 5.0 5 Room area 88.0 ft2 25.0 ft2 Ty Consh'uction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 110 110 385 210 50 50 175 96 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 1013-v 0.600 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 42.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e 0.00 0.00 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 10B-v 0.600 s 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 G 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 88 88 140 120 25 25 40 34 F 19C-19cscp 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -46 -18 Envelope loss/gain 525 285 215 111 12 a) Infiltration 133 36 60 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 657 320 275 128 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redishibution 0 0 -275 -128 14 Subtotal 657 320 0 0 15 Dud loads 19% ll%l 124 37 19% ll%l 0 0 Total room load 781 357 0 0 Air required(dm) 14 21 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1211:42:42 �� . am` Right-Sute@ Universal 201919.0.21RSU08101 Page11 .\Doe nts\WrightsoftHVAC\CA RUSO RESIDE NCE.rp Calc=MJ8 FrontDoorfaces: N + wrightsoft°° Right-J®Worksheet Job: UNIT#2 Date: By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name M BATH 2 E)posed wal I 32.0 It 3 Room height 10.0 It heat/cool 4 Room dimensions 1.0 x 149.0 It 5 Room area 149.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/F-T) (Btuh/F) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.91 80 80 280 153 G 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 G 4A5-2ob 0.560 n 15.68 16.16 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 11 G 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 13A-50cs 0.125 e 3.50 1.91 0 0 0 0 G 1013-v 0.600 e 0.00 0.00 0 0 0 0 G 4A5-2ob 0.560 e 15.68 42.29 0 0 0 0 4A5-2ov 0.470 e 0.00 0.00 0 0 0 0 D 11DO 0.390 e 0.00 0.00 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 80 80 280 153 1013-v 0.600 s 0.00 0.00 0 0 0 0 G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 13A-50cs 0.125 w 3.50 1.91 160 140 490 268 G 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 4A5-2ob 0.560 w 15.68 41.95 20 1 314 839 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 G 4A5-2ovd 0.470 w 13.16 35.79 0 0 0 0 P 12C-0sw 0.091 0.00 0.00 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 149 149 236 204 F 19C-19cscp 0.049 0.00 0.00 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 6 c)AED excursion 178 Envelope loss/gain 1600 1794 12 a) Infiltration 386 103 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1986 1898 Less extemalload 0 0 Less transfer 0 0 Redistribution 147 68 14 Subtotal 2133 1966 15 Dud loads 19% 11% 4021 224 FFTotal room load 2535 2190 Air required(cfm) 45 129 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �� rigF�tsoft° 2021-Jan-1 2 11:42:42 �� .. m`e Right-Srite@Uriversal20l9l9.0.21RSU08101 Page12 \Doa nts\WrightsoftHVAC\CARUSORESIDENCE.rp Calc=MJ8 Fron[Doorfaces: N Duct stem Summary Job: +� wrightsoft D S S y Date: UNIT#1 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project Information For: JEAN CARUSO 4805 WATERSONG WAY,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.198 in/100ft 0.198 in/100ft Actual airflow 425 cfm 1200 drn Total effective length(TEL) 253 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 c 128 5 6 0.282 4.0 Ox 0 VI Fx 12.0 165.0 st6 BEDROOM2 c 2683 49 128 0.386 7.0 Ox0 VIFx 14.4 115.0 st2 CABANA c 1130 40 54 0.256 5.0 Ox0 VIFx 35.0 160.0 st1 DINING ROOM c 4577 68 218 0.198 8.0 Ox 0 VIFx 28.0 225.0 st6 ENTRY h 1566 28 22 0.298 5.0 Ox 0 VIFx 28.0 140.0 st1 FLEXSPACE c 4965 81 236 0.253 8.0 Ox0 VIFx 38.0 160.0 st1 FOYER h 3664 65 56 0.361 5.0 Ox0 VIFx 18.4 120.0 st1 GREAT ROOM c 3269 27 156 0.243 7.0 Ox 0 VIFx 21.0 185.0 st6 GREAT ROOM-A c 3269 27 156 0.218 7.0 Ox 0 VIFx 24.0 205.0 st6 KITCHEN c 3540 36 169 0.308 8.0 Ox 0 VIFx 17.2 145.0 st6 • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 211 832 0.198 778 14.0 0 x 0 VinlFlx st6 PeakAVF 163 704 0.198 764 13.0 0 x 0 VinlFlx st2 st1 PeakAVF 214 368 0.253 469 12.0 0 x 0 VinlFlx Bolditalic values have been manually overridden wrightsoft- 2021-Jan-12 11:42:44 A= AMA=ek=Iae,•-H.11,.- 1-p-, Right-Sute®Universal 201919.0.21RSU08101 Pagel ACCP. ...\DoamentswrightsoftJHVAC\CARUSO RESIDE NCE.rup Calc=MJ8 FrontDoorfaces: N TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 425 1200 0 0 0 0 Ox 0 VI Fx wrightsoft, 2021-JarO2 11:42:44 A —=ek=Iae, — _ -.= ,—, Right-Sute®Urrversal201919.0.21 RSU08101 Page ACCP. ...\Doamerds\WrightsoftJHVAC\CARUSO RESIDE NCE.rup Calc=MJ8 FrordDoorfaces: N Duct stem Summary Job: +� wrightsoft D S S y Date: UNIT#2 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project Information For: JEAN CARUSO 4805 WATERSONG WAY,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.349 in/100ft 0.349 in/100ft Actual airflow 220 cfm 800 cfm Total effective length(TEL) 143 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk EXERCISE c 2670 37 157 0.349 7.0 Ox0 VIFx 28.4 115.0 st4 HALLWAY c 453 14 27 0.380 4.0 Ox0 VIFx 16.6 115.0 st4 M BATH c 2190 45 129 0 0 Ox 0 VI Fx 0 0 MASTERSUITE c 2339 25 137 0.374 6.0 Ox0 VIFx 18.9 115.0 st5 MASTERSUITE-A c 2339 25 137 0.384 7.0 Ox0 VIFx 15.3 115.0 st5 OFFICE c 2954 48 174 0.364 8.0 Ox 0 VIFx 22.4 115.0 s14 STAIRWAY c 357 14 21 0.377 5.0 Ox 0 VIFx 17.6 115.0 st4 WIC c 313 12 18 0.367 5.0 Ox 0 VI Fx 21.1 115.0 st5 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk s14 PeakAVF 112 378 0.349 481 12.0 0 x 0 VinlFlx st5 PeakAVF 62 293 0.367 538 10.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 220 800 0 0 0 0 Ox 0 VIFx Bolditalic values have been manually overridden wrightsoft- 2021-Jan-12 11:42:44 A= AMA=ek=Iae,•-H.11,.- ,-, Right-Sute®Universal 201919.0.21 RSU08101 Page ACCP. ...\Doaments\WrightsoftJHVAC\CARUSO RESIDE NCE.rup Calc=MJ8 FrontDoorfaces: N