Loading...
HomeMy WebLinkAboutpinder roof infoST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D • 1,2,4,5,6,7 Concrete or Clay Tile A B D, E 1,2,3,4,5,6,7 Metal Roofs A B, D Wood Shingles and A, B, D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3:4,5,6,7 ATTACHMENTS REQUIRFD As Annlirnhi,c1• - ----- - -- - •,-,-......,,.,..,�. 1. Fire Directory Listing Page 2. From Product Approval, Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST LUCIE WORK Section A (General Information) Master Permit No. Process No. Toll _ a c 0 Contractors Name: [,� ��} /� Licensed—! C[,/ J � �,� O� Job Address f �Y "� �i. C) C4 i/ ro VV b (21 `/-� ❑— Low Slope sphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) ROOF CATEGORY ❑ Mechanically Fastened Tile ❑Metal Panel/Shingles ❑ Mortar/Adhesive Set Tiles Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Maintenance Reroofing ROOF SYSTEM _41INFORMATION f Steep Sloped Roof Area (SF) ❑ Recovering Total (SF) �< Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. See Nex-t-- ParE)y /' uone 40459733.PDF Open in PDF Expert _ 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Oche; Patents Pending. - - e + i w., Premium Report 5/26/2021 IMAGE The following aerial images show different angles of this structure for your reference. Top View ST. LUCIE WORKS, Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_.._." oc @ Lap, # Rows_. @ "oc Zone 1:—" oc @ Lap, # Rows @ "oc Zone 2:____" oc @ Lap, # Rows "oc Zone 3:_.,_." oc @ Lap, # Rows_ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Notice of Acceptance Number 1040--/ y --fit �- q'i (/I M Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e:----.Zone 2n:_Zone 2r:--,Zone 3e: N/a 3r: Deck Type: Roof Slope: Type Underlayment: Self adhered 12 Insulation: N/a Fire Barrier: N/a Ridge Ventilation? Fastener Type & Spacing: N/a - self adhered Off rid e vents Adhesive Type: LN/a Type Cap Sheet: Shingles r _ --� Mean Roof Height: a g Roof Covering: Type & Size Drip Edge: '"r LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf are greater than or equal to the values Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x = _ } Mg: = Ma Product Approval M (Zone 2e: x j _ _ Mg. = Mgq Product Approval Mf. (Zone 2n: x I _) - Mg: = Mra, Product Approval Mf_ (Zone 2r: x d - _ - Mg: Mar Product Approval Mf (Zone 3e: x)--- J'-Mg' =Mrs- Product Approval Mf (Zone 3r: x = _ ---) - Mg: = M product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistanco rnn_1 r,-- - --. I VUUUL r,IJprcwe1 IVIf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 *Must be used in rnniunrtinn w1+1, 24.4 r,+ 25.9 27.1 28.2 30.0 • For Uplift based the systems use Method 3. Compare the values for F' with the values for Fr If the F' values equal to the Fr values, for each area of the roof, then are greater than or the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) -W: Cos r =F�ze Product Approval F' (Zone 2n: x L =x W:= ) -W: cos r =Frz" Product Approval F' (Zone 2r: x L =x W:= } -W: cos r =Frzr Product Approval F' (Zone 3e: x L =x W:= ) -W: cos r =Erse Product Approval F' (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Symbol Where to find CDescr'ption Design PressZones 1, 2e, 2n, 2r, 3e, 3r From applicabletable in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof H Job Site Roof SlopeJob Site Aerodynami a Product Approval Restoring M Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Product Approval Tile Dimensions L = length W = width All calculations must be submitted to the building official at the time of permit application.