HomeMy WebLinkAboutLaurieSeifert-MS78508FINALDESIGNStamped PLAN KEY SYSTEAD INFORADATION 011 momentum PV-1 COVER PAGE MODULE HANWHA Q.PEAK DUO BLK-G6+/AC 340 PV-2 SITE PLAN INVERTER ENPHASE IQ7PLUS-72-2-US PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-3 PANEL SPECIFICATION RACKING ROOFTECH RT-MINI & SNAPNRACK ULTRA 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 PV-3.1 PANEL LOAD TESTING RESULTS RAIL 60 SYSTEM 2-RAIL MOMENTUMSOLAR.COM PV-3.2 INVERTER SPECIFICATION SYSTEM SIZE (DC) 12.58 KW PROFESSIONAL ENGINEERING PV-3.3 COMBINER BOX SPECIFICATION LOCATION 27.3205014,-80.3445855 PV-3.4 JUNCTION BOX SPECIFICATION ``\``\`All I IMq PV-3.5 ATTACHMENT DETAIL \� ?P F �CENS 'q PV-3.6 STRUCTURAL CALCULATION PV-3.7 SEALANT SPECIFICATION No PE86753 HANWHA Q.PEAK DUO BLK-G6+/AC 340 PV-3.8 SEALANT SPECIFICATION CONT. 340 WATT MODULE PV-3.9 CONDUIT SUPPORT SPECIFICATION 68.5 X 40.5 X 1.57 Q STATE OF SEE DATASHEET P.•' ` PV-4 THREE LINE DIAGRAM ��/ s 40RID PV-4.1 ELECTRICAL NOTES PV-4.2 EQUIPMENT LABELS GENERAL NOTES: Digitally signed by Mina A Makar. PV-5 STRUCTURAL CERTIFICATION THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER Reason : This item has been STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA electronically signed and sealed by BUILDING CODE, 7TH EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES &ORDINANCES. Mina A. Makar, PE 86753, COA# BUILDING INFORMATION/B.O.M. 33404] on the Date and Time Stamp # STORIES 1/15 ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. shown using a digital signature. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES Printed copies of this document are ROOF AREA 2799.82 ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10-INCHES ABOVE THE SURFACE OF not considered signed and sealed P.V. AREA 712 THE ROOF FOR FLAT ROOF. and the signature must be verified on any electronic copies ROOFING TYPE ASPHALT SHINGLES ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY - RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. SOLAR CONTRACTOR ROOF PITCH 14 ALL DESIGN CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE CAMERO LICENSEN , CERTIFIED SOLAR CONTRACTOR OR LICENSE NUMBER:CVC57036 STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF MOMENTUM SOLAR # RAILS 18 CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED 5728 MA]OR BLVD. SUITE 307,ORLANDO FL.32819 # L-FOOT ATTACHMENTS W SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS CUSTOMER INFORMATION RnOFTFCH 65 AND STRUCTURES FOR HUMAN HABITATION. - LAURIE SEIFERT- MS78508 # MODULES 37 268 NE SOLIDA DR INVERTER PLACEMENT: PORT SAINT LUCIE, FL 34983 # INVERTERS 37 7724867082 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE PV SYSTEM INFORMATION # SKIRTS 11 OF EACH MODULE. SYSTEM SIZE (DC): 12.58 KW # ENPHASE COMBINER BOXES 1 37 MODULES: HANWHA Q.PEAK DUO STRUCTURAL STATEMENT: BLK-G6+/AC340 EATON 60A FUSIBLE SOLAR AC 37 INVERTERS: ENPHASE DISCONNECT 1 THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE IQ7PLUS-72-2-US SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 60A FUSES 2 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND PROJECT INFORMATION 125A LINE TAPS 2 SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES. INITIAL DATE: 6/1/2021 DESIGNER:Mz REV: DATE: DESIGNER: FSEC CERTIFICATION STATEMENT: REV: DATE: DESIGNER: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COVER PAGE COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 PV- 1 60'-112" ROOF PANEL COUNT TILT AZIMUTH SHADING R1 32 140 164° 99% momentum R2 5 120 344' 97% SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING �x ,,�CENSF i CB No PE86753 SOLAR - AC 4: DISC MSP O i C STATE OF!� �( � RAFTER SPACING �ORIDQ'• . ��41 61 -7 4" O.C. (TYP) 6'_0 6'-0" ��`" GUTTER ELECTRICAL EQUIPMENT /////OVAL 0\\10 �� Digitally signed by Mina A Makar. Z2e �° I PZ3e �3 PZ3e 61'-7" 6'-0" Reason : This item has been electronically signed and sealed by ° J-BO [Mina A. Makar, PE 86753, COA# PZ2n I 334041 on the Date and Time Stamp P 1 ° Pzi Ishown using a digital signature. TII O O1 7 Printed copies of this document are -0PZ3r — —PZ2Ir I I 6'-0" not considered signed and sealed I I I RIDGE 1/1 I Mir I I� I and the signature must be verified —I — on any electronic copies - 05-00 -0 PZ ? TO 0� o� o r 0 0 0 6-0" CLAMPING MAX SPACING IN ZONE 1 48" O.0 SOLAR CONTRACTOR AND IN ZONE 2 48 O.0 AND ZONE 3 24 CAMERONCHRISTENSEN O.0 CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MMENTUM SOLAR O - O - O O O * I - 0 O 0- 5728 MAJOR BLVDO SUITE 307,ORLANDO FL.32819 PZ�77 1 Z Z1— Z n 6 -0" CUSTOMER INFORMATION 6'- i o 0 0 o SYMBOL LEGEND i LAURIE SEIFERT-MS78508 Pz I P 1 MSP MAIN SERVICE PANEL ® CHIMNEY 268 NE SOLIDA DR 6' 0" I 0 0 0 0 0 0 0 0 0 0 0 0 0 '_0" PORT SAINT LUCIE, FL 34983 PZ3e i� L-PZ2e � - 0 1 _ PZ2 PZ3e 7724867082 SP SUB-PANEL SKYLIGHT PZ3e _ PV SYSTEM INFORMATION UTILITY METER 6'-0" GUTTER GUTTER PZ3e PZ2e PZ2e O ® VENT SYSTEM SIZE(DC): 12.58 KW �' 37 MODULES: HANWHA Q.PEAK DUO 6'-0" „ GUTTER , „ 6'-0" 3 5 ALCAR SOLAR AC DISCONNECT p PIPE VENT BLK-G6+/AC 340 6,-0 60'-112" 6'-0" 6 -0 D15C 37 INVERTERS: ENPHASE IQ7PLUS-72-2-US SITE PLAN FRONT OF RESIDENCE uDc UTILITY DISCONNECT FAN SCALE: 1/8" = 1'-0" NE SOLIDA DR LC LOAD CENTER SATELLITE DISH PROJECT INFORMATION NOTE: INITIAL DATE: 6/1/2021 DESIGNER:MZ 1. ROOF COVERING MATERIAL IS COMPOSED OF ASPHALT SHINGLES N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS REV: DATE: DESIGNER: 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS. . THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING c6 POINT COMBINER BOX MIN 3'x3'GROUND ACCESS REV: DATE: DESIGNER: VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL SITE PLAN PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS MODULE PITCH DIRECTION 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW ��� WIND PRESSURE ZONE LINES momentum SOLAR bored by MECHANICAL SPECIFICATIONS DUO 7 Format 68.5 x 40.6 x 1.57in(including frame) PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR (1740 x 1030 x 40 mm) °&fi"'0n'"0 >b.o•,aw.ml 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ aAu tammml Weight 47.2 lbs(21.4 kg) (732)902-6224 Front Cover 0.13in(3.2mm)thermally pre-stressed glass77 + MOMENTUMSOLAR.COM with anti-reflection technology .Wa„a„RP,,,.,anrtasmm Back Cover Composite film aaer,Raz_, PROFESSIONAL Frame Black anodized aluminum ENGINEERING Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ao.s-u__I Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71in(53-101 x 32-60 x 15-18mm), Protection class IP67,with bypass diodes \._ `\\\ Cable 4mm2 Solar cable;(+)>45.3in(1150mm),H- 33.5in(850mm) .w.,oENA a.pmPs.row `\ A A. M14 Connector Staubli MC4;IP68 ) ,` `' CEN sF /�Iamm, pE a„aesat amml I '•'9,p / a�a•,RRAmr.,I�z4�R•I,amml AC OUTPUT ELECTRICAL CHARACTERISTICS No PE86753 -_ G.PEAK DUO 1 1 B 6 I07PLUS-72-ACM-US ORIQ7PLUS-72-E-ACM-US _ 7[ .*. •' 7C Peak Output Power [VA] 295 AC Short Circuit Fault Current over 3 Cycles 5.8 Arms 340-345 Max.Continuous Output Power [VA] 290 Max.Units per 20A(L-L)Branch Circuit 13 Nominal(L-L)Voltage/Range IV] 240/211-264 Overvoltage Class AC Port III STATE OF Q.ANTUM r�YR (5%%G Max.Continuous Output Current [A] 1.21 AC Port Backfeed Current 18mAWITH ' '• � Nominal Frequency [Hz] 60 Power Factor Setting 1BRAND PV Extended Frequency Range [Hz] 47-68 Power Factor(adjustable) 0.851eading...0.851agging 2020 DC ELECTRICAL CHARACTERISTICS USA Warranty Q CELLS Yield Security POWER CLASS 340 345 340 345 ;can°„rerce M INIMU M PERFORMANCE AT STANDARD TEST CON DITIO NIS,STC'(POWER TOLERANCE+5W/-0 W) Digitally signed by Mina A Makar. Min.Power at MPP' PMPP [W] 340 345 Min.Current at MPP IMPP [A] 10.02 10.07 Min.Short Circuit Current' Iso [A] 10.52 10.58 Min.Voltage at MPP VMPP IV] 33.94 34,25 Reason : This item has been Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Min.Open Circuit Voltage' Vcc (VI 40.66 40.92 Min.Efficiency' A [%] >19.0 19.3 electronically signed and sealed by Higher yield per surface area,lower BOS costs,higher 'Measurement tolerances PNPP±3%;Ix;Voc±5%at STC:1000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3 power classes,and an efficiency rate Of Up to 19.5%. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE [Mina A. Makar, PE 86753, COA# INNOVATIVE ALL-WEATHER TECHNOLOGY i� Atl least d - 33404] on the Date and Time Stamp eas o nominal power during 1O , Optimal yields,whatever the weather with excellent u; +e ------------------------------- first year.Thereafter max.0.54% u �J ws degradetionperyear.Atleast93.1% 6 shown using a digital signature. low-light and temperature behavior. LL -� >oo > RR of nominal power up to 10 years.At of least 85%of nominal power up to W i ar ENDURING HIGH PERFORMANCE -o t.. 25years. ; W --r----- -----r----I'--- < Printed copies of this document Long-term yield security with Anti LID Technology,Anti PID Allda[awithinmeasurementtoleranc- 5 not considered signed and sealed e ` Technology',Hot-Spot Protect,Traceable Quality Tra.Q"u. es.Full warranties in accordance with +� mo .00 am aaa f .P the warranty terms of the QCELLS o and the signature must be verified V sales organization of n your respective 60p IRRAMANCEIW/m'1 R EXTREME WEATHER RATING p ®� or. epps country. Typical moduHigh-tech aluminum alloy frame,certified for comparsonntoSTCf conditions under low irradiance (25°C,1000W/m)conditionsin on any electronic copies high snow(5400 Pa)and wind loads(4000Pa). $ -05-00 TEMPERATURE COEFFICIENTS ti A RELIABLE INVESTMENT Temperature Coefficient of lsc a [%/K] +0.04 Temperature Coefficient of Vcc Ii [%/K] -0.27 J SOLAR CONTRACTOR g� Inclusive25-year product warranty and25-year Temperature Coefficient ofPMPP y [%/K] -0.36 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m CAMERONCHRISTENSEN linear performance warranty2. o CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 PROPERTIES FOR DC SYSTEM DESIGN o MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 STATE OF THE ART MODULE TECHNOLOGY Maximum System Voltage Vsys IV] 1000 PV Module Classification Class II Q.ANTUM DUO Technology and the integrated high-powered Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 1703 TYPE 2 CUSTOMER INFORMATION EnphaselQ7+Microinverter achieving maximum system efficiency. Max.Design Load,Push/PUII' [lbs/ft2] 75(3600 Ps)/55(2667Pa) Permitted Module Temperature -40°Fupto+185°F u Max.Test Load,Push/Pulls [lbs/ft2] 113(5400 Pa)/84(4000Pa) on Continuous Duty (-40°C up to+85°C) 0 LAURIE SEIFERT- MS78508 RELIABLE ENERGY MONITORING q Seamless management with the intelligent Enphase See Installation Manual 268 NE S O LI DA DR Enlighten"^monitoring system. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION PORT SAINT LUCI E, FL 34983 Number of Modules per Pallet 26 7724867082 RAPID SHUTDOWN COMPLIANT Solar module:UL 1703, P a U.S.Patent No.9,893,215(solar cels); Built-in rapid shutdown with no additional components required. Number of Pallets per 7railer(24 t) 28 PV SYSTEM INFORMATION Enphesa micro inverter:UL 1741-$A,UL 621p9-1, UL1741/IEEE1547,FCC Part 15Class B, SP Number of Pallets per 40'HC-Container(26 t) 26 x SYSTEM SIZE (DC): 12.58 KW 'APT test conditions according to IEC/TS 62804-1:2015.method8-1500V,168h ICES-0003 CIess B,CAWCSA-C22.2 N0.1071-01, Gu.-,,,uS THE IDEAL SOLUTION FOR: 9 ( ) Rapid Shutdoym Compliant per NEC-2014 PalletDimensions(LxWxH) 70.1x42.5x47.6in(1780x1080x1208mm) 37 MODULES: HANWHA Q.PEAK DUO a See data sheet on rear for further information &2017&C22.1-2015 V V 9n��...,"' Pallet Weight 13101bs(594 kg) � C9 Rccltoparrays.n N BLK-G6+ AC 340 residential buildings Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use 37 INVERTERS: E N P H AS E of this product. IQ7PLUS-72-2-US CELLS 400 Spectrum LLS Center rive,Suite Engineered in Germany r. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA ITEL+1 949 748 59 96 1EMAIL inquiryeus.q-cells.coml WEB www.q-cells.us PROJECT INFORMATION INITIAL DATE: 6/1/2021 DESIGNER:MZ REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL SPECIFICATION PV-3 momentum Q CELLS SOLAR Document issue date:2021-02-19 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ This authorization document("Authorization Document")is issued and released by Hanwha Solutions Corporation on behalf (732)902-6224 of the respective warrantor as named in the Hanwha Q CELLS Limited Warranty for crystalline photovoltaic modules MOMENTUMSOLAR.COM ("Warranty"). PROFESSIONAL ENGINEERING 1. We hereby confirm that the MODULE TYPE mounted in the CLAMP POSITION referenced in Table A, is in compliance with the requirement of UL1703/61730,and has successfully passed a pull test load of 4000 Pa and a max pull load of 5400 Pa in accordance with the UL 61730 standard ��� P ••/~���/� Table A. � MODULE TYPE MOUNTING OPTION OF CLAMP TEST LOAD[Pa] DESIGN LOAD[Pa] No PE86753 POSITION[mm] (Push/Pull) (Push/Pull) _ Q.PEAK DUO BLK-G6+/HL Clamping at long �_� �250—350 +5400/-5400 +3600/-3600 � Q.PEAK DUO BLK-G6+/AC modules sides - I- At I (9.84-13.78 in) (112.8 psf) (75.2 psf) i C STATE OF i- - Q.PEAK DUO-G6+/AC ("CL1") �*� j°�ORIDQG• NOTE: /S/DIVAI. `�C'� Distance between outer edge of module and middle of the clamp 1 1]1 1 \ The stability of the mounting system including the clamps and fixation of the modules must be secured by a certified system Digitally signed by Mina A Makar. supplier. Reason : This item has been electronically signed and sealed by 2. As long as you adhere to the terms and conditions of this Authorization Document and the Warranty,the MODULE [Mina A. Makar, PE 86753, COA# TYPE,mounted and clamped as instructed in the installation manual,shall be covered by the Warranty 334041 on the Date and Time Stamp 3. Please note that no revisions are made to the existing terms of the Warranty.The terms of the Warranty shall remain shown using a digital signature. AS IS,except as specifically referenced in this Authorization Document Printed copies of this document are 4. The Warranty shall not apply to damages of the solar module backsheet and junction box caused by the mounting not considered signed and sealed subconstruction. and the signature must be verified 5. Customer may not transfer,assign or delegate any of its rights or obligation hereunder to any other person,without on any electronic copies the prior written consent of Hanwha Solutions Corporation 6. Any information contained in this Authorization Document is confidential and no part of this Authorization SOLAR CONTRACTOR Document may be reproduced,stored in a retrieval system or transmitted in any form or by any means,electronic, CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 mechanical,photocopying,recording or otherwise,without the prior written consent of Hanwha Solutions MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 Corporation CUSTOMER INFORMATION LAURIE SEIFERT-MS78508 268 NE SOLIDA DR PORT SAINT LUCIE, FL 34983 7724867082 PV SYSTEM INFORMATION SYSTEM SIZE(DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO BLK-G6+ AC 340 37 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION Q CELLS is a brand of Hanwha Solutions Corporation. INITIAL DATE: 6/1/2021 DESIGNER:MZ REV: DATE: DESIGNER: Hanwha Solutions Corporation REV: DATE: DESIGNER: 23F,86 Cheonggyecheon-ro,Jung-gu,Seoul,Korea 04541 PANEL LOAD TESTING T.+82(0)2 6049 0520,F:+82(0)2 729 1372,W:\ .q-cells.com w RESULTS PV-3 . 1 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM Data Sheet Enphase IQ 7 and IQ 7+ Microinverters PROFESSIONAL Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US I07PLUS-72-2-US/I07PLUS-72-9-US Region:AMERICAS ENGINEERING Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and T.Z-cell PV modules Maximum input Peak power tracking kit age 48V 0 voltage 27 V-37 V 27 V-45 V ��``` A A• Mq ,�//// Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22V/60V X _1F ,••'%,%CENSF j Max DC short circuit current(module Isc) 15 A 15 A r Enphase The high-powered smart grid-ready Overvoltage class DC port II II Enphase IQ 7 Micro'"and Enphase IQ 7+MicrOTM DC port backfeed current oA oA No PE86753 Q 7 a n d IQ 7 PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; = ; dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter oc 4:, Microinverters Peak output power 250 VA 295 VA v Part of the Enphase IQ System,the IQ 7 and Q STATE OF p y Maximum continuous output power 240 VA 290 VA � � •, IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/ranges 240 V/ 208v/ 240 V/ 208V/ '4, 0RIDQ'• 'G'N' 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy',Enphase IQ Battery'",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 v) 1.21 A(240 v) 1.39 A(208 V) Enlighten'"monitoring and analysis software. Nominal frequency 60 Hz 60 Hz ��OVAL \;`��� Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3cycles 5.8Arms 5.8Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) Digitally signed by Mina A Makar. Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0A Reason : This item has been enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 electronically signed and sealed by warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7lagging 0.7 leading...0.7lagging EFFICIENCY @240v @208V @240v @208V [Mina A. Makar, PE 86753, COA# Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% 33404] on the Date and Time Stamp CEC weighted efficiency 97.0% 97.0% 97.0% 97.0 MECHANICAL DATA shown using a digital signature. Ambient temperature range -400Cto+650C Relative humidity range 4%to 100%(condensing) Printed copies of this document are Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) not considered signed and sealed Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Lightweight and simple Adaptors for modules with MC4 or UTX connectors: and the signature must be verified Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 -PV2 toUTX:order ECA-S20-S25 on any electronic copies Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans SOLAR CONTRACTOR Approved for wet locations Yes Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure MOMENTUM SOLAR Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 UL listed FEATURES CUSTOMER INFORMATION Communication Power Line Communication(PLC) 4 Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. LAURIE SEIFERT-MS78508 Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 268 NE SO LI DA DR h; Complies with advanced grid support,voltage and disconnect required by NEC 690. PORT SAINT LUCI E FL 34983 frequency ride-through requirements Compliance CA Rule 21(UL 1741-SA) ' • Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, 7724867082 grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and PV SYSTEM INFORMATION Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Meets CA Rule 21(UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. SYSTEM SIZE(DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO *The IQ 7+Micro is required to support 72-cell modules.V BLK-G 6+ AC 340 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/support/module-comoatibility.2.Nominal voltage range can be extended beyond nominal if required by the utility. 37 INVERTERS: E N P H AS E 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. I f 17 P L U S-72-2-U S E N P H AS E To learn more about Enphase offerings,visit enphase.com E N P H AS E `c To learn more about Enphase offerings,visit enphase.com / ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 PROJECT INFORMATION INITIAL DATE: 6/1/2021 DESIGNER:MZ REV: DATE: DESIGNER: REV: DATE: DESIGNER: INVERTER SPECIFICATION PV-3 . 2 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 Data Sheet Enphase IQ Combiner 3 MOMENTUMSOLAR.COM Enphase Networking MODEL NUMBER _ PROFESSIONAL IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy-printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ENGINEERING ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect' CELLMODEM-03(4G/1 2-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, �^•.•• ••.• // CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) �� X� Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). 'j$F Enphase The Enphase IQ Combiner 3'"with Enphase CT-200-SPLIT •Consumption monitoring is required for Enphase Storage Systems _� i IQ Envoy'"consolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge''storage and Enphase NO PE86753 Q Combiner 3 COMMS-KIT-01 Enpower'"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. = (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 �� '/. BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 Q STATE OF BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 •• �(/ providing a consistent,pre-wired solution for � � •. ` EPLC-01 Power line carrier(communication bridge pair),quantity-one pairFLORIDP residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 � 01VA1. busbar assembly. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Digitally signed by Mina A Makar. Eaton BR series busbar rating 125A Reason : This item has been Max.continuous current rating(output to grid) 65A electronically signed and sealed by Max.fuse/circuit rating(output) 90A [Mina A. Makar, PE 86753, COA# Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Smart Max.continuous current rating(input from PV) 64A 334041 on the Date and Time Stamp Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included shown using a digital signature. and control Production Metering CT 200 A solid core pre-installed and wired toIQEnvoy Printed copies of this document are Flexible networking supports Wi-Fi, MECHANICAL DATA i or cellular Ethernet, not considered signed and sealed ° Y Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). g Optional AC receptacle available for PLC Weight 7.5 kg(16.5 lbs) and the signature must be verified bridge Ambient temperature range -401Cto+46*C(-40eto1150F) on an electronic copies Provides production metering and optional y p consumption monitoring Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors SOLAR CONTRACTOR i Simple 60 A breaker branch input:4 to 1/0 AWG copper conductors CAMERON CHRISTENSEN �•` Main lug combined output: 10 to 2/0 AWG copper conductors CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 Reduced size from previous combiner Neutral and ground: 14 to 1/0 copper conductors MOMENTUM SOLAR Centered mounting brackets support single Always follow local code requirements for conductor sizing. 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 Altitude To 2000 meters(6,560 feet) stud mounting CUSTOMER INFORMATION � INTERNET CONNECTION OPTIONS Supports back and side conduit entry Integrated Wi-Fi 802.11b/g/n j • Up to four 2-pole branch circuits for 240VAC LAURIE SEIFERT-MS78508 1 plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) 268 NE SO LI DA DR 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M) PORT SAINT LUCI E, FL 34983 (not included) COMPLIANCE 7724867082 Reliable Compliance,Combiner UL 1741,CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 PV SYSTEM INFORMATION Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certifiedNEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 SYSTEM SIZE(DC): 12.58 KW 31Renclosure 37 MODULES: HANWHA Q.PEAK DUO Five-year limited warranty BLK-G6+/AC 340 U` ULlisted To learn more about Enphase offerings,visit enphase.com 37INVERTERS: ENPHASE LISTED 02018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the I Q7 P LU S-72-2-U S E N P H A S E trademarks of Enphase Energy,Inc. E N P H A S E To learn more about Enphase offerings,visit enuhase.com `0 2019-11-04 PROJECT INFORMATION INITIAL DATE: 6/1/2021 DESIGNER:MZ REV: DATE: DESIGNER: REV: DATE: DESIGNER: COMBINER BOX SPECIFICATION PV-3 . 3 momentum soltectionTM SOLAR try vynekier PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL RJ-1 ENGINEERING Residential Transition Box ♦XXX````AI The Soltection RJ-1 rooftop junction box with flashing ` 1�x,. �,,CENSF r � provides a safe,secure,and NEMA 4X watertight % No PE86753 solution for the Solar installer to penetrate the roof for attic runs and make the proper wire connections. 40 The product is designed to be simple to install, - Q STATE OF F�ORIDN minimize time on the roof,while additionally providing higher levels of protection for the point of '�� r�ONAL 0?�♦ penetration in the roof as well as electrical connections inside the junction box. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA# Key Features Specifications 334041 on the Date and Time Stamp shown using a digital signature. • Designed specifically for solar installations Enclosure Printed copies of this document are • Light weight not considered signed and sealed • Non-metallic---Will NOT rust/corrode Material:Polycarb blend w/LIV inhibitors and the signature must be verified UV Stabilized:Yes • Easy to drill/modify Impact Resistance:Yes on any electronic copies • Captive screws in cover-will not fall out Weight:2.731b • Minimal design,small footprint Color:Graphite Black SOLAR CONTRACTOR CAMERON CHRISTENSEN • NEMA 4X rated CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR • All roof penetrations cover 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 by Nema 4x enclosure Dimensions CUSTOMER INFORMATION LAURIE SEIFERT-MS78508 Flashing Dimensions(Approximiate):13"x 18" 268 NE SOLIDA DR Enclosure Dimensions(Approximate):8"x 8" PORT SAINT LUCIE, FL 34983 Total Product Height:3.5" 7724867082 Cubic Inches:224 Cubic Inches PV SYSTEM INFORMATION us SYSTEM SIZE(DC): 12.58 KW ce 37 MODULES: HANWHA Q.PEAK DUO LISTED BLK-G6+ AC 340 37 INVERTERS: ENPHASE IQ7PLUS-72-2-US Soltection by Vynckier PROJECT INFORMATION Vynckier Enclosure Systems 271 McCarty Street,Houston,TX 77029 USA INITIAL DATE: 6/1/2021 DESIGNER:MZ +1.866.227.0577 www.soltection.com REV: DATE: DESIGNER: REV: DATE: DESIGNER: JUNCTION BOX SPECIFICATION JUNCTION BOX SPECIFICATION FOR SHINGLE ROOFS PV-3 .4 OVERVIEW OF THE SNAPNRACK ULTRA RAIL SNAPNRACK ADJUSTABLE END CLAMP. BIN: REVISION: SNAPNRACK UR-60 RAIL AND SPLICE DETAILS BIN: REVISION: SYSTEM INSTALLED ON A TYPICAL ROOF SELECT TO MATCH MODULE HEIGHT 1/2"MODULE SPACING ALL lsnnnl9 xEw oerArL N/A iiirixu99 nao-nnlae REFER TO SNAPNRACK INSTALLATION MANUAL FOR SNAPNRACK,MID CLAMP. -FORE R D TO TASPECIFIC"ATTACHMENT DETAIL" 5/16"DIA.HARDWARE TORQUE SPECIFICATIONS momentum FOR DETAILS ON ATTACHING AND SELECT TO MATCH = _ — 0 WATERPROOFING THE VARIOUS MODULE HEIGHT PV MODULE,TYP. — — — _ SPLICE ED-ANPOSITIONING: SNAPNRACK ROOF ATTACHMENT PRODUCTS APPROVED-ANYWHERE ALONG RAIL SPAN THERMAL EXPANSION GAP: PV MODULE,TYP. SNAPNRACK,ULTRA RAIL PV MODULE FRAME,TYP. BETWEEN TWO ROOF ATTACHMENTS 3/8'.-5/8" SNAPNRACK,UR-60 SPLICE SOLAR REFER TO SPECIFIC"COMPONENT DETAIL' NOT APPROVED-RAIL OVERHANGS/ FOR DETAILS ON VARIOUS SNAPNRACK (�/y/J��/J SNAPNRACK,UNIVERSAL END CLAMP. CANTILEVERS SNAPNRACK,UR-60 RAIL ACCESSARY AND COMPONENT PRODUCTS `�! MODULE HEIGHT AGNOSTIC AND SNAPNRACK,ULTRA RAIL HIDDEN BENEATH MODULES BOTH THE SNAPNRACK,UNIVERSAL END • DETAIL A: DETAIL B: DETAIL C: SNAPNRACK,ULTRA RAIL PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR CLAMP AND SNAPNRACK,ADJUSTABLE END SNAPNRACK,UR-60 RAIL CLAMP CAN BE USED ON END MODULES SNAPNRACK,ADJUSTABLE END CLAMP SNAPNRACK,MID CLAMP SNAPNRACK,UNIVERSAL END CLAMP FASTENS TO ROOF ATTACHMENTS 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ MODULES MAY BE CLAMPED ON SHORT OR PV MODULE,TYP. VIA THE"SNAPNRACK,ULTRA RAIL (732)902-6224 LONG SIDE PER MODULE MANUFACTURER MOUNTING HARDWARE" MOMENTUMSOLAR.COM REQUIREMENTS RAILS MAY BE MOUNTED UP/DOWN OR SNAPNRACK,ULTRA SNAPNRACK,UR-60 SPLICE INSTALLED,TOP SNAPNRACK,UR-60 RAIL PROFESSIONAL ACROSS THE SLOPE OF THE ROOF __ RAIL SPRING AND SNAPNRACK,ULTRA RAIL SPRING CAGE,OPTIONALREFER TO L SPAN"DISTANCE BETWEEN ENGINEERING MANUAL FOR 5/116"DIA' OVERHANG"RACK INSTALLATION "RAIL END HARDWARE TORQUE DISTANCE ROMRAIL END �ENCENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT, 5/I6"DIA.-18 BOLT,S.S. SPECIFICATIONS TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE LENGTH VARIES NOT TO EXCEED 34%OF ALLOWABLE SPAN STRUCTURAL MEMBER 5/I6"DIA.-18 X 3/4"FLANGE BOLT,S.S. To ALL FASTENERS TO TOR THE SPECIFIED VALUES PRIOR—" SNAPNRACK,MID CLAMP. TORQUE ALL FASTENERS TO SNAPNRACK,ADJUSTABLE " TO INSTALLING PV MODULES SELECT TO MATCH MODULE HEIGHT SNAPNRACK,ULTRA—' THE SPECIFIED VALUES PRIOR A END CLAMP.SELECT TO "MODULE OVERHANG" RAIL MOUNT,TAPPED / TO INSTALLING PV MODULES ��•• ••• '� MATCH MODULE HEIGHT SNAPNRACK,ULTRA RAIL DISTANCE FROM RAIL SIDE TO MODULE EDGE. J/ SNAPNRACK,UR-60 BONDING BRIDGE �` ` •�' �CEN�• �� NOT TO EXCEED 25%OF MODULE LENGTH OR SNAPNRACK,ULTRA SNAPNRACK,UR-60 SPLICE •••, PV MODULE,TYP. MODULE MANUFACTURER RECOMMENDATIONS RAIL MOUNT,THRU ��____Jf ATTACHMENT,VAIRES p �'• •� .00 SNAPNRACK,ULTRA RAIL MOUNTING HARDWARE 0-RING FOR 1/4"BOLT No PE86753 SNAPNRACK,UR-60 SPLICE INSTALLED,FRONT S APNRACK,ULTRA RAIL SNAPNRACK,UR-60 SPLICE,SLEEVE _ N • , END CAP,OPTIONAL Q STATE OF ,Q -� I�1✓2"'I ROOFING MATERIAL, '•••. COMP SHINGLE SHOWN,TYP. . O RID 2 1/q" z 1/q" ROOF SHEATHING AND �' 'O UNDERLAVMENTMATERIAL, �' �A�ME 1'!T STRUCTURAL MEMBER, SNAPNRACK ROOF ATTACHMENT,VARRES WITH 'I I"I I'I``` WOODEN RAFTERSHOWN,TYP. ROOF TYPE.REFER TO SPECIFIC"ATTACHMENT DETAIL" SNAPNRACK,UR-60 SPLICE,EXPLODED FOR ATTACHMENT&WATERPROOFING DETAILS UR-40 RAIL I UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS SNAPNRACK,UR-60 SPLICE SNAPNRACK,UR-60 RAIL Digitally signed by Mina A Makar. n I� p�L�- Sunrun South LLC DESIGNER: M.AFFENTRANGER SCALE: DRAWING NUMBER: DESCRIPTION: REV n f� I� �L�• Sun—South LLC DESIGNER: M.AFFENTRANGER SCALE: DRAWING NUMBER: DESCRIPTION: 11EV: �OO���f1�l�W °""'°'°'°"'°'°°°°""""°"'"' g" DRAFTER:M.AFFENTRANGER DNS SNR-DC-00329 ULTRA RAIL,SYSTEM OVERVIEW,TYPICAL 1 �II II���II�QW °"°"•'°"""'°°°"`""""'°"'"' DRAFTER:M.AFFENTRANGER DNS SNR-DC-00331 ULTRA RAIL,COMPONENT DETAIL,UR-60 RAIL 2 Reason : This item has been So ... DATE' 5�7�2019 3 366 Solar Mountin 5°lutions " DATE' 5�7/2019 AND SPLICE APPROVED BY: B.PETERSON 9 APPROVEDBY: B.PETERSON electronically signed and sealed by [Mina A. Makar, PE 86753, COA# 33404] on the Date and Time Stamp • •- •• •• ' • ' ••' shown using a digital signature. RT-MINI is suitable for T� Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Printed copies of this document are Components Dimensions in(mm) not considered signed and sealed mounting any rail system RT2-00-MINIBK with a conventional L-Foot. PAT:PENDING g ° 0 31/2(90) and the signature must be verified � < o on any electronic copies P C MINI base:20 ea. �- - ' a RT- 40 ea. Rafter installation SOLAR CONTRACTOR Extra RT-Butyl:10 ea. hin Optional item 5 x 60mm Mounting screw(RT2-04-SD5-60):100 eadBag CAMERON CHRISTENSEN k i ;,,.,. 5/16"Hex bolt,washer&nut set(RTA BN30SL-U8):100 ea./Bag CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 RT-Butyl(RT2-04-BUTVLT):10 ea./Box MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 + - RT-Butyl is Roof Tech's flexible flashing used in CUSTOMER INFORMATION J� 700,000 residential PV systems for the last 24 years. It is the first PV mounting system with Flexible E �► Flashing certified by thelCC. LAURIE SEIFERT- MS78508 �• Metal Flashing Retrofit Flexible Flashing .�" 268 NE SOLIDA DR PORT SAINT LUCIE, FL 34983 \ ` 7724867082 OSheddingwater? Deck installation Dual bolt design: M8 or 5/16 ppppp- PV SYSTEM INFORMATION for L-Foot & 1/4" for EMC SYSTEM SIZE (DC): 12.58 KW Easy tapping 1/4 HexBoil 37 MODULES: HANWHA Q.PEAK DUO ICCscrew guide upper channel 100%Waterproof BLK-G6+/AC340 ICC ESR-3575 ASTM2140 testing UV testing(7500 hrs.) 37 INVERTERS: ENPHASE IQ7PLUS-72-2-US Flat lip for M8 or 5/16" ICC ESR 3575 PV Cable Hex Bolt clips bottom channel Call Now for more details PROJECT INFORMATION 858-935-6064 P.E.Stamped Lettersavailablebleath.us/support INITIAL DATE: 6/1/2021 DESIGNER:MZ _ ••• REV: DATE: DESIGNER: Roof•. •• . r .• Smarter PV mounting solutions from top of roof to bottom line' 10620 1 San Diego, ► REV: DATE: DESIGNER: www.roof-tech.us info@ roof-tech.us a ji .1.4 I ATTACHMENT DETAIL ATTACHMENT DETAIL FOR SHINGLE ROOF PV_3 ■ ALLOWABLE LOAD /ATTACHMENT 5/16" LAG SCREW W/ 3.00" EMBEDMENT INTO RAFTER CERTIFICATION OF WIND ILOAD PRESSURE CAILCUILATION THIS IS A 2-RAlt DESIGN BELOW ACCORDING TO THE NATIONAL DESIGN SPECIFICIFICATION FOR WOOD DESIGN LOAD CRITERIA. AS PER ASCE 7-16 (2.4.1) CONSTRUCTION 2015 EDITION. = W' = W X CD X CT. - PER TABLE 11.3.1 NDS FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND momentum UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. SOLAR 5/16" DIA. 4" LONG LAG W/ 3.00" EMBEDMENT INTO 2X ROOF RAFTER P (PSF) = 1xD + 1x PNET (DOWNFORCE) W' = 266LB/IN EMBEDMENT (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR P (PSF) = 0.6xD + 0.6x PNET (UPLIFT) 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ SPECIES (732)902-6224 CD = 1.6 (TABLE 2.3.2 2015 NDS) (P = TOTAL DESIGN LOAD) MOMENTUMSOLAR.COM CT = 1.0 (TABLE 10.3.4 2015 NDS) (PNET = WIND LOAD) PROFESSIONAL W' = 266LB/IN X 3.00" X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE (D = DEAD LOAD) ENGINEERING MAX ALLOWABLE UPLIFT PRESSURE WITH 60% OF ULTIMATE CAPACITY �1\111111///i PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. ��� �i� 1,276.8LBS X 0.6 = 766.08LBS �� p`•.Mq4t -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. �`� ��P�cENSF ••q ��'� STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. THIS 2-RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT ' -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH No PE86753 -THESE VALUES ARE NOT VALID FOR WET SERVICE. SNAPNRACK 2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 =_ -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2-RAIL '5 AS PER MANUFACTURERS SPECIFICATIONS. DO NOT OVER-TORQUE. DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE i�O STATE OF -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. '��F F4oR10,• BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE WIND PRESSURE PNET IS CALCULATED BY ASCE 7-16 EQ. 29.4.7, WHERE Qh IS CALCULATED BY �SiS70NA1. AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. EQ. 29.4-7 (PARAMETERS SHOWN IN THE TABLE). 01111100 WIND PRESSURE ZONE CALCULATION (ASCE FIGURE 30.4-2A, 2B) GCp ARE CHOSEN FROM FIGURE 30.3-A-1 FOR SPECIFIC ROOF TYPE AND ROOF TILT WITH Digitally signed by Mina A Makar. EFFECTIVE WIND AREA EQUALS TO 10 SQFT (INTERPOLATION MAY REQUIRED). Reason : This item has been HORIZONTAL DIMENSION A 60.9500007629394' X 10% = 6.09500007629395' electronically signed and sealed by HORIZONTAL DIMENSION B 61.7000007629394' X 10% = 6.17000007629394' ARRAY EDGE FACTOR rE = 1.5 FOR ARRAY EDGES UPLIFT PRESSURE IF ARRAY EDGE IS MORE Mina A. Makar, PE 86753, COA# THAN 10 FEET (0.5h) TO ROOF EDGES AND MORE THAN 4 FEET TO ADJACENT ARRAY OR NEXT 33404 on the Date and Time Stamp BUILDING HEIGHT 15' X 40% = 6' p ADJACENT PANEL. rE = 1.0 FOR ARRAY INTERIOR UPLIFT PRESSURE AND ALL DOWNWARD PRESSURE ZONE WIDTH 6' 0 " PRESSURE AS DEFINED IN ASCE 7- shown using a digital signature. 16 29.4.4. Printed copies of this document are 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SOLAR PANEL PRESSURE EQUALIZATION FACTOR ra = 0.8 AS PER ASCE 7-16 FIGURE 29.4-8. not considered signed and sealed SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR 3'-0" NO PANEL ARE LOCATED IN ARRAY EDGE AREA AS DEFINED BY ASCE 7-16 29.4.4. FOR and the signature must be verified WIND LOAD CALCULATIONS (ASCE 7-16 EQ. 29.4-7) THIS PROJECT. on any electronic copies VELOCITY PRESSURE Qh = 0.00256 Kz*Kzt*Kd*Ke*VA 2(LB/SQFT) (EQ. 26.10-1) 2-RAIL RACKING PLUS SOLAR SYSTEM DEAD LOAD - 05-00 SOLAR CONTRACTOR EXPOSURE B COMPONENT WEIGHT/UNIT (LB) # CAMERONCHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 Kz (VELOCITY PRESSURE EXPOSURE) 0.57 MODULES 0 37 MOMENTUM SOLAR 5728 MA]OR BLVD. SUITE 307,ORLANDO FL 32819 Kzt (TOPOGRAPHIC FACTOR) 1 INVERTERS 4.0 37 CUSTOMER INFORMATION Kd (WIND DIRECTIONALITY) 0.85 RAILS (2-RAIL) @ 1.8LB/LF. 1.8 18.0 LAURIE SEIFERT- MS78508 Ke (GROUND ELEVATION FACTOR) 1 ATTACHMENT/FLASHING 0.98 65 268 NE SOLIDA DR PORT SAINT LUCIE, FL 34983 V (WIND SPEED) 160 ARRAY TOTAL AREA (SQFT) 712 7724867082 MEAN HEIGHT 15.00 ARRAY TOTAL WEIGHT (LB) 244 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 12.58 KW TOTAL DEAD LOAD PER SF (LB/SQFT) 2.60 37 MODULES: HANWHA Q.PEAK DUO TOTAL PRESSURE AND ATTACHMENT SPACING FOR GABLE ROOF WITH 7 to 20 DEGREE TILT 37 1NVEftT RS4ENPHASE GCp p- (LB/SQFT) p+ pnet- (LB/SQFT) pnet+ ATTACHMENT SPACING (INCH) IIQ7PLUS-72-2-US ATTACHMENT LB ZONE UPLIFT DOWNWARD ARRAY INTERIOR ARRAY EDGE (LB/SQFT) ARRAY INTERIOR ARRAY EDGE (LB/SQFT) ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE PROJECT INFORMATION 1 -2.00 0.30 -50.80 -76.21 7.62 -28.92 -44.16 10.22 48.00 24.00 -330.19 -252.10 INITIAL DATE: 6/1/2021 DESIGNER:MZ 2e -2.00 0.30 -50.80 -76.21 7.62 -28.92 -44.16 10.22 24.00 24.00 -165.10 -252.10 REV: DATE: DESIGNER: 2n -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 REV: DATE: DESIGNER: 2r -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 STRUCTURAL CALCULATION 3e -3.00 0.30 -76.21 -114.31 7.62 -44.16 -67.02 10.22 24.00 24.00 -252.10 -382.60 PV_3 6 3r -3.60 0.30 -91.45 -137.17 7.62 -53.31 -80.74 10.22 24.00 16.00 -304.30 -307.27 ■ SILICONE momentum PROGRESSIVE ROOFING SOLAR MA TERIALS SYSTEMS PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR pZoi 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL SS 300 Series ENGINEERING Professional Grade Silicone Sealant Technical Product Data �00 A. M /�,, 1\\ ... ....A4t BASIC USES & DESCRIPTION: g depth): �,f,CENSF .'q� B.Through cure(3/8"de th 6-12 hours ` SS 300 Series Silicone Sealant is a medium modulus silicone sealant designed for roofing applications and various joint applications. CAUTIONS & RECOMMENDATIONS: ; NO PE86753 _ SS 300 Series in neither tested nor represented as suitable for COLORS: medical or pharmaceutical uses.SS 300 Series is not ,12 a, SS 300 Series Silicone Sealant is available in 3 standard colors: recommended for silicone structural glazing,application in confined areas without proper ventilation,or joints under �0 STATE OF ► White-SS 301 constant water submersion. ���� F4ORIDP,•' ��� SS► Tan y-SS 303 LIMITED WARRANTY INFORMATION ► Lightt Gray-Gray PLEASE READ CAREFULLY: (Custom colors may be available upon request at an additional charge) The information herein is to assist customers in determining whether this product is suitable for various applications.This Digitally signed by Mina A Makar. PACKAGING: product is only intended for sale to industrial and commercial Reason : This item has been SS 300 Series Silicone Sealant is available in 10.0 fl.oz.cartridges. customers.Customers assume full responsibility for quality control,testing and determination of suitability of products for electronically signed and sealed by WEATHER RESTRICTIONS: its intended application or use.We warrant that our products will [Mina A. Makar, PE 86753, COA# SS 300 Series Silicone Sealant should not be applied when meet our written specifications.We make no other warranty of temperatures are below 20°F or above 120°F. merchantability of fitness for a particular purpose.Our total liability 33404] on the Date and Time Stamp and customers'excusive remedy for all proven claims is replacement shown using a digital signature. STORAGE AND SHELF LIFE: of nonconforming product and in no event shall we be liable for any Printed copies of this document are SS 300 Series Silicone Sealant has a recommended shelf life of other damages,including without limitation to special,incidental, 12 months from date of manufacture when stored in unopened punitive,or consequential damages. not considered signed and sealed containers and between 50°F and 80°F. Refer to product TYPICAL PROPERTIES and the signature must be verified packaging for manufacture date. on any electronic copies Test Properties Value Test Procedure APPLICATION: The surface must be clean,dry and free from oils and other Dynamic Joint Movement(%) t45 ASTM C-719 SOLAR CONTRACTOR contaminants.A thorough wire brushing,grinding,sandblasting or Elongation(%) 600 ASTM D-412 CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 solvent cleaning may be required to expose clean,sound,virgin Tensile Strenght(psi) 140 ASTM D-412 MOMENTUM SOLAR surface.SS 300 Series is primerless on most common,nonporous Modulus,100% 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 building substrates.Consult Progressive Materials,LLC for priming Elongation(psi) 38 ASTM D-412 CUSTOMER INFORMATION recommendations on other materials. Hardness Shore A 25 ASTM C-661 Tack-FreeTime(minutes) 60 ASTMC-679 LAURIESEIFERT- MS78508 In all cases,a sample should be tested and/or test joints should be 268 NE SOLIDA DR installed on the project to confirm suitability. Service Temperature -50 to+280 PM Range(°F) PORT SAINT LUCIE, FL 34983 TYPICAL CURE RATE: Accelerated Weathering, Pass ASTM C-793 7724867082 Cure rate at 77°F and 50%RH: 5000hrs PV SYSTEM INFORMATION A.Tack-free time:30 minutes to 1 hour VOC(g/L) <50 1 ASTM D-3960 SYSTEM SIZE (DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO Contact Progressive Materials for more detailed specifications on our roofing systems and to find a certified contractor near you. BLK-G6+ AC 340 37 INVERTERS: ENPHASE /� IQ7PLUS-72-2-US CR C ' MIAMUNTY 1L R C M A® U� FM l\���■ ROOF COATINGS MEMBER RATING COUNCIL LISTED APPROVED PROJECT INFORMATION COOLROOF � ® INITIAL DATE: 6/1/2021 DESIGNER:MZ Revision Date:February 18,2014 REV: DATE: DESIGNER: PROGRESSIVE ' REV: DATE: DESIGNER: 1 • 1 • PHONESEALANT SPECIFICATION SEALANT SPECIFICATION FOR SHINGLE ROOFS PV-3 . 7 Roofing ad Safety Data Sheets before using this product. Roofing Read Safety Data Sheets before using this product. momentum SOLAR • _ A AM, I 41offl- 501% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM DESCRIPTION: PHYSICAL PROPERTIES: PROFESSIONAL ENGINEERING KARNAK 19 Flashing Cement is a scientifically compounded composition of 1. Consistency: A smooth heavy trowel consistency which will readily spread on 01\111 I111/1i/ selected asphalts, mineral fibers, and refined solvents that are manufactured to a and adhere to vertical and horizontal surfaces without sagging. ��`��P. A. !Iq44t heavy consistency for application by trowel to provide a durable, elasticCENSF coating of excellent adhesion and high resistance to water and weathering. This 2. Character of Dried Film: Uniform, excellent adhesion to masonry, steel, cured product dries to a tough, flexible, waterproof and corrosion proof coating which concrete, shingles, asphalt roofing and a variety of other surfaces. _ No PE86753 gives excellent performance over wide ranges of temperature and weather 3. The dried film retains its flexibility and ductility so that the coating will resist =-o conditions. KARNAK 19 Flashing Cement is available in 3 consistencies: Summer, extreme variations in Q STATE OF era tempture and weather. Semi and Winter. ";O� !�4ort►oP, • 4. Has excellent resistance to flow at high temperatures when used on a 'i�Ss, USES: vertical surface. KARNAK 19 Flashing Cement is a general purpose cement for repairing leaks in shingles, concrete, metal or asphalt roofs, flashings on walls, chimneys, flues, Digitally signed by Mina A Makar. downspouts and cornices. It is excellent for sealing cracks in concrete and brick, as CAUTION: Reason : This item has been Do not use near open flame. Material is for building exterior applications only. electronically a joint filler for precast roof slabs and for general purpose use in maintenance of y signed and sealed by exposed buildings and structures. Avoid breathing solvent fumes and prolonged contact with skin. Do not take [Mina A. Makar, PE 86753, COA# internally. If swallowed, do not induce vomiting. Call a physician immediately. 33404] on the Date and Time Stamp SURFACE PREPARATION: Keep out of reach of children. Keep container covered when not in use. Do not thin. shown using a digital signature. All surfaces should be clean, dry and free from oil or grease, dust, dirt, loose paint Dispose of in an environmentally safe manner. Cover air intakes during application Printed copies of this document are or other foreign matter. Recommended application temperature is 40°F to 120°F. and while drying. not considered signed and sealed and the signature must be verified If applying at temperatures lower than 40°F, the substrate must be free of PACKAGING: on any electronic copies moisture and/or ice crystals. Available in 5 gallon, 3 gallon, 1 gallon cans and 10.1 oz. caulk tubes. -05-00 SOLAR CONTRACTOR APPLICATION: If further information is needed, contact Karnak Technical Services at CAMERON CHRISTENSEN Spread KARNAK 19 Flashing Cement to an average thickness of 1/8" 1-800-526-4236. CERTIFIED SOLAR`°NTRMENTU LICENSE"UMBER:`V°5'036 MOMENTUM SOLAR (approximately 8 gallons per square) and press tightly into joints, seams or cracks. 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 To repair large cracks, breaks and blisters: CUSTOMER INFORMATION LAURIE SEIFERT- MS78508 1. Spread KARNAK 19 Flashing Cement over the damaged area. 268 NE SOLIDA DR PORT SAINT LUCIE, FL 34983 2. Embed KARNAK Cotton, Fiberglass or Poly-Mat Membrane reinforcement. 7724867082 3. Apply another coat of KARNAK 19 Flashing Cement over the entire patch. PV SYSTEM INFORMATION SYSTEM SIZE (DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO SPECIFICATIONS: BLK-G6+ AC 340 37 INVERTERS: ENPHASE Federal Specification SS-C-153 Type I (Except Non-Asbestos) IQ7PLUS-72-2-US ASTM D-4586 Type I Class I PROJECT INFORMATION % N4MDaoE ceUNTY INITIAL DATE: 6/1/2021 DESIGNER:MZ MMIDADE COUN _ KAN&UM, ® 330 CENTRAL AVENUE, CLARK, NJ 07066 REV: DATE: DESIGNER: 330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300 • 800-526-4236 • FAX: 732-388-9422 REV: DATE: DESIGNER: 732-388-0300 • 800-526-4236• FAX: 732-388-9422 WEB: http://www.karnakcorp.com Revised 12.14.18 WEB: http://www.karnakcorp.com Revised 12.14.18 SEALANT SPECIFICATION CONT. PV-3 . 8 momentum SOLAR DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SnapNrack- 5flapHrack- PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE M.Watkins SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE M.Watkins 3096 HAMILTON BLVD,SOUTH PLAINFIELD,N3 Solar Mounting Solutia Solar Mounting Solutions (ENTUM OLAR. -6224 REVISION: REVISION: MOMENruMsoLAR.coM PART NUMBER(S): PART NUMBER(S): PROFESSIONAL 595 MARKET STREET,29TH FLOOR SAN FRANCISCO,CA 94105 USA 696 MARKET STREET,29TH FLOOR AN 1—MC.,CA 94105 USA PHONE(415)580-6900 FAX(415)580-6902 PHONE(415)580-6900•FAX(415)580-6902 ENGINEERING 242-02106 242-02106 NINT„,EDRaWI„DISCO„FIDENTIALA" REPRODULTIOWRITTEN GO SENT OF SUNRUN MUTH L- WITHOUTTHE REPRODUCTION,WRITTEN CONSENT OF SUNRUNISOUTH LLC.OD WITHOUT THE ```````"l l►►/''''' A. 41 e' . %,ICEN&F 0 No PE86753 0 STATE OF .•4 �� ' A40RIDP'•' ��?`� Si110111VAL NOMINMNIs you 11.25 PATENT # 8,539,719 12.00 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA# 33404] on the Date and Time Stamp 2 shown using a digital signature. Printed copies of this document are � = 6.00 0 not considered signed and sealed � �- 12.00 and the signature must be verified 0 on any electronic copies SOLAR CONTRACTOR 1 CAMERON CHRISTENSEN 3 CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 1.00 MOMENTUM SOLAR Karnak Application 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 1-Apply Karnak#19(2"dob) CD ® CUSTOMER INFORMATION 2- Press Firmly down on Shingles to spread Karnak #19 3.36 3.65 LAURIE SEIFERT- MS78508 4 27 1.82 268 NE SOLIDA DR 100. PORT SAINT LUCIE, FL 34983 7724867082 PARTS LIST .02 PV SYSTEM INFORMATION ITEM QTY DESCRIPTION 2.00 SYSTEM SIZE (DC): 12.58 KW 1 1 SNAPNRACK, L FOOT FLASHING, 12IN X 12IN, BLACK GALV 37 MODULES: HANWHA Q.PEAK DUO 2 1 SNAPNRACK, CONDUIT SUPPORT STANDOFF SUBASSEMBLY BLK-G6+ AC 340 37 INVERTERS: ENPHASE 3 1 SCREW, LAG, 5/16IN X 1-1/2IN, HEX, SS IQ7PLUS-72-2-US 4 1 SNAPNRACK, L FOOT BASE, MILL MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, ZINC PLATED STEEL, GALV STEEL PROJECT INFORMATION DESIGN LOAD (CBS): N/A INITIAL DATE: 6/1/2021 DESIGNER:MZ ULTIMATE LOAD (LBS): N/A REV: DATE: DESIGNER: TORQUE SPECIFICATION: N/A LB-FT REV: DATE: DESIGNER: CERTIFICATION: N/A WEIGHT (LBS): 1.11 ALL DIMENSIONS IN INCHES CONDUIT SUPPORT SPECIFICATION PV-3 . 9 ELECTRICAL SERVICE ELEVATION INTERCONNECTION DETAIL momentum .- d e -, ° b ,a e'• MINUMUM BEND SOLAR •° e" ,- - ° s RADIUS 4" ♦° - ° " - "' ° ° • • • • MSP LOCATED INSIDE HOT LINE TAPS ° • . ENCLOSURE DIMENSIONS PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR •♦ - , • . , MSP•. .d, • �---- ♦ - °' •d - °•- ♦ ♦ ' • • OF STRUCTURE LENGTH: 21.31" 3096 HAMILTO(73)90SOUTH -6 24 PLAINFIELD,NJ -d, , d ' • ad • d ,d WIDTH: 10.3" MOMENTUMSOLAR.COM . - ® • - - DEPTH: 9.06" • . . . L PROFESSIONAL d . , B d • ♦ . a I EXISTING ENGINEERING d ' - I METER a '0f#2/0 AWG SERVICE •. d, MPHASE a . . - #2/0 AWG SERVICE ����►� ���►� A. • COMBINER ; SOLAR d CONDUCTOR FROM • UTILITY METER FOR �� w Box AC °• 200AMPSERVICE �` A' NI • . - , DISCONNECT • . . --, ° CONDUCTOR FROM q . ° , , d • ' • • UNDERGROUND • g A ° � , 0 0 0 0 •Q o o _ No PE86753 _ FSEC CERTIFICATION STATEMENT: �0 STATE OF PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, �, •!°40R1Dp• ��� CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV 37 HANWHA Q.PEAK DUO BLK-G6+/AC 340 340W MODULES PAIRED WITH ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE PV SYSTEM CURRENT 55.9625 A DESIGNED AND APPROVED USING THE STANDARDS Digitally signed b Mina A Makar. 37 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA g y g y BUILDING CODE. FBC 2020 Reason : This item has been BRANCH CIRCUIT A electronically signed and sealed by 13 MICRO-INVERTERS EXISTING SQUARE D 225A [Mina A. Makar, PE 86753, COA# BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V 33404] on the Date and Time Stamp 12 MICRO-INVERTERS BRANCH CIRCUIT C a a + - MAIN BREAKER: 200A shown using a digital signature. 12 MICRO-INVERTERS - - - Printed copies of this document are - - ENPHASE 80A INE SIDE not considered signed and sealed AC COMBINER HOT TAP BOX SOLAR CIRCUIT and the signature must be verified DISCONNECTING MEANS on any electronic copies TERMINATION CAP 200A INSTALLED ON B B a ^ EATON 60A FUSIBLE GRID SOLAR CONTRACTOR END OF CABLE - - - SOLAR AC DISCONNECT CAMERON CHRISTENSEN ^ CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 I 60A I CUSTOMER INFORMATION - - - • eGNDBUS a - + - + ROOF 10A BREAKER LAURIE SEIFERT- MS78508 POWER UTILITY 268 NE SOLIDA DR INVERTERS JUNCTION (ENVOY) 60A FUSES GROUND METER PORT SAINT LUCIE, FL 34983 INSTALLED ON 1A TO 1C BOX 2A 20A BREAKER (A) 3 4 7724867082 RAIL SYSTEM 21B 20A BREAKER (B) 2C 20A BREAKER(C) PV SYSTEM INFORMATION SYSTEM SIZE (DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire BLK-G6+/AC 340 Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current (A) Size Type IQ INVERTERS: ENPHASE 7PLUS-72-2-US 1A TO 1C OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 06 AWG BARE CU 2A 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 13 1.21 1.25 19.66 08 AWG THWN-2 PROJECT INFORMATION INITIAL DATE: 6/1/2021 DESIGNER:MZ 213 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 REV: DATE: DESIGNER: 2C 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 REV: DATE: DESIGNER: 3 1" PVC 3+G 06 AWG THWN-2 75'C 65 0.96 1 62.40 37 1.21 1.25 55.96 08 AWG THWN-2 THREE LINE DIAGRAM 4 1" PVC 3 +G 06 AWG THWN-2 75*C 65 0.96 1 62.40 37 1.21 1.25 55.96 THWN-2 ��_ NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. INVERTER RATINGS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE momentum MODEL Q•PEAK DUO IQ7PLUS-72-2- WIRE RUN VmP ImP R L (FT) VD 0/0 V° WIRE SIZE BLK-G6+/AC 340 MODEL US SOLAR: BRANCH TO J-BOX 240.00 #NUM! 1.98 #NUM! #NUM! #NUM! 12 AWG MAX POWER 340W MAX OUTPUT POWER 290W PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR OPEN CIRCUIT VOLTAGE 40.66V OPEN DC VOLTAGE 60V J-BOX TO LOAD 240.00 0 1.24 50.00 0.000 0.00% 10 AWG 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ 6224 CENTER (ENTUM z LAR. MPP VOLTAGE 33.94V MOMENTUMSOLAR.COM NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC PROFESSIONAL 240.00 0 1.24 3.00 0.000 0.00% 10 AWG SHORT CIRCUIT CURRENT 10.52A MAX AC CURRENT 1.21A DISCONNECT ENGINEERING MPP CURRENT 10.02A AC DISCONNECT TO CEC INVERTER EFFICIENCY 97% 240.00 0 1.24 10.00 0.000 0.00% 10 AWG \\1 1 I 1 1►/ NUMBER OF MODULES 37 INTERCONNECTION \`�\x\ A. NI ///// NUMBER OF INVERTERS 37 VOLTAGE CONDUCTOR CONDUCTOR �� !�P ""' !4W ��i� UL1703 COMPLIANT YES MAKE MODEL RATING RANGE MAIN RANGE TAP �\�` ' _,C E N S F UL1703 COMPLIANT YES PV BREAKER THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG No PE86753 SUB PANEL # OF MODULES PER BRANCH FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG BREAKER SIZE UP TO 16 20A - �Q STATE OF 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN 15. ALL CONDUCTORS MUST BE COPPER. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE %�� '•.F40RIDP' CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED AC MODULES WILL COMPLY WITH 250.64. Ss, ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION /7'#ONAI. \0 COEFFICIENTS. NEC 250.24(C). IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46-250.120 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A Digitally signed by Mina A Makar. PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING GROUNDING ELECTRODE SYSTEM PER 250.54(D). 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY Reason : This item has been LUG USING#6 BARE COPPER WIRE OR#8 THWN-2 COPPER WIRE. WITH 705.12(A)OR 705.12(B) electronically signed and sealed by 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA [Mina A. Makar, PE 86753, COA# 3. THIS SYSTEM COMPLIES WITH NEC 2017 DC. 33404] on the Date and Time Stamp 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION INSTRUCTIONS FOR LINE TAPS shown using a digital signature. LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF Printed copies of this document are SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. FIGURE 1: ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE 1. ADJUST THE CONNECTOR NUT TO SUITABLE not considered signed and sealed COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. LOCATION and the signature must be verified 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY on any electronic copies 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C CERTAIN LENGTH OF THE FIRST INSULATED LAY SOLAR CONTRACTOR 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL FROM INSERTED END CERTIFIED SOLAR CONTRACTTORRLICENSENUMBER:CVC57036 7. INVERTER NOC NOMINAL OPEN CURRENT OBTAINED FROM 4. TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN MOMENTUM SOLAR ( ) EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 EQUIPMENT DATASHEET 110.26. SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. CUSTOMER INFORMATION 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART LAURIE SEIFERT- MS78508 LOCAL AND NATIONAL CODE REQUIREMENTS. RESISTANT PER NEC ARTICLE 300.6 (C)(1)AND ARTICLE 310.8 (D). IS CRACKED AND DROPPED DOWN 268 NE SOLIDA DR PORT SAINT LUCIE, FL 34983 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR 7724867082 INSTRUCTIONS USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). PV SYSTEM INFORMATION 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT SYSTEM SIZE (DC): 12.58 KW ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE 37 MODULES: HANWHA Q.PEAK DUO 11. PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). BLK-G6+/AC 340 37 INVERTERS: ENPHASE WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE IQ7PLUS-72-2-US ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ*WARNING - 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC ELECTRIC SHOCK HAZARD- DO NOT TOUCH TERMINALS-OR CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, EQUIVALENT. DISCONNECT. AND COMPLIES WITH 690.6-NO DC DISCONNECT AND PROJECT INFORMATION 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY ASSOCIATED DC LABELING ARE REQUIRED. INITIAL DATE: 6/1/2021 DESIGNER:MZ SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED REV: DATE: DESIGNER: SERVICE ENTRANCE. LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING REV: DATE: DESIGNER: CURRENT SHALL BE PROVIDED 690.52. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC705.12 �/ ELECTRICAL NOTES 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS �-- �__ ;y , 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO AND NOT PV SOURCE CIRCUITS. 690.6. ��� /� . SUB-CIRCUIT BRANCHES IS ACCEPTABLE. L•� TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 0 momentum o ACAUTION 1 AT EVERY SEPARATION BY 12 AC CONDUITS ENCLOSURES/WALLS/ SOLAR PARTITIONS/CEILINGS/FLOORS I.I AC SOLAR VOLTAGE OR NO MORE THAN 10' PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,NJ (732)902-6224 MOMENTUMSOLAR.COM © '• PHOTOVOLTAIC SOURCE • -- 1 COMBINER BOX 1 AT ANY COMBINER BOX PROFESSIONAL RAPID" '• . ENGINEERING �P.GEAWARNING ` �� . �,%CENSF � i © ELECTRICAL SHOCK HAZARD No PE86753 TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX - LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ' �0 STATE OF � w� ;� • � �� FLORIDP'. PHOTOVOLTAIC. . . I A WA R N I N G - ''��ss%NA1: RATED AC OUTPUT CURRENT A ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND Digitally signed by Mina A Makar. NOMINAL OPERATING 0 `V LOAD SIDES MAY BE ENERGIZED Reason : This item has been AC VOLTAGE 4 IN THE OPEN POSITION — OD AC DISCONNECT 1 OF EACH AT FUSED AC - electronically signed and sealed by ACAUTION (RAPID SHUTDOWN DISCONNECT OA © [Mina A. Makar, PE 86753, COA# 1 SWITCH,MAX 3FT COMPLETE VOLTAGE AND 334041 on the Date and Time Stamp • • • FROM SERVICE CURRENT VALUES ON POWER TO THIS SERVICE IS ; DISCONNECT) DISCONNECT LABEL - shown using a digital signature. ALSO SUPPLIED FROM ON-SITE MOMENTUM SOLAR Printed copies of this document are SOLAR GENERATION 3096B HAMILTON S. NJ 07080 not considered signed and sealed AC SYSTEM DISCONNECT • ., and the signature must be verified RAPID m®®SHUTDOWN •- on any electronic copies == - SOLAR PV SYSTEM =—= SOLAR CONTRACTOR At A =—— CAMERON CHRISTENSEN O ELECTRIC "• - --- CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 1 PV METER 1 AT PV METER SOCKET AND MOMENTUM SOLAR SOCKET ONE DIRECTORY PLACARD 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 IN I -� CUSTOMER INFORMATION AWARNING 1 AT UTILITY METER AND ONE DIRECTORY PLACARD LAURIE SEIFERT- MS78508 268 NE SOLIDA DR O 1 UTILITY METER © OD PORT SAINT LUCIE, FL 34983 DUAL POWER SUPPLY 7724867082 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PV SYSTEM INFORMATION SYSTEM SIZE (DC): 12.58 KW 37 MODULES: HANWHA Q.PEAK DUO EMERGENCY RESPONDER �dl: C' THIS I I IN �TRS40 SOLAR PV SYSTEM EQUIPPED 37 INVERTERS: • SHUTDOWN AWARNING 1 OF EACH AT BUILDING I IQ7PLUS-72-2-US TURN RAPID SHUTDOWN 1 INTERCONNECTION SWITCH TO THE"OFF" INTERCONNECTION POINT AND POSITION TO SHUT DOWN ,_, DUAL POWER SUPPLY POINT ENTIRE PVSYSTEM SECOND SOURCE IS ONE DIRECTORY PLACARD �g ,� .. ;, ��• PROJECT INFORMATION PHOTOVOLTAIC SYSTEM INITIAL DATE: 6/1/2021 DESIGNER:MZ m I uumnu:Ii.i REV: DATE: DESIGNER: AWARNING REV: DATE: DESIGNER: 1 BACKFEED PANEL EQUIPMENT LABELS OF © BACKFEED PV-4■ 2 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD,SOUTH PLAINFIELD,N3 (732)902-6224 MOMENTUMSOLAR.COM Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP PROFESSIONAL 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 ENGINEERING StudioGdesign@comcast.net June 1,2021 StudioGdesign@comcast.net June 1,2021 ```11111 111/11�'' A- Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria `�`��••' �,�CEN$F � �� Laurie Seifert Structural Design Loads per ASCE 7-16 i 268 NE SOLIDA DR Dead Loads=10 psf+2.6 psf(new solar panels)=12.6 psf No PE86753 PORT SAINT LUCIE,FL 34983 Roof Live Load=20 psf Ground Snow Load/Live Load=0 psf .Q Dear Plan Reviewer: Roof Slope=23 degrees Roof Mean Height=15 R Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project Basic Wind Speed=160 mph Exposure=B Q� ATATE PF �Q/` and I certify that the products are capable of supporting the code required loads and are suitable for this installation s LORID when installed in strict compliance with the manufacturers printed instructions. Wind Load Calculation CriteriaaZ'1 Wind Loads per ASCE 7-16,Equation 29.4-7 '��/0IVAI. Regazdin;g the solar panel array installation on the above referenced project please note that an inspection was Using an effective wind area of 10 SF,external pressure coefficient from Figure 30.3-A-I performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was ArrayInterior: Array Edge: conducted.There is adequate structural capacity for the installation of the array with the following recommendations: yDigitally signed by Mina A M a ka r. Zone 1=-37.62 psf Zone 1=-56.44 psf Reason : This item has been 1.The array will be installed on the existing roof.The roof ftaming is constructed of 2"x4"wood trusses @24"o.c. Zone 2e=-37.62 psf Zone 2e=-56.44 psf spanning 14'with a top chord length of 165"with intermediate supports at 1/2 points,making the effective longest Zone 2n=-62.71 psf Zone 2n=-94.06 psf electronically signed and sealed by span equals 67' with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf. Zone 2r=-62.71 psf Zone 2r=-94.06 psf [Mina A. Ma kar, PE 86753, COA# overall to the roof.The existing structure is sufficient to support the new loads associated with the additional weight& Zone 3e=-62.71 psf Zone 3e=-94.06 psf 33404] on the Date and Time Stamp wind resistance.No additional structural support is required for the roof structure. Zone 3r=-73.92 psf Zone 3r=-110.88 psf 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed shown using a digital signature. instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar Printed copies of this document are Per section 2.4.1,ASD combo=0.6D+0.6W: metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by not considered signed and sealed the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference summary table Array Interior: Zone 1=0.6x2.6psf+0.6x(-37.62psf)=-21.Olpsf and the signature must be verified below: Roof Type: Shingle Fastener Max Spacing(in.) Zone 2e=0.6 x 2.6 psf+0.6 x(-37.62 psf)=-21.01 psf on any electronic copies Attachment System: "snapNrack""Ultra Rail"® Zone 2n=0.6 x 2.6 psf+0.6 x(-62.71 psf)=-36.06 psfn2tp- -05-00 Please See Manufacture Specification and PV- Zone 2r=0.6 x 2.6 psf+0.6 x(-62.71 psf)=-36.06 psf Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 3.6 Zone 3e=0.6 x 2.6 psf+0.6 x(-62.71 psf)=-36.06 psf SOLAR CONTRACTOR embedment of 3"into the rafters CAMERON CHRISTENSEN Zone 3r=0.6 x 2.6 psf+0.6 x(-73.92 psf)=-42.79 psf CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Array Edge: CUSTOMER INFORMATION 5.All aspects of the installation shall comply with the Florida Administrative Code,2020 Florida Building Code- Zone 1=0.6 x 2.6 psf+0.6 x(-56.44 psf)=-32.3 psf Residential Seventh Edition,ASCE-7-16,2020 Florida Building Code-Energy Conservation,Seventh Edition,2017 Zone 2e=0.6 x 2.6 psf+0.6 x(-56.44 psf)=-32.3 psf LA U R I E S E I F E RT- M S78508 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 2n=0.6 x 2.6 psf+0.6 x(-94.06 psf)=-54.88 psf 268 NE S 0 LI DA DR law.All components used meet the criteria of the Florida Solar Energy Center. Zone 2r=0.6 x 2.6 psf+0.6 x(-94.06 psf)=-54.88 psf PORT SAINT LUCIE, FL 34983 6.Please refer to the attached structural calculations. Zone 3e=0.6 x 2.6 psf+0.6 x(-94.06 psf)=-54.88 psf 7724867082 If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. Zone 3r=0.6 x 2.6 psf+0.6 x(-110.88 psf)=-64.97 psf PV SYSTEM INFORMATION SYSTEM SIZE (DC): 12.58 KW Check Attachment to Wood Truss 37 MODULES: HANWHA Q.PEAK DUO i Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter BLK-G6+1AC 340 Please refer to design PV-3.6 and manufacturer specification for maximum allowable span. 37 INVERTERS: E N P H AS E dY IQ7PLUS-72-2-US Daniel W.Dunzik,RA.LEED-AP FL.Lic.No.AR98795 PROJECT INFORMATION INITIAL DATE: 6/1/2021 DESIGNER:MZ REV: DATE: DESIGNER: REV: DATE: DESIGNER: STRUCTURAL CERTIFICATION PV-5