Loading...
HomeMy WebLinkAboutblower door testmet Envelope Leakage Test Report (Blower Door Test) U IN B R 0 U K Residential Prescriptive, Performance or ERI Method Compliance OWN BUILDING &ENFRG TBirNG 2017 Florida Building Code, Energy Conservation, 6th Edition Builder: 14 tivVA 4; G-. Community: tisO;re., tod W,trS6e Lott Address: I Ant j At aAWa (�� Unit: f N�1rtN:StMRNPTNlI NUITHOC2a Ths building qr dwelling unit shall be tested and verified as having an air lea[cage rats of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. ------------- r�'PfwNtF4N�ANAN�� ar EftN MN:7HOD� The building pr dwelling uniC shall be tested and verified as having an'air leakage race of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH, ACH(50) specified on Form R405�2017-Energy Calc (Performance) or R40&;2017 (ERI): CFM(50) PASS I HIV Building Volume ACH(50) ❑FAIL When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. �.ethod,,for calculating.,�.uilding volume. ORetrieved from architectural plans ® Code software calculated OField measured and calculated [ Tesfiing. Testing shad be conducted in accordance with ANSIlRESNET/ICC 380 and reported at a pressure or 0.2 inche w.g, (Sq Pascals). Testing 'shall be conducted by either individuals as defined in Section 553,993(5) or'(7), Florida Statues, or individuals licensed as set forth in Section 489,105(3)(01 (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code o rciaL Testing shall be performed at an time after creation of all penetrations of the building thermal envelope. E' p ff' ' g p Y p g During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the Intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures, 3.Interior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Com an Name: �� I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according p the compliance method selected above. Signature of Tester: Printed Name of Tester: License/Certification #: r� 444Mi,44 P UNBROOK Duct Leakage Test Report GREEN BUiLUNG . ENERGY TESTING Residential Prescriptive, Performance or ER Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition