Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, M MAN J
Manual S Compliance Report Job: Stroke-10511 Oakbridg... Date: Jan 26, 2021 ICS i , I, . AC1 - MBR Liv By: E-Calcs Plus, Inc. Z1 nc E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Design Conditions Outdoor design DB: 90A'F Sensible gain: 15265 Btuh Entering coil DB: 75ffF Outdoor design WB: 77A'F Latent gain: 4662 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 19927 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L Actual airflow: 800 cfm Sensible capacity: 17257 Btuh 1131/o of load Latent capacity: 5206 Btuh 1121/o of load Total capacity: 22463 Btuh 1131/oof load SHR: 77% Design Conditions Outdoor design DB: 41 ffF Heat loss: 20030 Btuh Entering coil DB: 70ffF Indoor design DB: 70ffF Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L Actual airflow: 0 cfm Output capacity: 24000 Btuh 120% of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -52 °F Backup equipment type: Elec strip Manufacturer: Carrier Model: AFUE 100 Actual airflow: 0 cfm Output capacity: 5.0 kW 85% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 2021-Jan-31 12:33:34 Right-Suite@Universal2021 21.0.03 RSU28254 Page 1 _.ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E 2102-0513: SINGLE FAMILY HOME 2102-0514: ACCESSORY STRUCTURE Manual S Compliance Report Job: Stroke -10511Oakbridg... E_dIGS Date: Jan 26, 2021 Plus, Inc A C2 - Kit Guest By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Design Conditions Outdoor design DB: 90.4°F Sensible gain: 15952 Btuh Entering coil DB: 76.0°F Outdoor design WB: 77.4°F Latent gain: 4956 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 20908 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L Actual airflow: 800 cfm Sensible capacity: 17919 Btuh 1121/o of load Latent capacity: 5150 Btuh 104% of load Total capacity: 23069 Btuh 1101/oof load SHR: 78% Design Conditions Outdoor design DB: 41.0°F Heat loss: 16795 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524AP0300+FX4DNF025L Actual airflow: 0 cfm Output capacity: 24000 Btuh 143% of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -52 °F Backup equipment type: Elec strip Manufacturer: Carrier Model: AFUE 100 Actual airflow: 0 cfm Output capacity: 5.0 kW 102% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. wrightsoft - 2021-Jan-31 12:33:34 Right -Suite& Universal 2021 21.0.03 RSU28254 ' Page 2 AGGk ..ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Project Summary Job: Stroke - 10511 Oakbridg... E_ICS Date: Jan 26, 2021 Plus, Inc` Entire House By: E-Calcs Plus, Inc. Z1 E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 41 °F Outside db 70 °F Inside db 29 °F Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 31608 Btuh Ducts 2953 Btuh Central vent (71 cfm) 2263 Btuh Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 36825 Btuh Simplified Average 0 Heating Cooling Area (ft2) 2601 2601 Volume (ft') 25368 25368 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 135 68 Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a n/a 0 Btuh 0 °F 0 cfm 0 cfm/Btuh 0 in H2O 90 °F 75 °F 15 °F L 50 % 57 gr/lb Sensible Cooling Equipment Load Sizing Structure 26108 Btuh Ducts 3892 Btuh Central vent (71 cfm) 1202 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 31202 Btuh Latent Cooling Equipment Load Sizing Structure 3814 Btuh Ducts 3060 Btuh Central vent (71 cfm) 2744 Btuh Equipment latent load 6874 Btuh Equipment Total Load (Sen+Lat) 38077 Btuh Req. total capacity at 0.70 SHR 3.7 ton Cooling Equipment Summary Make n/a Trade n/a Cond n/a Coil n/a AHRI ref n/a Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio n/a 0 Btuh 0 Btuh 0 Btuh 0 cfm 0 cfm/Btuh 0 in H2O 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -41- wvrJgh#snf# 2021-Jan-31 12:33:34 Rig ht-Su ite(D Universal 2021 21.0.03 RSU28254 Page 1 'C;` ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Project Summary Job: Stroke - 10511 Oakbridg... -dICS Date: Jan 26, 2021 v ■ AC1 - MBR Liv By: E-Calcs Plus, Inc. Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17487 Btuh Structure 12668 Btuh Ducts 1586 Btuh Ducts 2088 Btuh Central vent (30 cfm) 956 Btuh Central vent (30 cfm) 508 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20030 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 15265 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1857 Btuh Ducts 1646 Btuh Central vent (30 cfm) 1160 Btuh Heating Cooling Outside air Area (ft2) 1501 1501 Equipment latent load 4662 Btuh Volume (ft') 15138 15138 Air changes/hour 0.30 0.15 Equipment Total Load (Sen+Lat) 19927 Btuh Equiv. AVF (cfm) 75 38 Req. total capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER Model 25HBC524AP0300 AHRI ref 204837229 Efficiency 8.5 HSPF Heating input Heating output 24000 Btuh @ 47°F Temperature rise 0 °F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacitybalance point= 36 °F Backup: Carrier AFUE 100 Input = 5 kW, Output = 17061 Btuh, 100 AFUE Make Carrier Trade CARRIER Cond 25HBC524AP0300 Coil FX4DNF025L AHRI ref 204837229 Efficiency 12.5 EER, 15 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i+F wwrlgh#snf# 2021-Jan-31 12:33:34 Rig ht-Su ite(D U niv ersal 20 21 21.0.03 RSU28254 Page 'C;` ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Project Summary Job: Stroke - 10511 Oakbridg... -dICS Date: Jan 26, 2021 v ■ A C2 - Kit Guest By: E-Calcs Plus, Inc. Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14121 Btuh Structure 13452 Btuh Ducts 1367 Btuh Ducts 1806 Btuh Central vent (41 cfm) 1307 Btuh Central vent (41 cfm) 694 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16795 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 15952 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1957 Btuh Ducts 1415 Btuh Central vent (41 cfm) 1584 Btuh Heating Cooling Outside air Area (ft2) 1100 1100 Equipment latent load 4956 Btuh Volume (ft') 10230 10230 Air changes/hour 0.35 0.18 Equipment Total Load (Sen+Lat) 20908 Btuh Equiv. AVF (cfm) 60 30 Req. total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER Model 25HBC524AP0300 AHRI ref 204837229 Efficiency 8.5 HSPF Heating input Heating output 24000 Btuh @ 47°F Temperature rise 0 °F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacitybalance point= 32 °F Backup: Carrier AFUE 100 Input = 5 kW, Output = 17061 Btuh, 100 AFUE Make Carrier Trade CARRIER Cond 25HBC524AP0300 Coil FX4DNF025L AHRI ref 204837229 Efficiency 12.5 EER, 15 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i+F wwrlgh#snf# 2021-Jan-31 12:33:34 Rig ht-Su ite(D U niv ersal 20 21 21.0.03 RSU28254 Page 'C;` ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Load Short Form Job: Stroke - 10511 Oakbridg... y ■ E-CaIGS Date: Jan 26, 2021 ` Plus, Inc.Entire House By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Htg Clg Outside db (°F) 41 90 Method Inside db (°F) 70 75 Construction quality Design TD (°F) 29 15 Fireplaces Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 24 57 HEATING EQUIPMENT Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency n/a Heating input Heating output 0 Btuh Temperature rise 0 °F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Space thermostat n/a Infiltration Simplified Average 0 COOLING EQUIPMENT Make n/a Trade n/a Cond n/a Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) AC1 - MBR Liv d 1501 19073 14757 0 800 AC2 - Kit Guest d 1100 15488 15258 0 800 Entire House d 2601 34562 30001 0 1600 Other equip loads 2263 1202 Equip. @ 1.00 RSM 31202 Latent cooling 6874 AInn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wF—ightsoft, 2021-Jan-31 12:33:34 Right-Suite(D Universal 2021 21.0.03 RSU28254 Page 1 + ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Load Short Form Job: Stroke - 10511 Oakbridg... ZIPlus,inc. E-CaIGS Date: Jan 26, 2021AC1 - MBR Liv By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Htg Clg Infiltration Outside db (°F) 41 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 29 15 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 24 57 HEATING EQUIPMENT Make Carrier Trade CARRIER Model 25HBC524AP0300 AHRI ref 204837229 Efficiency 8.5 HSPF Heating input Heating output 24000 Btuh @ 47°F Temperature rise 0 °F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point= 36 °F Backup: Carrier AFUE 100 Input = 5 kW nutnut = 17nfi1 Rfith 1nO ARJF COOLING EQUIPMENT Make Carrier Trade CARRIER Cond 25HBC524AP0300 Coil FX4DNF025L AHRI ref 204837229 Efficiency 12.5 EER, 15 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M BR 370 4038 3527 0 191 His WIC 49 775 306 0 17 Her WIC 49 88 250 0 14 M BA 198 3973 2476 0 134 Pool BA 49 2024 725 0 39 �.. - .y I-- w„- I — Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wF—ightsoft, 2021-Jan-31 12:33:34 Right-Suite(D Universal 2021 21.0.03 RSU28254 Page + ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E AC1 - MBR Liv d 1501 19073 14757 0 800 Other equip loads 956 508 Equip. @ 1.00 RSM 15265 Latent cooling 4662 TrNTA I o I n cnn I nnnon I n nnn� I n I onn V I /1LJ I JU 1 GUUJU 1 OU4 / U UUU Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriht5i<#` . Right -Suited Universal 2021 21.0.03 RSU28254 + ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E 2021-Jan-31 12:33:34 Page 3 Load Short Form Job: Stroke - 10511 Oakbridg... ZIPlus,inc. E-CaIGS Date: Jan 26, 2021A C2 - Kit Guest By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Htg Clg Infiltration Outside db (°F) 41 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 29 15 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 24 57 HEATING EQUIPMENT Make Carrier Trade CARRIER Model 25HBC524AP0300 AHRI ref 204837229 Efficiency 8.5 HSPF Heating input Heating output 24000 Btuh @ 47°F Temperature rise 0 °F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point= 32 °F Backup: Carrier AFUE 100 Input = 5 kW nutnut = 17nfi1 Rfith 1nO ARJF COOLING EQUIPMENT Make Carrier Trade CARRIER Cond 25HBC524AP0300 Coil FX4DNF025L AHRI ref 204837229 Efficiency 12.5 EER, 15 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.76 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Laundry 77 1789 1253 0 66 BR3 217 2235 2178 0 114 BA2 84 1252 1122 0 59 Office 165 4200 2778 0 146 BR2 213 3481 2565 0 134 Hall 48 0 0 0 0 Ha112 v1_1_- 36 - 0 n- 0 rn r_ n 0 n 0 -4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wF—ightsoft, 2021-Jan-31 12:33:34 Right-Suite(D Universal 2021 21.0.03 RSU28254 Page + ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E AC2 - Kit Guest d 1100 15488 15258 0 800 Other equip loads 1307 694 Equip. @ 1.00 RSM 15952 Latent cooling 4956 T/ I n 1 A Ann I A 11— 1 -l1/1[f I n I !f!1!1 V I /1LJ I I UU I U r UJ LUvUU U UUU Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriht5i<#` . Right -Suited Universal 2021 21.0.03 RSU28254 + ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E 2021-Jan-31 12:33:34 Page 5 Job M Stroke - 10511 Oakbridge Ct Performed by E-Calcs Plus, Inc. for: Stroke - 10511 Oakbridge Ct 10511 Oakbridge Ct Fort Pierce, FL 34951 First Floor E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8 Estero, FL 33928 Phone: 239.810.6106 www.ecalcsplus.com eric@ecalcsplus.com Scale: 1 : 115 Page 1 Right -Suite@ Universal 2021 21.0.03 RSU28254 2021-Jan-31 12:33:59 10511 Oakbridge Ct 1.26.2021.rup Duct System Summary Job: Stroke - 10511 Oakbridg... E-Calcs Date: Jan 26, 2021 qZIPlus,inc. AC1 -MBR Liv By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.234 / 0.106 in H2O 0.145 in/100ft 0 cfm 235 ft Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.234 / 0.106 in H2O 0.145 in/100ft 800 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Her WIC C 250 0 14 0.145 4.0 OX 0 VIFx 31.8 130.0 st2 His WIC C 306 0 17 0.167 4.0 OX 0 VIFx 15.2 125.0 st1 Liv Din Entry C 3736 0 203 0.160 8.0 OX 0 VIFx 21.7 125.0 st2 Liv Din Entry -A c 3736 0 203 0.155 8.0 OX 0 VIFx 26.7 125.0 st2 M BA C 2476 0 134 0.150 7.0 OX 0 VIFx 26.4 130.0 st1 MBR c 1763 0 96 0.161 6.0 OX 0 VIFx 21.0 125.0 st1 M BR -A C 1763 0 96 0.171 6.0 OX 0 VIFx 12.3 125.0 st1 Pool BA C 725 0 39 0.153 5.0 OX 0 VIFx 28.2 125.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk SO Peak AVF 0 381 0.150 486 12.0 0 x 0 VinlFlx st2 Peak AVF 0 419 0.145 533 12.0 0 x 0 VinlFlx Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 OX 0 0 405 72.8 0.145 516 12.0 Ox 0 VIFx rb1 OX 0 0 395 72.5 0.146 503 12.0 Ox 0 VIFx wri)g11 tsoft- 2021-Jan-31 12:33:34 . . .-. Right-Suite(E)Universal 2021 21.0.03 RSU28254 Page 1 ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Duct System Summary Job: Stroke - 10511 Oakbridg... ZIPlus,inc. E-CaIGS Date: Jan 26, 2021A C2 - Kit Guest By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.199 / 0.141 in H2O 0.099 in/100ft 0 cfm 344 ft Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.199 / 0.141 in H2O 0.099 in/100ft 800 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 C 1122 0 59 0.105 6.0 Ox 0 VIFx 54.5 135.0 st3 BR2 C 2565 0 134 0.104 8.0 Ox 0 VIFx 56.5 135.0 st3 BR3 c 2178 0 114 0.125 7.0 Ox 0 VIFx 29.8 130.0 st4 Kitchen c 2681 0 141 0.123 8.0 Ox 0 VIFx 32.6 130.0 st4 Kitchen -A C 2681 0 141 0.124 8.0 Ox 0 VIFx 31.2 130.0 st4 Laundry C 1253 0 66 0.118 6.0 Ox 0 VIFx 38.2 130.0 st4 Office C 2778 0 146 0.099 8.0 Ox 0 VIFx 66.5 135.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 0 339 0.099 432 12.0 0 x 0 VinlFlx st4 Peak AVF 0 461 0.118 587 12.0 0 x 0 VinlFlx 4+hl lrightsoft' 2021-Jan-31 12:33:34 I .,- , Right-Suite(D Universal2021 21.0.03 RSU28254 '"�� Page 2 ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 0 406 73.2 0.192 516 12.0 Ox 0 VIFx rb4 Ox 0 0 114 83.6 0.168 427 7.0 Ox 0 VIFx rb6 Ox 0 0 134 132.7 0.106 385 8.0 Ox 0 VIFx rt1 rb5 Ox 0 0 146 142.3 0.099 417 8.0 Ox 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 Peak AVF 0 280 0.099 514 10.0 0 x 0 VinlFlx * VrVi4a ,tsoit' �.,- Right-Suite(DUniversal 202121.0.03RSU28254 ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E 4610AraPMO IiSP NRYI Page 3 Static Pressure and Friction Rate Job: Stroke - 10511 Oakbridg... E-CcaIGS Date: Jan 26, 2021 qZIPlus,inc. AC1 - MBR Liv By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.0� Return grilles 0.03 0.0� Filter 0.1C 0.1C Humidifier 0 0 Balancing damper 0 0 Other device 0 C Available static pressure 0.34 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 20 8 Measured length of trunk 12 0 Equivalent length of fittings 130 65 Total length 162 73 Total effective length 235 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.145 OK 0.145 OK Return Ducts 0.145 OK 0.145 OK Fitting Equivalent LengthDetails Supply 4AD=60, 11A=20, 11 G=5, 11 G=5, 1A=35, 11 G=5: TotalEL=130 Return 6M=20, 5D=40, 11G=5: TotalEL=65 A-- -Pk- wri1ghtsoft- 2021-Jan-31 12:33:34 a - Right -Suite® Universal 2021 21.0.03 RSU28254 Page 1 'eM ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E Static Pressure and Friction Rate Job: Stroke - 10511 Oakbridg... ZIPlus,inc. E-Calcs Date: Jan 26, 2021A C2 - Kit Guest By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 For: Stroke - 10511 Oakbridge Ct, TE Schlitt 10511 Oakbridge Ct, Fort Pierce, FL 34951 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.0� Return grilles 0.03 0.0� Filter 0.1C 0.1C Humidifier 0 0 Balancing damper 0 0 Other device 0 C Available static pressure 0.34 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 22 15 Measured length of trunk 45 38 Equivalent length of fittings 135 90 Total length 202 142 Total effective length 344 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.099 OK 0.099 OK Return Ducts 0.099 OK 0.099 OK Fitting Equivalent LengthDetails Supply 11A=20, 4AD=60, 11G=5, 1A=35, 11G=5, 11G=5, 11G=5: TotalEL=135 Return 6M=20, 11 M=20, 11 G=5, 5D=40, 11 G=5: TotalEL=90 4+hl lrightsoft, 2021-Jan-31 12:33:34 I .,- , Right-Suite(D Universal2021 21.0.03 RSU28254 '"�� Page 2 ...ge Ct\Stroke - 10511 Oakbridge Ct 1.26.2021.rup Calc = MJ8 Front Door faces: E