HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2
Mo.
, aVz�
BCIS Home Log In i User Registration ( 'Hot Topics i Submit Surcharge 1 Stats&Facts 1 Publications ? Contact Us j BCIS Site�Map i Unks Search J
fl�rida RECEIVED
net; lai� i Product Approval
�j USER:Public User
I-:. .Y: JUN 01 2021
Product Approval Menu>Product or ADDUC360h Search>Apnlicalion List>Application Detail
I> Permitting Departl nt,
5t.Lucie CoUlly
FL# FL2569-R20
Application Type Revision
Code Version 2020 [�
Application Status Approved 0I [�
Comments F�d"�
Archived I� CODE COMPLIANCE
Product Manufacturer Soprema,Inc.(Cana T. LUCIE COUNTY
Address/Phone/Email 1640 rue Haggarty /�/
Drummondville,NON-US 00000
(819)478-2400
miamatti leu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
-
memathieu@soprema.ca
Technical Representative Mare-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext3327
me math leu @soprem a.ca
Quality Assurance Representative Jean-Francois Cate,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811 3145
jfcote@soprema.ca
Category Roofing
Subcategory :Underlayments
Compliance Method Evaluation Report from a Florida Registered'Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.'M.Nieminen
the Evaluation Report
Florida License PE-59166
Qua I ity.Assurance Entity UL.LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W,Kneievich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R20 COI 2020 01 COT NIEMINEN odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015'
ASTM D4798 2011
ASTM D6163' 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018
UL 1897 2012
Equivalence of Product Standards
Certified By
https://www.floridabuilding6org/pr/pr app_dtl.aspx?paraTn=wGEVXQwtDgsKQFEnckl31... 1/12/2021
' / t
Florida Building Code Online Page 2 of 2
Sections from the Code
Product Approval Method Method 1'OPtion D
Date Submitted 09/19/2020
Date Validated 09/22/2020
Date Pending FBC Approval 09/29/2020
Date Approved 12/15/2020
Date Revised 12/16/2020
Summary of Products
FL# Model,Number or Name Desorption
2569.1 Soprema Roof Underlayments Self adhering roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZe No FL2569,Rn 11 2020 09 37 Fii�Ai ER 170569-R20.0df
Approved for use outside HVH&Yes Verified By: Robert Nieminen,P.E.PE-59166
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-150 Evaluation Reports
Other:1.)Refer.to ER Section 5 for Limits of Use.2.)The FL2569 R�0 AE 2020 09 17 FINAL ER-FL2569-R20.odf
design pressure noted herein pertains to underlaynient Created by Independent Third Party:Yes
'systems used beneath adhesive-set the systems.Refer to ER
Section 5.6:4 for details.
Back Next
Contact Us::2601 Blair Stone Road Tallahassee K 39399 Phone:850-487.182.4
The State:of Florida Is an AA/EEO employer. .e of Florida.::Privacy Statement::.Arce5sibilit4 Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mall address released Inresponse to a public-records request,do not send electronic
mall to this entity.,Instead,contact the office by phone or by traditional mail.If you have any questions,please contact850.487.1395.-Pursuant to section 455.275
(1),Florida Statutes,effective October 1,2012,licensees ricensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
.emalls provided may be used for official communication with the licensee.However email addresses are public record:If you do not wish to supply a personal address,
please providethe Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
dick hlaL.
Product. LIREA�Ipproo"I Accepts:
l
0 lU3 —F�M
Credit Card
Safe
t
r
1
i'
f:
I
i
l
R
I
https://www.floridabuilding.6rg/pr/pr app_dtl.aspx?param-wGEVXQwtDgsKQFEnckB1... 1/12/2021
I !
I
E
i
E S I - .
March 41,2020
To whom,it may concern:
This letter is:to serve as confirmation of the following product approval for the Florida Building
Code FL17084 for low slope roofing and FL2569 for steep slope underlayments as well as the
Miami-Dade Notice of Acceptance No.: 15-1123.06.
The RESISTO Lastobond Smooth Seal, HT is manufactured by RESISTO, a division of
Soprdnia Inc.,and is privately labeled under the following other brand name:TRI-BUILT Smooth
HT S/A Underlaymenit,
Should there be any further.questions, please contact us directly.
Sincerely,
Matthew:Rucinski
Inside Sales&Technical Support
Direct: (855)227-7850
mrucinski@resistoms
1
I
J
i
t
E
i
i
i
E
f
i
IMEM ]etc.
Certificate aJAutharization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
NAWAMON'RIE-PORT-
S6prema,Inc. Evaluation.Report S18010.06.09-1118
1640 rue Haggerty FL2569-1120
Drummondville,Quebec J2C 5138 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 18::09/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida..The.documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida,Building Code. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayrnents
LABELING: Labeling'shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance.or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
Changes to the product(s),'the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a
complete review of its Evaluation.Report relative to updated Code requirements with each Code-Cycle.
ADVERTISEMENT;The Florida Product Approval Number(FL#)'preceded by the words"NEMO I etc. Evaluated"may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user.by the manufacturer
oe its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
fir„•.—«..� _..s ��•-�9:SP!'R���:
Robert J.M.Nieminen,:P.E. ' >--
r'�:`. The Facsimile seal appearing was authorized by Robert
�s;; •• Nieminen,P.E.on 09/17/2020.This does not serve as
Florida Registration No.59166,Florida DCA ANE2983 w ii.;;,p; an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
'distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interestin any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. .Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose..
©2019 NEMO ETC,LLC
�NNEmoI etc.
.ROOFING.COMPONENT EVALUATION:
e•
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments,as produced by Soprema,have demonstrated compliance with the
following sections of the VI Edition(2026)Florida Building Code through testing in accordance With the following
Standards. Compliance is subject to the Installation•Requirements and.Limitations%Conditions of Use set forth
herein.
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2012
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/11905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6168 2015
TAS]:10 Accelerated Weathering ASTM-D4798 2011
Enti Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010
.ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM 01970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/Ol/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI'04-12(MS) S43530.02.14-1-111 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
!' ERD(TST6049) ASTM D1970(QC) S44870.04:14-3 04/02/2014
ERD(TST6049). ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
:ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
t:
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO'(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 45=SOPC-18-002.o5.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW.19-SSLAP-01.A.112 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
PRI(TST5878) ASTM D1970(MS) SOP=064-02-01 12/03/2013
Soprema,Inc:(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality.Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
i
NEMO ETC,LLC Evaluation Report S18010.06.09-R38
Certificate of Authorization?l32455 7'"EDITION(2020)FBC NON-HVH2 EVALUATION FL2569-1120
Soprema Roof Underlayments Revision 18:09/17/2020
I> Page 2 of 8
ICI
;i
NEMO etc.
Product Material Plant(s) Description
Standard,
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced;SBS modified bitumen roof
underlayment
4.2 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.4 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.7 EnviroShield ASTM 01970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.9 Lastobond Eaves ASTM 01970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.1O Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforeed,,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.11 LastobondSmooth Se'al;. ASTM D1970 Gulfport'M5 self adhering glass=mat reinforced;film
}iT Wadsworth,OH ,surfaced,SBS modified bitumen roof
underlayment;
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
li underlayment
4.13 RESISTO 1131236 ASTM D1970 Drummondville,QC self adhering glass=mat reinforced;sand
Gulfport,,.MS surfaced,SBS modified b6mer_roof,
Wadsworth,OH underlayment
4.14 PrimeSource Grip-Rite ASTM 01970 Drummondville,QC self-adhering,glass=mat reinforced,sand-
Gulfport,Eave 8i Valley Protector MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.15 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
NEMO ETC,LLC Evaluation Report S18010.06.09-R18
Certificate ojAuthorization#32455 77 EDITION J( 020)FBC-NON-HVHZ EVALUATION FL2569-1120 j
Soprema Roof Underlayments Revision 18:09/17/2020
Page 3'of 8
i
� s
i
RIEf1 o etc.
Product Material. Plant(s) Description
Standard
4.17 Colphene FR GR ASTIVI D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworih,OH surfaced,SBS modified bitumen roof
underlayment
a
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in anyway,the Designer
of Record for any project on which this.Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use.ih FBC High Velocity Hurricane Zone jurisdictions.(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification:- Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile Slate or
Asphalt (1507.3) Metal ypa wood
Underlayment' Shingles Slate-Type
Mechanical Adhesive- Panels Shingles Shingles Shingles(1507.2) g Shakes(1507.9)
Attach Set (1507.4) (1507.5) (1507.7) (1507.8)
Lastobond TU HT Yes Yes Yes Yes Yes Yes Yes Yes
See5.6.1 (joint strips,1507.1.13 polnt strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Lastobond Shield/Pro HT-N Yes Yes
/RESISTO SA SMOOTH PLY Yes No No No No Yes
(joint Strips;35D7.1.1.3 (join[strips,1507.1.13
40 /R905.1-13) /R905.1.1.3)
Lastobond Shield HT/Pro Yes Yes
HT-S Yes No No Yes Yes Yes (joint strips,1507.1.13 polnt strips,1507.1.1.3.
/R905.1.1.3) /R905.1.13)
Yes Yes
EnviroShield Yes No No Yes Yes Yes (joint strips,1507.1.33 (jointstrips,1507.1.1.3
/R905.1.1.3) /R905.1.1.33
Lastobond Eaves Protection Yes Yes
Sheet/Lastobond 195 Yes No No No No Yes (joint strips,1507.1.1.3 (joint.strips,1507.1.13
_ /R905.1.1.3) /R905.1.1.3)
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&
Yes Yes
Valley Protector/TopShield Yes No No No No Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
ICE&WATER DEFENDER/ /R905.1.13) /R905.1.3.3)
RESISTO LB1244
Lastobond Smooth Seal HT/ Yes Yes
Grip-Rite Smooth Seal HT Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
Colphene FR GR Yes Yes No 'No No Yes_ point strips,1507.1.13 (joint strips,1507.1.13
/R905A.1.3) /R905.I.L3)
NEMO ETC,LLC Evaluation Report S38010.06.09-R18
Certificate of Authorization#32455 7t"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569•R20-
Soprema Roof Underlayments Revision 18:09/17/2020
Page 4 of 8
t
t�Enc .l etco
UN,
5.6.1. Adhesive-set tile is limited to use of the.following`Approved underlayment/tile-adhesive combinations..
TABLE 1A:ALLOWABLE TILE ADHESIVE'/'UNDERLAYMENT,CONIBINATIONSl
Underlayment . Adhesive Florida Product Approval
lastobond TU HT Dupont`Tile B.brid "Roof Tile Adhesive" FL22525
.
ICP Adhesives-and Sealants"Polyset®AH-160" FL6332
5.1 Allowable Substrates:
TABLE 2 SUBSTRATE OPTIONS FOR ADHERED UNDERLAYNIENTS
,Substrates(designed to meet wind loads for project)
Underlayment Application•
Type Primer Materials)
Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or5outhern Yellow Pine
HT-N,RESISTO SA SMOOTH PLY Deck/ D:41,Elastocol Stick, (SYP)
40,Lastobond Shield HT, sheathing Elastocol Stick Zero,
Lastobond Pro HT-S, ASTM D41 structural concrete
Env'iroShield,Lastobond TU HT, (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Lastobond Eaves Protection Insulation
Sheet,Lastobond 195,Lastobond self- Stick Zero Fiber Roof Board
ECO,RE515T0 LB1236,`.Geio-Rite adhering
Eave&Valley Protector,
TopShield ICE&WATER_ Base Sheet (Optional)Elastocol ASTM D226,Type 11 felt or Modified 5opra-
DEFENDER,RESISTO L61244; Stick Zero G
Lastobond Smooth.Seal HT or
Grip-Rite Smooth Seal HT
Deck (Optional)ASTMPlywood
/ D41
sheathing
self- ASTM D41. structural concrete
C61phene FR GR adhering Insulation (Optional)Elastocol Deris Deck Prime or SECUROCK Gypsum-
Stick.Zero Fiber Roof Board
BaseSheet (Optional)Elastocol ASTM D226,Type 11 felt or Modified Sopra-
Stick Zero G
RESISTO 1_13,1236;Grip-Rite Eave. Existing sand-surfaced,glass-fiber surfaced,
self- Existing RESISTO EXTERIOR
&Valley Protector or TopShield mineral-surfaced or film-surfaced roof
ICE&WATER DEFENDER adhering Substrate PRIMER underlayment*
*Final acceptance'of any existing substrate in a reroof(tear-off).installation is at the discretion of the installer and the Authority
Having Jurisdiction: Should a.question arise as to the suitability of an existing substrate to receive RESISTO LB1236,.Grip-Rite Eave&
Valley Protector at TopShield ICE&WATER DEFENDER self-adhering underlayments,'contact RESISTO technical support.
5.7.1 Soprema recommends,priming with Elastocol Stick,Elastocol 600c,or RESISTO EXTERIOR PRIMER if the final roof
cover.is not slated for installation Within 24 hours.
5.7.2 Soprema requires tongue-and-geooVe board decking be.covered.Wiih'plywood orOSB prior to installation of the
self-adhering underlayment
i Refer to Tile Mbnufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning.Moment Resistance Performance.
MEMO ETC,LLC Evaluation ReportS18010.06.09418
Certificate o_f Authorization N32455 17H EDITION(2020)FBC NON-HVHZ EVALUATION F12569-1120
Soprema Roof Underlayments Revision 18:09/17/2020
Page 5 of 8
NE(►0 I etc,
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.9.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:.
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
M.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind.Concrete and C/ay.Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the.
critical(highest)design pressure determined in accordance.with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority-Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,self-adhered.
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
'Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,self-adhered.
#4 Maximum Design Pressure=-150.0 psf:
Deck: Min.15/32-inch APA-rated BCX plywood(maybe installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
NEMO ETC,LLC Evaluation Report S18010.06.09-1`118
Certificate of Authorization#32455 1"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1120
Soprema Roof Underlayments Revision 18:09/17/2020
Page 6 of 8
f
I
� t
I
NEM0 etc.
.5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRi
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table'1A or the"
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the,elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing.Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked With an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority"Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC•1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c,in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment shall be in accordance with the-manufacturer's installation instructions and attachment of the-
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE'LIMITATIONS
Underlayment Prepared Roof Cover, Maximum
Installation Type Exposure(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,Grip- Mechanically 30
Rite Eave&Valley Protector,TopShield ICE&WATER DEFENDER.or RESISTO LB1244 attached
Lastobond TU HT Adhesive-set tile roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically 90
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT attached
Mechanically
Lastobond TU HT or Colphene FR GR attached no
5:10 Tile Slippage Limitations: When loading roof tiles On the underlayment in direct-deck file roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens'during
loading of the roof tiles.
TABLE 4:TILE SLIPPAGE"LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat "Max.10-tile stack" 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack.(bottom 2-tile-stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT
'Lugged
NEMO'ETC,LLC Evaluation Report S18010.06.09-1118
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Undedayments Revision 18:09/17/2020
Page 7 of 8
i
i
t
ALI
WN)
TABLE 4: TILE SLIPPAGE LIMITATIONS.FOR DIRECT=DECK.TILE°INSTALLATIONS,;
Underlayment Tile Profile q Staging Method Maximum Slope
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
e
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below..
6.2 Re-fasten any loose decking panels, and check for.protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236, Grip-Rite Eave &Valley Protector or TopShield ICE & WATER DEFENDER self-
adhering underlayment in a reroof(tear-off) application atop an existing underlayment (per Table 2) requires
priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a
reroof(tear-.off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip-Rite Eave &Valley
Protector orTopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6:3 Lastobond TU HT Iastobond Shield,Lastob6nd,Pr6'HT,N,-RESISTO SA.SMOOTH PLY'40,Lastobond Shield HT,
Lastobond Pro HT7S,;Enviro5hield/Last6bond:Eaves,P'rotection Sheet,Lastobond 195,Lastobond Eco,Lastobond
Smooth Seal HT,Grip-Rite Smooth Seal HT,RESISTO:LB1236,-Grip-Rite Eave&Valley Protector,TopShield ICE&
WATER DEFENDER,RESISTO LB1244or;Colphene FR,GR::
6.3.1 Non-Tile Applications:
-Shall be installed in compliance with requirements for,an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3.or FBC Residential R905.1.1.1 or R905.1:1.3 for the type of prepared roof covering
to be installed,and the.manufacturet's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications:
Limited to Lastobond TU HT or Colphene FIR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High'Wind Concrete and Clay Roof Tile Installation Manual,.Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
Refer to7.8.2 for attachment limitations.
Refer to Table 4 for the staging limitations.
' o 0
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA'entityfor manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
0
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
MEMO ETC,LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1120
Soprema Roof Underlayments Revision 18:09/17/2020
Page 8 of 8
l \`
Florida Building Code Online Page 1 of 2
77
,�i�-:.:,
6
t9✓d 4�j�. #•411 t� .
acts Home Log in User Registration ! .Hot Tophs Submit Surcharge 1 Stats&Facts Publications Contact Us 1 BCIS Site;Map i. Links .5earch j
Fforda -
' i Product Approval
71
�r�;y USER-Public User
,.-..rRECEIVED
.. uct Aoarovnl�trnu>'Product or AoalicaUon Search>Aoulication L, >Application Detail
FL# FL1654=R27
JUN ® 1 2021
Application Type Revision
node version zozo Permitting Department
St. Lucie county
Application Status Approved
Comments
Archived 0
Product Manufacturer POLYGLASS USA `Address/Phone/Email 1111 W.Newport Center Drive F cror Y✓
Deerfield Beach,FL t 2 42
(954)rt@pot gl Ext 242
malpert@potyglass.com qq1��I VV €€_, ,, F10
Authorized Signature Maury Alpert malpert@polyglass.com CODE
COMPLIANCE
Technical Representative TECH REP S YI a L g y E COUq Y
Address/Phone/Email 1111 West Newport Center Drive ., ��� /
Deerfield Beach;FL 33442 1/
(6665 802-8017
uspo I yg la sste ch�ica I @po lygla ss,co m
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
�. (888)410-1375
UspolyglasstechnicaI@polyglass.com
l-
Category Roofing
i;
Subcategory Modified Bitumen Roof System
` Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Ii Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
.the Evaluation Report
Florida License PE-59166
i Quality Assurance Entity UL LLC
Quality Assurance'Contract Expiration Date 11/07/2022
Validated By John W.Knezevich,PE
i !' Validation Checklist-Hardcopy Received
Certificate of Independence FL1654 R27 C0I.2020 QI COI NIEMINENif
it
l Referenced Standard and Year(of Standard) Standard Year
i ASTM D4601 2012
ASTM D4897 20o9
ASTM D6162 2015
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
ASTM G155 2013
FM 4470 2016
https://www.flondabuilding-org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w"/`2bn... 1/12/2021
r'
Florida Building Code Online Page 2 of 2
I
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/02/2020
Date Validated 10/64/2020
Date Pending FBC Approval 10112/2 0 2 0
Date Approved 12/15/2020
Summary of products
FL.# Model,Number or Name Description
1654.1 Polyglass Modified Bitumen"Roof SBS and APP modified bitumen roof systems
Systems
Limits of Use Installation Instructions
Approved for use In HVHZ;No FL1654'R27'II 2020 09 30 f-7NAL Ai ER PG MODBI7 FL1554-
:Approved for use outside HVHZ:Yes R27.ddf
Impact Resistant:N/A Verified By:Robert Niaminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other:'I.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete deck. EL1654 927 AE N20 2 30 FINAL ER PG MODB1T FL1654-
Refer to the ER Appendix for other systems and deck R?7.o¢f
types.2.)Refer.to ER,Section 5 for`other Limits of Use. Created by Independent Third Party:Yes
3.)Refer to FL16717 for HVHZ jurisdictions,
Z1 Next
contact us::2601 Stair Stone Road.Tallahassee F 32390 Phone:850-487-1824
The State of Florida is an AA/EEO employer,enovr oht 2007-2013 State of Florida PAvacy Statement;:BSessj3i)IfY Statement::.RefunA Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request;do not send electronic
mail to this entity.Instead,contact the office by phone or by traditfenal mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455M75
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emaAs-provided may be used for efHcial communication with the licensee.However email addresses are public mcord.If do not wish to supply a Personal address,
Please Provide the Department with an email address which can be made a.Jallable to the public.To determine if you area you licensee under Chapter 455,F.S.,please
click her..
Product App,;roov�val Acceptst
FEE El
'Credit Card
Safe
r nlima
https://www.floridabu lding.org/pr/pr app_dti.aspx?pazam=wGEVXQwtDgvgqu2w`/o2bn... 1/12/2621
i.
*NEMOlPtC.
TABLE DECK-? APPUCATION TYPE DESCRIPTION "" - PAGE
IA Wood New or Reroof(Tear-0ff) A-1 Bonded Insulation,Bonded Roof Cover 5
1B" Wood New or Reroof(Tear-Off) A-2 Mach.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-12
SC Wood New,Reroof(Tear-Off)or Recover A-2. Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 12-14
' SD Wood New,Reroof(Tear-Off)or Recover B-1 Mach.Attached Base Insulation,Sanded Top Insulation,Bonded Roof Cover 14-15
IE- Wood - New,Reroof tTear-Off)or Recover C-1 Mech,Attached Insulation;Bonded Roof Cover 15-19
1F Wood New.Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19-23
1G Wood New or Reroof(Tear-Off) E-2 Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 23-29
Vi Wood New,Reroof(Tear-Oft)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 29-36
II -Wood New ar�Re oof(Tear-Off)--' .f _ :NominsuIated;Borded RhdfCover— 37-
2A Steel-or Structural concrete New,Reroof(Tear-0ff)or Recover B-1 Mech.Attached Base Insulation;Bonded Top Insulation,Banded Roof Cover 33-43
2B Steel or Structural concrete New,Remof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 44-50
2C Steel or Structural concrete New,Reroof(roar-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover, 51-53
2D Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Velociflex,Bonded Roof Cover 53-55
3A Structural concrete New or Reroof(Tear-Off) A-1 Banded Insulation;Bonded Roof Cover 56-68
38 structural concrete New ar Reroof(Tear-Off) F Non-Insulated,Bonded.Roof Cover
4A lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 69.73
4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor,Sheet,Bonded Insulation,Bonded Roof Cover 73.47
4C Ughtweight concrete New or Reroof(Tear-Off) E-2 Non-Insulated,Mach.Attached Base Sheet,Bonded Roof Cover 74-78.
SA Cementitious wood fiber Reroof(Tear-OR) A-1 Bonded Insulation;Banded Roof Cover 79-80
5B Cementitious wood fitter Reroof(Tear-Off)or Recover A-2 Niech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 80.82'
SC Cementitious wood fiber Reroof(Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,-Bonded Roof Cover 82
5D Cementitious wood fiber Reroof(Tear-Off)ar Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 83
r SE Cementitious wood fiber Reroof(Tear-Off)or Recover E-2 Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 83
6A Existing gypsum Reroof(Tear-Off) .A-1 'Bonded Insulation,Bonded Roof Cover .84.88
6B Existing gypsum Reroof(fear-Off)or Recover A-2 Mech,Attached Anchor Sheet,Bonded Insulation,Bonded.Roof Cover 88
6C Existing gypsum Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover .88
6D Existing gypsum Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech:Attached Base Sheet,Bonded Roof Cover' 88
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 89-94
78 Various Recover F Non-Insulated,Bonded Roof Cover 94
NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL16S4-R27
Certificate of Authorization#32455 711 EDITION(2020)FBCNON-HVHZ EVALUATION Revision 25:09/30/2020
02018 NEMO ETC,LLC Polyeass Modffled Bitumen Roof Systems;(954)2.33-1330 Appendix I'Page 1 of 94
NNEMO e$C.
MEMBRANE ADHESIVE COMBINATIONS.
REFERENCE LAYER MATERIAL _ APPLICATION
SOS-SA-H Base Ply Elastobase SA Self-adhering (followed
(ses.sa6aane.;nz Hr6ns sYswm,) _ by torch-applied sheet)
:Base Ply- One or more plies Elastoflex.SAM,Elastoflex SA V FR Elastoflex$A V Plus,Elastoflex SA V Plus FR,Elastoflex SA Base HD
SBS•SA •.Cap Ply: 'Elastoflex SXP.,Etwoflex SA P FR,PolyreFlect
(SBS,S.If-Adhering) Note: Unless otherwise noted,permissible membrane substmtesjorSBS-SAorelimited to the SBSSA Bose plyoprions herein, Self-Adhering
Elastobase poly/sand or Efostobase(poly/pol).
APP-CA1 Cap Ply PolyRex G FR PG350 at 1.5-2.0
jai/square
APP-TA Base Ply or Ply One or more plies Polyglass Base Polyflex,Pol bond
(APP,Torch-Applied) Cap PIy Pal lax,Polyflex G,Polyflex G FR,Polybond,Pol bond G,Polyf asko G,Polyfresko G FR Torch-Applied
APP-SA-H Base Ply" Polyflex$A Base Self-adhering(followed
(APP,s.8-aerer�n&xrerw smams) by.torch-applied sheet)
APP-SA Cap PIy Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polyfresko G SA FR,Polykool
(APP,Self-Adhering) Note:' Unless otherwise noted,permissible membrane substratesforAPP-SA are lim;tedto the SBS-SA Base Ply options herein, Self-Adhering
Eiastobose(poly/sand)or Elastabose(oJ/polyj.
16 Vapor barrier options for use over structural concrete deck followed by bonded insulatlon carry the following MOP limitations.The lesser of the MOP listings below vs.those in Table 3A applies,
VAPOR BARRIER OPTioNs;STRUCruRAL CONCRETE DECK;FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: "
'OPTION VAPOR BARRIER
PRIMER MOP
N -TYPE NOTE 15 INSULATIONADHESIVE .MOP
( ) APPLICATION
C-V&1. PGS00 Elastoflex SA V Plus Self-Adhering D-IS or CR-20,12-inch o.c. -60,0
C-VB-2. PGSOO - Polyglass Base Torch-applied D-IS or CR-20,12•inch o.c. -75.0
C-VB-3. . .PG1D0 Elastoflex SAP Self-Adhering D-IS,12-inch'o.c. -75.0
C-VB-4. PG100 Elastoflex SAP Self-Adhering M-OSFA,12-inch o.c. -257.5
C-VB-5. PG100 Elastoflex SAP Self-Adhering CR-20,124nch o.c. -270.0
C-VB-6. PG100 Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR Self-Adhering M-OSFA,M-PG•1,OB500 or CR-20,12-Inch
C-VB-7. PG100 SBS-TA(with sanded-top-surface) Torch-applied M-OSFA,M-PG-1,OB500 or CR-20,12-inch
17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance.Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings
for application limitations and a Roofing Materials Directory for fire ratfngs associated with coating usage.
.SURFACING OPTIONS FOR POLYGIATS MODIFIED BITUMEN ROOF SYSTEMS
OPTION SURFACING FLORIDA PRODUCTAPPROVAL
5URF-1. PG 300 FL10291
SURF-2. PG 600 FL10291
SURF-3. PG 650 FL10291
SURF-4. PG 700 FL10291
SURF-S. PG 700 QS - FL10291
SURF-6. PG 800 FL10291
SURF-7. I Polyplus6D FL10291
NEMO ETC,LLC Evaluation Report P9290.02.08-R25 for FL1654-R27
Certificate of Authoriutfon tt32455 7T1 EDITION(2020)FBC NON-HVHZ EVAUJATION Revision 25:09/30/2020
CD2018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;1954)Z33.1330 Appendix 1,Page 4 of 94
i
f`
t
NNEMOJeM
TABLE 11,
:oat. 0 • -.. ,.
• r :s r r••s
.System Deck(Note I) ,Primer Roof Cover(Note 151
MDP(psfj
No. Joint Treatment Base Ply Ply Cap Ply
Sur-ADHERINGBASEPLY
APA rated, Elastoflex SAVPius
7/16 CAT, None OSB joints are covered with 4-inch wide strips of Elastoflex SA V,rolled Into (Optional(SBS-SA,SBS- SBS-SA,APP-SA, -52.5.
0.418 in.,. place to create continuous bond. or Elastoflex SA V
W 208
Plus FR TA,APP TA SBS-TA,APP-TA
Exposure 1 OSS
Man.15 Jr.- .?(Optic�a(1 0S-5A;585 SBSSA,
-W-209 �pywood.. None.' %None:, `Sf35SA
:.inch .:.:-, `APPTA 385-TA,APPTA
.
W-210 Min.15/32- P6100- None SBS-SA (optionai)SSS-SA,SBS- $BS-SA,APP-SA, -97.5
Inch plywood TA,APP-TA SBS TA,APP-TA
Min.15/32- Plywood joints are covered with 4+Inch wide strips of Elastoflex SA V Plus,rolled Elastoflex SA V or (Optional)SBS-SA,SBS- SBS-SA,APP-SA, 97 5
W-211 (Optional)PG300
inch plywood Into place to create continuous bond. Elastoflex SA V FR. .TA,APP TA SBS-TA,APP-TA
Min.15/32-- POLYBRITE 745 (Optional)SSS-SA,SBS- SBS-SA,APP=SA, -105.0
W-212 Inch plywood or WB3000, None SBS-SA .TA,APP-TA 585-TA,APP TA
Elastoflex$A V.Plus
-Min.15/32- Plywood Joints are covered with 4-inch wide strips of ElastoflexYAV Plus,rolled :(Optional)SBS-SA,SBS- SBS-SA,APP-SA,
W-213 ,Inch plywood (Optional)PG300" into place to c reate continuous bond. or Elastoflex SA V TA,APP-TA SBSTA;APP-TA -135.0
Plus FR
HYBRIDSYSTEWNIT1 SELF-AV]MRINGAPP BASEPLY: - - - -
W-214 Min,15/32- (O'ptlonat)PG100 None )
APP-SA-H (optional)ADD-TA APPTA -90.0
inch plywood
W-215 Min.15/32- (Optional)PG100 Plywood joints are covered with 44nch wide strips of Elastoflex SA V Plus,rolled APP.SA-H (Optional)APP-TA APP TA -135.0
Inch plywood Into place to create continuous bond.
'HY6RID SYSTEMS WITH SEtF-AOHEt<IN6565 BASE P.IY:. "'• ' � � •-
W-216 Min:15/32- None None SBS-SA-H (Optional)SBS-TA SBS-TA -90:0
Inch Plywood
Min,J5/32- O SBSTA 5B5 TA
W-217 inch plywood PG100 None SBS-SA-H. (Optional))
W-218 Min'15/32• (Optional)PG300 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled SBS-SA-H (Optional)SBSTA SBS-TA -97.5
Inch Plywood into place to create continuous bond,
W-219 Min.15/32- POLYBRITE 745 None SBSSA-H (Optional)SBSTA SBS-TA -105.0
Inch plywood or W63000
MEMO ETC,LLC _ Evaluation Report P9290.02.08-R25 for FL1654-R27
Certficate of Authoritation h3245S 7a'EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/30/2020
02018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233.1330 Appendix 1,Page 37 of 94