HomeMy WebLinkAboutProject Information WINDOW& ®O• - OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + PSF + PSF TESTED MULLION
( ) (-)PSF ( ) (-)PSF SIZE DIMENSIONS REQ Y/N/NA REQ Y/N
1 End Window 7i8"Lami 20-1103.09 55 55 35.4 -45.7 74 x 63 72x54 No No
2 End Window 7i8"Lami 20-1103.08 55 55 36.2 -47.4 53 x 77 51x54 No No
3 Int Window 7/8"Lami 20-1103.08 55 55 36.2 -39.4 53 x 77 51x54 No No
4 End Window 7/8"Lami 20-1103.08 55 55 36.2 -47.4 53 x 77 51x54 No No
RECEI D
Permittli ig
*We
0