HomeMy WebLinkAboutEvaluation Report; Soprema Roof UnderlaymentsC RECEIVED D 3 y. 2 BSA v� oe - MAY V9 1011 ' REV ��,r� � IVEnno I etc. L(11 V ld �PerrJlG[InDep rC�tr Certificate of Authorization #32455 CODE r S� I-uc�e��RtkC[E353 Christian Street, Unit#13 U [P' Oxford, Cr 06478 510ve�"� S7o LUME COUNTry (203) 262-9245 ENGINEER EVALUATE B(D( (T(E ST CONSULT Soprema, Inc. 1640 rue Haggerty Drummondville, Quebec J2C 5P8 Canada (819) 478-2400 W Evaluation Report S18010.06.09-1118 FL2569-R20 Date of Issuance: 06/15/2009 Revision 18: 09/17/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use ,of construction materials in the State of Florida. The documentation s—i 'Fn reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the'Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 SQL .: - -e .�-• % 4 �.. g•r�• r. �•: 'so,� ,,_.� zo�,-,.�• The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/17/2020. This does not serve as `y�r..•r"'�, an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ONEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2012 1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2 / R905.11.2 Material standard ASTM D6163 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 Ent) Examination Reference Date ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) ASTM D1970 / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010 ERD (TST6049) FRSA/TRI 04-12 (OH) S11150.05.09-112 10/05/2010 ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 (MS) S37210.12.11 12/01/2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (BC) S44870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC34045.05.17-R1 06/07/2017 M-D (CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES (EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 MEMO (TST6049) ASTM D1970 /TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 MEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. 1127605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 NEMO ETC, LLC Certificate ofAuthorizatlon #32455 1' EDITION (2020) FBC NON-HVHZ EVALUATION Soprema Roof Underlayments Evaluation Report S18010.06.09-R18 FL2569-R20 Revision 18: 09/17/2020 Page 2 of 8 ONEMOjet 4. PRODUCT DESCRIPTION: 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 ProductMaterial Plant(s) Description Sttandardandard Lastobond TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene -surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Protection Sheet Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment Lasto I Zb7admoot Sea ASTM D1970 Gu ort M sel a erm ass mat rein orce , m- Wadsworth, OH rs—u ruamed 10506770if 0115 RM—e—REFao [1n eP a 2 t PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Smooth Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment RESt5T0 L8S2 ASTM D1970 Drummondville, QC se a erin ass mat r n ores , san - (Gu port, MisuffR.T, SB mo i ie 1. . en ro. Wadsworth, OH a era me t PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand- Eave & Valley Protector Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment SRS TopShield ICE & ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - WATER DEFENDER Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment MEMO ETC, LLC Evaluation Report S18010.06.09-R38 Certificate ofAuthorization #32455 7" EDITION (2020) FBC NON-HVH2 EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 28: 09/17/2020 Page 3 of 8 4.17 ONEMOletc. Product Material Plant(s) Description Standard Colphene FR GR ASTM D6163 Gulfport, MS self -adhering, fiberglass reinforced, granule - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE is ROOF COVER OPTIONS Asphalt... Clay and Concrete Tile - Metal Slate or Wood- - " (1507.3) Slate -Type Underlayment Shingles Shingles Mechanical Adhesive- Panels Shingles Shingles (1507.2) Attach Set (1507.4) (1507.5) (1507.7) (3507.8) Shakes (1507.9) Yes Yes Yes Lastobond TU HT Yes Yes See 5.6.1 Yes Yes Yes Qoint strips, 1507.1.13 (Joint strlps,1507.1.1.3 / R905.1.1.31 / 119D5.1.1.3) Lastobond Shield / Pro HT-N Yes Yes / RESISTO SA SMOOTH PLY Yes No No No No Yes Uoint strips, 1507.1.1.3 (joint strips,1507.1.13 40 / R905.1.1.3) / R905.1.1.31 Lastobond Shield HT/ Pro Yes Yes HT-S Yes No No Yes Yes Yes (joint strips, 1507.1.1.3 GoInt strips,1507.1.1.3 / R905.1.13) / R905.1.1.3) Yes Yes EnviroShield Yes No No Yes Yes Yes (joint strips, 1507.1.1.3 Qoint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) Lastobond Eaves Protection Yes Yes Sheet / Lastobond 195 Yes No No No No Yes Uoint strips,15o7.1.1.3 Uoint strips, ls07.1.1.3 / R905.1.1.3) / R905.1.1.3) Lastobond ECO / RESISTO LB3236, Grip -Rite Eave & Yes Yes Valley Protector / TopShield Yes No No No No Yes Uoint strips, 1507.1.1.3 Uoint strips, 1so7.1.1.3 ICE & WATER DEFENDER / / R905.1.1.3) / R905.1.1.3) RESISTO LB1244 Lastobond Smooth Seal HT/ Yes Yes Grip -Rite Smooth Seal HT Yes No No Yes Yes Yes Uoint strips, 1507.1.1.3 Uoint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) Yes Yes Colphene FR GR Yes Yes No No No Yes Goint strips, 1507.1.1.3 Uoint strips, 1507.1.1.3 / R905.1.1.3) / 11905.1.1.3) NEMO ETC, LLC Evaluation Report S18010.06.09-R18 Certificate of Authorization N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 4 of 8 ONEMOjetc. 5.6.1 Adhesive -set the is limited to use of the following Approved underlayment / tile -adhesive combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive . Florida Product Approval Lastobond TU HT Dupont "Tile BondTM Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" FL6332 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Lastobond Shield, Lastobond Pro (Optional) ASTM plywood, OSB or Southern Yellow Pine HT-N, RESISTO SA SMOOTH PLY Deck / D41, Elastocol Stick, (SYP) 40, Lastobond Shield HT, sheathing Elastocol Stick Zero Lastobond Pro HT-S, ASTM D41 structural concrete EnviroShield, Lastobond TU HT, (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum- Lastobond Eaves Protection self- Insulation Stick Zero Fiber Roof Board Sheet, Lastobond 195, Lastobond adhering ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- DEFENDER, RESISTO LB1244, Stick Zero G Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT Deck/ (Optional)ASTM Plywood sheathing ASTM D41 structural concrete self- Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum - Colphene FR GR adhering Stick Zero Fiber Roof Board Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- Stick Zero G RESISTO LB1236, Grip -Rite Eave self- Existing EXTERIOR Existing sand -surfaced, glass -fiber surfaced, & Valley Protector or TopShield adhering substrate PRIMER PRIMER mineral -surfaced or film -surfaced roof ICE & WATER DEFENDER underlayment* * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue -and -groove board decking be covered with -plywood or OSB prior to installation of the self -adhering underlayment 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S18010.06.09-R18 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 5 of 8 ONEMOletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -45.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT, self -adhered. #3 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered. Underlayment: Lastobond TU HT, self -adhered. #4 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered. #5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report S38010.06.09-R38 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 6 of 8 ONEMOletc. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC'1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6- inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT, self -adhered 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment attachment shall be in accordance with the manufacturer's installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure (days) Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB3236, Grip- Mechanically 30 Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 attached Lastobond TU HT Adhesive -set tile roof 30 system Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY40, Lastobond Shield HT, Mechanically 90 Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT attached Lastobond TU HT or Colphene FIR GR Mechanically attached 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max.10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high on slope, as shown below) 6:12 Lastobond TU HT ', 4 i Lugged J NEMO ETC, LLC Evaluation Report S18010.06.09-R18 Certificate of Authorization #32455 7TM EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 7 of 8 ONEMOletc. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 5:12 Colphene FR GR Lugged Max. 10-tile stack 6:12 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self - adhering underlayment in a reroof (tear -off application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO L61244 or Colphene FR GR: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1S07.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3.2 Tile Applications: Limited to Lastobond TU HT or Colphene FR GR. Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. Refer to7.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report S18010.06.09-R38 Certificate ofAuthorization #32455 7- EDITION (2020) FBC NON-HVH2 EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18: 09/17/2020 Page 8 of 8