Loading...
HomeMy WebLinkAboutSoil Compaction ReportHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: CONTRACTOR: JOB LOCATION: Tl 10 1 t' ENGINEERING i117iVi AND TESTING SOIL COMPACTION REPORT ASTM D'1557 and ASTM D 6938 May 20, 2021 RECEIVED A & G Pools MAY` 2 4:'2021 7683 Pelican Pointe Drive Jensen Beach, Florida parPnitting Department gt, Lude County Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 213795-1pA/MH/ah PERMIT ,;1Q# 02. NUC # 630 Nuc Model: MC-IDR-P Nuc Serial #: 30630 ITEM TESTED : Pool Backfill Compaction TEST LOCATION PEN DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE COMPACTION 1 N.E. 0'-i' 50 108.1 108.8 99.4% 2 1'-2' it- If95.0% + 3 2'-3' " -It95.0% + 4 3'-4' " - 1195.0% + 5 N.W. 0'-1' 50 107.6 108.8 98.9% 6 1'-2' 11- " 95.0% + 7 2'-3' " -It95.0% + 8 3'-4' " - If95.0% + 9 S.W. 0'-1' 50 108.3 108.8 99.5% 10 1'-2' IT- 1195.0% + 11 2'-3' " -1195.0% + 12 3'-4' 11- If 95.0% + Soil Description: Brown Sand In Place Moisture: 5.9% Proctor Optimum Moisture: 10.0% Proctor Max. Dry Density: P.C.F. 1088 I I I I I I I I I I I I I I P Y I—i... ._..t..-11. @ Test Locations the Density & /i- Penetrometer reading indicate the 106.0 -� •Degree of Compaction Meets I Minimum Requirement F 105.0 j— J— —for Plumbed Backfill I I 1 W 110.0 - I E I I 109.0 }—..�.._ G I H 108.0 T D I I R107.0—..-I.._.I—.. RejgV(#yl`ly&bmitted: 104.0— I I I I I I I ��ypt�1 E•0'4yk, Digitally 103.0 •I— _ — •C N• / .-1.. .,_.. T. —1. _.. r.. _,. .,_..1 �Q' signed by 5 6 7 8 9 10 11 12 13 ` � Tb.inn. na.be.n.nm.ma.uvy�.a.w No. 87439 ealdbY&YanEDahhe•iEFL h81a39 Bryan E Dahlke Moisture - % of D Weight �.n mea.n.nna aoan,mx.. a0emme Dry 9 �.mtlra�dsi.mm. * * : �C-vMnamc.awm�amm.nn,.ro. Date: �^°�°d�•^•^^•°�°•^°�• Disclaimer: Contractor is responsible to maintain �o • � _�am2m�b..�..a.n.m.�.nt 2021.05.21 the pool backfill in the condition that KSM Al ,Q STATE OF Qj� 14:18:54 '••��ORIDP;••'•.�2�� completed the indicated passed compaction test. -0400 i,Fss • •....• • �(�`�� ' KSM is not responsible if the poolbackfill has been NAll. altered from the approved inspected condition. Bryan t' bahlke, P.E. V.P. of Engineering PE # 81439 5/21/2021 Email to: abirmingham@angpools.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business- WBE