Loading...
HomeMy WebLinkAboutPLAN REVIEW RECORD.2018 INTERNATIONAL Plan Review # 2103-0980 RESIDENTIAL CODE® Date: 5i5t21 FOR'ONE-,AND-TWO-FAMILY DWELLINGS Valuatioli: LA . Fee: P N REVIEW RECORD " �. St Lu ie County JURISDICTION .County,'�Towfighip etc )'y k BUILDING LOCATION y 1071`S Header Canal' Rd ' (street'adtlress) - BUIL�ING DESCRIPTION Sipgle,Family Residence 4 bedroom L34/2• bath/ 3 Car Garage '" ',REVIEWED F ;BY Numeralstndicatedxm parenthesis are applicable code sections ofthei20187ntemational Residential Cotle' IRC The lan review accom lisheiias°indicated=. G }; p P .--m this record is lurited to those code sections specificallydentified herein; This record references commonly applicable cotle sections"with due regard;for " the amount and tperof detaileda�nforma4on which is typically found onTco�struction,documents♦for one= and two-family dweljngs and,; townhouses It does'. a s. r r = not reference all code provisions>which may l e�appltcable to specrf'ic,bu'Idirrgs This iecor`dis iesigned'ito be used-only.by those:who are knowledgeable ° ': .. M and capable of exercising,competent ludgment;in evaluating consttuction documeptsafor cod e;,compliarice. r CORRECTIONS LIST Code No. DESCRIPTION Section - •• • C • ••: � '-• •e a • • • • -• ISBN 978-1-60983-802-7 \� - • • • •• e • • �IIIIIIIIIII III IIIIIIIII �� _.- ® - -•• • - 9II781609II838027II INTERNATIONAL ® ®D s CODE COUNCIL! ® ®- T022650 -1- CORRECTION LIST (cont'd.) No. DESCRIPTION Code Section -2- NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project. BUILDING PLANNING (Chapter 3) DESIGN CRITERIA [Table R301.2(1)] N/A Two-family dwelling separation (R302.3) Floor live load (Table R301.5) N/A psf N/A Dwelling unit penetrations (R302.4) Roof live load (Table R301.6) 20 psf X Dwelling/garage opening/penetration protec- Ground snow load [Figure R301.2(6)] N/A psf tion (R302.5) Ultimate design wind speed [Figure R301.2(5)A] X Dwelling/garage fire separation (R302.6) mph N/A Under -stair protection (R302.7) Wind exposure category (R301.2.1.4) C WALL AND CEILING FINISHES (R302.9) Wind design required (R301.2.1.1) 160 Seismic design category (SDC) (Figure 301.2( )J wA SDC C&D provisions (R301.2.2) N/A Weathering NEGLIGIBLE Frost line depth N/A Termite area VERY HEAVY Winter design temperature X Ice barrier underlayment required N/A Flood hazards N/A FIRE-RESISTANT CONSTRUCTION (R302) Exterior walls (R302.1; Tables R302.1(1), R302.1(2)] N/A Townhouse separation (R302.2) N/A Double walls (R302.2.1) N/A Common walls (R302.2.2) N/A Continuity (R302.2.3) N/A Parapets and construction (R302.2.4, R302.2.5) X Structural independence (R302.2.6) ROOM PLANNING REQUIREMENTS (R303 through R305) X Flame spread index (R302.9.1) X Smoke -developed index (R302.9.2) X Testing (R302.9.3, R302.9.4) INSULATION (R302.10) X Flame spread/smoke-developed (R302.10.1) N/A Loose -fill (R302.10.2) X Cellulose fiber loose -fill (R302.10.3) INSP Exposed attic insulation (R302.10.4) INSP Testing (R302.10.5) INSP Fireblocking (R302.11) INSP Draftstopping (R302.12) INSP Fire protection of floors (R302.13) INSP Combustible insulation clearance (R302.14) Use Area (ft2) Width Ceiling heights Natural light* Natural ventilation* Living 70 7'-0" 7'-0" 8% floor area 4% floor area Dining 70 7'-0" 7'-0" 8% floor area 4% floor area Kitchen N.A. N.A. 7'-0" 8% floor area 4% floor area Bedroom 70 7'-0" 7'-0" 8% floor area 4% floor area Bathroom N.A. N.A 6'-8" 3 square feet V/2 square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basements. X R lre ' d h t' R303 G 10 LAZING 0308 equea Ing ( ) SANITATION (R306, R307) X Water closet X Lavatory X Tub or shower X Kitchen area with sink X Sanitary sewer (Chapter30) N/A Private disposal (Appendix i) INSP Identification (R308.1) N/A Louvered windows or jalousies (R308.2) INSP Human impact loads/hazardous locations (17308.3, R308.4) INSP Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) INSP Floor surface (R309.1) N/A Carport (R309.2) INSP Automatic garage door opener (R309.4) N/A Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) X Where required (R310.1, R310.5, R310.6) INSP Areas, height, width, operations (R310.1.1, R316.2.1•, R31 a2.2, R310.2.5) N/A Window and area wells (R310.2.3, R310.3.2) N/A Under decks and porches (R310.2.4) X Doors (R310.3) N/A Bars, grilles, covers and screens (R310.4) MEANS OF EGRESS (R311) X General (R311.1) X Egress door (R311.2) X Landings at exterior doors (R311.3, R311.3.1 - R311.3.3) N/A Vertical egress (R311.4) INSP Construction'and attachment (17311.5) X Hallways (R311.6) N/A Stairway width, headroom, vertical rise, walk - line (R311.7.1 - R311.7.4) X Stairway treads, risers, nosings, plastic com- posite (R311.7.5.1 - R311.75.4) X Stairway landings and walking surfaces (R311.7.6, R311.7.7) X Handrails required (R311.7.8) X Handrail details (R311.7.8.1 - R311.78.6) N/A Stairway illumination (R303.7, R303.8, R311.7.9) N/A Special stairways (R311.7.10) N/A Alternating tread device (R311.7.11) N/A Ships ladders (R311.712) N/A Ramps (R311.8) GUARDS AND WINDOW PROTECTION (R312) N/A Where required (R3.12.1.1) N/A Height (R312.1.2) N/A Opening limitations (R312.1.3) N/A Window fall protection (R312.2) AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) N/A Townhouses (R313.1) N/A One- and two-family dwellings (R313.2) SMOKE ALARMS (R314) X Referenced standards (R314.1) X Location and interconnection (R314.3, R314.4) X Power source (R314.6) CARBON MONOXIDE ALARMS (R315) INSP Referenced standards (R315.1) X Location and interconnection (R315.3, R315.5) X Power source (R315.6) X Detection system (R315.7) FOAM PLASTIC (R302.8, R316) N/A Labeling (R316.2) N/A Surface burning, thermal barrier, specific requirements/approval (R316.3 - R316.6) N/A Termite damage (R316.7) N/A Wind resistance (R316.8) DECAY AND TERMITE PROTECTION (R317, R318) X Protection required (Table R301.2(1); R317.1, R318.1) INSP Quality mark (R3172, R318.1.1) SITE ADDRESS (R319) INSP Address numbers (R319.1) ACCESSIBILITY (R320) X Type B dwelling units applicable. (R320.1) ELEVATORS/PLATFORM LIFTS (R321) N/A Referenced standards (R321.1 - R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) N/A General (R322.1) N/A Hazard area and requirements (R301.2.4, R309.3, R322.2, R322.3) STORM SHELTERS (R323) N/A General/referenced standard (R323.1) SOLAR ENERGY SYSTEMS (R324) N/A System, installation, access (R324.2 - R324.7) MEZZANINES (R325) N/A Clear height, area, a ress, openness (R326..2 - R325.5 N/A Habitable attic (R325.6) SWIMMING POOLS, SPAS AND HOT TUBS (R326) N/A ISPSC (R326.1) STATIONARY STORAGE BATTERY SYSTEMS (R327) N/A Referenced standards, installation, ventilation (R327.2 - R3275) N/A Impact protection (R3276) -4- FOUNDATIONS (Chapter 4) MATERIALS.(R402) X Horizontal and vertical reinforcement size N/A and spacing (Tables R404.1.2(i) - Wood foundations (R402.1) R404.1.2(8), R404.1.3.2, R404.1.3.3.71 X Concrete (R402.2, R402.3) X Materials (R404.1.3.3) FOOTINGS (R403) X Thickness (R404.1.5.2) X Soil bearing value (R401.4, R403.1) N/A SDC D provisions (R404.1.4.1, R404.1.4.2) X Footing width, edge thickness, projection X Height above finished grade (R404.1.6) (R403.1.1, Tables R403.1(1) - R403.1(3)] N/A N/A Wood foundation walls (R404.2) Footings in SDC D X (R403.1.2, R403.1.3) Sill plate size (R404.3) N/A Depth/frost protection (R403.1.4, R403.1.4.1) N/A Retaining walls (R404.4) X Slope (R403.1.5) N/A Precast concrete foundation walls (R404.5) X Anchorage (R403.1.6) N/A Drainage (R405) N/A Anchorage in SDC D (R403.1.6.1) N/A Soil class (Table R405.1) N/A Footings adjacent to slopes (R403.1.7) X Dampproofing (R406.1, R406.3, R406.4) N/A Wood foundations (R403.2) X Waterproofing (R406.2) N/A Frost -protected shallow foundations (R403.3) COLUMNS (R407) N/A Precast concrete foundations (R403.4) N/A Wood columns (R317, R40Z 1) FOUNDATION/RETAINING WALLS (R404 - R406) N/A Steel columns (R407.2) X Masonry foundation walls (R404.1.2) N/A Structural requirements (R407.3) X Plain masonry design [R404.1.2.1, R606, UNDER -FLOOR SPACE (R408) Table R404.1.1(1)] N/A X Ventilation (R408.1, R408.2) Reinforced masonry design (R404.1.2.1, N/A R606, Tables R404.1.1(2) - R404.1.1(4)] Unvented crawl space (R408.3) N/A Rubble stone (R404.1.8; R606.4.2) N/A Access (R408.4) X Thickness (R404.1.5.1) N/A Removal of debris (R408.5) N/A Concrete foundation walls (R404.1.3) N/A Finished grade (R408.6) N/A Flood resistance (R408.7) -5- FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (R502) N/A Species and grade (R502.1.1 - R502.1.7) N/A Joists —Sleeping areas [R502.3.1, Table R502.3.1(1)] N/A Joists —Living areas [R502.3.1, Table R502.3.1(2)] N/A Cantilevered joists (R502.3.3, Tables R502.3.3(1), R502.3.3(2)] N/A Girder and header spans (R502.5, Tables R602.7(1) - R602.7(3)] N/A Joists under bearing partitions (R502.4) N/A Bearing (R502.6, R502.6.1, R502.6.2) N/A Lateral restraint and bridging (R502.7, R502.7.1) N/A Cutting, drilling and notching (R502.8) N/A Fastening (R502.9) N/A Framing of openings (R502.10) N/A Wood trusses (R502.11) N/A Draftstopping (R302.12, R502.12) N/A Fireblocking (R302.11, R502.13) LUMBER FLOOR SHEATHING (R503.1) N/A Thickness (Table R503.1) N/A Allowable span (Table R503.2.1.1(1), (2)] N/A End joints (13503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) N/A Grade (R503.2.1) N/A Allowable spans (R503.2.2, Tables R503.2.1.1(1), R503.2.1.1(2)] N/A Installation [R503.2.3, Table R602.3(1)] PARTICLEBOARD UNDERLAYMENT (R503.3) N/A Grade (R503.3.1) N/A Thickness (R503.3.2) N/A Installation [R503.3.3, Table R602.3(1)] TREATED -WOOD FLOORS (ON GROUND) (R504) N/A - General (R504.1) N/A Site preparation (R504.2) N/A Base course (R504.2.1) N/A Moisture barrier (R504.2.2) N/A Materials (R504.3) STEEL FLOOR FRAMING (R505) N/A Applicability limits (R505.1.1) N/A In -line framing (R505.1.2) N/A Floor trusses (R505.1.3) N/A Structural framing (R505.2) N/A Material (R505.2.1) N/A Corrosion protection (R505.2.2) N/A Dimensions/thickness/grade (R505.2.3, Table R505.2.3) N/A Identification (R505.2.4) N/A Fastening (R505.2.5) N/A Web holes (R505.2.6) N/A Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) X General (R506.1) INSP Site preparation (R506.2) INSP Fill (R506.2.1) N/A Base course (R506.2.2) X Vapor retarder (R506.2.3) X Reinforcement support (R506.2.4) EXTERIOR DECKS (R507) N/A Materials (R507.2) N/A Footings (R507.3) N/A Posts (13507.4) N/A Beams (R507.5) N/A Joists (R507.6) N/A Decking (13507.7) N/A Vertical and lateral support (R507.8, R507.9) 19 WALL CONSTRUCTION (Chapter 6) WOOD CONSTRUCTION (R602) X Referenced standards (R602.1.1 - R602.1.11) INSP Stud grade (R602.2) X Design/construction /R602.3, Figures R602.3(1), R602.3(2)] X Stud spacing [R602.3.1, Table R602.3(5)] N/A Interior load -bearing walls (R602.4) X Interior nonbearing walls (R602.5) INSP Drilling and notching —studs (R602.6) INSP Drilling and notching —top plate (R602.6.1) X Headers (R602.7, Tables R602.7(1) - R602.7(3)] INSP Fireblocking (R302.11, R602.8) INSP Cripple walls (R602.9) N/A Wall bracing, lines, panels (R602.10, R602.10.1, R602.10.2) N/A Required length of bracing, method (R602.10.3, R602.10.4; Tables R602.10.3(1) - R602.10.3(4)] N/A Minimum length, connections, support, cripple walls (R602.10.5 - R602.10.10) X Wall anchorage (R602.11) N/A Simplified wall bracing (R602.12) STEEL WALL FRAMING (R603) N/A General (R603.1) N/A Structural framing (R603.2) N/A Material (R603.2.1) N/A Corrosion protection (R603.2.2) N/A Dimension/thickness/grace (R603.2.3) N/A Identification (R603.2.4) N/A Fastening (R603.2.5) N/A Web holes (R603.2.6) N/A Wall construction (R603.3 - R603.5) N/A Headers (R603.6) N/A Studs, tracks and structural sheathing (R603.7 - R603.9) SHEATHING (R604, R605) N/A , Wood structural panels (R604.1 - R604.3) N/A Particleboard (R605.1) MASONRY CONSTRUCTION (R606, R607) X General design, materials, construction (R606.1 - R606.11) N/A Seismic requirements (R606.12) N/A Multiple-wythe masonry (R606.13) X Glass unit masonry (R607.1 - R607.10) EXTERIOR CONCRETE WALL CONSTRUCTION (R608) X Design and construction (R608.1 - R608.10) EXTERIOR WINDOWS AND DOORS (R609) X Design requirements (R609.1 - R609.8) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R610) N/A Applicability (R610.2) N/A Materials (R610.3) N/A Wall panels, construction details (R610.4 - R610.8) NOTES -7- WALL COVERING (Chapter 7) INTERIOR WALL COVERING (R702) N/A Gypsum plaster (13702.2.1) N/A Cement plaster (R702.2.2) N/A Plaster support (R702.2.3) INSP G b d d nel materials m ypsuoar an gypsum pa (R702.3) X Ceramic tile (R702.4) N/A Other finishes (R702.5) N/A Wood shakes and shingles (13702.6) N/A Vapor retarders (R702.7) EXTERIOR WALL COVERING (R703) X Water/wind resistance (R703.1.1, R703.1.2) X Water -resistive barrier (R703.2) INSP Attachment and minimum thickness [R703.3, Table R703.3(1)] INSP Flashing (R703.4) N/A Mood siding (R703.5) N/A Wood shakes and shingles (R703.6) N/A Exterior plaster (R703.7) N/A Stone and masonry veneer (R703.8, Table R703.3(1), Figure R703.8) N/A Exterior insulation and finish systems (R703.9) N/A Fiber cement siding (R703.10) N/A Vinyl siding (R703.11) N/A Adhered masonry veneer (R703.12) N/A Insulated vinyl siding (R703.13) N/A Polypropylene siding (R703.14) N/A Cladding attachment (13703.15 - R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) X Lumber type (17802.1.1 - R802.1.4) N/A Fire -retardant -treated wood (R802.1.5) X Design and construction (R802.2, Figures R606.11(1)-(3)] INSP Ridge (R802.3) INSP Purlins (R802.4.5, Figure R802.4.5) INSP Collar ties (R802.4.6) INSP Bearing (R802.6) INSP Cutting, drilling and notching (R802.7) INSP Lateral support and bridging (R802.8) X Framing of openings (R802.9) X Wood trusses (13802.10) X Roof tie -down .(R802.11) CEILING JOISTS [Tables R802.5.1(1), R802.5.1(2)] X Without attic storage, LL =10 psf X With attic storage LL = 20 psf X Spacing X Species and grade X Span X Size RAFTERS [Tables R802.4.1(1) - R802.4.1(8)] N/A Ground snow load/LL = 20 psf N/A Controlling design (LL or snow) INSP Ceiling not attached/ceiling attached INSP Spacing INSP Species and grade INSP Span INSP Size INSP HIHR; Adjustment factor ROOF SHEATHING (R803.2) INSP Grade X Thickness N/A FRTW allowable stresses/grading X Allowable spans [R803.2.2, Table R503.2.1.1(1)] INSP Installation (R803.2.3) ROOF -CEILING CONSTRUCTION (cont'd.) STEEL ROOF FRAMING (R804) N/A General (13804.1) N/A Structural framing (R804.2) NIA • Material (R804.2.1) NIA Corrosion protection (R804.2.2) NIA Dimension/thickness/grade (R804.2.3) NIA Identification (R804.2.4) NIA Fastening (R804.2.5) NIA Web holes (R804.2.6) N/A Roof construction (R804.3) CEILING FINISHES (R805) INSP Installation (R702, R805.1) ROOF VENTILATION (R806) X Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) X Access requirements (807.1) ROOF ASSEMBLIES (Chapter 9) ROOF CLASSIFICATION (R902) X Roof covering materials (13902.1) WEATHER PROTECTION (R903) INSP Flashing (R903.2) INSP Coping (R903.3) INSP Roof drainage (R903.4) MATERIALS (R904) INSP Compatibility; specifications; physical charac- teristics; identification (R904.2 - R904.4) REQUIREMENTS FOR ROOF COVERINGS (R905) X Underlayment (R905.1.1) NIA Ice barriers (R905.1.2) X Asphalt shingles (R905.2) NIA Clay and concrete tile (R905.3) NIA Metal roof shingles (R905.4) NIA Mineral -surfaced roll roofing (R905.5) N/A Slate shingles (R905.6) N/A Wood shingles (R905.7) N/A Wood shakes (R905.8) N/A Built-up roofs (R905.9) N/A Metal roof panels (R905.10) N/A Modified bitumen roofing (R905.11) N/A Thermoset single -ply roofing (R905.12) N/A Thermoplastic single -ply roofing (R905.13) N/A Sprayed polyurethane foam roofing (R905.14) N/A Liquid -applied roofing (R905.15) NIA Photovoltaic shingles (13905.16) N/A BIPV roof panels (R905.17) ROOF INSULATION (R906) X General, referenced standards (R906.1, R906.2) ROOFTOP -MOUNTED PHOTOVOLTAIC PANEL SYSTEMS (R907) N/A Design and installation (R907.1) REROOFING (R908) N/A Materials and methods (17908.1) NIA Structural support (R908.2) N/A Replacement/recovering (R908.3, R908.4) CHIMNEYS AND FIREPLACES (Chapter 10) MASONRY FIREPLACES (R1001) N/A Construction (R 1001.2, Figure R 1001.1; Table 1001.1) NIA SDC D reinforcing/anchorage (R1001.3 and R1001.4) N/A Firebox walls and dimensions (R 1001.5, R 1001.6) N/A Steel fireplace units (R1001.5.1) N/A Lintel (R1001.7) N/A Smoke chamber (R1001.8) N/A Hearth extension (R1001.9, R1001.10) N/A Fireplace clearance (R1001.11) N/A Fireblocking (R1001.12) MASONRY CHIMNEYS (R1003) N/A Construction (R1003.2, Table R1001.1; Figure R1001.1) N/A SDC D reinforcing/anchorage (R 1003.3, R 1003.4) N/A Corbeling (R1003.5) CHIMNEYS AND FIREPLACES (cont'd.) N/A Changes in dimension (R1003.6) N/A Offsets (171003.7) N/A Additional load (R1003.8) N/A Termination (111003.9) N/A Chimney/rain caps (R1003.9.1, R1003.9.3) N/A Spark arrestors (R1003.9.2) N/A Wall thickness (R1003.10) N/A Flue lining - material/installation (R1003.11, R1003.12) N/A Multiple flues (R1003.13) N/A Flue area (appliance) (R1003.14) N/A Flue area (masonry fireplace) (R1003.15) N/A Cleanout openings (R1003.17) N/A Chimney. clearances (R1003.18) N/A Fireblocking (R1003.19) N/A Chimney crickets (R1003.20) FACTORY -BUILT FIREPLACES (R1004) N/A Listed and labeled (R1004.1) N/A Installation (R1004.2 - R1004.5) FACTORY -BUILT CHIMNEYS (R1005) N/A Listed and labeled (R1005.1) N/A Installation (R1005.3, R1005.4) N/A Insulation shield (R1005.8) N/A Inlet (R1003.16) EXTERIOR AIR SUPPLY (R1006) N/A Intake size (R1006.2, R1006.4) ENERGY EFFICIENCY (Chapter 11) X Compliance; information INSP Electrical (N1104) (N1101.5, N1101.13) X Simulated performance (N1105) X Climate zone (Table N1101.7) N/A ERI compliance alternative (N1106) X Building thermal envelope (N1102) N/A X Existing buildings (N1107 - N1111) Systems (N1103) MECHANICAL (Chapters 12-23) INSP Appliance labeling (101302, M1303) N/A Chimneys and vents (Chapters 10,18) INSP Appliance access (M1305, M1401) INSP Appliance installation (M1307) X Heating and cooling equipment; and appli- ances (Chapter 14) X Exhaust systems (Chapter 15) X Duct systems (Chapter 16) INSP Combustion air,(Chapter 17) X Special appliances equipment and systems (Chapter 19) INSP Boilers/water heaters (Chapter20) N/A Hydronic piping (Chapter2l) N/A Special piping and storage systems (Chapter 22) N/A Solar thermal energy systems (Chapter23) FUEL GAS (Chapter 24) N/A Application (G2401.1) N/A Clearance .reduction (G2409) N/A General regulations (G2404) N/A Electrical and electrical bonding N/A Structural safety (G2405) (G2410, G2411) N/A N/A General (G2412) Appliance location (G2406) N/A N/A Combustion, ventilation and dilution (G2407) N/A Pipe sizing (G2413) N/A Installation (G2408) Piping materials (G2414) -10- FUEL GAS (cont'd) N/A Piping system installation (G2415) N/A Valves, controls, connections N/A Piping bends and changes in direction (G2416) (G2420, G2421, G2422) N/A N/A Inspection, testing and purging (G2417) General (G2425) N/A Piping support (G2418, G2424) N/A Venting (G2426 - G2429) N/A Drips and sloped piping (G2419) N/A Misc. appliances (G2423, G2430 - G2454) PLUMBING (Chapters 25-33) INSP Structural and piping protection (P2603) N/A Sprinkler coverage (P2904.2.4) INSP Trenching and backfilling (P2604) INSP Piping materials (P2904.3) INSP Piping support (P2605.1, Table P2605.1) INSP Flow rates (P2904.4.1, P2904.4.2) INSP Materials evaluation and listing (P2609) INSP Water supply capacity (P2904.5.2) INSP Plumbing fixtures (Chapter27) INSP Pipe sizing (P2904.6) INSP Water heaters (Chapter28) INSP Sanitary drainageNents (Chapter 30, Chapter 31) Water supply and distribution (Chapter 29) INSP N/A Dwelling unit fire sprinkler systems (P2904) Sumps and ejectors (P3007) INSP INSP Backwater valves (P3008) NFPA 13D system (P2904.1) INSP INSP Temperature rating Fixture traps (P3201) (P2904.2.1, P2904.2.2) INSPStorm drainage (Chapter33) INSP Freezing protection (P2904.2.3) ELECTRICAL (Chapters 34-43) INSP Penetrations of fire -resistance rated assem- INSP Wiring methods (Chapter38) INSP blies (E3402.2) INSP Required lighting and receptacle outlets q(E3901, Listed and labeled materials (E3403) E3903) INSP Service equipment and location INSP Ground -fault and arc -fault circuit -interrupter (E3405, E3601, E3606) protection (E3902) INSP Service size and load calculations (E3602) INSP Devices and lighting fixtures (Chapter40) INSP Available fault current (E3606) INSP Appliance installation (Chapter4l) INSP System grounding (E3607) N/A Swimming pools (Chapter42) INSP Required branch circuits (E3703) INSP Class 2 remote -control, signaling and power- INSP limited circuits (Chapter43) Feeder requirements and load calculations (E3704) r MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E) N/A Provisions adopted (R102.5) N/A Compliance with Appendix E verified RADON CONTROL METHODS (Appendix F) INSP Provisions adopted (R102.5) INSP Compliance with Appendix F verified -11- PATIO COVERS (Appendix H) N/A Provisions adopted (R102.5) N/A Compliance with Appendix H verified PRIVATE SEWAGE DISPOSAL (Appendix 1) N S P Provisions adopted (R102.5) I N S P Compliance with Appendix I verified EXISTING BUILDINGS AND STRUCTURES (Appendix J) N/A Provisions adopted (R102.5) N/A Compliance with Appendix J verified SOUND TRANSMISSION (Appendix K) N/A Provisions adopted (R102.5) N/A Compliance with Appendix K verified HOME DAY CARE—R-3 OCCUPANCY (Appendix M) N/A Provisions adopted (R102.5) N/A Compliance with Appendix M verified AUTOMATIC VEHICULAR GATES (Appendix O) N/A Provisions adopted (R102.5) N/A Compliance with Appendix O verified TINY HOUSES (Appendix Q) N/A Provisions adopted (R102.5) N/A Compliance with Appendix Q verified LIGHT STRAW -CLAY CONSTRUCTION (Appendix R) N/A Provisions adopted (R102.5) N/A Compliance with Appendix R verified STRAWBALE CONSTRUCTION (Appendix S) N/A Provisions adopted (R102.5) N/A Compliance with Appendix S verified SOLAR -READY PROVISIONS (Appendix T) N/A Provisions adopted (R102.5) N/A Compliance with Appendix T verified -12-