HomeMy WebLinkAboutAPPROVED 11876 Willis Rd - Roof Info SheetST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of Attachments Required
the Permit Application See List Below
Form
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,5,6,7
Wood Shingles and
hakes
A, B, D
1,2,4,5,6,7
ther
rC
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable}:
1.
Fire Directory Listin�Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6. Owners Notification for Roofing Considerations (Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORK
Section A (General Information)
Master Permit No. Q . D / Process No. --t
Contractors Name—VkiE2Ct , .fin �P `�V� License #
JobAddres \\ Gn �C 0 wxW1, "
O Low Slope
O Asphaltic Shingles
Cl New roof ❑ Repair
Low Slope Roof Area (SF)
ROOF CATEGORY
M Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles
"EMAetal Panel/Shingles E3Wood Shingles/Shakes
0 Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ Maintenance eroofing
. ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) \ v'
Cl Recovering
Total (SF)
Section B (Roof Plan) .5�^
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflo�.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Premium Report
4/19/2021
11876 Willis Rd, Fort Pierce, FL 34945-2133
LENGTH DIAGRAM
Total Line Lengths:
Ridges = 37 ft
Hips = 49 ft
Valleys = 0 ft
Rakes = 81 ft
Eaves = 181 ft
Flashing = 28 ft
Step flashing = 20 ft
Parapets = 0 ft
Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet In some cases, segment labels
have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9).
p 2008-2021 Eagb View Te hnObgk , Ine. arc! Pkbamelry Intemebmi CWp. -R0 Righ%Resarvat - POA [ try Europa n Parent AWkOUOO W. 10162199.3 - fnrvel by ON Or mae Of U.S. Pabmf ". 0,070,436; 8,145,578; 8,170,040;
0,209,152; 8,515,125; 8,825,454; 9,135,737; 8,628,961; 9,514,569; 8,01&778; 0,542„880; 9,244,589; 9,329,749; 9,599,466. (AMr Pa@nb PenbMg.
PAGE 4
ST. LUCIE 'NORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: —Zone 2: _Zone 3: _
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_."
oc @ Lap, # Rows—
0"oo '
Zone 1:_"
oc @ Lap, # Rows
_ 0 "Do
Zone 2:_"
oc @ Lap, # Rows—
®"0
Zone 3:—"
oc @ Lap, # Rows-4
"0 '
Number of Fasteners Per Insulation Board:
Zone 1':—Zone 1!Zone 2:—Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: ��
Notice of Acceptance Number: �-L 2.\
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 1 \
Zone 1:�y�' Zone 2e:1one 2n:��`Vone 2r-w one 3e:' U\ zone 3r: � (PLO' 9�?
Deck Type:
\ennt
Roof Slope:
12 rrier:tener Type & Spacing:
Adhesive Type: F 1 p
Type Gap Sheet 7t�j
b
Mean Roof Height: Roof Covering:
Type & Sim Drip N�
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Met od 1 or 2. Compare the values for Mr with the values from Mr. If the Mf values
are greater than or equal to the M,values, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1:
_x2,_=
(Zone 2e:
_x).-=
(Zone 2n:
-xX-=
(Zone 2r:
-xX-=
(Zone 3e:
-x%-=
(Zone 3r:
-x)L-=
-)-M9
-=Mrz•-
-)-M9'-=Me,-
-)-M9'-=Mm-
-M9:-=Ms,-
-a-M9:-=M,
Product Approval M
Product Approval Mr
Product Approval Mr
Product Approval Mf
Product Approval Mf
Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (M,) From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof Slope
15,
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
1 25.9
1 27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F' values are greater than or
equal to the F,values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1:
x L=
x W:=
) -W:
cos r
=Fri
(Zone 2e:
x L=
x W:=
) -W:
cos r
=F,2e_
(Zone 2n:
x L=
x W:=
) -W:
cos r
=Fr2n_
(Zone 2r:
x L=
x W:=
) -W:
cos r
=Fr2r_
(Zone 3e:
x L=
x W:=
) -W:
cos r
=Fr3._
(Zone 3r:
x L=
x W:=
) -W:
cos r
=Fr3r_
Product Approval F',
Product Approval F'.
Product Approval F'.
Product Approval F'_
Product Approval F'.
Product Approval F'.
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
B
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
M,
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Me
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.