HomeMy WebLinkAboutEnergy Calculation Form & Manual J's File Copy
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: ��j°�'1`� `S:�. p Jurisdiction:
Design Location: FL,West Palm Beach . County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1437.3 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
b.Frame-Wood,Exterior R=11.0 187.33 ft2
3. Number of units, if multiple family 1 c..N/A R= f{2
4. Number of Bedrooms 2 d. N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 1446 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(139.2 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 320
a. U-Factor: Dbl, U=0.54 99.23 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
i Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1446.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 53.72 PASS
Total Baseline Loads: 54.66
I hereby certify that the plans and specifications covered by Review of the plans and O�TSE Spq?F
this calculation are in compliance with the Florida Energy specifications covered by this FO
Code. calculation indicates compliance
with the Florida Energy Code. ti rrrr, _''•:.;= .` °;�.��,� O
PREPAR. D Y: Before construction is completed
DATE: _ this building will be inspected for y
compliance with Section 553.908 * °
I hereby certify that this building, as designed, is in compliance Florida Statutes. 5�
with the Florida Energy Code. �''OD W%W
OWNER/AGE I BUILDING OFFICIAL:
DATE: �S\\� DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
4/3/2017 6:53 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,West Palm Beach FL WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1446 12514.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes
2 WIC 54 432 No 0 1 No Yes Yes
3 MASTER BATH 63 504 No 0 1 Yes Yes Yes
4 M.BATH 56 448 No 0 1 Yes Yes Yes
5 KITCHEN 172 1376 Yes 0 1 No Yes Yes
6 BATH 45 360 No 0 1 Yes Yes Yes
7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes Yes
9 GREAT/DINING 526 5154.8 No 0 1 Yes Yes Yes
10 FOYER 50 400 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ____ 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ____ 0 1 0
4 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 ---- 0 1 0
5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ___- 0 1 0
6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 _--- 0 1 0
7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ____ 0 1 0
4/3/2017 6:53 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant,Software Page 2 of 5
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 _-__ 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ____ 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
4 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood
I
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood
WALLS
Adjacent Cavity ity Width Height Sheathing Framing Solar Below
nrot 10 Wall Type1 N=>SE Exterior Concrete Block-Ext Insf3EDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsdHEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0
3 W=>NE Exterior Concrete Block-Ext InsfHEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext IndUWSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
5 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
7 N=>SE Exterior Concrete Block-Ext InsEEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext In!EffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0
10 S=>NW Exterior Concrete Block-Ext In!8EDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0
11 S=>NW Exterior Concrete Block-Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext InsdREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
4/3/2017 6:53 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent S9 Ornt To Wall lypepace Cavity Width Height Sheathing Framing Solar Below RAtah
Et In Et In Area R-Vahle Frartion Ah
13 W=>NE Exterior Concrete Block-Ext IneGREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
16 N=>SE Exterior Frame-Wood GREAT/DINI 11 23 5 8 187.3 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315ft2 315ft2 24ft 8ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA Egl-A ACH ACH 50
1 Wholehouse Proposed ACH(50) .000385 1460.1 80.16 150.74 .2656 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
4/3/2017 6:53 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— ---Return— Air CFM 25 CFM25 HVAC#
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr [ May X Jun X Jul rl Au X Se [ ]Oct Nov Dec
Heatin HJan f X�Feb Mar AprMayJun 4 Jul Au Sep [ ]Oct X�Nov Dec
Ventin Jan [ Feb X Mar [X]A r [ Ma [ Jun [ Jul Aug [ Se [X]Oct [X Nov H Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
4/3/2017 6:53 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,West Palm Beach
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 6:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
I