Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's (2)
Fide Copy FORM R405-2014 = ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood, Exterior R=11.0 187.33 ft 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 2 d.N/A R= ftz 5. Is this a worst case? 10.Ceiling Types Insulation Area Yes a.Under Attic(Vented) R=30.0 1446.00 ftz 6. Conditioned floor area(ftz) 1446 b.N/A R= ftz z 7. Windows- Description Area c' _ ft a. U-Factor: Dbl,U=0.54 99.23 ftz 11.Ducts R ftz SHGC: SHGC=0.25 a.Sup:Attic,Ret:Attic,AH:Attic 6 320 b. U-Factor: Dbl, U=0.55 40.00 ftz SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft EF:0.97 b. N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building -ERE ST,q�, Construction through the above energy saving features which will be installed (or exceeded) 01 = �o in this home before final inspection. Otherwise, a new EPL Display Card will be completed �,,,'''��' r'c+ based on installed Code compliant features. :J Builder Signature: Date: Address of New Home: City/FL Zip: 2�C�P. *mac WF *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2017 6:53 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 File COPY - - wrightsoft Project Summary Job:: Endre House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUIQKCALCS !AQL.COM' Proiect Information-- For' THE GRAND CARLTON \WYNNEgDEVE\LO(IPMENT, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside db. 75 OF . Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none). Humidification 0 .Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent(0 cfm) 0 Btuh Heatingg . Cool' (none) Area(ft2) 1446 1446 Equipment latent load 5521 Btuh Volume(ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make . Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 Efficiency 8.5 HSPF AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER. Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27. °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O 'Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=32 OF Backup: Input=7 kW, Output 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 9- wrightsoft` Right- 2017-Apr-11 09:29:38 ICCkSuite®Universal 2017 17.0.14 RSU08101 Pagel ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N wry htsofty Ri ht-M Worksheet Job: .9 g date: Entire House By: QUICK CALCS, INC. 317 ST..LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire.House BEDROOM 2 E)Med wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2. Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool. Gross WKS Heat Cool Gross WP/S Heat Cool 6 13A-0o6s 0143 :n` 4.00 255 503 465 „1862 1184 72'=- 72 % 288 183 AA5-2om 0 770 W. 21:56 19.31 :38 0 815 730' 0: 0 0. 0. 13A-4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 --G 1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 ' D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W `13A46cis . 0.143' se 4.00 2.55 34 :. 34 136 .86 0 0 \�! 13A4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 L-�G 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A4ocs 0143 w 4.'00 255 310 237 949 603 104 72 288 183 1Ac1om `.: 1 270 w: 35:5ti 55:21 32 2 1140: 1770 32 2 1140 17701 4A5r2am .0.770 w' 2156 ,19:31 41, 41. : 880 788, 0' 0, s_0 0 P 12C-Osw 0.091 2.55 1.28 192 192 489 246 0 0 0 0 C _16A�Omd' .2 32 1446 4446 :.1295 3354`,;; 297 ;297 266 689 22A tpl. 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED erxursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a). Infiltration . 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 20M 0 Subtotal(lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Lessaransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503. 26056 6653 7325 Air required(cfm) 1160 11601 328 326 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed .� wrightsoft Right-Sulte®Universal 2017 17.0.14 RSU08101 2017-Apr-11 06:29:38 p` Page 1 uick Calcs\Documents\THE GRAND CARLTON-1446.rup. Cale=MJ8 Front Door faces: N -wrigntsoft- Right-J®Worksheet °b : Entire House Date` QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS _AOL.COM 1 Room name WIC KrrCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ftz 172.0 ft' Ty .Construction U-value Or HTM Area (W) Load Area (ft-) Load number (Btuh/ft1-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13Allocs) :0143 - n= 4:�00 2.55 0 0 0 0 0: 0 .:p 0. ,4A5-2om r 0.770 n' _. 21:56 19:31 . 0 0 0 0. b... ;.0 ,.cp -0 13A flocs 0.143 . e 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 87.29 0 0 .0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs. 0.143 se 4.00 255 0 0 0., 0 0 0 -.0 0 13A-4ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 t-G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 "I 3A.,446Cs 0143 . w 4.00 2.55 0 0 0 .0 0 0 :0 0 1Ac1om:; 1270 w 35.56 55.21 0 0 0 0 0 0 0 0 ±4A5 2om. .. . 0.770 w .21 58_ -19.31 : 0; '0 0 0 0 0;... 0 0 P. 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C __':16A30md--:- -0 032 ::'= .:0:90.- 2.32•' S4 c.: 54 48 125 172 172 ,,'154 399 F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 .0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 48 117 317 2311 Less external load 0 0 '0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 4k. 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required(cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J-8th Ed. - -" .....ightsoft Right-Suite®Universal 2017 17.0.14 RSUD8101 2017-Apr-11 0 Page 2 uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N 9 - wrightsoft' Right-J®Worksheet Job: Entire House Date: BY: QUICK CALLS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name BATH BEDROOM 2 2 =ed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x' 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft' 203.5 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ft) Load number (Btuhfftl-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 5 V�/ I13A-4ocs 0143 _n, ,400 2:55 40 40 160 102 128 128 613 326 `4A52om..;;: : :.0.770'-�ri' -21 56 . ..19.31_ .:0 0 :0 0- -:0- . .>0. - ::50 -:0. 13A4ocs 0.143 a 4.00 2.55 0 b 0 0 .80 56 225 143 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W - .13AAocs 0:143 se .4.00 2.55 0 0 0 0 34 -34 136 86 13AAocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 t-G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13AAocs .0143 w 4.00 '255 0' 0 0 0 0 0 0 0 1A-c1om ;, y 270 .w. 3556 5521 p 0 0,`. 0: 0 0 0 0 4A5 tom 0.770_:w 21 56 19 31' 0 0 0 0 0. 0._. 0 :: 0: P 12C-0sw_ 0.091_ - 2.55 _ 1.28 0 0 0 0 ., 0 0 0 0 0_'. . ', 16A30md ,0.032 -_ 0:90 2.$2' 45 45; -<.`-.40 . 104 -..204: -,204 982 472 F 22A tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED excursion -16 _85 Envelope loss/gain 339 196 2978 3106 12 a) Infiltration . 87 24 593 162 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal pines 6 to 13) 425 214 3571 3498 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required(cfm) 28 14 232 232 .Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoft� 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N -wrightsofts Right-J®Worksheet °b Entire House Date:. By: QUICK CALCS,INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ftz 526.0 ft2 Ty .Construction U-value. Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft{°F) (Btuh/ft1) or perimeter (ft) (Btuh): or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A flocs=` 0 143 n. 400 255 0 p 0 0 255 217 869 552 4A5 tom n 24;5.6 "' 19.31 0 0', •'... ..:0' _ 0 38' 0 815 `_730: 13A-0ocs 0.143 a 4.00. 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-46cs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 tV!/ 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 -G 1A-clom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A41ocs 0143 w 4.00 2.55 0 0 0 0 206 165 661 420, 1Ac1om;- 1 270 ;w. 35.56 55.21 0 0 0 0'. -0, 0 4A5 tom. ' 0 770 :w 21:56 19:31 0 0 0 0 . 41 4.1 880 788 P 12C-0sw 0.091 - 2.55 1.28. 56 56 143 M 0 0 0 0 C s16A 30.md :'. '0.:Om .- 0:90 :'. 232- -42 :. 42 "48 . 97 -526 526, ;.,.471 1220 F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 526_ 47 1302 0 j. 6 c)AED excursion -221 668 Envelope loss/gain 539 270 4997 4379 12 a): Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal pines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required(cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft' Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N a 9e 4 - wrightsoft' Right-J®Worksheet Job: _ Entire House Date: QUICK CALLS, INC. By. 317 ST.LUCIE LN.,FT PIERCE,FL 34946 Phone:M-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM 1 Room name FOYER M.BATH 3 Room h l height 8.0 ft 7.0 ft heat/cool 8.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft m 5 Roo area 50.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft-*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 13A _0143 :n 4 0o 255 8 8 32 20; 0 0 0 0 r 4A5 2.om:; 0.770 n 21.56 19:31. =.0. . . . . ,0 A 0 0 0. 0. 0 13A�acs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 - 0 11 _ 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W .13A-4ocs 0.143 se 4.06 255 0 0 0, 0 0 0 01 0 W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 L--G c 1A 1om 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A46cs .0143 w 4.00 2.55 0 0 0 .0 0 0 0 D 1A c1om. .1 270 w: 35.56 55:21 0 0 .. 0'' 0 _ 0.: p p p. 4A5 tom 0 T!0 W. 21': '6 19 31 0 : 0 ' 0 0: 0 P 12C-0sw 0.091 2.55 1.28 72 72 183 92 0 0 0 0 ,C..- 516A 30 'd _ Q032 6 90. 2 32 50 '.` 50 45 116 . 56 58 50 _ 13.0 F 22A tpl 0.91 - - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion -89 -38 Envelope loss/gain 792 4961 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 p 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 913 529 885 . 516 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load T_7 1 1202 787 1 1 1166 768 Air required(cfm) 59135 58 34 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. .� _FV wrightsoft' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 .��A ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 5 Duct.S stem Summa Job: - wrightsoft`a y Date: Entire House BY: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772466-6799 Fax 772-46676796 Email:QUICKCALCS AOL.COM Project • • For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.static pressure .0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length(TEL) 176 ft Supply Branch Detail • Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 0xO VIFx . 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 st1 BEDROOM-A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115..0 st1 M.BATH-A h 768 58 34 0 0 Ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 SupplyDetail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 . 14.0 0 x 0 VinlFlx AQ htsofta 9 wri Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-1109:29:38 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 1 e Return Branch Detail Table Grille Htg Clg TEL Design Veloc . Diam. H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) . FR (fpm). . (in).. (in) Opening(in) Matl Trunk rb1 Ox 0 . 1160 1160 0 0 0 0 - Ox 0 VIFx J A wrightsoft` Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Page 2 ACCK ...uick Calcs\Documents\THE GRAND CARLTON=1446.rup Calc=MJB Front Door faces: N