Loading...
HomeMy WebLinkAboutCompaction Test File Copy Soil Nuclear Gauge Client: Project: Report Date:7/31/2017 Arthur Rutenburg Homes PSL 14-0828.00 Test Method:ASTM D 6938 114 SE Via Lago Garda Arthur Rutenburg Homes-Various Projects lyl�,ANATO�P Port St.Lucie Port St.Lucie,FL 34952 FBPE CA#4930 521 NW Enterprise Drive Port St.Lucie,FL 34966 Phone:772-924-3575 1 Fax:772-924-3590 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. Test# Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (in) Compaction (%) Remark 94 7/20/17 P-8 N/A 11.1 110.3 11.0 107.9 12 98 95/105 Pass 95 7/20/17 P-8 N/A 11.1 110.3 10,8 108.6 12 98 951105 Pass 96 7/20/17 P-8 N/A 11.1 110.3 10.1 110.6 12 100 95/105 Pass Test Information Gauge Test# Test Location Elevation Reference Make 1 Model/SN Field Technician 94 Below Slab Grade:9624 SW Enclave Circle,Port Saint Lucie,NW Corner 0-1 Troxler 3450 737 Marquart,Matthew 95 Below Slab Grade:9624 SW Enclave Circle,Port Saint Lucie,SE Comer 0-1 Troxler 3450 737 Marquart,Matthew 96 Below Slab Grade:9624 SW Enclave Circle,Port Saint Lucie,Center 0-1 Troxler 3450 737 Marquart,Matthew Remarks I Comments Pass:Tests results comply with specifications Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on rile with the testing agency. tWt t e r440 os�oo 4Q Ile 7 5 07/31 0W Donald WATEoIe6,P.E.:L� ofes Tonal EngiIn@Lge 675 OO a Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.