HomeMy WebLinkAboutEnergy Calculation Form & Manual J's File Cop FORM R405-2014 yi FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NAKELSI RESIDENCE Builder Name: Street: 9624 ENCLAVE CIR. Permit Office: City,State,Zip: PORT ST.LUCIE,FL,34986 Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4290.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=9.0 3960.70 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 90.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (4143.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 4143.00 ft2 6. Conditioned floor area above grade(ft2) 3985 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(833.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 425 a. U-Factor: Dbl,U=0.40 833.13 ft2 b.Sup: Attic, Ret:Attic,AH:Attic 6 175 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 56.0 SEER:16.00 c. U-Factor: N/A ft2 b.Central Unit 17.9 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 34.0 COP:1.00 SHGC: b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 10.936 ft. Area Weighted Average SHGC: 0.200 14.Hot water systems 8. Floor Types (3984.5 sqft.) Insulation Area a.Electric Cap:90 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 3984.50 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF,Pstat Glass/Floor Area: 0.209 Total Proposed Modified Loads: 132.36 PASS Total Baseline Loads: 133.99 I hereby certify that the plans and specifications covered by Review of the plans and Q6ZHE ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this `IV Code. calculation indicates compliance e.with the Florida Energy Cod PREPA ED BY: Before construction is completed r ' DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, i in compliance Florida Statutes. with the Florida Energy Co G'OD y��� OWNER AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2014 PROJECT Title: NAKELSI RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3985 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 9624 ENCLAVE CIR. Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST. LUCIE, Family Type: Single-family FL, 34986 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2861 30777 2 AHU 2 1124 13667.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 CLUB ROOM 632 7204.8 No 4 1 No Yes Yes 2 POOL BATH 48 480 No 0 1 No Yes Yes 3 BATH 3 72 720 No 0 1 No Yes Yes 4 BEDROOM 3 227 2270 No 1 1 1 No Yes Yes 5 BATH 2 60 600 No 0 1 No Yes Yes 6 BEDROOM 2 195 1950 No 1 1 1 No Yes Yes 7 CLST. 40 400 No 0 1 No Yes Yes 8 STORAGE 49 490 No 0 1 No Yes Yes 9 UTILITY 204 2040 No 0 1 No Yes Yes 10 FOYER 100 1620 No 0 1 No Yes Yes 11 PANTRY 39 390 No 0 1 No Yes Yes 12 HALL 80 800 No 0 1 No Yes Yes I. 13 KITCHEN 221 2519.4 Yes 0 1 No Yes Yes 14 CASUAL DINING 252 2872.8 No 0 1 No Yes Yes 15 GREAT ROOM 473 4730 No 0 1 No Yes Yes 16 HALL. 74 740 No 0 1 No Yes Yes 17 WINE RM. 30 300 No 0 1 No Yes Yes 18 CLST.3 35 350 No 0 1 No Yes Yes 19 CLST.4 30 300 No 0 1 No Yes Yes 20 TLT 35 350 No 0 1 No Yes Yes 21 MASTER BATH 219 2190 No 0 1 No Yes Yes 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 MASTER BEDROO 448 5376 No 2 1 1 No Yes Yes 23 WIC 2 55 550. No 0 1 No Yes Yes 24 WIC 120 1200 No 0 1 No Yes Yes 25 DEN 247 4001.4 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio CLUB ROOM 92 ft 0 631.5 ft2 ____ 0 1 0 2 Slab-On-Grade Edge Insulatio POOL BATH 6 ft 0 48 ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio BATH 3 6 ft 0 72 ft2 -_-_ 0 1 0 4 Slab-On-Grade Edge Insulatio BEDROOM 3 17 ft 0 227 ft2 ____ 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 2 6 ft 0 60 ft2 ____ 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 15 ft 0 195 ft2 _-__ 0 1 0 7 Slab-On-Grade Edge Insulatio CLST. 1 ft 0 40 ft2 ____ 0 1 0 8 Slab-On-Grade Edge Insulatio STORAGE 1 ft 0 49 ft2 ____ 0 1 0 9 Slab-On-Grade Edge Insulatio UTILITY 18 ft 0 204 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio FOYER loft 0 100 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio PANTRY 1 ft 0 39 ft2 _--- 0 1 0 12SIab-On-Grade Edge Insulatio HALL 1 ft 0 80 ft2 0 1 0 13SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 221 ft2 -_-- 0 1 0 14SIab-On-Grade Edge Insulatio CASUAL DINING 23 ft 0 252 ft2 ____ 0 1 0 15SIab-On-Grade Edge Insulatio GREAT ROOM 22 ft 0 473 ft2 ____ 0 1 0 16SIab-On-Grade Edge Insulatio HALL. 5.8 ft 0 74 ft2 ____ 0 1 0 17SIab-On-Grade Edge Insulatio WINE RM. 1 ft 0 30 ft2 __-_ 0 1 0 18SIab-On-Grade Edge Insulatio CLST.3 1 ft 0 35 ft2 ____ 0 1 0 19SIab-On-Grade Edge Insulatio CLST.4 1 ft 0 30 ft2 _—_ 0 1 0 20SIab-On-Grade Edge Insulatio TLT 5 ft 0 35 ft2 ____ 0 1 0 21SIab-On-Grade Edge Insulatio MASTER BATH 34 ft 0 219 ft2 ____ 0 1 0 22SIab-On-Grade Edge Insulatio MASTER BEDRO 55 ft 0 448 ft2 _e_ 0 1 0 23Slab-On-Grade Edge Insulatio WIC 2 1 ft 0 55 ft2 ____ 0 1 0 24SIab-On-Grade Edge Insulatio WIC 15 ft 0 120 ft2 ____ 0 1 0 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 25SIab-On-Grade Edge Insulatio DEN 25 ft 0 247 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 4200 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 3985 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) CLUB ROOM 30 Blown 632 ft2 0.1 Wood 2 Under Attic(Vented) POOL BATH 30 Blown 48 ft2 0.1 Wood 3 Under Attic(Vented) BATH 3 30 Blown 72 ft2 0.1 Wood 4 Under Attic(Vented) BEDROOM 3 30 Blown 227 ft2 0.1 Wood 5 Under Attic(Vented) BATH 2 30 Blown 60 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 195 ft2 0.1 Wood 7 Under Attic(Vented) CLST. 30 Blown 40 ft2 0.1 Wood 8 Under Attic(Vented) STORAGE 30 Blown 49 ft2 0.1 Wood 9 Under Attic(Vented) UTILITY 30 Blown 204 ft2 0.1 Wood 10 Under Attic(Vented) FOYER 30 Blown 167 ft2 0 Wood 11 Under Attic(Vented) PANTRY 30 Blown 39 ft2 0.1 Wood 12 Under Attic(Vented) HALL 30 Blown 80 ft2 0.1 Wood 13 Under Attic(Vented) KITCHEN 30 Blown 221 ft2 0.1 Wood 14 Under Attic(Vented) CASUAL DINING 30 Blown 252 ft2 0.1 Wood 15 Under Attic(Vented) GREAT ROOM 30 Blown 473 ft2 0.1 Wood 16 Under Attic(Vented) HALL. 30 Blown 74 ft2 0.1 Wood 17 Under Attic(Vented) WINE RM. 30 Blown 30 ft2 0.1 Wood 18 Under Attic(Vented) CLST.3 30 Blown 35 ft2 0.1 Wood 19 Under Attic(Vented) CLST.4 30 Blown 30 ft2 0.1 Wood 20 Under Attic(Vented) TLT 30 Blown 35 ft2 0.1 Wood 21 Under Attic(Vented) MASTER BATH 30 Blown 219 ft2 0.1 Wood 22 Under Attic(Vented) MASTER BEDRO 30 Blown 448 ft2 0.1 Wood 23 Under Attic(Vented) WIC 2 30 Blown 55 ft2 0.1 Wood 24 Under Attic(Vented) WIC 30 Blown 120 ft2 0.1 Wood 25 Under Attic(Vented) DEN 30 Blown 338 ft2 0 Wood 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Orat In Wnil Type le Et In Et In Area RA/alue Ernction Ah 1 NE Exterior Concrete Block-Int InsQLUI3 ROOM 9 9 0 11 5 102.8 ft2 0 0 0.5 0 2 SE Exterior Concrete Block-Int InsQLUI3 ROOM 9 31 0 11 5 353.9 ft2 0 0 0.5 0 3 SW Exterior Concrete Block-Int Ins(ALUB ROOM 9 26 0 11 5 296.8 ft2 0 0 0.5 0 4 NW Exterior Concrete Block-Int InsQLUB ROOM 9 26 0 11 5 296.8 ft2 0 0 0.5 0 5 SE Exterior Concrete Block-Int InsdROOL BATH 9 6 0 10 0 60.0 ft2 0 0 0.5 0 6 SE Exterior Concrete Block-Int Insul BATH 3 9 6 0 10 0 60.0 ft2 0 0 0.5 0 7 SE Exterior Concrete Block-Int InsBEDROOM 3 9 17 0 10 0 170.0 ft2 0 0 0.5 0 8 SE Exterior Concrete Block-Int Insul BATH 2 9 6 0 10 0 60.0 ft2 0 0 0.5 0 9 SE Exterior Concrete Block-Int InsBEDROOM 2 9 15 0 10 0 150.0 ft2 0 0 0.5 0 10 NE Exterior Concrete Block-Int Insul UTILITY 9 9 0 10 0 90.0 ft2 0 0 0.5 0 11 NW Exterior Concrete Block-Int Insul UTILITY 9 9 0 10 0 90.0 ft2 .0 0 0.5 0 12 NE Exterior Concrete Block-Int Insul FOYER 9 8 8 16 2 140.1 ft2 0 0 0.5 0 13 SW Exterior Concrete Block-Int Ins(DAASUAL DIN 9 13 0 11 5 148.4 ft2 0 0 0.5 0 14 NW Exterior Concrete Block-Int Ins0ASUAL DIN 9 10 0 11 5 114.2 ft2 0 0 0.5 0 15 SW Exterior Concrete Block-Int InsGREAT ROO 9 22 0 10 0 220.0 ft2 0 0 0.5 0 16 W Exterior Concrete Block-Int Insul HALL. 9 5 10 10 0 58.3 ft2 0 0 0.5 0 17 NW Exterior Concrete Block-Int Insul TILT 9 5 0 10 0 50.0 ft2 0 0 0.5 0 18 NE Exterior Concrete Block-Int Ins8fiASTER BA 9 16 0 10 0 160.0 ft2 0 0 0.5 0 19 SW Exterior Concrete Block-Int InstOASTER BA 9 3 0 10 0 30.0 ft2 0 0 0.5 0 _20 NW Exterior Concrete Block-Int InsUASTER BA 9 15 0 10 0 150.0 ft2 0 0 0.5 0 _21 SE Exterior Concrete Block-Int InsUASTER BE 9 16 0 12 0 192.0 ft2 0 0 0.5 0 _22 SW Exterior Concrete Block-Int InsUASTER BE 9 18 0 12 0 216.0 ft2 0 0 0.5 0 _23 NW Exterior Concrete Block-Int InsUASTER BE 9 21 0 12 0 252.0 ft2 0 0 0.5 0 _24 NE Exterior Concrete Block-Int Insul WIC 9 3 0 10 0 30.0 ft2 0 0 0.5 0 _25 NW Exterior Concrete Block-Int Insul WIC 9 12 0 10 0 120.0 ft2 0 0 0.5 0 _26 NE Exterior Concrete Block-Int Insul DEN 9 11 2 16 3 181.5 ft2 0 0 0.5 0 _27 SE Exterior Concrete Block-Int Insul DEN 9 7 9 16 3 125.9 ft2 0 0 0.5 0 _28 NW Exterior Concrete Block-Int Insul DEN 9 2 7 16 3 42.0 ft2 0 0 0.5 0 _29 NE Exterior Frame-Wood MASTER BA 19 9 10 90.0 ft2 0.23 0.6 0 _30 SE Garage Frame-Wood DEN 11 24 10 240.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated FOYER None .39 6 9 54 ft2 4/24/2017 6:36 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Double Yes 0.4 0.2 60.0 ft2 17 ft 0 in 1 ft 4 in None None 2 SE 2 Metal Low-E Double Yes 0.4 0.2 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 3 Metal Low-E Double Yes 0.4 0.2 60.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NW 4 Metal Low-E Double Yes 0.4 0.2 18.4 ft2 7 ft 2 in 1 ft 4 in None None 5 NW 4 Metal Low-E Double Yes 0.4 0.2 90.0 ft2 17 ft 0 in 1 ft 4 in None None 6 SE 5 Metal Low-E Double Yes 0.4 0.2 10.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SE 6 Metal Low-E'Double Yes 0.4 0.2 8.0 ft2 2 ft 0 in 1 ft 4 in None None 8 SE 7 Metal Low-E Double Yes 0.4 0.2 31.0 ft2 2 ft 0 in 1 ft 4 in None None 9 SE 8 Metal Low-E Double Yes 0.4 0.2 8.0 ft2 2 ft 0 in 1 ft 4 in None None 10 SE 9 Metal Low-E Double Yes 0.4 0.2 15.5 ft2 2 ft 0 in 1 ft 4 in None None 11 NE 10 Metal Low-E Double Yes 0.4 0.2 15.5 ft2 2 ft 0 in 1 ft 4 in None None 12 SW 13 Metal Low-E Double Yes 0.4 0.2 90.0 ft2 17 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 13 NW 14 Metal Low-E Double Yes 0.4 0.2 90.0 ft2 17 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 14 SW 15 Metal Low-E Double Yes 0.4 0.2 160.0 ft2 15 ft 0 in 1 ft 4 in Drapes/blinds None 15 W 16 Metal Low-E Double Yes 0.4 0.2 21.3 ft2 17 ft 0 in 1 ft 4 in None None 16 NW 17 Metal Low-E Double Yes 0.4 0.2 8.4 ft2 2 ft 0 in 1 ft 4 in None None 17 NE 18 Metal Low-E Double Yes 0.4 0.2 24.0 ft2 2 ft 0 in 1 ft 4 in None None 18 NW 20 Metal Low-E Double Yes 0.4 0.2 12.0 ft2 2 ft 0 in 1 ft 4 in None None 19 SW 22 Metal Low-E Double Yes 0.4 0.2 26.0 ft2 2 ft 0 in 1 ft 4 in None None 20 SW 22 Metal Low-E Double Yes 0.4 0.2 24.0 ft2 2 ft 0 in 1 ft 4 in None None 21 NE 26 Metal Low-E Double Yes 0.4 0.2 31.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 792 ft2 792 ft2 24 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000496 5185.2 284.66 535.34 .3621 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP:1 17 kBtu/hr 2 sys#2 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 56 kBtu/hr cfm 0.8 1 sys#1 2 Central Unit Split SEER: 16 17.9 kBtu/hr cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 90 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— --Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ftZ Attic 105 ftZ Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 175 ftz Attic 75 ftz Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar Apr Ma Jun Jul Au Venting Jan H Feb HX Mar Apr i I May ri Jun rl Jul rl Aug rj ep Sep �X�Oct H Nov Dec Nov H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA y Project Name: NAKELSI RESIDENCE Builder Name: Street: 9624 ENCLAVE CIR. Permit Office: City,State,Zip: PORT ST.LUCIE,FL,34986 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/24/2017 6:36 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD Y ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 9624 ENCLAVE CIR., PORT ST. LUCIE, FL, 34986 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2_ Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=9.0 3960.70 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units,if multiple family 1 c.Frame_Wood,Exterior R=19.0 90.00 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a_Under Attic(Vented) R=30.0 4143.00 ft2 6. Conditioned floor area(ft2) 3985 b.N/A R= ft2 7. Windows** Description Area 11 Ducts R_ z R ft2 a. U-Factor. Dbl,U=0.40 833.13 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 425 SHGC: SHGC=0.20 b.Sup: Attic,Ret:Attic,AH:Attic 6 175 b. ,U-Factor: N/A ftz SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 56.0 SEER:16.00 SHGC: b.Central Unit 17.9 SEER:16.00 d. U-Factor WA ft2 SHGC: 13.Heating systems kBtu/hr Efficiency SHGC a.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 10.936 ft. b.Electric Strip Heat 17.0 COPA.00 Area Weighted Average SHGC: 0.200 8. Floor Types Insulation Area 14.Hot water systems Cap:90 gallons a.Slab-On-Grade Edge Insulation R=0.0 3984.50 ft2 a.Electric EF:0.95 b.WA R= ft2 c.WA R= ft2 b. Conservation features None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building S7,q�, Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code iant features. intrt"C--.;; _;:; ;.;;,..�„ Builder Signature: / i Date: nj"� �- W; 1 Address of New Home: "/ �� !!�1�i' (GI/I/�J C City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/21/201711:10 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 N Colts Project Summary Job: - - wrightsoft° Date: Feb 21,2017 AHU 1 Van y QUICK CALCS, INC. 1-40-4— 0011 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM e� t: Project Information For: ANTHONY & MONICA NAKELSKI 9624 ENCLAVE CIR., PORT ST. LUCIE, FL 34986 Notes: Design Information Weather: Fort Pierce, FL, US. Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25285 Btuh Structure 29961 Btuh Ducts 11181 Btuh Ducts 11971 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36466 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 39836 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4025 Btuh Ducts 4687 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling (none) Area(ft2) 2861 2861 Equipment latent load 8711 Btuh Volume(ft3) 30768 30768 Air changes/hour 0.25 0.13 Equipment total load 48547 Btuh Equiv.AVF(cfm) 126 68 Req. total capacity at 0.70 SHR 4.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6061B1 AHRI ref Coil TEM6AOD6OH51++TDR AHRI ref 7795583 Efficiency 100 EFF Efficiency 12.5 EER, 16 SEER Heating input 10.7 kW Sensible cooling 39200 Btuh Heating output 36427 Btuh Latent cooling 16800 Btuh Temperature rise 18 °F Total cooling 56000 Btuh Actual air flow 1867 cfm Actual air flow 1867 cfm Air flow factor- 0.051 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft` 2017-Jun-01 11:20:02 �+-- Right-Suite®Universal 2017 17.0.14 RSU06101 Page 1 �� ...k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJS Front Door faces: N Project Summary Da e: Feb 21,2017 -�- wrightsoft® AHU 2 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM ! Project Information For: ANTHONY & MONICA NAKELSKI .� 9624 ENCLAVE CIR., PORT ST. LUCIE, FL 34986 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10251 Btuh Structure 8173 Btuh Ducts 2884 Btuh Ducts 3211 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13135 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 10815 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2217 Btuh Ducts 1218 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area(ft2) 1124 1124 Equipment latent load 3435 Btuh Volume(ft3) 13678 13678 Air changes/hour 0.36 0.19 Equipment total load 14250 Btuh Equiv.AVF(cfm) 81 43 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.3 kW Sensible cooling 12530 Btuh Heating output 11426 Btuh Latent cooling 5370 Btuh Temperature rise 50 °F Total cooling 17900 Btuh Actual air flow 208 cfm Actual air flow 597 cfm Air flow factor 0.016 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.77 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� wrightsofC Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jun-01 11:20:02 Page 2 ...k Calcs\Documents\NAKELSI,ANTHONY R MONICA.nip Calc=MJ8 Front Door faces: N -�-wrightsoft Right-JO Worksheet Job: AHU 1 Date: Feb 21,2017 BY: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 1 CLUB ROOM G 2 E)posed wall 220.8 ft 92.0 ft 3 Room height 10.8 ft d 11.4 ft heat/cool 4 Room dimensions 1.0 x 631.5 ft 5 Room area 2860.5 ft2 631.5 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 __' Tailored.foam nject 0 000 n ne. 0.00 0.00 r 333 -203 0�.- 0 ^103- 43 0 11 j4A5-2ob 0.560 ne 0.00 ' 0.00 '0 0 "0 0 0 b- 0 0 4A5-26b` .0.560 ne 15 68 '33.75 16 0' 243 523, 0 0 0 0 4A5-2ob - 0:560 ne 15:68 33.75: .60 0 941 2025 60 0 941 2025 n� 110>-D -_ -0 390__ne_ 10:92 --11,31 All0._ _ -_0_Y- __0 ___,'__0 Tailored foam inject 0.000 se 0.00 0.00 853 751 0 0 353 323 0 0 4A5-2ob 0.560 se 15.68 16.16 16 32 251 259 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 10 10 157 252 0 0 0 0 4A5-2ob 0.560 se 15.68 . 25.15 30 30 470 755 30 15 470 755 4A5-2ob 0.560 se 15.68 26.63_ 47 38 729_ 1238 0 0 0 0 4 Tailored foam inject Y - 0.000 sw _ - Mo . 0.00 - 665 -- 355 � 0 0 � 296, 1236 `0 f -�0 '4A5-2ob 0.560 sw 15.68 25.15 - 60 60 941 1509 60 30 941 1569 4AS2ob 0.560 -sw 15.68 :11.54 160 320 2509 1846 - 0 0 0 0 4A5-2ob , 0 560 sw 15.68. 9.23 90 . 180 1411, 831 0 0 0. 0 '4AS2om „ 0.770.,sw o.00 ,- 0.o0 0 0 0 0 0 0 0 0, ^_-__ 4AS2om ;, �0:770 sw_, 0:00 __0.00 = -0 ��0 - __ 0 _._. 0 -6_- ��0 - 0 , Tailored foam inject 0.000 w 0.00 0.00 58 37 0 0 0 0 0 0 L-G 4AS2ob 0.560 w 15.68 16.16 21 43 335 345 0 0 0 0 n -__.._-, _n_ji.6- -_ _a_ _ _ - �r- Tailored foam Inlect T p 000 V nw -000, 0.00 600 302 0 - 0 296 188 4AS2ob ''_ 0.560 nw 0:00 0.00 0' 0 0 0 0 0 0 0` 4AS2ob 0._660 nw 0:00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 nw 15.68 33.75. 18 0 289 621 18 0 289 621 4A5-2ob 0.560 nw 15.6.8 33.75- 90 0 1411 3037 90 0 1411 .3037 4AS729b_, _ --_.- 0;560 _nw_,_A5 68 17.59 _-L.9,0„ _._0 m, 1411: ' P_y 12C-Osw- _ 0.091,-,�__ 2.55 1.28_ 250 250 637--�.321 0______-, 0 0 __ 0 2473�2871,- $32-_-. 632 w 56ti _ 657 ^._2.94_i 4.57 -, 167.___.r 167 491 763_- 0__•-__ 0 0 0 -0 ...._632.- __-_92 6 c)AED excursion 6078 1282 Envelope loss/gain 21401 25466 7165 9885 12 a) Infiltration 3884 1115 1691 485 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 4 920 Appliances/other 2000 0 Subtotal(lines 6 to 13) 25285 29961 8856 11290 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 229 349 14 Subtotal 25285 29961 9085 11639 15 Duct loads 44% 40% 111111 11971 44% 40% 4017 4651 Total room load 36466 41932 13103 16290 Air required(cfm) 1867 1867 671 725 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -� wrightsofC 2017-Jun-01 1 Right-Suite®Universal 2017 17.0.14 RSU08101 Page age 1 k Calcs\Documents\NAKELSI,ANTHOW&MONICA.rup Calc=MJ8 Front Doorfaces: N -�-wrightsoft' Right-JO Worksheet Job: _ AHU 1 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name POOL BATH BATH 3 2 Exposed wall 6.0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 8.0 x 6.0 ft 12.0 x 6.0 ft 5 Room area 48.0 ft2 72.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/fF-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 u Tailored.foam inject - - 0.000 ne T -0.00 1 0.00 -- 0- - _O.- -O 0 O 0 0 O 4A5-26b b.560 he 0.00 0.00 0 0 0 0 0 0 0 0 4AS2ob 0.560 ne 15.68 33.75, 0 0 0 0 0 0 0 0 4A5-2ob 0.560 ne 15.68, 33.75 0 0 0 0 - 0 0 0 0 11 -Q 11DO.� --0;390-ne' -_109 -...-2. _.:11.31.--. 0 _ -__ 0-�_0___- Tailored foam inject 0.000 se 0.00 0.00 60 50 0 0 60 52 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 8 a 125 129 4A5-20b 0.560 se 15.68 25.15 10 5 157 252 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 -._ 0 0 0 0 __ 0 _- 0 ._r m 0 0 _�. - _ -6--Q. . �..,_ _ -_._._ ._ .__, ._ _ W Tailored•foam;inject --0._000 sw 0.00 0.00 -'0 � 0 _ 0. 0 0 0 0~" - 0, 4A52ob 0.560 sw 15.68 "25.15 0,' 0 0 0 0 `0 0 0 4A5-2ob _ 0.560 sw 15:68: ,'11.54 0 '0 0., : 0 0 0 - 0 0 4AS2ob 0.560 sw 15.68 9.23 0 0 0 0 0 0 '= 0 0 4A5-2om' 0.770 sw 0.00 0.00 0 0 '0 ' 0 0 0 0 0 4A5-2om _---0.770 sw 0.00 0:00 W. Tailored foam inject 0.000 w 0.00 0.00 - 0 0- 0 0 0 0 0 0 L--G 4A5-2ob A- _ 0.560 w 15.68 16.16 0 0 0 0 0 0 0 - 0 Tailored foam, ect 0.000 nw_ 0.00 0.00 4A5-2ob 0.560 nw 0.00 0.00 01 0 ' 0 0 0 0 0 0 4A5-2ob 0.560 nw 0.00 0.00 0 0 0 0 0 0 0 0 4A5,2ob 0.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4AS2ob 0.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 '0.560.-nw----1.5,68_ 17;59 u _Q ---a-_ 0 P - 12C-Osw 0 091._.__ 255_-1,28. _._ _0 _. -_-_0_ _ 0 0 .0�-.0. __._ 0._ ._ 0 -C-----16D 30td_.w __ -__0 032-_..__0 80 1;04 --- _18_...__48.._:,:__r 43_-K_.-..___72_ __.:72 65__. �.75. _C._-_ 17E-6a1,_- _ ._0.105.--�_ 2.9 4.57 - 0------0 _ ___0.00___48..-__----6.-; 166. --0 - -72' - 6 c)AED excursion 92` 10 Envelope loss/gain 366 3931 356 214 12 a) Infiltration 97 28 97 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 463 421 453 242 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 124 189 83 126 14 Subtotal 587 610 536 368 15 Duct loads 44% 40% 260 244 44% 40% 237 147 Total room load 847 854 773 515 Air required(cfm) 43 38 40 23 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr1ghtsoft' 2017-Jun-01 11:20:02 A Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 2 k Caics\DocumentskNAKELSI,ANTHONY&MON]CA.rup Calc=MJ8 Front Door faces: N 2 - 1-wrightsoft® Right-JO Worksheet Job: AHU 1 Date: Feb 21,2017 _ By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 BATH 2 2 Exposed wall 17.0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 227.0 ft 10.0 x 6.0 ft 5 Room area ' 227.0 ft2 60.0 ft2 Z. Ty Construction U-value Or HTM Area (ft2) Load Area (M Load number (Btuh/ft'°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 failored;foam mject �_0 000"ne` 0.00 500 o 0^ 0 0_' .0 0 0 Y 0' 4AS2ob. ?' 0.560 ne 0.00 0.00 O' , 0 0', 0 0 0 0 0 4A5-2oki. 0:560 ne; 15,68 33.76 °`0 0. '0 0 b 0 : 0 i0 4A5 lob:, ; . `0,560 -ne 15.68 33.75 0 0 Q 0. y 0. 0 -0 0 Q 39010 92 J1 0 Tailored foam inject 0.000 se 0.00 0.00 170 139 0 0 60 52 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 8 8 125 129 4A5-20b 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 31 13 486 825 0 0 0 0 -Tailored;foam nject 0 000 ,sw,: 0.00 0:00 T-O 0 0''N 0 0 0 0 0 4A5-lob, )_ 0.560 sw. 15.68- 25A5 0: _ 0 4A5=2ob 0.560 sw 1,5.68 11�54 ,. 0 o 0 6 "' .0 0 --0 0; 4A52ob 0.`560 sw, 15.68 9.23 -0 o p o 0 0 0 '0 4AS2orri° 0.770 sw 0,00. 0:00 p 0 0 0 0 0 0 0 _ 4AS2om �. 01770 'sw..v O v00_ �00 _._...10_L A_��0 O w�_�o'•. . p W_.. Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 o 0~ V 0 0 L-G 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 0 0 0 Tadored_foa,,mlect-�---70 O00 qe 0.00 0;00 `>0 0 ,0 0 7- 0 ' 0' o 'o. 4AS2ob"r s 0:5B0 nw 0 00 0'00 0.- 0 0 0;.,. 0 -0 ` 0 0 4AS26b ,_ 0:560.-nw s 0:00, 000 ' 0 0 "` 0 0 '0 0 0 * =o, 4AS2ob- 0 560 *rw 15.68 33:75' p 0 0 Q , 0 0 0 0 4AS2ob _0 560 ow 15a 8 ' 33.76 0 0, =0 " 0. 0 =0 0' 0 " 4A5y2ob _? 0 560 nw 15.6$,_A7'59._ P 12C-Osw 0.091 2.55 1..28 0 0 0 w __�0 0 0 0 0 C__, a16D 30td _ _ _._:.j 032___....Y 0 90.: a 1 Q4.v_. 27_.a....s.`::e __ _236 �.r60 :60' J 5_4.=v..-62 C 17B 6a1 0.105, 2.94 4,�57 0 p 0 R� 0 0 Q____o ___ __0 - - - 6 c)AED excursion 294 11 Envelope loss/gain 1160 1355 345 202 12 a) Infiltration 274 79 97 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 11434 1664 442 230 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 5 6 7 14 Subtotal 1439 16691 448 237 15 Duct loads 44% 401/o 636 667 44% 40% 198 95 Total room load 2075 2336 647 332 Air required(cfm) 106 104 33 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsc ft" 2017-Jun-01 11:20:02 Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 3 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N s � -► -wrightsoft° Right-JO Worksheet Job: AHU 9 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 CLST. 2 Exposed wall 15.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 13.0 x 15.0 ft 5.0 x 8.0 ft 5 Room area 195.0 ft2 40.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 'TailoredJoaminjecf 0.000 ne 0.00 0:00 ^ ,0 0 0 _ 0", 0 7 6, 0 7 ",'0 4A5 200 - " "0.560`ne .0:00. 0.00.`. "6` 0 .0 0,- 0` `0 0 �'0 4A5 lob 0;560 ne` 15.68 33.75 0 ,. 0 0 0 0 0 0 0 4A5lob 0 560 ne 15.68 33.75 0 0 0: 0 0 0 0 0 Q. J1DO___d : _ _ �- _0 390 Vie__ JO 9211:31 `0 �_3._v _0_ .. :_:0.____�u_Q ___ -0- W Tailored foam inject 0.000 se 0.00 0.00 150 135 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 16 6 243 413 0 0 0 0 . Tailored foamiriject 0.000 sw 400. 0.00 0 0 0 0T 0 T w ,0 0 -'0 4A5-2ob` 0:560 sw 15168 ; •25.15 0 ', 0 1, 6 o 0 0 0 ,D 4AS2ob';`. ;0:560 sw 15.68,. 11.54 0, 0 0 0` 0 0 0 0 ' 4A5-2ob 0.560 sw 15.0 9 23 0 0' 0 0 `' t1 '0 0 0' 4A5-2om 0.770:sw. . ° '0.00„ ". 0.00 0. 0; , 0 0 0 0 0 0, 4A5 tom '0.770.asw _ 0.00.E C�00_ '0 _�.� -'0 - -0 _'6 s�.0 IW Tailored foam inject 0.000 w 0.00 0.00 0 f 0 0 0 0 0 0 0 L-G 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 _ 0 0 0 Tailoredwfoam'inject -0 000.pw -0.00 0.00'� 0 0' 0 ' 0 0�' 0 0 4 0 4AS2ob 0;560 nw 0:00 r' .0.00 0 . 0 _ 0 0 Q 0 -` -0 0 4A5-26b, b.560 nw, 0 00,'•,, l.b0 ,"0 0 0 0 0 ' 0 0' 0` 4AS2ob :0:560 hw, 15.66; 33:75 0 ,- 0 0 0, 0' 0 0 0 4AS2oti 0.560 nw `15.'68 33.75 0 0• 0 - 0 0 6 0 :0 4A5-24b.,, a� _ 0560 .`hw IA 17_59._ 10_ 01�;_ 0» 0_ _:0-_._.___0'--.-p 0 P 12C-Osw 0.091 2.55 1.28 130 130 331 167 50 50 127 64 __ s 16D_36#d y 0 032_ '9q 1 04 1e95 195_ :_._175 s.203 m40 _v40. C 17B-6al _ _0.105 _ 2.94 4.57 0 0 0 _ 0 0 0 0 0 _-,____-.0 6 c)AED excursion 126 -6 Envelope loss/gain 1164 908 163 100 12 a) Infiltration 242 69 0 0 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ '230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1406 1208 163 100 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 5 0 0 14 Subtotal 1411 1213 163 100 15 Duct loads 1 44% 40% 624 485 44% 4096 72 40 Total room load 2035 1697 235 140 Air required(cfm) 104 76 12 6 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Jun-01 11:20:02 . A Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N '- +-wrightsoft' Right-J®Worksheet Job: AHU 1 Date: Feb 21,2017 QUICK CALCS, INC, BY: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS(i7aAOL.COM 1 Room name STORAGE UTILITY 2 E)q)osed wall 0 ft 18.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 7.0 x 7.0 ft 1.0 x 204.0 ft 5 Room area 49.0 ft2 204.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (M Load number (Btuh/W°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - Taildred fdam inject, 0 0'00-ne 0.00' 0.00'- 0 0' 0 .0_ 90--� 75_ - 0 �-0 4A5r2ob 0.560 ne 0.00 0.00 0' 0 0 0 0 0 0 6 4A5-2ob '0.560 ne 15.68' 33.75 0 0 D,• '0 16 01 243 ,'523 4A5 206: 0.560 ne 1568 33.75 0 0 0' 0 0 0 0 0 �_0:390--pe • J0,02__11,31 Q -.---__-_0 _ - _&---- ___0 Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se _ 15.68 26 _63 --_ 0_ 0 0 _- 0 0 _- 0 0 0 Tailored fdam;inject 3 0.000 sw 0.00_ 0.00_ 0 0 ' .0 _0_ 0 - 0 0 0 4A5-26b 0:560 sw 15.68 25.15' 0 0 0 0 0 0 0 0 4AS2ob 0.560 sw 15.68 11.54 0 0 0 0 0 0 0 0 4A5-2ob 0.566 .sw` 15.68 9.23` 0 0. 0 0 01 ,0 0 0 4AS2om 0:770 'sw 0.00 0.00 0, -0' 0: 0 . 0 0 0 4AS2om --0.770 sw _ _0.00 0100 -----0 -- 0 ---=0------ ---- -- -0 _0 W - Tailored foam inject 0.000 w 0.00 0.00 0 0^ 0 0 0 0 0 0 4AS2ob _ 0.560 w 15.68 16.16 0 0 _ 0 0 _ 0 _ 0 _ 0 0 _ ______ ,-�_____. _---.00 __er-_ Tailored foam inject 0.000 nw 0.00 0.00 0 0 0 0 90 90 � 0 0 4A5-2ob 0.560 nw 0:00 0.00 0 0 r0 ;0 0 0• 0 . 0 4A5-26b o.56o 6w 0.00 0.00 0 0 0 0 0: 0 6 0 4A5-26b 0.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-26b 6.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 _4A5-26b , ,._ _.__0.560_nw- -_15.68 P 12C-Osw_ _PAT,_.. _ 2.55 _ 1`2$ _0 0- - - 0---�__.0 _ - 70-----70 178 90 ---------- ._.�49______49.__.__ 44__,__ 51_�___204, __204 r�183212 C 1713-6al 0.105 2.94 4.57 0 0 0 0 0 0 0 0 F _' 22A tpl-___-_-. _ 0 989__-_ 27:69____0.00 _ 204 6 c)AED excursion -3 48 Envelope loss/gain 44 48 1103 777 12 a) infiltration 0 0 290 83 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 44 48 1393 860 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 19 14 15 _ 14 Subtotal 61 67 1407 875 15 Duct loads 44% 40% 27 27 44% 40% 622 350 Total room load 88 94 2029 1225 Air required(cfm) 5 4 104 55 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wrightsoft^ Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jun-01 1 Page 5 ...k Calcs\Documents\NAKELSI,ANTHOW&MONICA.rup Calc=MJ8 Front Door faces: N g - -wrightsoft Right-JO Worksheet Job: AHU I Date: Feb 21,2017 QUICK CALCS, INC. By: 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name FOYER PANTRY 2 Exposed wall 10.0 ft 0 ft 3 Room height 16.2 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 10.0 ft 1.0 x 39.0 ft 5 Room area 100.0 ft2 39.0 ft2 Ty Construction U-value Or HTM Area Load Area (ft� Load number (Btuh/ft''F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool _.�-__�_ __.�. _ .m_-T- __�_._ - _ __._ __� __ --- 6 Tadore0.foam lnjecf 0.000 ne O.pO 0;00 140' 86 0 0 0 0 0 0 4A5 lob 0.560 ne, 0:00 0.00 0 0 0 0" 0 ,0 0 - .0, 4A5 2oti' _ 0.560 ne 15:68 33.75 0 0• ; 0 0 0 0 0 0 4A5-lob - 0.'560 ne 15.6$' •-33.75 Q 0 0 0.- 0 0 0 0 11 =D 11D0 --- ---- 0 360 ne---_10_92 �1.31. ---, 54 Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 0 0 0 0 0 0 0 0 Tailored.foam.inject 0.000 sw ` 0.00 s .A.00 0 0 0, 0 0 0• 0. 0 4AS2ob 0.560 'sw 15.68 25.15 0 0 0 0 .' 0 0 0 0 4AS2ob 0.560 _sw. 15.68: 11.54 0 0 -. 0 0 0 0 0 0, A15-2ob 0.560,sw 15.68 9.23 0, 0, 0 0 0. 0- ' 0 0 4A5 tom 0.770, sw 0.00 0.00 '0 0 d" 0 0 6 0 0 4A5-2om.`: _ 0:770.sw _ 0.00�0:00 - -0 ----Q � q ___0'. 0 0 - -- -0 U,V Tailored foam inject - 0.000 w 0.00 0.06 0 w 0 0 0 0 0 0 _ 0 TC' 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 0 0 0 -_ Tailoredfioam,inject. _0,00,0 nw - 0.00 0:00 0,� -0 0 _-.-O -O �_ O 0_ r_p 4A5-2obr 0.560 nw 0:00 . aoo 0 0 0 0 0 4A5-2ob - 0:560`nw 0.00 - 0.00. 0•• 0 0 0 0 0 0 0 4A5 2oti'. 0.'560 nw, 1$.68 33.75 0 0 0 0. 0 0 0 0 4A5-2ob 0560 nw 15.68 33.75 0 0 0 0 0 0• 0 0 0 0 . •0 0 P 12C-Osw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 0 r� O 0 C 1713-6al 0.105 2.94 4.57 167 167 491 763 0 0 0 0 -- --- _-_Q �._ _ ,,_-- _-.. -� �--_ _ .Ou989__� _ 27.69 -0,00- - 100 --- 77 6 c)AED excursion -77 -2 Envelope loss/gain 1358 1297 35 38 12 a) Infiltration 226 65 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1583 1362 35 38 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 7 14 Subtotal 1583 1362 41 45 15 Duct loads 44% 40% 700 544 44% 40% 18 18 Total room load 2283 190Fj 59 63 Air required(cfm) 117 85 31 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A 444- wrightsoit' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jun-01 1 Page 6 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N 1 7 -�-wrightsoft Right-JO Worksheet Job: AHU 1 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name . HALL KITCHEN 2 Exposed wall 0 ft 0 ft ' 3 Room height 10.0 ft heat/cool 11.4 it heat/cool 4 Room dimensions 1.0 x 80.0 ft 13.0 x 17.0 ft 5 Room area 80.0 ft2 221.0 f? Ty Construction U-value Or HTM Area (M Load Area (M Load number (Btuh/ftk°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool w .�_ _ -R -�_P.__. -0 ,_ 6 Tadored.foari inject , 0.000 ne' D.00 0.00 fi=0 `, 0 0 ;. 0 0 0 0 0 4A52ob;" `• 6.560 tie (100 0.00 'a 0 0 0 0 D 0 0 4A52ob, b 560 ne 15.fi8 33.75 '0' 0 0 0 0 0 0 0 4A572ob 0 566. ne 15.68 33.76 6 ol 0 0 0' 0 0 0, 0, �0 Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0. 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 0 0 0 0 0 0 0 0 Tailored foam inject r _ 0:000 sw O:DO-7U5 ­_'.6 W ~0 0� 0 -0�4 0 � 0 y'D AA5-2ob `y' 0.560 sw 15.68' 25.,15 "-0 .0- 0 0 , ' 01 0 0 0 4A5-26b 0:560 sw 15.66, 11.54 01 0. 10 - 0 0: 0 0 0� 4A5-2ob`• " 6.566 sw 16.68 9 23' 0 0 0 0 0 ::0 0 ''p, 4A5-26m 0.770 ,sw 0:00• 0.00 0 0 0 0 0 . 0' 0. 0 _w« 4P52oin.' _-0,770 sw: 0.00.= 0-.�_ni.>D. _� = 0 -6 0 `w4 0 Q WI - Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 u --G 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 0 0 0 Tailored fdam inject. 0.000 nw- _-0.00 0;00 , .: ',0�� 0 sm--`:° 0 � . 0 ; 0 '0` 0 ='p, 9A5-2ob ,04560 -nw 0.00 ._ ,0.00 ' . . 0 0 '. 0 0. 0 0 0 0 4A5 lob' D 560 ;riw '0.00 .o,00 _,:0 0 0 0 0 0 0 0' 4A5 lob 0.560 'nw 15;68 33.75 "i 0' 0 0 0 0 0 0 ' 0 4A5 2bb 0:560 nw 15.66 33:75 . 0 0 0` 0 0 0 - 0 0 'QJ 60_ow 15,68_ 17.59 -N-_4` 0 0 _ .`0:---:A`-`_ P 12C-0sw 0.091 �_ 2.55, 1.28 0 �. _ 0 0 0_ 0 0_ 0 _ 0 C i6D 30tc1_. _032_ 0_9_0, 1.04 = C M__1713-6al _ 0.105 _ 2.94 4.57 ,,�� 0_ _._0 _ -0-- 0 0- 0 0_ 0 27�69.,�F:�OY00'._`„ 6 c)AED excursion -4 119 Envelope loss/gain 72 79 198 111 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 72 79 198 2111 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -72 -79 11 12 14 Subtotal 0 0 209 2123 ` 15 Ductloads 1 44% 40% 0 0 44% 40% 92 848 Total room load 0 0 301 2971 Air required(cfm) 0 0 15 132 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsofY 2017-Jun-01 11:20:02 At& Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 7 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N � s - 1-wrightsoft Right-JO Worksheet Job: AHU 9 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM • 1 Room name CASUAL DINING GREAT ROOM 2 Exposed wall 23.0 ft 22.0 ft ' 3 Room height 11.4 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 252.0 ft 1.0 x 473.0 ft 5 Room area 252.0 ft2 473.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load • number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool �- _ e �_ 0.-_ _,._._ _._ ___,____� �_,.__,_..m.,.._�.._a._.w 6 Tailored foam inject - 0.000. ne 0:00 0.00 ���',-0 0 0 0 ': 0 0 0 0 9A5-2ob 0.560 ne 6.00 0.00 0 0 '0 0 :•- D 0 D 0, 4A5;2o$ 0:560 ine 15.68 33:75 '0 . -0 0 6 0 .6 0 ;. 0 4A5-2ob' D.560. ne 15.66, 33:7­5 0'-_ 0 0 0 0, 0 0 '0 11 D'_11 D0 -.w._ �.- v0 390 ne_s.20 92. __11.31. _ _0 __ a Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 0 0 0 0 0 0 0 0 T_ _ _ ,-..,_._- _.-W __ -�_.'.. AV :Tailored�fciam inject 0.000-sw 0.00,. :0:00 148 58 0 0 220' 60 0 0, 4A5-2ob, ,�:0.560 sw, 15:68 25.•15 :0` 0 0 '0 .°` 0 0' 0 .0 9A5-2ob. 0.560 sw 15.68 11.54 ;0 0 0 0 160 160 2509 1846 4AS2ob'..;', ' 0.560 sw 15.68 9.23 90 90 1411 831 ' 0 0 0 D 'UA -tom 0.770 sw 0.00, ; 0.00. .0- 0 0. 0=, 0 0 0 0 4A5 2om`.` _ 0.770 sw0:00..� 0,00 '0 0_ p:� 2 _ �0 W�_ Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 0 0 0 Tailored°foam inject 0 000 nw 0.00 0.00 114 24 0 0. 0 0, 0 p 4A5-2ob;` 0:560 "nw. 0,00 0.00 0 0 ;0 0 0 0 0 ' , 0 4A5lob "; 0:560 nw: 0.00 aoo " 0 0 ;.0 -0 0 6 0' 0 4A5-26b' 6''560 nw 15.68 33.75 0 0 .0 0 0 .0 0 •• 0 4A5lob '' 01560 nw" 15.68_ 33.75 0` 0 "0 .0 0 0 .0 `.0' .-____0 560'nw__15:68 -0. :'0 ,0 .12C-0sw.e ,._ 0091 2.55 1.28 .._ p -- 0 M 0_ _ .. ._ - 0, 0 _0 .90 1 0 ,_�ne: 4 __252 252 ,__226 262 473 473 424 C 1713-6al 0.105 2.94 4.57_ 0 0 � 0 -_ 0 _0_ 0 0 _ 0 0 989` 27;69 0 00 J52.'a_" _23 __-,637 _ -0�- ..473 _ 22__w 608_ _._r__0 _77- 1-7 6 c)AED excursion 1 1949 2034 Envelope loss/gain 3685 4625 3542 4372 12 a) Infiltration 423 121 355 102 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4108 4746 3896 4474 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 217 330 0 0 14 Subtotal 4325 5076 3896 4474 15 Duct loads 44% 40% 1913 2028 44% 40% 1723 1788 Total room load 6238 7105 5619 6262 Air required(cfm) 1 1 319 316 288 279 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 41-wrightsoft- 2017-Jun-01 11:20:02 AtA Right-Suite®Universal 2017 17.0.14 RSU08101 Page 8 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N 10 -�-wrightsoft' Right-JO Worksheet Job: AHU 9 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALL. WINE RM. 2 Exposed wall 5.8 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 74.0 ft 5.0 x 6.0 ft 5 Room area 74.0 ft' 30.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft0 Load number (Btuh/fV°F) (Btuh/ftl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 ne - 0..00 '. 0.00 0 '0 0 0 0 0. 0 0 4A5-2ob`. 0.560 ne 0.00 • 0.00 0 0 0 0 0 0 0 0 4A5 lob`,+ 0.560 ne 15.68 33.75 0 0 0 0 0 0, .' - 0 4A5lob 0:560 ne 15.68 _ 33.75 0 0 0 0 0 0 0 0 11 ____D 11DO _---0:390_ne __10:92_,.__1131 - ___Q._____-._�___. _v0_ _0-_ 00 ._._0 Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 0 _ 0 0_� _ 0�M^0 0 0 _0 Tailored-foam inject' ',0:000 sw 0 00 0.00' -0 .0 0 0 0 0- , 0 '` 0 4A5lob 0;560,sw 15.66 _ 25.15 0 0 ,0 0. 0 0 0 0 4A5-2ob ;; 0 560 .sw 15:68.^ 11.54 ". 0 0 0 ''. 0 0 0 0 0 4A5-26b 0:560 -sw 15.68 , 9.23 :0 , 0 0.. .0 0 0 0 0 4A5 tom 0:770 sw 0.00' 0:0D. 0 0 . '6 0 0 0 0 0 4A5-26m _ .7,70„sw 0.00 `___Q.00-- g_-_ 0 D 0 __0-•--' '0 0 W Tailored foam inject 0.000 w 0.00 0.00 58 37 0 0 0 0 0 0 _�--G 4A5-2ob 0.560 w 15.68 16.16 21_ _ 21 335 _ 345 _ 0 0 0 0 Tailored foam inject -n-000 nw 0:00 0.00 0 0�� 0. 0 r •0,�� 0_~ 0 0 4A5-2ob 0.560 nw 0.00 '. 0.00 0' 0 0 0 0 0 0 0 4AS2ob 0 560 nw, 0.00. O:OD 0 0 0 0 0 '0 0 6 4A5-2ob ```' 0:560 nw �15.68 33:75 0 -0 0 0 0, 0 0 0 4A5-2ob " 0:560. nw 15.68, '33.75 0 . 0 0 0 0 0 0 0 _4A_5_26b _ _ 0 560._nw_ 0 ._ 0 _ ``w 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 _ 0 032_ 0 90 1 Q4�._:._7_4_ 74._ 66 77 $0-_ 30 27_' _ 31 C 17B-6al 0.105 2.94 4.57 0 0 0 0 0 0 0 _0 6 c)AED excursion 545 -2 Envelope loss/gain 560 967 27 30 12 a) Infiltration 94 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 654 994 27 30 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -654 -994 0 0 14 Subtotal 0 0 27 30 15 Duct loads 440/c 40% 0 0 44% 40% 12 12 Total room load 0 0 39 41 Air required(cfm) 0 0 2 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -o- wr1ghtsc f:- 2017-Jun-01 11:20:02 A Right-Suite®Universal 2017 17.0.14 RSU08101 Page 9 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Cale=MJ8 Front Door faces: N i -�-wrightsoft Right-JO Worksheet Job: AHU 1 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS(a@/\OL.COM 1 Room name CLST.3 CLST.4 2 E)posed wall 0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 7.0 ft 5.0 x 6.0 ft 5 Room area 35.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (M Load Area (ft� Load number (Btuh/ft9­°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - ..,4.._._--�- ..._ ,,.e,..�...._.......,_.e.� 6 Tailored_foam inject 0 000'.ne: 0.00, 0.00 ,'' 0 0 0_ 0 0 0 0 0 :4A52obr0.560 ne �,0.00",, 0.00 0 0, FO:' 0°;'`` 0 '' 0 0 0 4A5;2db` i, 0.560 ne 15.68' 3375 0 0 0 0 0' `0 0 0 4A5-2ob "� ;0 560 ne. 15 68_ 33 75 0 : 0 ` 0 0 6 Q 0 0; JJD0 _ 0390 ne• �1092, 1fz 0' Q - Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 16.16 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 15.68 26.63 0 0 0 0 0 0 0 0 Ta lor`ed.foam inject, 0 000�sw 0:00 000 0 �0 0 -00 .'==.0v -0 0' 4A5lob.- ;0.560 sWs 15'6825.�15 �",0 0 -0 ' '0 0 `0� 0 0; 4A5 lob - 0.560 sw, 15.68 11;54 ,'•'0 0 0 0 0 0 0 0 4A5 lob ,'_. 0.560 Sw, 15.68, 9:23 0 p p' p b 0 0 o 4A5-tom;•' Q.770 sw 0,00 0.00 ;. 0 0 - p., 0 D 0 0 '0 4A5 tomes 0_770 sw �'0.00 0:00 ,0 0 r 0%..=-0 _ 0 . .>_0 0 W. Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 16.16 0 0 0 0 0 0 0 0 Tailored foam rn/ect 0 000 nw 0:00 O.pO 0 ,0` 0 0 a0 ,0 0 0 4AS2oti; Z1' :nw 0.00 0'00 O B'r 0 0 0 .'-. - 0 0 0 -.0, 4A5 2ob:'` -0`580;n1v Og00 0:00 0 = 0 �.-0 0 r0 0- �0 �.� 0: 4A5-lob 0 560 nv✓: '15.08 33:75 p ,.,` p 0 0 0.. o f 0 0 4Ar2ob `� A 560 nw:• 15.68; 33i75 ° 0' 0 0 '0 A0 0 ,;0 `4Ar2oli,"_ :0 56D.ariw 15_68 �17 59 00 4 0 y 0 0 0 ma's, ,0 P 12C-Osw _ 0 091 2 55 1.28 0 0 0 0 0 0 0 0 C_, _16D 30td - 0 p32 0 90 10{ ``35v N35•" 31, 36 30 F 30 27 '�31 C _T17Bfal ____0 105 - 2 94 4.57 0 0 0 0 0 00 0 0 --- - _-- - -- 6 c)AED excursion -2 -2 Envelope loss/gain 31 341 271 30 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 31 34 27 30 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 8 9 14 Subtotal 31 34 35 38 1151 Duct loads 1 44% 40%1 14 14 44% 40% 15 15 Total room load 45 48 50 53 Air required(cfm) 2 2 3 2 Calculations approved byACCA to meet all requirements of Manual J Sth Ed. -Fp-wrightsoft' 2017-Jun-01 11:20:02 Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 10 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Doorfaces: N - wrightsot Right-J(H)Worksheet Job: AHU 2 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 2 TLT _ 2 Exposed wall 134.0 ft 5.0 ft 3 Room height 12.2 ft d 10.0 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 5 Room area 1124.0 ft2 35.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (M Load number (Btuh/ftl°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tallore(TC Inject _ _0.600 -ne :0.00. 0.00 372 '517 0 0 '0 0 � .00 0 9A5-2ob .` 0:560 ,he 15.66;- 33:75 `24 0 ' 376 810 0 0 0 -0 s 4A5lob 0.560 ,ne 15.68 3375 31 0 -1 466 1046 0 0 0 0, 4A62ob .0:'560. ne 0 00 ,, 0:00 0 0 ".0 0 0 0 '0 D Tailored foam inject 0.000 se 0.00 0.00 318 318 0 0 0 0 0 0 4A5-20b 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 .0 0 0 0 0 _ 0 0 0 TallOred`fgam Infect.~ 0.000 sw OA0 ',000 246 1 66-.. 0 _ 0 ' 0 0 0 4 'm 0 4A52obt'' 0:560 sw' 0;00: 00,0 0 0. 0'• . . 0 0 0. 0 0 4A5-2ob - 0.560 sw A.00, 0 00 0 0 0 0 0 0 0 0 4A5-26b. •'0.560 sw 0.00 0:00 "0 0 0 0 0 0" 0 0 4A5 tom;= 0.770 sw' 21 t6 '-29 78 26: 21 561 774 0 ^ 0' 0` 0, 4A5-26m - .-v ��: 0.776 sw 21 56` 29JI3_ 24__.. 20__ . 517 715 �' 0:_ :•.D e `0. _ �,0 W Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject _0 000 nw. 0.00 0.00 614 '594 0 0 '50 42' 0 A 4A5 lob' 0.560 hw 15.68' 33.75 12,`�, 0 188 -405 0 `0 '0 --0 4A5-lob" 6:660 nw -15.68' 33.75 "8 0 `: ..132 283 8 0 132 283 4A5-2ob ,• A.560 nw 0,o0, 0:00. 6 0.' 0 0 0 0 0 0 4A5-lob 0:560 nw 0.00, 0;00 '0 0 0 0 `', "0 . 0 0 .__�0..560 nw 0:00____0,Q0- _;'..`_Q _ _.__ _ _0: Y ..0 __0 "5 P 12C-0sw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 _, m_- -.-,tea,_.�,. .Y_�. ,.,.. ,,.r._ __ ____. _-_,.. .. ..._.. C _ 16D 30td_.�' �._ _ 0 032 _� _0:90 ;,,-._,,,1.04_ `S77 =8T/ P7S6 �__1 12 35 , _35 C 176-6al 0.105 2.94 4.57 338 338 995 1546 0 0 0 0 6_q___A.90._._ 1124 �134_,.._,__3711. ---9___35 _138 i. 0 77 6 c)AED excursion 504 97 Envelope loss/gain 7752 6996 302 417 12 a) Infiltration 2499 717 81 23 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 10251 8173 382 440 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10251 8173 382 440 15 Duct loads 1 28% 39% 2884 3211 28% 39% 108 173 Total room load 13135 11384 490 613 Air required(cfm) 208 597 8 32 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. GP. wrightsoft' Right-Suite@ Universal 2017 17.0.14 RSUD8101 2017-Jun-01 P 0 Page k Calcs\Documents\NAKELSI,ANTHONY&MON]CA.rup Calc=MJ8 Front Door faces: N * f -�-wrightsoft Right-JO Worksheet Job: AHU 2 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@40L.COM 1 Room name MASTER BATH MASTER BEDROOM 2 Exposed wall 34.0 ft 55.0 ft 3 Room height 10.0 ft heat/cool 12.0 ft heat/cool 4 Room dimensions 1.0 x 219.0 ft 1.0 x 448.0 ft 5 Room area 219.0 ft' 448.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool _ ,_ _ ..._,t,._. _r.-_F _�__._ _ _,- 6 , Tailored'foam inject'•. 0 000 ne" 0.00: 0.00 160 136m0 TM 0 •,, 0 �0 -' 0 0: 4A5 lob 0 560 ne`' 15.68 33.75 24 0 376 810 0 0 0 0' 4A5-lob 0 560 rie 15:68 33.75 0 0. 0 0 `n •' 0 0 0, 6 4A5-lob• 0;560 ne` • ' 0:00 0,00 0 0 0 J0 0..- 0: ' 0 0 11 � D_ 11 D0 0 390_ Oe_ 0:00_ 0,00�. _ '0 . __Q g_ _ n,_ Tailored foam inject �0.000 se 0.00 0.00 0 0 0 0 192 192 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 00.00 0 0 0 0 0 0 0 0 'Tailored;f'oam~inject - $,0.000 sw; 0:_OD, - 0.00 ,30 u 30 0 0 VY} 2.16 166-- - o ',:0 4A5 2o15 0:560 -sw O.90 0.00 `'b- 0 0' ,0 '0 4q5 2oki 0;560,sw O:OQi•, ` :Q.00 0 0 `0 0 :0 -0' 0 0 4A5 206 0.560 sw 0:00. 0;00 0 0 0 0 0 0 0 0. 4A5 tom " "_ 0 770 ,sw 121.56 29.78 '02 0' 0' ` " 0 26. 11 •561 '774 4A5 tom;`3_ - wu"'0 770 sw 21.58. 29.78 ��°(4 _ 4 024 715 , Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 C 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 Tailored,foam Inject 0"000 :nw O.OQ "0,00 150 • 138 - 0 , 0 252 252 0 0. 4A5 lob "` ,0.580 hNi' 15.68', 33.75 12' •- 0 188 405 °s 0. �0'- 0 >0� AA5 lob' ""y. Q560 nw` 15;68, 33,75 0 0 ' 0 0 0 0 0 0 4A5 lob _ .0'S60 bw 0.06 0.00 - 0,' 0 10 A`"j 0 0, 0 Q 4A5-2ob',', 0 560 nw.: 0.00 0 00 s0 "`$. 0' 0 0 -` 0 0'-= 0 0 _ 4A5lob �'6,560--m Or'_OQ.Q,90 =0' _;_. 0 .; .0 0 __­0 _:..0 _4___:Q P 12C-Osw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 C _16D 30td,`' 0`032 0.90.1 04 : 219=-219 196 228 °_ 448_ 448 C 176-6al 0.105 2.94 4.57 0 0 0 0 0 0 0 0 F n 22Atpl _ -#m,0_989__ ��2769 440_ 219 u 34__ '�942 _�448_ '55:_a 1523 _ m0 __._,.�.__._ r. 6 c)AED excursion -66 597 Envelope loss/gain 1702 1377 3002 2552 12 a) Infiltration 548 157 1064 305 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 2250 1534 4066 3317 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2250 1534 4066 3317 151 Duct loads 1 28% 39% 633 603 28% 39% 1144 1304 Total room load 2883 2137 5210 4621 Air required(cfm) 46 112 82 242 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoTt' 2017-Jun-01 11:20:02 A Right-Suite®Universal 2017 17.0.14 RSU06101 Page 12 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N - -wrightsoft Right-JO Worksheet Job: AHU 2 Date: Feb 21,2017 By: QUICK CALCS, INC. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM ' 1 Room name WIC 2 WIC 2 Exposed wall 0 ft 15.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 11.0 ft 10.0 x 12.0 ft 5 Room area 55.0 ft' 120.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (M Load number (Btuh/ftk°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - Tailored foam ect 0.000 ne 0.00, °0.00 0 �_ 0' 0 0�}�• ..30 30 0 70. 4AS2ob n == 0.560:^ne 15.68' 33.75 _0; 0, 0 0 , �0 0 0 0 _ .. w. .4AS2ob, 0.560 ne 15:66; 33:75' p 0 0 0 0' 0 0 0 4A5-2ob` 0.560 ne` 0:00 0.00 0, 0 0'. 0 •, 0 0 0 0 0 09 ------ "-4 3____Q Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 0 0 0 0 W Tailored foam Inject 90,000 sw 0.00 0:00 0 0 0 0 0 O : 0 0 '4A52ob sv✓ A:00 ,;0.00• 0 0 0= 0- 0. 0' 0 0: •4AS2ob; 0.560 sw- A.,00,`, 0.00 .,0 O `- 0 .0 0- .0,,, 0, ;0' " 4A5 lob `0'560 Sw 000 - ,0.00 0; ' 0 0 0 - 0 0 " 0 0 „4A5-2om 0 770 sw, 21 �56, 29 76 0 D 0 0 0 6% 0 0; _ 4AS2om �_L 0 770 "sw 21 66. 29.78 0 0 0 �j Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 �--G 4AS2ob 0.560 w 0.00 0.00 0 0 0 0 0 0 0 0 ,- To ,.__,„._____nw___.�, ._. _ - __ Tailored foam In/eet' , O'000 r w 0.00 . ,0:00 ` .- 5 .. 6 0 . ,0 '120 _ 120 0 D 4A5lob 0 560 °nw_, 15:68 33.75 0 0; 0 '0 0, 0 0 . 0; AA5.2ob `0.560 nw• .' 15.B6' 33.75 , 0 0 0',.. .. 0 0= 0 0: _0 4AS2ob = 0.560 "nw 0.00 :d:00 0 0 0 0 0 . 6 0 Q 4AS26b w 560 nw 0'00, 0;00 O 0 0, '0 0` `0 O Q _4A52ob r.; . 0 560_nw_�2A4 0_00 0 w _0 ..�:�. _9�y _0 :_ _,, 10--.-0 P _ 12C-Osw _0.091 0.00 0.00 0 _ 0 0 0_ 0_ 0 0 0 C 16D 30td, X ',_ 0 r0320 9D �104 55 55 49 w57 _ 120„_120. 108 C 176-6al 0.105 2.5! 4.57 0 0 0 0 0 0 0 0 F=e22A1pI Vr._ _ .989 w 27,69 0 00 55. - 0 0 120 6 c)AED excursion -2 -8 Envelope loss/gain 49 55 523 117 12 a) Infiltration 0 0 242 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 149 55 765 186 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 Y 14 Subtotal 49 55 765 186 151 Duct loads 28% 39% 14 22 28% 39% 215 73 Total room load 63 76 980 259 Air required(cfm) 1 4 16 14 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 444- .,r1ghtsc ft^ 2017-Jun-01 11:20:02 . GP. Right-Suite®Universal 2017 17.0.14 RSU08101 Page 13 k Calcs\DocumentsMKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N -�-wrightsoft" Right-JO Worksheet Job: AHU 2 Date: Feb 21,2017 3' QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name DEN 2 Exposed wall 25.0 ft 3 Room height 16.2 ft heat/cool 4 Room dimensions 13.0 x 19.0 ft 5 Room area 247.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area Load number (BtuWft?°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter Heat Cool j Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored Edam rnject. ;Q.000 ne 0.00 000 182 151 0"- 0 4A5-lob :{ 0 560 •ne 16.68, 33 75 _ �P�O 0- 0 - 4.5-2ob ":� 0 660 ne 15.68' 33.75 t31 0 486 1096 s: 4AE 2o1i Oi 560 ne' 0.00' 0:00 =0 0 0 r: 0 .._.L.. . Tailored foam inject 0.000 se 0.00 0.00 126 126 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 4A5-2ob 0.560 se 0.00 0.00 0 0 0 0 e._- m .,_ m -_ -Tailored foam inject., 0 000 ,sw' 0.00 D.00 0 0 0 0 4m lob „ '0 560 sw-: 0.00 10.00 0 - 0 0 0 r '4A5-2ob. 0:56'0 ,sw 0.00. 0.00 ;0 0 0 0 4A5 lob, _b 860 sw 0 00: 0 00 k=0 0' 0 ,0 . 4A5-2om -0 770 sw, 21.56' 29:T8 �0 0, 0 0 - - _K__._b_� 4AS2om, `j0:770'sw• 21�56'i, �.29:78_t_,._��0 0 _ 0 ,�„0 . _� W Tailored foam.inject 0.000 w 0.00 0.00 0 0 0 0 4A5-2ob 0.560 w 0.00 0.00 0 0 0 0 - _ -� tailored foam mject " :0 000 nw 0.00; 0:00 42 42 0 0. = 4AS2ob 0 560 nw, 15.68 33.75 0 0 0` 0 ' 4AS26b 0;560 .nw" 15.68 33.7,5 ;0 .r 0. 0 ., 0 4AS2ob 0 560 nW 0.60 0.00 0 0, ` 0 0 4AS2ob '`0 560 nw' 0'00' 000 0 ,° 0 0, 0 4A5 lob q 560 MnW_'. 0 OQ._._ 0.00 ®® 0 LLB,_,. . 0 P 0.091 000 0.00 0 0 0 0 LC ' 16D 30t8 0 032D.90, 1,04==0 0 0==0 C 1713-6al 0.105 2.94 4.57 338 338 995 1546 0 989 27.69; Q_QO 24Z.' 25 692 _ 0 w 71 _z _ - 6 c)AED excursion -114 Envelope loss/gain 2174 2478 12 a) Infiltration 564 162 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 2738 2640 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2738 2640 151 Duct loads 1 28% 39%1 770 1038 Total room load 3508 3678 Air required(cfm) 56 193 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsofC Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Jun-01 1:20:02 Page 14 k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Doorfaces: N T W Duct System Summary Job. -�- wrightsoft Date: Feb 21,2017 3. AHU 9 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.,PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project For: ANTHONY& MONICA NAKELSKI 9624 ENCLAVE CIR., PORT ST. LUCIE, FL 34986 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.188 in/100ft 0.188 in/100ft Actual air flow 1867 cfm 1867 cfm Total effective length (TEL) 266 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk . BATH 2 h 647 33 15 0.336 4.0 Ox 0 VIFx 34.0 115.0 st 1 BATH 3 h 773 40 23 0.219 4.0 Ox 0 VIFx 73.3 155.0 st3 BEDROOM 2 h 2035 104 76 0.479 6.0 Ox 0 VIFx 9.4 95.0 BEDROOM 3 h 2075 106 104 0.270 6.0 Ox 0 VIFx 50.4 135.0 st2 CASUAL DINING-B h 6238 319 316 0.278 9.0 Ox0 VIFx 44.6 135.0 st2 CLST. h 235 12 6 0.486 4.0 Ox 0 VIFx 7.8 95.0 CLST.3 h 45 2 2 0.277 4.0 Ox 0 VIFx 45.6 135.0 st2 CLST.4 h 50 3 2 0.353 4.0 Ox 0 VIFx 26.7 115.0 st1 CLUB ROOM c 5430 224 242 0.192 8.0 Ox 0 VIFx 84.8 175.0 st4 CLUB ROOM-A c 5430 224 242 0.193 8.0 Ox 0 VIFx 84.3 175.0 st4 CLUB ROOM-C c 5430 224 242 0.188 8.0 Ox 0 VIFx 91.4 175.0 st4 FOYER h 2283 117 85 0.311 6.0 Ox 0 VIFx 46.0 115.0 st1 GREAT ROOM-A h 2810 144 139 0.249 7.0 Ox 0 VIFx 65.7 135.0 st2 GREAT ROOM-B h 2810 144 139 0.263 7.0 Ox 0 VIFx 55.0 135.0 st2 KITCHEN c 1486 8 66 0.274 6.0 Ox 0 VIFx 47.6 135.0 st2 KITCHEN-A c 1486 8 66 0.267 6.0 Ox0 VIFx 52.4 135.0 st2 PANTRY h 59 3 3 0.333 4.0 Ox 0 VIFx 35.2 115.0 st1 POOL BATH h 847 43 38 0.224 4.0 Ox 0 VIFx 68.5 155.0 st3 STORAGE h 88 5 4 0.341 4.0 Ox0 VIFx 31.6 115.0 st1 UTILITY h 2029 104 55 0.446 6.0 Ox0 VIFx 17.1 95.0 WINE RM. h 39 2 2 0.285 4.0 Ox 0 VIFx 40.7 135.0 st2 i' 2017-Jun-01 11:20:05 wrightsoft` Right-Suitee Universal 2017 17.0.14 RSUD8101 Page 1 A ...k Caics\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N SupplyTrunk Detail Table a Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk ' st4 Peak AVF 671 725 0.188 787 13.0 0 x 0 VinlFlx st3 st3 Peak AVF 754 786 0.188 1001 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 1487 1621 0.188 823 19.0 0 x 0 VinlFlx st1 st1 Peak AVF 1647 1730 0.188 879 19.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox0 1867 1867 0 0 0 0 Ox 0 VIFx a ► wri9 htsoftf 2017-Jun-0111:20:05 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ZCA ...k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Door faces: N y .0 y Duct System Summary Job: -�- wrightsoft y Date: Feb 21,2017 AHU 2 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM c Project For: ANTHONY& MONICA NAKELSKI 9624 ENCLAVE CIR., PORT ST. LUCIE, FL 34986 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.422 in/100ft 0.422 in/100ft Actual air flow 208 cfm 597 cfm Total effective length (TEL) 119 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat[ Ln (ft) Ln (ft) Trunk DEN c 1839 28 96 0.453 6.0 Ox 0 VIFx 15.3 95.0 DEN-A c 1839 28 96 0.434 5.0 Ox0 VIFx 20.2 95.0 MASTER BATH c 2137 46 112 0.460 7.0 Ox 0 VIFx 13.6 95.0 MASTER BEDROOM c 2310 41 121 0.422 7.0 Ox 0 VIFx 23.5 95.0 MASTER BEDROOM-A C 2310 41 121 0.465 7.0 Ox0 VIFx 12.5 95.0 TLT C 613 8 32 0.473 4.0 Ox0 VIFx 10.6 95.0 wlc h 980 16 14 0.485 4.0 Ox 0 VIFx 8.1 95.0 WIC 2 C 76 1 4 0.500 4.0 Ox 0 VIFx 5.1 95.0 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) R FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 208 597 0 0 0 0 Ox 0 VIFx i 2017-Jun-01 11:20:05 �+ wrightsoft` Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 A ...k Calcs\Documents\NAKELSI,ANTHONY&MONICA.rup Calc=MJ8 Front Doorfaces: N