Loading...
HomeMy WebLinkAboutProduct Approval (3) Ffle Copy, EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization tl9503 T'RINIT Y I 353 CHRISTIAN STREET, UNIT QOERD OXFORD,CT 06478478 PHONE:(203)262-9245 FAX: (203)262-9243 EVALUATION REPORT lll� Entegra Roof Tile, LLC Evaluation Report E39310.11.11-2-R4 r.NTEGRA 1289 NE 9"Avenue FL7804-R9 R O O F T I L E Okeechobee, FL 34972 Date of Issuance:11/02/2011 Revision 4:04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (non- HVHZ)sections noted herein. i DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. P,E.on04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 '' S j- x o m document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the _ product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained - specifically for that purpose. TRINITY I ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5,R905.3.5 Physical Properties ASTM C1492 2003 1507.3.7,R905.3.7 Attachment Requirements FRSA/TRI April 2012(04-12) 2012 1711.2.1 Overturning Moment SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ATL(TST3782) Physical Properties RT0615.01-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.02-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.03-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.04-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.05-11 06/28/2011 ATL(TST3782) Physical Properties RT0316.01-12 05/31/2012 ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015 PRI(TST5878) Physical Properties ESI-001-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-002-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-003-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-004-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-005-02-01 12/12/2006 PRI(TST5878) Physical Properties HRT-023-02-01 11/19/2007 PRI(TST5878) Physical Properties HRT-026-02-01 01/08/2008 Tile Roof Institute SSTD 11 Membership Confirmation Current PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015 Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 2 of 6 TRINITY I ERD 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT,PLANTATION FLAT and HORIZON FLAT are ASTM C1492,Type III (low-profile)concrete roof tiles. 16' -� 1-1/4' 10' r 16' 2' w 10' r Bermuda Flat Plantation Flat / 17-1/4" 13" - Horizon Flat Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 3 of 6 ��TRINFFY�ERD 4.2 BELLA HIGH"S",ESTATE"S"and HACIENDA are ASTM D1492,Type II (medium-profile)concrete roof tiles. 16-2j„ 13-4.1 Bella High"S" Nail Holes • • I& , �3 = Estate"S" 0 e Hacienda Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 4 of 6 TRINITY ERD 4.3 GALENA SPANISH"S"and REGAL are ASTM C1492,Type I (high-profile)concrete roof tiles. 17" 10" Galena Spanish"S" o e 13 1/4" Regal 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar-set and/or adhesive-set) for use with the specific underlayment. For mortar-set or adhesive-set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012(04-12). _ 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 5 of 6 rl� Q0TRINrry I ERD 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3, the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, 5th Edition and, for mortar-set or adhesive-set applications,the mortar or adhesive manufacturer's Product Approval. 6.2 Attachment: Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012(04-12). Mortar-Set or Adhesive-Set Tile: Wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval. Hip and Ridge Tile: _ Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table _ 1A of FRSA/TRI April 2012(04-12). 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 OA requirements. 10. QUAUTYASSURANCE ENTITY: PRI Construction Materials Technologies, LLC.—QUA9110; (813)621-5777 -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report E39330.11.11-2-R4 Certificate ofAuthorization#9503 F1.7804-119 Revision 4:04/18/2016 Page 6 of 6