EVALUATION REPORT
East Coast Metals,Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-114
Hialeah,FL 33010 Date of Issuance:09/03/2008
Revision 4:03/17/2015
SCOPE:
k This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
-herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
tsrtvuu,,
tr
^ The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. ���FSFc' q�C P.E.on 03/17/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 t:•.,��0 ;�E�s`Y' document.Signed,sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by ar ;company manufacturing or distributing products It evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I�RINIIY,ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals,as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard year
1507.3.7 Installation,non-HVHZ FRSA/TRI April 2012(04-12) 2012
1518.8.1 Installation,HVHZ RAS 118,119&120 1995
1523.65.2.2 Static Uplift Resistance TAS 101 1995
1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015
Florida TEC(TST7393) TAS 101 S1G-628R 10/27/2010
PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001 =
PRI(TST5878) TAS 101 ECM-003-02-01 06/1312GDB
PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008 i
PRI(TST5878) TAS 101 ECM-006-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008
Florida Building Code Attachment Requirements FRSA/TRI April 2012(04-12) 04/2012
Florida Building Code-HVHZ Attachment Requirements RAS 118,119 and 120 1995
East Coast Metals - Metal Quality Mill Certifications Various
Architectural Testing(QUA1844) Quality Control Participation Letter Exp.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre-formed metal channel _
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof file adhesive.
Hip&Ridge Channel Metal is available in 119-3/8-inch L
3/8-inch)length by 2.5,3,3.5,4,5,6 or 7-inch L 3/8-inch)
heights with 1.S-inch L 1/16-inch)deck-flanges.
i
i
s
Exterior Research and Design,MC. Evaluation Report E10240.08.08-R4
C.ertf/lcate ofAuthodru on M03
FL5374-R4
Revision 4:03/17/2015
Page 2 of 7
I
t
TRINITY'ERD
4.2 Trim Lock Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for Interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8")length by 3, 3.5, 4, 5 or 6-inch(±3/8-inch) heights
with 1.5-inch(±1/16-Inch)deck-flanges.
O
r
4.2 Trim Lock Plus Channel Metal:Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and ,;f�
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation i
atop the roof underlayment via placement in FBC
4v/y
Approved roof tile adhesive, which flows-through and -;�. � ;'rvj"
interlocks with the underlying adhesive. ;%c
Trim Lock Plus Channel Metal is available in 119-3/8-inch
i (±3/8")length by 3,3.5,4,5 or 6-inch(±3/8-inch)heights
with 1.5-inch(±1/16-inch)deck-flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min.0.019±0.002inch,ASTM A653(G-90),min.33 KSI.
➢ Galvalume Steel: Min.0.019±0.002-inch,ASTM A792,AZ55,min.35 KSI.
➢ Aluminum: Min.0.032±0.002-inch,ASTM 8209,3003-H14,min.21 KSI.
• ➢ Stainless Steel: Min.0.019±0.002-inch,ASTM A2401A48O,T3O4,min.35 KSI.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design,UC. Evaluation Report E10240.08.08-R4
Certl/lcate o/Authorization#9503 Ft5374-R4
Revision 4:03/17/2015
Page 3 of 7
i
t
i
' RINIT T I
ERD I�
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118,119 and
120,and the data in Tables 1A and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance(Mr)or uplift resistance(Fr),
as determined in accordance with RAS 127,not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
> "INDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. 1:1!s method is limited to 2-part tile adhesives. Allowable
performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance. `
> "INTERDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE IA: PERFORMANCE LIMITATIONS-HVHZ,INDEPENDENT PADDY PLACEMENT '
(2 TO I MARGIN OFSAFETYALREADYAPPUED)
Hip/Ridge Metal Adhesive Allowable Performance _
Tile Moment Based Uplift Based
Design Metal Type Type Placement Mr(ft-Ibf) V(Ibf)
Hip&Ridge galvanized clay or 3M'"2-Component Foam Independent 127 169 I
Channel Metal concrete Roof Tile Adhesive AH-160
Trim Lock galvanized,Galvalume®, clay or 3M1 2-Component Foam Independent 171 159 .
aluminum or stainless steel concrete Roof Tile AdhesiveAH-160
Trim Lock Plus galvanized,Galvalume®, clay or 310-2-Component Foam Independent 177 165
aluminum or stainless steel concrete Roof Tile Adhesive AH-160
TABLE 113: PERFORMANCE LIMITATIONS-HVHZ,INTERDEPENDENT PADDY PLACEMENT
(4 TO MARGIN OFSAFETYALREADYAPPOED)
Hip/Ridge Metal Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design Metal Type Type Placement Mr(ft-Ibf) F'(Ibf)
Trim Lock or Trim galvanized,Galvalume®, clay or 31VITM 2-Component Foam Interdependent 95 88
Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160
Trim Lock galvanized,Galvalume®, clay or 3Mr"Roof Tile Adhesive Interdependent 99 94
stainless steel concrete RTA-1
Trim Lock aluminum clay or 31V1TM Foam Roof Tile Interdependent 90 84
concrete Adhesive RTA-1
Trim Lock Plus galvanized,Galvalume®, clay or 3MTM Foam Roof Tile Interdependent 90 84
aluminum or stainless steel concrete Adhesive RTA-1
Trim Lock galvanized,Galvalume°or clay or TILE BOND"'Roof Tile Interdependent 123 117
stainless steel concrete Adhesive
Trim Lock aluminum clay or TILE BOND"Roof Tile Interdependent 79 73
concrete Adhesive
Trim Lock Plus galvanized,Galvalume®, clay or TILE BOND"Roof Tile Interdependent 79 73
aluminum or stainless steel concrete Adhesive - -
Trim Lock galvanized,Galvalume®or clay or Touch'n Seal StormBond Interdependent 146 139
stainless steel concrete Roof Tile Adhesive
Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54
concrete Roof Tile Adhesive
Trim Lock Plus galvanized,Galvalume®, clay or Touch'n Seal StormBond Interdependent 58 54
aluminum or stainless steel concrete Roof Tile Adhesive
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 4 of 7
. I
TRINITY!ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal,refer to FRSA/TRI April 2012(04-12). For Trim Lock Plus
Channel Metal,refer to the installation instructions herein
5.3.2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined in
accordance with Table lA of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own,single
foam paddy;tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
-TABLE 2A:PERFORMANCE UMFTATIONS—NON-HVHZ,INDEPENDENi PADDY PLACEMENT
(2TO1 MARGIN.OFSAFETYALREADYAPPIIED)
Hip/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type Type Placement lPsq
Hip&Ridge clay or 3M1"2-Component Foam Roof
galvanized Independent 169
Channel Metal concrete Tile Adhesive AH-160
Trim Lock galvanized,Galvalume®,aluminum or clay or 3M'"2-Component Foam Roof Independent 173
stainless steel concrete Tile Adhesive AH-160
Trim Lock Plus galvanized,Galvalume®,aluminum or clay or 3MT'2-Component Foam Roof Independent 178
stainless steel concrete Tile Adhesive AH-160
TABLE 28: PERFORMANCE LIMITATIONS—NON-HVHZ,INTERDEPENDENT PADDY PLACEMENT
(4 TO 1 MARGIN Of SAFETYALREADYAPPLIED)
Hip/Ridge Metal Adhesive Allowable Uplift
Design Metal Type Tile Type Placement (PSf)
Trim Lock or Trim galvanized,Galvalume°,aluminum or clay or 3M'"2-Component Foam Roof
Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98
Trim Lock galvanized,Galvalume®orstainless clay or 3M-Foam Roof Tile Adhesive Interdependent 110
steel concrete RTA-1
y Trim Lock aluminum clay or 3M"Foam Roof Tile Adhesive Interdependent 93
concrete RTA-1
Trim Lock Plus galvanized,Galvalume",aluminum or clay or 3M1 Foam Roof Tile Adhesive Interdependent 93
stainless steel concrete RTA-1
Trim Lock galvanized,Galvalume®or stainless clay or TILE BOND"Roof Tile Adhesive Interdependent 152
steel concrete
Trim Lock aluminum clay or TILE BOND"Roof Tile Adhesive Interdependent 82
concrete
galvanized,Galvalume®,aluminum or clay or
Trim Lock Plus o TILE BOND'"Roof Tile Adhesive Interdependent 82
stainless steel concrete
Trim Lock galvanized,Galvalume®or stainless clay or Touch'n Seal StormBond Roof Interdependent 148
steel concrete Tile Adhesive
Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61
concrete Tile Adhesive
galvanized,Galvalume®,aluminum or clay or Touch'n Seal StormBond Roof Interdependent 61
Trim Lock Plus stainless steel concrete Tile Adhesive P
Exterior Research and Design,LLG Evaluation Report E30240.08.08-R4
certglcote of Aurhortmtlon#9503 FL5374-R4
Revision 4:03/17/2015
Page 5 of 7
I
.�TRINI-iY ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood(non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip&Ridge Channel Metal and Trim Lock Channel Metal shall be Installed using min. 11 ga.x IX-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck-flanges. Fasteners shall be
positioned%-inch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to
FBC RAS 118,Drawing 13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3.
6.3 Trim Lock Pius Channel Metal shall be installed atop the'Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet =
adhesive and allow it to set-up prior to installation of roof T Us.
,ice i
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal,the tile adhesive and the underlayment is not
disturbed prior to or during placement ofthe ridge tiles. '
6.3.2 Approved underlayments are the codified'30/90'system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certfftcate of Authorizatlon#9503 FLS374-R4
Revision 4:03/17/2015
Page 6 of 7
c t
A
•i TRINI-ry l ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved,published
installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118,RAS 119,RAS 120 requirements.
- Hip/Ridge Tile
' � Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
41
View of Trim Lock Plus Channel Metal Installation after Weather Blacked
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
a. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing,Inc. —QUA1844;(717)764-7700
-END OF EVALUATION REPORT-