Loading...
HomeMy WebLinkAboutCompaction Test r 64 TP 01, f ` File Copy Z%NJAVjL KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377, SEBAS'TIAN, FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED June 23, 2017 KSM JOB# : 171977-1d/MH/ct PERMIT# 1704-0066 1704-0166 CONTRACTOR South Florida Aluminum Products EC IE— JOB LOCATION 7904 McClintock Way JUL -3 2017 Savannah Club Port St. Lucie, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.W. 0" - 12" 50 104.4 107.3 97.3 2. S.E. 50 104.3 97.2 Soil Description: Brown Sand 108.0 - I I I I I In Place Moisture: W I I I I I 9.2 Percent E I I I I I I I I I I Optimum Moisture: H 107.0 12.2 Percent T I I I I I I I I I Max. Dry Density: P I I I I I 107.3 P.C.F. 106.0 .....' C I I I I I @ Test Locations The I I I I I Density & Penetrometer F I I I I Readings Indicate the 105.0 L — Degree of Compaction Meets D I I I I I I Minimum Required R I for alit$&,oa f_f n Y I I I I I I * R 9i . 4 to Natural Grade. I I I I I e >✓° ; � t e sue: 9 10 11 12 13 14 15 ® No 1 m _ _ Moisture-% of Dry Weight lieE E. ; �y man i�gFclounty Building Department e bflalum.com .egaoerae2ipa�� Ronald G. Keller, P.E.:37293/SI Lic. No.: 860 / Julie E. Keller, P.E.:68366