HomeMy WebLinkAboutBuildinbg Permit-All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED _ 5
Date: 13 May 2021 Permit Number:
RECEIVED
p MAY 2 0 2021
Building Permit Application permitting Department
Planning and Development Services St. Lucie Countv
Building and Code Regulation Division Commercial Residential X
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT APPLICATION FOR: Exterior Door
PROPOSED IMPROVEMENT LOCATION:
Address: 7805 Banyan Street Ft. Pierce, FL
Property Tax I D #: 1301-603-0080-000-1 Lot No.19
Site Plan Name: Block No. 19
Project Name:
DETAILED DESCRIPTION OF WORK:
Remove and Replace Exterior Front Door
New Electrical Meter Second Electrical Meter
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
_Mechanical _ Gas Tank _ Gas Piping _ Shutters
_ Electric _ Plumbing
Total Sq. Ft of Construction: 1758
Cost of Construction: $ $500.00
Sprinklers _ Generator
Windows/Doors _ Pond
Roof Pitch
Sq. Ft. of First Floor: 864
Utilities: _ Sewer _ Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:-
Name Kimberly Kimberly Wagner
Name: Laura Young
Address:7805 Banyan Street t
Company:SteveNSons Construction, LLC
City: Ft. Pierce State: _
Zip Code: Fax:
Phone No.772-607-0135
Address:889 SW General Patton Terrace
City: Port Saint Lucie State: FL
Zip Code: 34953 Fax:
Phone N0586-612-7881
E-Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail stevensonsconstruction@yahoo.com
State or County License CBC1258089
If value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
City: State:
Zip: Phone
Address:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
BONDING COMPANY: Not Applicable
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attornev before commencing work or recording vour Notice of Commencement.
Signa f Owner/ Lessee/Contrs Agent for Owner Signature of
STATE OF FLORIDA �.
COUNTY OF
Swoyn to (or affirmed) and subscribed before me of
' Physical Presence or Online Notarization
this Z_ day of M&k 1 2020 by
Name of person making statem .
Personally Known OR Produced Identification
Type of Identification
Produced
(Signature of Notary Public- tidtory Public • State of Flor
Commission # GG 981439
h CAfm. Expires Apr 23, 21
Commission No.-_gcnd�� tRFbugh National Notary A
REVIEWS FRONT I ZONING
COUNTER REVIEW
DATE
RECEIVED
DATE
COMPLETED
STATE OF FLORIDA
COUNTY OF
Sn to (or affirmed) and subscribed before me of
7Phyysical Presence or Online Notarization
this L day of at, 2029- by
AA
Name of person making statement-.--,
Personally Known -1-1 OR Produced Identification
Type of Identification
Produced
- Vk�
•&
4(gnature of Notary Public- State of to �. 4notary Public - State o lorida
6 93) j� 2 9 P` Commission # GG 8 39
mmission No. ((J "' al my Comm. Expires A r 2024
on ed through National Not, y Assr.
SUPERVISOR I PLANS I VEGETATION SEA TURTLE I MANGROVE
REVIEW I REVIEW I RE I REVIEW REVIEW
5/11/2021
Florida Building Code Online
Professional Regulation
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Fads Publications Contact Us BCIS Site Map Links Search
c User
dbpr
409.1
RECEIVED
USER: Publ;Approval
MAY 18 2021
Product Approval Menu > Product or Application Search > Application List > Application Detail Permitting Department
St. Lucie County
FL # FL22513-R3
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800)663-3667
sschreiber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
TAS 202
TAS 203
Method 1 Option A
Year
1994
1994
1994
Date Submitted 11/06/2020
Date Validated 11/09/2020
Date Pending FBC Approval
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH I%2bvKq HKCWn2WNgFPQkSTNA%3d%3d
1/3
5/11/2021 Florida Building Code Online
Date Approved 11/17/2020
Summary of Products
FL # Model, Number or Name
Description
22513.1 HPC Wood -edge Steel Side -Hinged
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Door Unit
Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.01-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
06/30/2025
Design Pressure: +50/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0212.pd
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6'-8" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system is required.
FL22513 R3 AE 514008B.pd
Door top rails stamped "HPC". See DWG-MA-FL0212 for details.
Created by Independent Third Party: Yes
22513.2 Wood -edge Steel Side -Hinged Door
8'-0" Opaque I/S or O/S Single Door Unit
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +70/-70
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pdf
Building Code, including the High Velocity Hurricane Zone, and
! Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 3'-O" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system not
FL22513 R3 AE 514009B.12d
required. See DWG-MA-FL0215 for details.
Created by Independent Third Party: Yes
22513.3 Wood -edge Steel Side -Hinged Door
8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +45/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pd
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system not required
FL22513 R3 AE 514007B.pd
on opaque panels, but is required on glazed sidelites. See
Created by Independent Third Party: Yes
DWG-MA-FL0215 for details.
22513.4
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Wood -edge Steel Side -Hinged Door
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +50/-45
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system not required
FL22513 R3 AE 514007B.pdf
on opaque panels, but is required on glazed sidelites. See
Created by Independent Third Party: Yes
DWG-MA-FL0215 for details.
22513.5 —�
Wood -edge Steel Side -Hinged Door
8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit
w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC 1\1I013747.06-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
06/30/2025
Design Pressure: +40/-40
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
! FL22513 R3 II FL0217.pdf
Building Code, including the High Velocity Hurricane Zone, and
!, Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system is required.
FL22513 R3 AE 514007B.pdf
See DWG-MA-FL0217 for details.
Created by Independent Third Party: Yes
-
22513.6 Wood -edge Steel Side -Hinged Door
6'-8" Opaque I/S or O/S Single Door
https:/Moridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 2/3
5/11/2021
Florida Building Code Online
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. Y-0" x 6'-8" max nominal size. When impact
resistance is required, hurricane protective system not
required. See DWG-MA-FL0211 for details.
22513.7 Wood -edge Steel Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55/-55
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. When impact
resistance is required, hurricane protective system not required
on opaque panels, but is required on glazed sidelites. See
DWG-MA-FL0211 for details.
22513.8 Wood -edge Steel Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. When impact
resistance is required, hurricane protective system is required.
See DWG-MA-FL0214 for details.
Certification Agency Certificate
FL22513 R3 C CAC NIO13747-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513 R3 II FL0211.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513 R3 AE 514010B.pd
Created by Independent Third Party: Yes
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22513 R3 C CAC N1013747-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513 R3 II FL021l.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513 R3 AE 514008B.pdf
Created by Independent Third Party: Yes
6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Certification Agency Certificate
FL22513 R3 C CAC NIO13747.03-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513 R3 II FL0214.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513 R3 AE 514008B.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. _QRght 2007-2013 Stale of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH I%2bvKgHKCWn2W NgFPQkSTNA%3d%3d
3/3
NOTICE OF PRODUCT CERTIFICATION
CERTIf
Q A�.6CCkk,V
Company: Masonite International Corporation Certification No.: NI013747.03-R2
1955 Powis Road Certification Date: 06/08/2017
N
West Chicago, IL 60185 Expiration Date: 06/30/2025
x
Revision Date: 07/27/2020
Product: Wood -Edge Steel 3/4-Lite or Less Glazed Inswing or Outswing Door w/Full-Lite or Less Non -Impact
°�"'�
Rated Sidelites (w/Wood Frame unless noted)
0
Specification: TAS 202-94/ASTM E330-02
Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the
applicable specification and that all certification
criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's Certification
Program is accredited by The American National
Standards Institute (ANSI).
Inswing
Glazed
Structural
Water
Test Report Number
Configuration
or
or
Maximum
Design
Test
Drawing Number &
Outswin
O a zee
Size
Pressure
Pressure
Comments
X
I/S
Glazcd
3'0" x 6'8"
+50/-50
0 psf
NCTL- 110- 19469-1
Single
3/4-Lite Max
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0214-17
X
O/S
Glazed
3'0" x 6'8"
+50/-50
3.0 psf
NCTL-110-19469-1/W-1857
Single
3/4-Lite Max
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50 pal,3•4.5
AnchorDetails-DWG-MA-FL0214-17
X
I/S
Glazed
3'0" x 6'8"
+501-50
0 psf
NCTL-210-3461-1/W-1957
Single
Ventlite
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0214-07
X
O/S
Glazed
3'0" x 6'8"
+50/-50
0 psf
NCTL-210-3461-1/W-1857
Single
Ventlite
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FLA214-07
XX
I/S
Glazed
6'0" x 6'8"
+501-50
0 psf
NCTL -110-19469-1
Double
3/4-Lice Max
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0214-17
XX
O/S
Glazed
6'0" x 6'8"
+50/-50
3.0 psf'
NCTL-110-19469-1
Double
3/4-Lite Max
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50psf'
AnchorDeWls-DWG-MA-FLA214-17
XO/OX
I/S
Glazed
6'0" x 6'8"
+50/-50
0 psf
NCTI.110-19469-1
Single w/Sidelite
3/4-Lite Max Door
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
Anchor Details-DWG-MA-FL0214-17
XO/OX
O/S
Glazed
6'0" x 6'8"
+50/-50
3.0 psf'
NCTL-110-19469-1
Single w/Sidelite
3/4-Lite Max Door
4.5 psf'
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
7.50 psf'
Anchor Details-DWG-MA-FL0214-17
OXO
I/S
Glazed
910" x 6'8"
+50/-50
0 psf
NCTL-110-19469-1
Single w/Sidelites
3/4-Lite Max Door
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
Anchor Details-DWG-MA-FLA214-17
OXO
O/S
Glazed
910" x 6'8"
+50/-50
3.0 psf'
NCrL-110-19469-1
Single w/Sidelites
3/4-Lice Max Door
4.5 psf'
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
7.50 psf'
Anchor Details-DWG-MA-FL0214-17
OXXO
I/S
Glazed
12'4" x 6'8"
+501-50
0 psf
NCI'L-110-19469-1
Double w/Sidelites
3/4-Lite Max Door
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
Anchor Details-DWG-MA-FL0214-17
WOW
O/S
Glazed
12'4" x 6'8"
+50/-50
3.0 psf'
NCI'L-I10-19469-1
Double w/Sidelites
3/4-Lite Max Door
4.5 psf'
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Full-Lite Max S/L
7.50 psf'
Anchor Details-DWG-MA-FLA214-17
. -mats Bumper Outswing Threshold 2 -Denotes Z-Serles Outndug Threshold 3-HI-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outswing Threshold
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE: ��i/
In
n1MASONITC. '49"MAX. OVERALL FRAAfE MOTH -� DO
boo
21" MAX 35.375" MAX.0
3/4-LITE WOOD -EDGE STEEL DOOR UNIT G-- PANEL WIDTH 2D. MAX� 37.5" MAX. Q O
D.L.O. D.L.O. CY J
6'-8" DOUBLE DOOR WITH /WITHOUT SIDEL/TES � W/A57RAGAC FRAME WIDTH
!
GENERAL NOTES I 4 U
i, EVALUATED FOR USE IN LOCATIONS ADHERING TO I '
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM i
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED. ^ Z
2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), °p w
HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. I ' ••-I ^ (,/')
1^� LJ
WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, -j v
LJ
HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. ?ci W
4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 z
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. V) I�
5. PLASTICS TESTING: I I a
TEST DESCRIPTION DESIGNATION LITE FRAME 'S U
!i SELF IGNITION TEMP ASTM D1929 _740 'F > 650 'F
RATE OF BURNING ASTM D635 0.77 IN MINrl
SMOKE DENSITY IASTM D2843 13.4X 3
TENSILE STRENGTH- I ASTM D638 7.IX DIFF
• COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
45M HOURS XENON ARC METHOD 1 I
DOUBLE DOOR UNIT W/ ID ITS r o
■
I
■ ■' ■■', ' ■I ■ ■ ■ ■I ■ '■ 11 ''
■■ ■■:
r�r: . � rrr: .! • I r• - ►rr: i .. - •fir- �
DESIGN PRESSURE RATING
WATER INFILTRATION PERFORMANCE IS
WHEREREQUIRED TO BE 15% OF DESIGN PRESSURE
CONFIG MAX WIDTH
INSWING
I OUTSWING
INSWING BUMPER 0 S
I Z-SERIES O S
HIGH DAM O S
T4 O S
HP
OAAAA
7.5
+50.0 -50.0
+50.0 -50.0
N A 2 . -20.0
+30.0 -30.0
+50.-50.0
+50.0 -50.0
-X
0-
XX 74
+50-00
-00
+
N A 20.0 -20.0
+30.0 -30.0
+50.0 - 0.
A
.0
0% or XO 75
+500
+50.0
.
..
.50
RN
+50.0 -50.0
+50.0 -50.0
6-11+
+0. 2
2
30.0 -30.0
+50.0 -5.0
N/A
I
OX 112.5
X%0 49
.
N A 20.0
-
+50.0 -50.0
NA
�
-50.0
++00 --
.
N A N/A
N h
N A
N A
N A
SCALE- N. T. S.
Aft"" i �"'r DWG. BY: SWS
TABLE OF CONTENTS �/���
SHEET / DESCRIPTION C//�'f �J}� CNK. BY:
KURT BALTHAZOR DRAWN NO:
1 TYPICAL ELEVATIONS &GENE NOT S FLORIDA P.E. DWG-MA-Ro214-I
2 ANCHORING IOCATICNS & DETAILS /5653J
3 ANCHORING LOCATIONS & DETAILS
-- _... SHEET 1. OF _3
.j 6"3� SE_' DETAIL3.
3" 3• B 3 C
SEE DETAIL
'C'
IY`
3•
'l -
B
O
� i
6-
6•
6 3•
6•
I I
I I
I
3' -� k
#8 x 2"
#8 x 2"
DETAIL
1
1.375'
T
INSWING THRESHOLD
1. 2
T
Z—SERIES 0/5 THRESHO n
t ' I I _ E 3'
I'�I L 3
3'
6'
SEE DETAIL
'F'
#10 x 5/8"
#10 x 5/8"
#10 x 2-1/2" #10 x 1"
#10 x 1"
#10 x 5/8"
DETAIL "C"
0.962i
T
BUMPER O/S THRESHOLD
aj+1 047-
!JlQH •A, •THRESHOLD
J L- c-
#8 x 2"
DETAIL "E" ASTRAGAL
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
AS SHOWN.
`I MWIRL
QYS THRESHOI
1.437" FFV-�
T
HP OAS THRESHOLD
HOT ,ELT
ASTRAGAL RETAINER BOLT HOLE
MUST BE DRILLED THROUGH
THE THRESHOLD & INTO THE
STRUCTURE DEEP ENOUGH
FOR A 1.375" THROW
DETAIL "F" ASTRAGAL
/6 X 1-1/2' PHS
HOT MELT /' •.••P"'y 1/2• BITE B/dlfllbWild I
EUSTOMER 7`•�
:: �T4y %1i�L
FXTFRIQ'
TYPICAL GLAZING DETAIL
NON —IMPACT GLASS
DATE: 512617 7
SCAB N.T.S.
owc. BY: SINS
" e
DRAWING HO.:
DWG-MA-FLO214-17
6HEET 2 a 3
ATTACHMENT DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY ROBERTO LOMAS, PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
#10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2".
WOOD SCREW EDGE DISTANCE MIN 3/4".
3" -
1
�
I
I
o
N
p
W
<
U
i
a SEE DETAIL
n "D' SHT. 2
Q
O
3-7
W
K
yl
ui
a G
io
i
3' -
MIN t
— MAX"
SHIM
CL —I �—
:ra
TYPICAL MASONRY
ANCHOR INSTALLATION
2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE
MINIMUM EMBEDMENT OF 1-1/4".
3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE,
4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS.
6 --
3"
6'
3'
3
3
_
� p
W
6
En
W
� If
G H
II II
9
II li.
W B
10
3"6tW—
6" -
3. , 3"
6"
6'
HARDWARE SCHEDULE
1.. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED
AT 5-1/2" CENTERLINE,
2. 4" X 4" FULL MORTISE BUTT HINGES.
1"X112" CORRUGATED #10X2" WOOD SCREW
3" FROM EACH END 6" FROM EACH END
AND 7' OC AND 12" OC
,
ALCAEX RTC
CAULK
ACRYLIC
LATEX —
CAULK CL
s COMBINATION WOOD COMBINATION WOOD
150 MULLION (BOXED) MULLION (BOXED) MIN
MAX"
SHIM
CL —)—;
TYPICAL WOOD BUCK
ANCHOR INSTALLATION
(3WO D SCREWS"
EACH END
INTEGRAL WOOD
MULLION (CHS)
."n
n 00
cc
Q (o
.J Q
ct� —
O
Q Q
a =
Ln U
z Ln F
N. r. S.
SWS
axc. er:
Druwi�x No.:
DWG-MA-Ft0214-}7
or