HomeMy WebLinkAboutConstruction Plans25'-0" 12'-42" 2'-6" 5'-2 WINDOW 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2, THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM Al003/A1003M-15. 5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD• FRAMING CONNECTIONS SECURED WITH #12-140/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED, NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. SUB —GRADE SOILS: —TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2020 FLORIDA BUILDING CODE, 7TH EDITION —BOTTOM OF CONCRETE FOOTING SHALL BE MINIMUM OF 12" BELOW UNDISTURBED OR ENGINEERED GRADE MNQREIE—MINI U V 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. —COVER: —3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1}" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION- -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. J"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN.-- N-- ABASE RAIL 3' — 0" SWINGING —-� ' L2,500 PSI 4" CONCRE SLAB WITH 1 OGA. W.w OR FIBER MESH �12" (2) #5 REBAR ® 6" O.C. MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 500 PSF(TYP.) 25" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL 2 5" PLAN VIEW DOOR FRAMING J" RECESS 4" OOR WIDTH ELEVATION VIEW DOOR FRAMING—-, IL T RECESS 75"J 4" OOR WIDT OPTIONAL ROLL —UP DOOR ;ONCRETE SPLASH —GUARD RECESS MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER ROLL —+UP DOOR i i i i i i i i i 12"x12" REINFORCED FOOTER 1 0 I 14a CODE VERSION fHC 2020 7th Edition, ASCE-7-16 ANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE (OCCUPANCY (UTILITY, U �I WIND SPEED Vult-150mph ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. + — 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD tOPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 500 SQ. FT. MTB 4/4/21 370 SmallWood Ave, Fort Pierce I" 25'L X 20-W X 12-H II 0 LL I w 4/6/21 z MottheW T. BaldWin P.E. Q Florida License #64608 Sheet: CA-1 OF 4 F _ t x c� J 0 N 12 3� —1 —1 _0„ ROLL —UP DOOR 0l = c� = J o N ANYME E CODE INFOR ATION CODE VERSION FBC 2020 7th Edition, ASCE-7-16 ANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED - Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1500 SQ. FT. REVISIONS REV DESCRIPTON DATE BY r- 2 —10j" 2'-10i' j 20'-0" FRONT END WALL _ '-11$" _11$" �4'—t tg" 20'-0" REAR END WALL -4-113. w x J O I iV w x J O I iV DRAWN BY: MTB DATE. 4/4/21 O.C. MAX. O.C. MAX. 12,- 1" tocAnoN,370 Smallwood Ave, Fort Pierce SIZE. 251 X 20'W X 12'H U]I Ld > 0 Z Q SWINGING J DOOR 2'-6" f0 WINDOW l N —11j" —111" —11j" —11 —112" 25'-0" LEFT SIDE WALL 25'-0" RIGHT SIDE WALL LL-112" 0 z w L1J Cf) 4/6/21 MattheW T. BaldWin P.E. Florida License #64608 Sheet: CA-2 OF 4 { CODE INFORMATION CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U F- WIND SPEED Vult-150mph 0 EXPOSURE B w w ENCLOSURE ENCLOSED DOOR INTERNAL PRESSURE COEFF. +/— 0.18 J J IMPORTANCE FACTOR 1.0 0 o ROOF DEAD LOAD 10PSF I I ROOF LIVE LOAD 20PSF OR 3001b P.L. a NFLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE No HURRICANE SHELTER USAGE No SQUARE FOOTAGE 500 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 20'-0" _I 20'-0" _I FRONT END WALL REAR END WALL DRAWN BY: MTB DATE: 4/4/21 LoCAnoN:370 Smallwood Ave, Fort Pierce SIZE. 251 X 20'W X 12'H FL F- x x c� CD uj x x J J WINDOW 0 0 I I N N SWINGING DOOR (n 25'-0" I 25'-0" I W LEFT SIDE WALL RIGHT SIDE WALL � 0 z w 4/6/21 Matthew T. BaldWin P.E. W Florida License #64608 0 C U) Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM s" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SECURED TO WALL POST WITH (4)#12-14)4" SELF —DRILLING (4)#12-14)j" SELF —DRILLING SECURED TO WALL POST WITH SCREWS SCREWS (4)#12-14xj" SELF —DRILLING NIPPLE TO 2"x2"x2" 16 GA. ANGLE CLIP 2"x2"x2" 16 GA. ANGLE CLIP SCREWS z BASE RAIL NIPPLE TO f " . SECURED WITH (4) #12-14 SELFSECURDRILLED WIING TH SCREWS-14 t BASE RAI SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CLIP CODE INFORMATION _ — SECURED WITH (4) #12-14 SINGLE OR DOUBLETS CODE VERSION FBC 2020 7th Edition i I 1-1 1-1 I —III —I I- I I I i I I —I I —III —I I —III- I SELF —DRILLING SCREWS HEADER SINGLE OR DOUBLETS ASCE-7-16 =1 I ;III 11-1 I I- I =1 I —I I —I 11-1 I i NIPPLE T HEADER MANUFACTURER CARPORTS ANYWHERE �— BASE RAI" �" BUILDING TYPE UTILITY STRUCTURE INTERMEDIATE POST TO CONSTRUCTION TYPE II-e RISK CATEGORY I POST TO BASE RAIL END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION HEADER CONNECTION DETAIL FIRE PROTECTION NONE CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 OPTION 2 FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph 2"x2"x2" 16 GA. ANGLE CLIP SECURED EXPOSURE B WITH (4) #12-14xj" SELF —DRILLING ENCLOSURE ENCLOSED SCREWS 26 GAUGE ROOF SHEATHING INTERNAL PRESSURE COEFF. + — 0.18 VARIES SECURED WITH (1)#12-14xj" ;N6 SELF—DRILLING SCREWS ® IMPORTANCE FACTOR 1.0 T'2-1-2-1' (6" O.C. (9" O.C. MAX.)) ROOF DEAD LOAD tOPSF STD. MAX. SPACING-4ROOF LIVE LOAD 0PSF OR 3001b P.L. 2"x2"x2" 16 GA. " TS r FLOOR DEAD LOAD 1OPSF ANGLE CLIP 3MIN. SECURED WITH (4) IPPLE NIPPE. NO WALLFLOOR LIVE LOAD 50PSF #12-14x4" "R"RATING OF WALLS,FLOOR,ROOF N/A SELF —DRILLING x4" - MODULES PER BUILDING 1 SCREWS LING NEL HURRICANE PROTECTION USAGE NO STD. MAX. SP CING SCREWS 48" O.C. 16 GEMAX. SECURED FURRING NWITH HURRICANE SHELTER USAGE NO N VARIES (2)#12-14x1" SELF —DRILLING SQUARE FOOTAGE 1500 SQ. FT. SCREWS TO EACH RAFTER. REVISIONS NON—STRUCTURAL SIDE WALL ROLL —UP REV DESCRIPTON DATE BY HEADER OR WINDOW DOOR/FRAME OUT POST TO TRUSS ROOF PANEL CONNECTION RAIL TO POST DETAIL HEADER DETAIL CONNECTION VERTICAL SHEATHING OPTION INSTALL PER MANUFACTURERS INSTRUCTIONSrR TO # 14xi " " 16 GA. #12-14x4" SELF—DRILLINGANNEL BRACE, MIN. SELF —DRILLING SCREWS SCREWS ® 6" O.C. UP TO 7' POST, MIN °RA N er: ® 10" O.C. MAX., 3" MAX. & 6" MAX.OVER 7' POST. MIN.MTB MAX. FROM CORNERS FROM CORNERSO MAX. 60' FROM °A�` 4/4/21 HORIZONTALLY/ 4" MAX. Z. EXCLUDEFROM CORNERS (LocAMON: VERTICALLY WALLS). SECURED 370 SmallWood Ave, Fort Pierce INTERIOR I�(4)#12-14x" sizE 25'L X 20'W X 12'H EXTERIOR —DRILLING SCREWS.MINIMUM 6TS NIPPLE. NIPPLE 2 SECURED TO WALL POST WITH 4 12-14 " SELF —DRILLING DOOR FRAME TO POST SCREWS CONNECTION ROLL —UP DOOR TO BOX EAVE RAFTER TO POST CONNECTION POST CONNECTION DETAIL Enclosed Design Pressures - - 150 mph Basic Wi nd Speed Zone Roof Wal 1 2n 2r 2e 3r 3e 4 5 9.6 12.3 9.6 9.6 14.3 14.3 14.3 17.2 -11.1 -44.6 1 -28.1 -11.1 -61.5 -51.7 -16.0 -21.7 APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 WINDOW MI WINDOWS AND DOORS FL17499.1 MODEL 185 SH V) 4/6/21 J Q Matthew T. Baldwin P.E. Florida License #64608 w LLJ o Sheet- CA-4 OF 4