HomeMy WebLinkAboutProduct Approval; Single Hung WindowsBCLS Home Log In User Reglstratlon I Hot Topics 1'; Submit Surcharge f Stats & Facts ' Publlcatfons I Contact Us BOS Sita heap Unks i Search .I
a .
Product Approval
Floridre USERrPubllcUser
Product An naval Menu > Product or Application Search > &P catlon s > Application Detail
MIN'. s;FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
PL17499-R8 p, —1Imo! 9 q — X
Revision ! 1 1 (�
2020
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
MI Windows and Doors
650 West Market Street
Gratz, PA 17030
(717)365-3300 Ext2560
bsitlinger@miwd.com
Brent Sitlinger
bsitlinger@miwd.com
Windows
Single Hung
Certification Mark or Listing
American Architectural Manufacturers Association
Steven M. Urich, PE .
Validation Checklist - Hardcopy Received
Standard Year
AAMA 506 2016
AAMA/WDMA/CSA 101/I.S.2/A440 2008
AAMA/WDMA/CSA 101/I.S.2/A440 2011
Method 1 Option A
11/17/2020
11/17/2020
Summary of Products
FL #
f4odel,.'Number or Name
Description
17499.1
185 SW
36x84 Fin/Flange Frame IG/SG Impact Single Hung
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: No
FL17499 118 C CAC APC (13278) 185 SH (01 1723),pdf
Approved for use outside HVHZ: Yes
FL17499 R8 C CAC APC (13 79) 185 SH 101723 ,pdf
Impact Resistant: Yes
FL17499 R8 C CAC APC (13280) 185 SH l 017 ,pdf
Design Pressure: +55/-55
FL17499 R8 C CAC APC t13292)_185 SH (101723),pdf
Other: R-PG55*, Missile Level D, Wind Zone 3. Glass to be
Quality Assurance Contract Expiration Date
bedded In Pecora 896 sealant.
10/17/2023
Installation Instructions
FL17499 RS II 08-02545B1.pdE
Verified By: Luis R Lomas PE-62514
Created by Independent Third Parry: Yes
Evaluation Reports
FL17499 R8 AE 513321E-3.pdf
Created by Independent Third Party: Yes
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 R8 C CAC APC (13269) 185 SH (00823),pdp�f
Approved for use outside HVHZ: Yes FL17499 R8 C CAC APC ( 31 270) 185 S 00823 ,pdf
Impact Resistant: No FL17499 R8 C CAC APC (13271) 185 SH ( 00 23 ,pdf
Design Pressure: +60/-60 FL17499 R8 C CAC APC ( 31 361) 185 SH ( Ol 0823),pdf
Other: R-PG60 Quality Assurance Contract Expiration Date
10/08/2023
Installation Instructions
FL17499 R8 II 08-0254981.odf
Verified By: Luis R Lomas PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 AE 513327B-4.odf
Created by Independent Third Party: Yes
17499.3 185 SH 36x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 RS C CAC APC 13272)185 SH 11017231,RAf
Approved for use outside HVHZ: Yes FL17499 R8 C CAC APC (13273) 185 SH (101723),pdf
Impact Resistant: No FL17499 R8 C CAC APC (13274) 185 SH (101723)odf
Design Pressure: +60/-60 FL17499 R8 C CAC APC (13363) 185 S 1723,pd�
Other. R-PG60* Quality Assurance Contract Expiration Date
10/17/2023
Installation Instructions
FL17499 R8 II 08-0255081.odf
Verified By: Luis R Lomas PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 118 AE 513328E-S.pdf
Created by Independent Third Party: Yes
17499.4 185 SH 36x71 Fin, Finless, Flange Frame IG Single Hung
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 RB C CAC APC H0462.01-109-47-RO 185 SH
Approved for use outside HVHZ: Yes 1042522 Ad
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +60/-67 04/25/2022
Other: R-PG60* Installation Instructions
FL17499 R8 II 08-03163-1.gdf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 AE 514082.odf
Created by Independent Third Party: Yes
17499.5 185 SH 36x72 Fin, Flange, and Finless Frame Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17499 R8 C CAC APC (i 811 1583.02-106-11-RO 185
Approved for use outside HVHZ: Yes SH(061423).odf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +60/-70 06/14/2023
Other,. R-PG60 Installation Instructions
FL17499 R8 II 08-03383.Rdf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 RB AE 514377-nif
Created by Independent Third Party: Yes
17499.6 185 SH 52x62 Fin, Flange,,and Finless Frame, Insulated Glass
Untits of Use :r Certification Agency Certificate ~`
Approved for use in HVHZ: No FL17499 R8 C CAC' APC(178 2 1711.08-106-12 RO 185
Approved for use outside,HVHZ: Yes SH(072723)Aff
Impact Resistant: Yes Quality Assurance Contract Expiration Date
Design Pressure: +50/-63 07/27/2023
Other: R-PG50 Installation Instructions
FL17499 R8 II 08-03379.0AC
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 AE 514373.pd
Created by Independent Third Party: Yes
17499.7
185 SH
52x62 Fin, Flange, and Finless Frame, Insulating Lami Glass
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: No
FL17499 R8 C CAC APC(17813)1711,04-106-12-Ro 185
Approved for use outside HVHZ: Yes
SH(07272 09
Impact Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure: +50/-63
07/27/2023
Other: R-PG50
Installation Instructions
FL17499 R8 II 0-03381.odf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 AE 514375.odf
Created by Independent Third Party: Yes
17499.8
185 SH
36x72 Fin, Flange, Finless Frame, Insulated Glass
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-70
Other: R-PG60, Missile Level D, Wind Zone 3
Certification Agency Certificate
FL17499 R8 C CAC APC(17816)1711.07-106-12-R2 185
SH(061423),pdf
Quality Assurance Contract Expiration Date
06/14/2023
Installation Instructions
FL17499 R8 II 08-03380.pdf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8AE514374.udf
Created by Independent Third Party: Yes
17499.9
185 SH
52x72 Fin/Flange Frame IG/SG Impact Single Hung
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55/-55
Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be
bedded In Pecora 896 sealant.
Certification Agency Certificate
FL17499 R8 C CAC APC (13?75) 185 SH (100823),p
FL17499 R8 C CAC APC (13276) 185 SH (185 SH (`00823 ,pdf
FL17499 R8 C CAC APC (13277) 185 SH(100823 ,pdf
FL17499 R8 C CAC APC (13291) 185 S 100823 ,pdf
Quality Assurance Contract Expiration Date
10/08/2023
Installation Instructions
FL17499
R8 II 08-02544B1 odf
Verified By: Luis R Lomas PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 AE 51332OB-I.pdf
Created by Independent Third Party: Yes
17499.10
185 SH
52x84 Fin/Flange Frame IG/SG Single Hung
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +60/-60
Other: R-PG60
Certification Agency Certificate
FL17499 R8 C CAC APC (132 3) 185 SH (1 09 3),pdf
FL17499 RB C CAC APC (13264) 185 SH (100923),pdf
FL17499 RB C CAC APC (13765) 185 SH (1 09 3)
FL17499 RB C CAC APC ( 336 ) 185 SH (jQq2Z3jpff
Quality Assurance Contract Expiration Date
10/09/2023
Installation Instructions
FL17499 R8 II 08-0254681 odf
Verified By: Luis R Lomas PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 IRS AE 513322E-2.pd�
Created by Independent Third Party: Yes
17499.11
185 Triple SH
111x72 Fin Frame IG/SG Single Hung 11002 Flange Frame
IG/SG Single Hung
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: R-PG50*
Certification Agency Certificate
FL17499 R8 C CAC APC { 31 341) 185 SH TPL (1104231.odf
917499 R8 C CAC APC (13343) 185 SH TPL { 01 212ngdf
EL17499. R8 C CAC APC (13346) 185 SH TPL (10207.31,pdf
FL17499 R8 C CAC APC (31 348) 185 SH TPL (10=,pdfd
Quality Assurance Contract Expiration. Date
10/20/2023
Installation Instructions
E117499 RB Ii 08-0254881 Ddf
Verified By: Luis R Lamas PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
PL17499 R8 AE 513324E-6.gdf
Created by Independent Third Party: Yes
17499.12
118S*TWInSH
106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame
IG/SG Single Hung
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +45/-45
Other: R-PG45
Certification Agency Certificate
FL17499 R8 C CAC APC (13340) 1,85 SH TWN
(1021231,,pdE
FL17499 R8 C CAC APC (3 42 _185 SH TWN
(110423),pdf
FL17499 R8 C CAC APC (13347) 185 SH TWN
(102023),pdf
FL17499 R8 C CAC APC (13349) 185 SH TWN
(1021231.to)
Quality Assurance Contract Expiration Date
10/20/2023
Installation Instructions
FL17499 R8 II 08-02547B1.gdf
Verified By: Luis R Lomas PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17499 R8 ME 513323E-7.pdf
Created by Independent Third Party: Yes
Back Flext
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Cop
Xrlght 2007-2013 State of Florida :: Prlvaev Statement :: Accessiblilty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 650AS7.139S. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The ema8s
provided may be used for official communication with the licensee. However emall addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 45S, F.S., please dick bgtL.
Product Approval Accepts:
M WIN EEl 00591"'1
Credita
safe-
15CCL71'PL�'Mfi1t lGS"
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL,
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TABLE OF CONTENTS
;HEET NO. DESCRIPTION
1 NOTES
2 — 3 ELEVATIONS
4 — 10 INSTALLATION DETAILS
11 COMPONENTS
DESCRIMN -DATE . 4. , APPROYEO
REVISED ANCHOR SPACING & CHARTS 07/11/16•�.61—
B REVISED GIASS 110/02/17 1 R.L
15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
INSTALLATION DETAILS.
17.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF
DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND "
STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT.
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF 0=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (048") FY=33KSI/FU=52KS1 OR
ALUMINUM 6063—TS FU=30KSI .048" THICK MINIMUM
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
NOTES
N.G. I 08-02545
eOALE NTS D"TE 12/09/2014 --1 OF 11
I,W WOODFOR
494d66-0609
SGA►ED. 02/2T/2020
Luis R. Lomas P.E.
FL No.: 62514
36" MAX
FRAME WIDTH
16"
2" MAX
F— 0 C --I —.1
2 MAX
16"
MAX
O.C.
O
MAX
FRAME
HEIGHT
185 ALUMINUM SINGLE HUNG WINDOW
EXTERIOR VIEW
FLANGE A FINLESS INSTALLATION
SEECHART #f FOR SMALLER UNITS REOUIREDANCHORS
36" MAX
FRAME WIDTH
16"
2" MAX MAX 2" MAX
O.C.
2"�
T-
16"
MAX O O.C.
J_
84"
MAX
FRAME
HEIGHT
u"
185ALUMINUMSINGLEHUNG WINDOW
DESIGNER EXTERIOR VIEW
FLANGES FINLESS INSTALLA770M
SEE CHART #I FOR SMALLER UNITS REOUIREDANCHORS
DESIGNPRESSUREIIATING
IMPACTRATING
t55.0PSF
LARGE
MISSILE IMPACT
MISSILE LEVEL D, WINOZONE3
NOTES:
1. MAXIMUM SASH SIZE: 34 1/2" X 36".
2. MAXIMUM SASH D.L.O.: 31 1 /2" X 32 1 /2"
3. MAXIMUM FIXED D.L.O.: 33 1 /8" X 45"
K I(2) METAL SWEEP LOCK AT FROM EACH END INTERIOR MEETING RAIL I
RE115ION5
o6aaanon Hun:
REVISED ANCHOR SPACING $ CHARTS 07/11/16 R.L.
REVISED GLASS 10/02/17 R.L.
CHART#i FLANGE& FINLESS INSTALLATION
Number of anchor locations required
Frame
Height
pn)
i Frame
Widthfin)
18.00
241Go
au uu
36.00
Heed
Jamb
Head
Jamb
Head
Jamb
Keed
Jamb
2400
2
3
3
3
3
3
3
3
30.00
2_
3
3
3
3
3
3
3
36.00
2
3
3
3
3
3
3
3
4200
2
4
3
4
3
4
3
4
48.00
2
4
3
4
3
4
3
4
5�00
2
5
3
5
3
5
3
:5
60.00
2
5
3
5
3
5
3
5
66.00
- 2
5
3
1 5
3
3
7200
2
6
3
6
3
6
3
6
7800
2
6
3
6 1
3 1
6 1
3
8
84.00 1
2 1
8 1
3 1
6
3—F-61
3
8
SIGNED: 0212712020
MI WINDOWS AND DOORS, LLC
650 GRATZSPA 17030T MARKET50370
���uuugl
�\TREET
J!j RENOg'q���i
v, v�C S�. •d+
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI/`/`
` *4*
,aGs yr'
FLANGE AND FINLESS ELEVATIONS
'� �STAT��:
O ::+
//s/ONAI
7j1/1111;111)���
N.G.
owc Ro. 08-02545
R EV
B
SLUE NTS BATE 12/09/2014 -f 2 OF i t
L ROBERTO LOMASP.E
l,WWOODFORDRDLEIV/SVVANC27023
424.688-O 9 /aWaasC�ff&MtesA¢Wal
Luis R. Lomas P.E.
FL No.: 62514
36" MAX
FRAME WIDTH
10•'
2" MAX � MAX
O.C.
10" MAX O
O.C.
84"
MAX
FRAME
HEIGHT
2" MAX 2" MAX
2"
36" MAX _
FRAME WIDTH
10"
MAX
O.C.
L
10" MAX
O
O.C.
MAX
FRAME
HEIGHT
2" MAX
4
4
��
X-2-+JL:—i
165 ALUMINUM SINGLE HUNG WINDOW
185 ALUMINUM SINGLE HUNG WINDOW
EXTERIOR VIEW
DESIGNER EXTERIOR VIEW
FIN INSTALLATION
FIN INSTAUA71ON
SEE CHART I2FOR SMALLERVNlfSREOU/REDANCHORS
SEE CHART 82FORSMALLERUNITS' REQUIREDANCHORS
DESIGN PRESSURE RATING
IMPACTfwnNG
tff&OPSF
LARGE
MISSILE IMPACT
MISSILE LEVEL A WIND ZONE
INOTES:
1. MAXIMUM SASH SIZE: 34 1/2" X 36".
2. MAXIMUM SASH D.L.O.: 31 1/2" X 32 1/2"
3. MAXIMUM FIXED D.L.O.: 33 1/8" X 45"
Ilk 10 METAL SWEEP LOCK AT 8' FROM EACH END INTERIOR MEETING RAIL I
REN540N5
REV DMCR+RGN DATE ApPROVEo
A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
8 REVISED GLASS '�4/(12/17 R.L.
CHART O FIN INSTALLATION
Numb or of anchor locations required
Frame
Height
On)
Frema Width n
18.00
H d S
Jamb
1 24.00
H d S
Jamb
30.00
H& S
Jamb
36:00
H 3 S
Jamb
24.00
3
3
3
3
4
3
5
3
30.00
3
4
3
4
4
"4
5
4
3&00
3
5
3
5
4
5
5
5
4200
3
5
3
6
4
5
5
5
48.00
3
6
3
6
4
6
5
6
54.00
3
6
3
6
4
6
5
6
60.00
3
7
3
7
4
7
5
7
6E00
3
8
3
8
4
8
5
8
7200 1
3
8
3
8
4
8
5
B
78.00
3
9
3
9
4
9
5
9
BA00
3
9
3
9
4
9
5
9
SIGNED: 02/27/2020
MI WINDOWS AND DOOJREE
��►t►►IIL►////z
650 WEST MARKET ST�����5
GRATZ, PA 17030-0.,J
;t' LC,17��G
�CENS':�di��
SERIES 185 ALUMINUM SINGLE
X 84"—
FIN36"
NSFIN ELEVATIONSDRAWN:
DWG ND.'[OsrAtE
08—s0
DAE
NTS 12/09/2014
R. Lomos P.E.
No.: 62514
LROSERTOLOMISP.ELuis
I4WW000FORDRDLEWISVWAFL
42"W-OM l"=s@WbmWp
1/2" MIN
EDGE DISTANCE
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1 1/4" MIN.
j EMBEDMENT
-'--lr
BACKER ROD
& APPROVEDT51HIM
MAX.
SEALANTSPACE
#10 WOOD SCREW
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
SILL TO BE SET
IN A BED OF
APPROVED
STRUCTURAL
SEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1, INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEILANTBYOTHERS TO BE
DESIGNED INACCORDANCEWITHASTME2112
1 1/4" MIN.
EMBEDMENT
1
1/2'
MIN
EDGE
DISTANCE
#10 WOOD
SCREW
WOOD FRAMING
OR 2X BUCK
BY OTHERS
REwsoNs
DEScaPnON wle ." ::. nPPRavED
REVISED ANCHOR SPACING &CHARTS 07/11/10 R.L.
REVISED GLASS 10/02/17 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
71
BACKER ROD EXTERIOR r'
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCKINSTALLATION
SIGNED: OZ27/2021
MI WINDOWS AND DOORS, LLC
LLOIl���i
650 WEST MARKET STREET\\
GRATZ.
ft.
�S
PA 17030-0370
v EryS�90C
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
>Mr• p g26 W
36" X 84"- LMI
FLANGE INSTALLATION DETAILS
p STATE OF : ty
DMwN:
DWC NO,
REV
;cCQR1O?•
oe 45
a
�./1" R1 111 �\\\
�o
SCFLE NTS wtE 12/09/2014 4 OF it
L ROBER70 LOMAS RE
Ia2 WOODFORDADLEIWSVLM NG2702?
49458"M ,mmn,@NxnzWam
Luis R. Lomas P.E.
-FL No.: 62514
1/2" MIN
EDGE DISTANCE
METAL
STRUCTURE
BY OTHERS 1/4" MAX.
SHIM SPACE
APPROVED
SEALANT
REV6mdS
OESCMMON BATE APPROVED.
REVISED ANCHOR SPACING h CHARTS 07/11/16 R.L
REVISED GLASS 10/02,117 R.L.
1/4" MAX.
SHIM SPACE
II I11 #10 SMS OR
SELF DRILUNG #10 SMS OR
SCREW SELF DRILLING INTERIOR
INTERIOR SCREWS
t�
MIN.
EDGE
DISTANCE
VE:�— EXTERIOR
EXTERIOR METAL
STRUCTURE BACKER ROD
BY OTHERS & APPROVED
SEALANT
I I I JAMS INSTALLATION DETAIL
METAL STRUCTURE INVALLATION
SILL TO BE SET
IN ABED OF
APPROVED
S
STRUCTURAL
BACKER ROD SEALANT
& APPROVED
SEALANT""4
1/4" MAX.
Vl- SHIM SPACE
METAL
STRUCTURE
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FORCLARIT'Y
2 PERIMETER AND JOINT SEALANT SYOTHERS TO BE
DESIGNED INACCORDANCEWITHA97M E2112
SIGNED: 02/27/ ow
MI WINDOWS AND DOORS, LLC
��uu►Ilu/���
650 WEST MARKET STREET
GRATZ, PA 17030-0370
\���J�S 4t LO,���i��
= r" V-GEN�F'Fi1'�;
0 g2g 1t
SERIES 185 ALUMINUM SINGLE HUNG WINDOW*•
36" X 84"- LMI
— /
FLANGE INSTALLATION DETAILS
�� STATE OF
;
�'��p•'OLORtOP•���t
mum
OWONO,
REV
N.G.
OB-0255
�I ON i
scA, E NTS OAIE SX�T
12/ 09/ 2014 OF 11
Luis Ralomcs "P.E.
.':L
L ROBERTOLO.NASP.E
14W WOODFORD RD LEWISNUA NG2Z=
4SC68B-0609 rtiomu@IAomasp�mm
FL 6251#
2 1/2" MIN.
EDGE DISTANCE
RnuloNs
CONCRETE/MASONRY
-
REV DESpiIP110N
GATE APPROVED
BY OTHERS
•• a • • .
A REVISED ANCHOR SPACING &CHARTS
07/11/16 R.L.
d'
' e 1 1/4" MIN.
•e'
8 REVISED GLASS
..1L1/02/17 R.L
OPTIONAL 1 X BUCK ' '
.' � 4: EMBEDMENT
SEE NOTES 3 — 7
SHEET 1
T
I
EMBEDMENT SHIM„SPACE
1/4" MAX•
CONCRETE/MASONRY
BY
BACKER ROD
SHIM SPACE
OTHERS
& APPROVED
o'a
SEALANT
3/16" TAPCON
3/16" TAPCON ,
° INTERIOR
INTERIOR
2 1/2"
MIN.
EXTERIOR
EDGE °
DISTANCE
EXTERIOR
BACKER ROD
& APPROVED
OPTIONAL 1X BUCK SEALANT
SEE NOTES 3 — 7
SHEET 1 JAMB INSTALLATION DETAIL
BACKER ROD
CONCRETFJMASONRYINSTA[LA770N
& APPROVED
SILL TO BE SET
SEALANT
IN A BED OF
APPROVED
NOTES:
OPTIONAL IX BUCK
STRUCTURAL
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
SEE NOTE 3 — 7
SEALANT
NOTSHOWNFORCLIR►TY.2PERIMETERANDJO/NTSEALA/YrBYOTHERSTOBE
SHEET 1
1/4• MAX
`SHIM SPACE
DESIGNED INACCORDANCE WITHASTME2112
S/GNED:02/27/2020
CONCRETE/MASONRY
{
MI WINDOWS AND DOORS, LLC
BY OTHERS
650 WEST MARKET STREET
`\\`\51R-IL/od,,�i''
d
GRATZ. PA 17030-0370
• d
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
*•
•
3N X 84"— LMI
°
I
FLANGE INSTALLATION DETAILS
.. d
DRAWN: 71 DWG NO. REV
I�OR1OP• ���
��i�Ss'0NA
AL
CETFJMASONCROSS
SYIEALLAOON
8 B
scar: QA1E
-
11�\
CONCRI
ANST
NTS 12/09/2014 sREEr 65 OF 1 1
L ROBERTOLCA"SP.E
1
Luis R. Lomas P.E.
42"80 os�oy cm
FL No.: 62514
1/2" MIN
EDGE DISTANCE
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD 1/4" MAX. J
& APPROVED
SEALANT FIN SHIM SPACE
#10 WOOD SCREW
INTERIOR
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK,
BY OTHERS
iILL TO BE SET
V A BED OF
IPPROVED
TRUCTURAL
iEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCKINSTAUAT70N
NOTES.,
1. INIERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLIRIIY.
2. PERIMETER AND JOINT SEALANTBYOTHERS TO BE
DESIGNED INACOORDANCEWRHASTME2112
IJ
1 1/4" MIN.
EMBEDMENT
1
1/2"
MIN
EDGE
DISTANCE
#10 WOOD
SCREW
WOOD FRAMING
RENSIONS
DmmpnoN am
REVISED ANCHOR SPACING & CHARTS 07/11/16 ' R.L.
REVISED CLASS �, 10/02/17 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
OR 2X BUCK EXTERIOR
BY OTHERS BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
SIGNED: 02/27/2021
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
\��ttuR1lLuiir��
��� �5, .. 0�
v •��cEn1SF'?�;
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"- LMI
Z*-' 0 6
FINLESS INSTALLATION DETAILS
��WE OF fu
DRAWN:
OWC N0.
REV
�"cesi=L(ORtbQ: 6?
alE
B
SZO11In111�?\\``
NTS 12/09/2014875 OF 11
I-AMERTOLO&OSP.E
14XW00DFDRDRDL>w/SvntE`l�02=
44s-5>?9�ot�9 rtlmnattr�4lmuspomm
L Luls R. Lomas P.E.
: FL as
METAL
STRUCTURE
BY OTHERS
1/2" MIN
EDGE DISTANCE
1/4" MAX.
SHIM SPACE
APPROVED
SEALANT
f/10 SMS OR
SELF DRILLING
SCREW
INTERIOR
EXTERIOR
Neti+sTONs .
oFscLaPnon WTE AMWVM
REVISED ANCHOR SPACING B CHARTS o7/11/16 R.L
REVISED GLASS 10/02/17 R.L
1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING*RRODD
IOR
SCREWS
T-
1/2"
MIN.
EDGE
DISTANCE
ERIOR
METAL
STRUCTURE
& APPROVED
BY OTHERS
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
SILL TO BE SET
IN A BED OF
APPROVED
STRUCTURAL
BACKER RODAMP
S��M
& APPROVEDv
SEALANT
1 /4" MAX.
SHIM SPACE
METAL
SIGNED. 0212712020
STRUCTURE
BY
MI WINDOWS AND DOORS LLC
,
OTHERS
650 WEST MARKET STREET
`\���111111/////7
�\\\\g ;:'.:'D�fjr�ri�
GRATZ, PA 17030-0370
vJ.��GENs�'�,p�y
VERTICAL CROSS SECTION
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
1t
METAL STRUCTURE INSTALLATION
36" X 84"— LMI
`>ft �
FINLESS INSTALLATION DETAILS!
"o✓/�j
STATE' OF
1/NIERIORANDEXTERIORFINISHES,BYOTHER4
0R
DWG NO.
NOTSHOWNFORCLARRY.
08-02�545
B
s;�(pR�gP 6\��
IPERIMETERANDJO/NTSEALANTBYOTHERSTORE
scuE DATE
NTS 12/09/2014 8 OF 11
DESIGNED INACCORDANCEWRHASTME2112
LROBERMLOU4SP.r:
lag WOODFORD RD LEW/SVHIA NC27023
434-MB-OM XwmF&NamzmLwm
Luis R. Lomas P.E.
FL No.; 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK -
SEE NOTES 3 — 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EDGE DISTANCE
a. 1 1/4" MIN.
° EMBEDMENT
i
1 /4" MAX.
SHIM SPACE
3/16" TAPCON
INTERIOR
EXTERIOR
SILL TO BE SET
BACKER ROD
IN A BED OF
& APPROVED
APPROVED
SEALANT
STRUCTURAL
SEALANT
OPTIONAL 1X BUCK
1/4. MAX
SEE NOTE 3 — 7
F SHIM SPACE
SHEET 1
T
CONCRETE/MASONRY
BY OTHERS
'd a ,
a �
.°
VERTICAL CROSS SECTION
CONCREI EJMASONRY INSTALLATION
REMONS
REV DESCPoPNON I., DATE APPROVED
A REVISED ANCHOR SPACING do CHARTS 07/11/16 R.L.
B REVISED GLASS a'I
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY
BY OTHERS OPTIONAL 1X BUCK
• SEE NOTES 3 — 7
a SHEET 1
3/16" TAPCONF ° 1/4" MAX.
`...
SHIM SPACE
INTERIOR
2 1/2" ,
MIN. a
EDGE
DISTANCE
�_ •, . .. EXTERIOR
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATIONDE7"AIL
CONCRETEAMSONRYINSTALLA77011
NOTES.
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FOR CLARRY-
2 PERIMETERAND JOINT SEALANT BYOTHERSTO SE
DESIGNED INACCORDANCEWRHASTM 0112
SIGNED. 0212712020
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ,
`�.�JxS ;, LOTS//
PA 17030-0370
` r•.���EH,q•:9s�y
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
5 t><_
36" X 64"—
FINLESS INSTALLATION DETAILS
N
OF tv`
DRavN: Dwc ND, REv
�0�.�•• �OR►OQ;.
BSi�MAl1Ea��t�
s�uE NTS °ATE 12/09/20148 9fE9 OF 11
LROBERTOLOMA9P.E
14M WOODFORD RD LEWISVXM NO27D29
Luis R. Lomas P.E.
istsS"M +umRatowwwpec"
FL No.: 62514
q
APPROVED
SEALANT
BEHIND FIN
{
7/16' MIN pp
EDGE DISTANCE rl
1 1/4" MIN.
EMBEDMENT
WOOD
FRAMING
BY OTHERS
1/4" MAX,
—� SHIM SPACE
tEW
EXTERIOR
INTERIOR
WOOD FRAMING
BY OTHERS
1 1/4"
MIN.
EMBEDMENT
APPROVED
SEALANT
BEHIND FIN
RNSIONS .
DESODPIIDN DATE APPRGVED
REVISED ANCHOR SPACING & CHARTS 07/11/I6 R.L
REVISED GLASS 10/02/17 R.L
1/4" MAX
SHIM SPACE
I/,
—�8WOOD
SCREW
INTERIOR
7/16' MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK/NSTALLA710N
Lr—
NOTES:
1/4' MAX
1.INTERIORANDEXTERIORFINISHES, SYOTHERS,
`SHIM SPACE
NOTSHOWNFOR CLARITY.
2 PERIMETER AND JO/NTSE4LAM BYOTHERS TO BE
—1-
DESIGNED INACCORDANCEWRHAS7ME2112
7/16" MIN r
I
SIGNED' 02l2712020
EDGE DISTANCE,
MI WINDOWS AND DOORS, LLC
0%M111111jz
{J8 WOOD
w000
650 WEST MARKET STREET
zl�\\ 5 R' LQ
O\ • ���
• "E
SCREW
FRAMING
GRATZ, PA 17030-0370
;t •
` r,•4\C N
1 1/4" MIN.
APPROVED EMBEDMENT
BY OTHERS
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
_ *� .
0
SEALANT
36" X 84"— LMI
cet
BEHIND FIN VERTICAL CROSS SECTION
FIN INSTALLATION DETAILS
=�� ��
—� , TAT OF :�C
WOOD FRAMINGOR2XBUCKINSTALLATION
oRAWN: Oxc xa Riv
��`' • 'k
i�
08-02545 B
�c••;20R10
j00NAl1C�G\\`
scuE DATE / / sxtE110 OF t t
NTS 12 09 2014
LROSERTOLOMASP.E
14221=13FORD ROLEWMVIILF NO
us
LiR.P.E.
f2(4w-"m amms@kbmxpoxm
FIL NoLomas
-7 2 3/16"
13 116`
FLANGE FRAME HEAD
CM-18501
ALUMINUM 8063-T5.050' THICK
2 5/16"
1p3 3/8`
FLANGE FRAME SILL
CM-18502
ALUMINUM 6063-T5.055' THICK
1 5/8"
1 3
LOCKRAIL/STILE
CM-18565
ALUMINUM 6063-T5.062'THICK
GLAZING BEAD
CAI -law
RIGID PVC.050'THICK
1 7/8`
2 3I/16
J�
FLANGE FRAME JAMB
CM48503
ALUMINUM 6063-TS -050' THICK
2 5/16" �1
2 13I/1 `
.J�
FINLESS FRAMESILL
CM-18554
ALUMINUM 6063-T5.055'THICK
1 7/16`
2 5/16"
L
SASH BOTTOM RAIL
CM-18555
ALUMINUM 6O63-T5.0.S0' THICK
t —{7 3/8��
15/16" J
TSASH STILE
CM-18507
ALUMINUM 6063-T5.050 - THICK
I4j 2 3/16" 7
1 5/16"
1 FINLESS FRAME HEAD
CM-18553 —
ALUMINUM 6053-T5.050' THICK
1 3/8�-
2 L
LEq
FINLESS FRAME JAMB
CM-18513
ALUMINUM 6063-T5.050'THICK
2 5/16" -.i
F 1
2 3/I6" 1
3 3/4"
2 5/1�
FIN FRAME SILL FIN FRAME HEAD
CM•18509 CM-165D8
ALUMINUM 6063-T5.055'THICK ALUMINUM 6083-T5.050'THICK
T-f
2"
L
MEETING RAIL
CM-18504
ALUMINUM 6063-T5.055.714/CK
2
FIN FRAME JAMB
CM-18510
ALUMINUM 6063-T5.050'77ifCK
fmvistons
DESCRman
REVISED ANCHOR SPACING & CHART:
REVISED CLASS
ate AMOM
07/11/16 R.L.
t0/02/17 R.L.
5/8"
1/8" ANN.
3/32 ANN.
.090 PVB. BY KURARAY
3/32' ANN.
EXTERIOR METAL BUTYL REINFORCED
SPACER
114TERIOR
1/2" SITE SUICONE;
SEALANT "
SETTING BLOCK
GLAZING DETAIL
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"- LMI
COMPONENTS
I N.G. 108-02545 1 B '
I—L NTS I a'TE 12/09/2014 1 wEu I t OF 1 1 1
LROBEATOLOM SPZ
14"WOODFORORDLEHh4VRLF NO27M3
434,6eB• M d=mcqkbum
SIGNED. =127/2=
Luis R. Lomas P:E.
FL No.: 62514