Loading...
HomeMy WebLinkAbout5705 Seagrape Dr Permit Info SheetC�Lit J I f0, ST. LUCIE ti'`Aji I.ti ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET .APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Required Sections of the Permit Application Form Attachments Required See List Below 1A3,4,5,6,7 A, B, C Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5.6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5.B,7_ Metal Roofs A, B, D 1,P.3.4,5,6.7 Wood Shingles and Shakes A, B, D 1,2,4,5.6,7 Other sm, As ApµHta'ble 1,2,3,4,5,6,7 U ATTACHMEN-M REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4, Other Component of Product Approval 5, Municipal Permit Application ' 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No, Process No. Contractors Name: Collins Roofing Inc. License# CtCCC-058011 Job Address7� \ 11 �Y 1- P� �� 4 I r c-c—,� ROOF CATEGORY ❑ w Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles MAsphaitic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE.� '' ❑ New roof ❑ Repair ❑ Maintenance NReroofing ❑ Recovering yy ROOF SYSTEM INFORMATION 4 Low Slope Roof Area (SF) _ V Steep Sloped Roof Area (SF) Z " t I' CTotal (SF) zC1 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. r 111 I C)'- -1 c, -- ST. LUCIE WORKS Section ❑ (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: FL _ +� '110G�e Minimum Design Wind Pressures, if Applicable (From RA5 127 or Calculations): 81.7 4 Zone 1• I Zone 2e:-Zone 2n: I one 2r:'one 3e: Zone 3r: Deck Type: 518" Plywood Type Underlayment Self Adhesive Underlayment Roof Siope: Insulation NIA Fire Barrier: NIA Ridge Ventilation? �Fastener Type& Spacing: 6 Nails PerShingle - 1 114" Coil N Is rJ 0 Y1.2_ —:]. Adhesive Type: Bituman Tar Type Cap Sheet N/A Mean RooNeight: 15 ft Roof Covering: Dimensional Asphault Shingles) Type & Sim Drip 2"x2" Galv. Steel Edge;