Loading...
HomeMy WebLinkAboutBuilding PlansProduct Approval Affidavit PRODUCT MODEL # MANUFACTURERATTACHMENT METHOD FL# & tXP DATE' (6) 8d Ring shank nails ea, shingle as per mfg. specs. FL10124_R27 EXP 12/16/2022 Asphalt Roof Shingles Timberline GAF OPENING & MODEL# MAtJUFACTUREl2 GLASS ATTACHMENT METHOD FL# & EXP DATE PRODUCT DESIGN PRESSURE PRODUCT DESCRIPTION 7e�es "SH-5500 SERIES PGT' 7/8" NOM PER TABLE 3 SHEET OF THE NOA NOA# 20-0401.03 Single Hung SH-5500 TYPES EXP.July/20/2025 M.l: daw L SCOPE OF WORK - Wood framed addition and covered porch NOTE: ALL CONSTRUCTION MUST COMPLY WITH THE FBC, AND THE FBC RESIDENTIAL, 2020 PLUMBING CODE,1020 MECHANICAL CODE AND THE NEC (NFPA 70) 2017 EDITION. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE FBC FOR EXISTING BUILDINGS, THE FBC, AND THE FBC RESIDENTIAL THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC FOR EXISTING BUILDINGS CHAPTER 6 AND 7 NOTES: - THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. - STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. - ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE FBC / FBCR 2020. SECTION R806 ROOF VENTILATION R806.1Ventilation required. Encl osed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Ventilation openings shall have aieast dimension of 1/16 inch (1.6 mfi) minimum and 1/4 inch (6.4 mm) maximum. Ventilation openings having a least dimension larger than 1/4 inch (6.4 mm) shall be provided with corrosion -resistant wire cloth screening; hardware cloth or similar r"terial with openings having aieast dimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. Openings in roof framing members shall conform to the requirements of Section R802.7. Required V@ntilation openings shall opendirectly to the outside air. R806.20nimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. Exception: The minimum net free ventilation area shall be 11300 of the vented space provided one or more of the following conditions are met: 1.In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed on the warm -in -winter side of the ceiling. 2.Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of the space, measured vertically, with the balance of ire-d ventilation provided by eave or cornice vents. Where the location of wall or roof framing members conflicts with the installation of upper ventilators, installation more than 3 4 mm) below the ridge or highest point of the space shall be permitted. R806.3Vent and insulation clearance. Where save or cornice vents are installed, insulation shall not block the free flow of air. Not less than a 1-inch (25 mm) space shall be provided between the insulation and the rooisheathing and at the location of the vent.`.a R806.41nstallation and weather protection. Ventilators shall be installed in accordance with manufacturer's instructions. Installation of ventilators in roof systems shall be in accordance with the requirements of Section R903. Install' tion of ventilators in wall systems shall be in accordance with the requirements of Section R703.1. CONNECTOR SCHEDULE (Simpson Strong -Tie) ID 4TY CONNECTION POINT ALLOW UPLIFT FL# H10A Truss to Top Plate @ each Truss 1,040 Ibs FL10456-R4 Exp.12-31-2020' SPH6 Top & Bottom Plate to Wall Studs Q each stud 1,286lbs FL10456-R4 Exp.12-31-2020 HETA40 Wood -framed floor to top of concrete wall @ 48" O.C. Max 1,810 lbs FL11473-R4 Exp.12-31-2020 EXISTING STRUCTURE 540 Sunrise Dr Fort Pierce STRUCTURAL NOTES: 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-16. 2) SOIL BEARING CAPACITY: 2000 PSF (MIN.), 3) ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. 4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 %" SUSPENDED SLABS: 1%" 6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED,, 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 10)UNLESS OTHERWISE NOTED, ROOF SHEATHING TO BE NAILED WITH 8d RING -SHANK NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD. 11)UNLESS OTHERWISE NOTED FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 8" O.C. FIELD, OR SCREWED N011 DRYWALL SCREWS 1,5" LONG AND 0.131 DIA. 12)STUCCO SOFFIT NOTE: SOFFIT TO BE STUCCO OVER WIRELATH W/ 11GA, 2" NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" METAL RIB LATH @ 6" O.C. W/ (2 LAYERS) OF 15# FELT. *NOTE: PROVIDE TVVAK BUILDING WRAP BETWEEN PAPERBACKED LATH AND CDX PLYWOOD 13)EXTERIOR WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2- LONG NAILS WITH 3/8" O HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 15/32" CDX PLYWOOD WITH 10D NAILS TO STUDS @ 6" O.C. PERIMETER AND FIELD. 14)INTERIOR TO BE '/." DRYWALL FINISH. 15)WEEP SCREEDS. A MINIMUM 0.019-INCH (0,48 MM) (NO.26'GALVANIZED SHEET GAGE), CORROSION -RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF31/2 INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS INACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER -RESISTIVE BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. iNR807 kCCESS lttic access. Is with combustible ceiling or roof construction shall have an attic access opening to attic areas that h ive a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 lical height shall be measured from the top of the ceiling framing members to the underside of the r :o framing members. gh-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other readily accessible location. Where located in swell, the opening shall be than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) at some )ove the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics. REVIEWED FOR ' CODE COMPLIANCE ST. LUCIE COUNTY' BOCC FILEAffilk am AXIMUM HEADER SPAN 3'-0" 6'-0" UMBER OF FULL LENGTH KING STUDS EACH END OF HEADER 2 2 UMBER OF HEADERMACK STUDS SUPPORTING END OF HEADER 1 1 \n") SIC TY'01CAL HEADER DETAIL NO SCALE �uL FRAMING PLAN E: �/4a1` = 1'-0" A/R:N/A a,4M::, a Y xSuIis J}s,n M.99 r, x�my oxi Ityl'µl`', Mk k6W i'{ [j? G +4hRirI� rialyF r11RraIJa s& RRxyJl lalE ails r Ih ..+{ �alP l$Y R. a'`i� lu.^ a n la Rilai R11 r r h ,a« r 1P @I GY .aaraN' ry @�y� a •', F }la # �RF— ipW R!We tE Pi Q p i hpy i.; m ;k r r 'a a '9 h4r LI R�1- >ih• fi+tal II xY r �I '� o- � a q' zTa'r is ax k ul u + � M:; utl°4�a #kn k: u: "� �i:, a°; [f a gum 4� 3 { .s F'IfYrakisad'l111.11. G� �i k S Ruh'kry13Ii :V1 I`. II.. 0.1 kNio- iL hr. :u� tm.�": §�urcu , "i kk�k s� ,a..}740 6135� ROOF TRUSSES OR ROOF JOIST PER PLAN a L TA1 11J4 1 ' . 0 M XN 9251 795 —DOUBLE 2X6 TOP PLATE Elk —STRAP EACH STUD TO TOP PLATE WITH "SIMPSON" SPH-6 WITH (10)10d X 1 1/2" NAILS. �1F4 10. 10. 1 mwl� —STRAP EACH STUD TO TOP HEADER WITH "SIMPSON"11 d 2`LSTA-16 WITH (14) 10d NAILSX 12; ,:�c —FULL LENGTH 2X6 STUDS I T �' 18 1 14� 0,15 11/�'' —DOUBLE 2" X 12" WOOD BEAM WITH 1/2" PLYWOOD' 14 ()' C.14; 1f40 y'''(� SPACER GLUED AND NAILED WITH 10d NAILS AT S" O.C. STAGGERED TOP AND BOTTOM —HEADER STUDS 2X6 WOOD STUDS —STRAP EACH STUD TO BOTTOM PLATE WITH "SIMPSON" SPH-6 WITH (10) 10d NAILS HEADER STRIP —PT 2X6 WOOD BOTTOM PLATE SPF16 TOP & BOTTOM OF ALL EXTERIOR WALL STUDS 2X6 EXTERIOR WALL STUDS / @ 16" O.C. 2X6 BOTTOM WALL / PLATE SDWV13400 @6"O.C. I REVIEWED FOR CODE COMPLIANCE ST. LUCRE COUNTY BOCC 1y11aa�kWl RJI I�pyyj(� pq� 'nr'NGl raxpi k WrR laiy ku jH �'yI tl�{ly,SJ'@@ ai �!"�d al kk{rr:: �j .f7 J,yI ".:+ M1�I rPi z ly I{4� AnP,��l§ rtllx I�If3N�a' p�'4y �t PI 88R II {�lalal6 E�'�i uhl np sai€k nflil a ; lly�sI�ay �k,a iz9&u y�ISI I�w& w�R Ni15�;"'"3`tlS a4� Jkl4�'4c i�!,I«yi v%H(w�xk'€b ICI ffr r± '��i Till.001011010 ry o-i{ Wfr; !l II r ISINnI h � Nam a l i'A I: lay �3 s Il Ya ytl: ICIk*� ru ll kRo- Rogow a P, o- P Aa l r- 44 � a • a ° . �.: a � 1r r r't ^ 7� J�� .e �t� r**� �s�IA o.. r 4USP UILISP " 11FU7P as DFL]SP ; Sole Piate a Sole Plate Sole, Plate' S61e Plate., uwani ,rim 11; 35 x 4 SDWV13400 2x 1 75 220 1 175 165 160 185 165 185 1 176 2 FOUNDATION TO WALL STUD DETAIL.. A fA W U aw Ir rn Q CY 0 ' DATE 09-21-2020 SCALE DRAWN 09-21-2020 JOB 540SunriseDr SHEET 05 p yl--_ — - 3 INSULATION r FINISH COA1 I CEME ST NpL TWEEN PLYWOOD VERTICAL & kL JOINTS DS LAYERS OF WATER ESISTANT BARRIER, 0 LB. FELT, MIN. HEATHING: XTERIOR GYPSUM, LYWOOD, OR OSB ELF -FURRING LATH AILED @ 8" O.C. ERTICA LY & ORIZONTALLY I 02011 INTERNATIONAL MASONRY INSTITUTE R-30INSULATION _ i 4 3 f 1 F k Y py J TA 5NMI: Il ,II-M SCISSOR TRUSS FIBERGLASS SHINGLES TO MATCH E O e" CDX ROOF SHEETING 2X8 FACIA 12 VAULTED CEILING 2 F_ WALLS 2' GYP w g' GYP R-13 WALL w O INSULATION O w WIRE LATH & :D STUCCO VENEER \ U 00 ¢ WALL SHEATHING " U) CDX O R-19 Insulation in Floor Joists 2X10 FLOOR ? DECK t" CDX Tyvek Vapor barrier attached to JOISTS@ 16" ( the underside of 2x10 floor Joists. O.C. u5 u_ CONCRETE OR > CMU BOND _ r BEAM BUILDERS A OPTION '- r 2X4 OUTLOOKERS @24"O.C. i 12" TO 16" O.H. i i STUCCO oe i i PRE-ENG. TRUSSES 2X BLOCK @ 8' WIRE LA sTucc .S PER F.B.C.2514.3.5 ,QUIVALENT OF 6D GALVANIZED OR BLUE COMMON NAILS DRIVEN TO A - 'ENETRATION OF AT LEAST 3/4 INCH (19 MM) AND BENT OVER TO ENGAGE NOT ASS THAN THREE METAL AND WIRE LATH SHALL BE ATTACHED TO VERTICAL WOOD - SUPPORTS WITH THE OTHER HORIZONTAL WOOD SUPPORTS WITH THE EQUIVALENT _ )F NO. 11-GAUGE, BARBED, GALVANIZED OR BLUED NAILS 1-1/2 INCHES (38 MM) ONG HAVING A HEAD NOT LESS THAN 3/8 INCH (9.5 MM) IN DIAMETER. STRANDS )F LATH. METAL AND WIRE LATH SHALL BE ATTACHED TO CEILING JOISTS OR .30FFIT VENTS TO BE 6"X24" AT 8' O.C. MAX. EXTERIOR CEILING/SOFFIT DETAIL N.T.S. ' - ASTM 7.10.2.3: EXPANDED 3/8" 19.5 MM) RIB ' - LATH SHALL BE ATTACHED TO HORIZONTAL AND VERTICAL WOOD FRAME MEMBERS VATH - NAILS OR STAPLES TO PROVIDE NOT LESS - THAN 1-3/4" (44.5) MM PENETRATION INTO 2X6 WALL STUD @ HORIZONTAL WOOD FRAMING MEMBERS AND (19.1 MM) PENETRATION INTO VERTICAL O.C.3/4" 16" V WOOD FRAMING MEMBERS. II ' II 2- BALLOON FRAMING ELEVATION 05.1 SCALE: 1/2" _ 1'-Ut A/R:N/A REVIEWED FOR CODE COMPLIANCE E COUNTY J ST. LOCI R CC I - - - - - --:-__ ------ --- LAV#1 PROPOSED PLUMBING PLAN SCALE: 1/2" = 1'-0" A/R:N/A 2"VIR v 4"HOT WATER u Lo Q (� co .a C] LL w 6 L p_ m W .^- C7 a" g LL ` -1/2" LAV #1 f-- CD Q � ;E o L. ul a z w y Y '- in ur9 z z Qt 3" WC 3" CO Nj U F la! UI w Gl [] Ul 0 o N z z a v 0 U U ri a a a' 44 w wa @) z ° p rx 33 �r �r 3 a LL "c L% a x� w p u , .w 3" SHOWER I Q x. 4 DATE 09-21-2020 3" P-TRAP TCSEPTIC SCALE 2 PLUMBING RISER DIAGRAM DRAWN 09-21-2020 „ P1 SCALE: 1 = 1 —0 A/R:N/A REVIEWED FOR JOB 540Sunrisel)r CODE COMPLIANCE SHEET ST. LUCIE COUNTY I BOCC VP E WH � n HH Lll J CL I i E > 220 ,.. .6110 'loo III I U- ' r w �A- a VP HH / /Lp 22 0 REF ® ® \ AlF HANDLER . Op \\\//3' BY RETURN ZL1 u• �N \ / Zur U SCALE EXISTING FRONT PORCH �.}} DRAWN 09-21-2020 VP7777/27/7/� JOB 5405unriseRr REVIEWED FOR PROPOSED ELECTRICAL PLAN coDEco COMPLIANCE SHEET ST. LUCIE COUNTY BOCC -F E1 SCALE: 1/2" = 1,_0„ A/R:N/A ' �.. . E,...., 1' I k 2'X2' ABC IMPACT AIR HANDLER RATED WINDOW 09-21-2020 540SunriseDr I