Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance MethV.`> T n�� ProjectName: DEE & ANTHONY BROWN BuilderName: � Q� Street: 540 SUNRISE DR. Permit Office: ST. LUCIE COUNTY ,.��p ip 4Z u� City, State, Zip: FT. PIERCE , FL, PermitNumber: Owner: DEE & ANTHONY BROWN Jurisdiction: 6611000 DesignLocation: FL, Fort Pierce County, St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (456.0 sqft.) Insulation Area 2. Single family ormultiple family Single-family a. Frame -Wood, Exterior R=11.0 456.00ftz b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms (Bedrms In Addition) 1(1) d• N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (330.0 sqft.) Insulation Area a. UnderAttic (Vented) R=30.0 330.00 ftz 6. Conditioned floor area above grade(ftz) 330 b. N/A R= ftz Conditioned floor area belowgrade(ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(26.0 sqft.) Description Area a. U-Factor: Sgl, U=1.05 26.00 ftz SHGC: SHGC=0.30 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 9.0 SEER:18.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficlency d. U-Factor: N/A� ftz a. Electric Heat Pump 9.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems -Nonerequired 8. Floor Types (330.0 sqft.) Insulation Area a. Cap: N/A EF:2.24377E027 a. Raised Floor R=19.0 330.00 ftz b. Conservation features b. N/A R= ftz c. N/A R= f ftz 15. Credits Pstat Total Proposed Modified Loads: 10.79 Glass/Floor Area: 0.079 PASS Total Baseline Loads: 14.87 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are In compliance with the Florida Energy specifications covered by this DZ1i:ST.q?A Code. calculation indicates compliance with the Florida Energy Code. N rmr ''r•, .;; ° All PREPARED BY: Before construction is completed DATE: 11-19^20 0 this building will be inspected, for. compliance with Section 553.908 _ a I herebycertify that this bu' i , as si compliance fY P Florida Statutes. � S �, With the Florida Energ OWNER/AG T BUILDING OFFICIAL: DATE: DATE: r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). F N= ,=, &VIM u0py 11/19/2020 10:06 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software m Page 1 of 4 r/'11OAA OAnG nnd7 IIUDI IT CI IMMARV r_I4Fr_10 1ST RFPART PROJECT Title: DEE & ANTHONY BROWN Bedrooms: 1 Address Type: StreetAddress Building Type: User ConditionedArea: 330 Lot# OwnerName: DEE & ANTHONY BROWN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 540 SUNRISE DR. Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: 6611000 Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Winter Temp Heating Design Summer Degree Days Moisture DailyTemp Range DesignLocation TMY Site 97.5% 2.5% FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 330 2640 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 NEW WIC 53 424 No 0 1 Yes Yes Yes 2 NEW M BATH 67 536 No 0 1 Yes Yes Yes 3 NEW M BEDROOM 210 1680 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Raised Floor NEW WIC ---- ---- 53 ft2 19 1 0 • 0 2 Raised Floor NEW M BATH ---- ---- 67 ft2 19 1 0 0 3 RaisedFloor NEW M BEDROO ---- ---- 210 ft2 19 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area. Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Compositionshingles 357ft2 0ft2 Medium N 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 330 ft2 N N 11/19/2020 10:06 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 _..4� FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan �j Feb Mar Mar Apr E Apr f Ma May [X] Jun [ r Jun Jul 4 Jul Au 4 AuSep Se Oct NNov Oct Nov Dec Dec Venting Jan [[ ]] Feb Mar [xl Apr [ may [[[ ]Jun [ Jul [ Aug Se Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (W EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft2 Oft 0.3 NEW WIC Default(8lbs/sq.ft. ft2 ft 0.3 NEW M BATH Default 8lbs/s .ft. ft2 ft 0.3 NEW M BEDROOM 11/191202010:06 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4