Loading...
HomeMy WebLinkAboutPerformance Certification; Impact FixedImpact Performance Certification Authorization Report uoc No: FRAA B7 -43 Rev No: 4 1 Psm: 1 1 CAR & Product ID Number. 464 - 251 Issue Date: 6/15/2018 Revision Date: 7/6/2018 Expiration Date: 6/15/2022 Company Code: 464 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and Is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, Including installation, condition of the wall/roof substrate and the age of he product and installation components. This report indicates the product Is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keyslonecerts.com. I Licensee Information: I Product Information: I Viwinco, Inc. I Model: Signature/Viwinco Impact Fixed 851 Hemlock Rd Morgantown B Operator Type: FW Morgantown PA 19543-0499 1 Config: No, GS-7/32" Ann Lami IG Max Width: 72 Max Height: 72 Corresponding Structural CARS: 464-497 Referenced Standard: Product Rating: ASTM E1886-13a, ASTM E1996-14a Missile Level D,Wind Zone 3 DP+-60, 72x72 Qualifying Test Information: Test Report No: ATI-12478.01-109-47/ATI-78079.03-109-47 Test Report Expiration: 6/15/2022 Authorized Signature: Keystone Certifications, Inc. Digitally signed by Jon Hill 145 Limekiln Rd., Suite 100B Date: 2018.07.0610:1059 New Cumberland, Pennsylvania 17070 '-- --- 04'00' one: 717-932-8500 MOO 49GIRx: 717-932-8501 W W W. KEYSTONECERTS.COM 6" MAX. 72" MAX. FRAME HEIGHT SIGNA TUR1E/VIWINCO IMPACT FIXED EXTERIOR VIEW FRAME FLUSH INSTALLA77 NV DESIGN PRESSURE RATING IMPACT RATING ±50PSF LARGEAIVDSMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE3 REVISIONS REY DESCRIPTION DATE APPROVED A REVISED PER NEW CODE 12/04/14 R.L. MAX, NOTES: 4AX. 1, THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER .ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. AX 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1Y BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. FRAME MATERIAL: EXTRUDED RIGID PVC, 5. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 3 FOR GLASS DETAILS. 6. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 7. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM -ALLOWABLE SHIM STACK TO BE 1/4", 8. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1 /4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 9. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, 10, FOR ANCHORING INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 11. ALL FASTENERS TO BE CORROSION RESISTANT, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF 0=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3.192 PSI, C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90. GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 180A, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM TABLE OF CONTENTS SHEET NO. DESCRIPTION 7 - 2 ELEVATION, ANCHORING AND NOTES 3 CROSS SECTIONS AND B.D.M. 4 6 INSTALLATION DETAILS SIGNED: 1210512014 VIWINCO INC. N,� J`lllil/lt/, P.O. BOX 499 MORGANTOWN, PA 19543 `�,��5 ` LQ�L1 v 9Ji� •��GENSF ~* 51 ,yr= SIGNATURE/VIWINCO IMPACT FIXED 72 X 72F�y, 1" FRAME ELEVATION AND NOTES DATE OF ���F � j°C p lro"e- � . . s'-...• DRAWN: DVlC N0. REV A.S. S—E os-01 472 A ��iJ7s�QNAL`E \I` NTS °ATE 03/05/12 1 OF 6 A FF HE /Y MAX hKAML WIDTH 6" �r MAX O.C. T 1 ' MAX J 6" f MAX O.C. 2.. AY AME GHT SIGNATURE/VIWINCO IMPACT FIXED EXTERIOR VIEW FIN INSTALLA T70N DESIGN PRESSURER:4TING IMP.ACTR4TNVG tSQPSF LARG'EANDSMALL MISSILE IMPA CT MISSILE LEVEL P. WIND ZONE 3 1" MAX REVISIONS DESCRIPTION DATE APPROYED REVISED PER NEW CODE 1 12/04/14 JR.L. SIGNED: 12/05/2014 VIWI NCO INC. P.O. BOX 499 MORGANTOWN, PA 1954.3 EN *• 0 51 . SIGNATURE/VIWINCO IMPACT FIXED 72X72 NAIL FIN ELEVATIONQF�- wZZ ZZ p'"••'cLORtOP•'��'� • DRAWN: -0 NO. REV A.S. 08-01472 A/S;1• ... `yCGl �1�,� SCALE DATE 6"'` NTS 03/05/12 2 OF 6 PARTS LIST PART NUMBER DESCRIPTION MANUFACTURER MATERIAL 8915 FRAME Deceuninck PVC 5846 GLAZING BEAD Deceuninck PVC 7940 WEEP HOLE COVER Ashland PVC 7240T SEITING BLOCKS TB Philly VINYL 3462 SIUCONE DOW (TB PHILLY) SILICONE I a 2 13/16" 2 L_ o ° 1 I--- 3 1/4- Frame Sill VITVYL FVC.076 THICK Frarrre Sill (Nailing Fin) VINYL PVC.076 THICK 7/8- Glazing Bead VINYL PVC.061 THICK EXTERIOR INTERIOR VERTICAL SECTION OPTIONAL FIN FRAME RC RSIONS REV I DESCRIPTION DATE I APPROVED A I REVISED PER NEW CODE 12/04/14 1 R.L, INTERIOR EXTERIOR HORIZONTAL SECTION 15/16" 1/8" ANN. .100" SCP BY DUPONT 1/8" ANN, 1/8" TEMP. REINFORCED BUTYL SPACER SYSTEM EXTERIOR INTERIOR 1/2" BITE STRUCTURAL SEALANT SETTING BLOCK DOW INSTACLAZE GLAZING DETAIL VIWINCO INC. P.O. BOX 499 MORGANTOWN, PA 19543 SIGNATURE/VIWINCO IMPACT FIXED 72 X 72 CROSS SECTIONS AND COMPONENTS DRAWN: -0 N0. REV A.S. 08-01472 A SCALE 14TS IDATE 03/05/12 S-3 OF 6 SIGNED: 12/05'2014 `R `T LI02���r: TATE OFry_ %�7ss oNA l'����,. WOOD FRAMING OR 2X BUCK BY OTHERS APPROVED SEALANT #8 WOOD SCREW EXTERIOR #8 WOOD SCREW APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN, EDGE DISTANCE 1 1/4" MIN. EMBEDMENT 1 /4" MAX, SHIM SPACE METAL STRUCTURE BY OTHERS APPROVED SEALANT INTERIOR EXTERIOR VERTICAL CROSS SECTION WOOD FRAMING OR2X BUCK INSTALiA TION NOTE. INTERIORAND EXTERIOR FINISHES. BY OTHERS. NOT SHOWN FOR CLARITY. APPRO C SEAL �E MIN. GENT STRU BY 0' �REVISIONS - EDGE DISTANCE 3MIN. REV DESCRIPTION DATE APPROVED D VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION A I REVISED PER NEW CODE t2/Oa/ta R.L. 1/4.. MAX. SHIM SPACE � INTERIOR 3/4" MIN, EDGE DISTANCE #S SMS OR � Q SELF DRILLING SCREWS i OR METAL RILLING STRUCTURE BY OTHERS INTERIOR 1 1/4" MIN, EMBEDMENT 1/2„ 1 MIN EDGE pISTANCE #8 SMS OR #8 WOOD SELF DRILLING SCREW SCREW WOOD FRAMING OR 2X BUCK 1/4" MAX, BY OTHERS SHIM SPACE APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALLATION 1/4" MAX. r SHIM SPACE lNTER1C - V \U/ APPROVED SEALANT EXTERIOR( JAMB INSTALLATION DETAIL WOOD FRAMING OFT 2X BUCK INSTAU -A TION SIGNED: 12/0512014 NOX R l 1LI6 PI OBOX 499 `�����51 MORGANTOWN, PA 19543 SIGNATURE/VIWINCO IMPACT FIXED =*� 0 51 *: FRAME INSTALLATION DETAILS TAT DR DWD NO. REV %O�n�j°L0 k0l A.S. SCALE 08-01472 A/`�',$` 11/01111A1i1a\\` NTS DATE 03/05/12T4 OF 6 2 1 /2- MIN. EDGE DISTANCE CONCRETE/MASONRY ° BY OTHERS ° 4 1 1/4" MIN. OPTIONAL BUCK ° _ EMBEDMENT TO BE PROPERLY - SECURED f SEE NOTE 3 SHEET 1 } APPROVED ❑ SEALANT 1/4" MAX. SHIM SPACE 3/15­ TAPCON EXTERIOR I I I I INTERIOR 3/16" TlklN. APPROVED SEALANT OPTIONAL 1X BUCK1/4 MAX. TO BE PROPERLYSHIM SPACE SECURED SEE NOTE 3 SHEET 1 CONCRETE/MASONRY 1 BY OTHERS41 1 1/4" MIN. EMBEDMENT EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEMASONRY INSTALLATION 1 1/4" MIN, EMBEDMENT CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 3/16" TAPCON 2 1/2" MIN, EDGE DISTANCE REVISIONS REV DESCRIPnON DATE APPROVED A I REVISED PER NEW CODE 12/04/14 1 R.L. a 1 /4" MAX. SHIM SPACE 0 09 INTERIOR APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL CONCRRETE-'A4A,57ONRY INSTALLATION NOTE: INTERIORAND EXTERIOR FINISHES. BY OTHERS. NOT SHOWN FOR CLARITY. VIWINCO INC. P.O. BOX 499 MORGANTOWN, PA 19543 SIGNATURE/VIWINCO IMPACT FIXED 72 X 72 FRAME INSTALLATION DETAILS DRAWN: DVID NO. A.S. 08--01472 SCALE NTS I D— 03/05/12 1-5 OF 6 SIGNED: 1210512014 -A TAT OF A ��'/ss�01YAL1E�G�l� #8 WOOD SCREW 7/16" MIN EDGE DISTAN EXTE 7/16" MIN EDGE DISTANCE #8 WOOD SCREW tMtSEUMEN I VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD =RAMING 3Y OTHERS 1 /4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS REVISIONS DESCRIPTION DATE I AP- -REVISED PER NEW CODE 12/O4/14 1 R.L. WOOD FRAMING �{ 1/4_ MAX BY OTHERS I SHIM SPACE #8 WOOD SCREW INTERIOR I 1 1/4" MIN. EMBEDMENT 7/16"MIN EDGE DISTANCE EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X SUCK INSTA LLA TION NOTE: INTERIOR AND EXTERIOR FINISHES. SY OTHERS. NOT SHOWN FOR CLARITY. SIGNED: 1210512014 VIWINCO INC. P.O. BOX 499 MORGANTOWN, PA 19543GEM R"..L 0 �11/� p51 *- SIGNATURE/VIWINCO IMPACT FIXED*•' 72 X 72 NAIL FIN INSTALLATION DETAILS D•� TATE OFt� I` �1• EpRtO�' \��� DRAVlN: A.S. DWG NO. REV 08-01472 q SCALE NTS DATE 03/05/12 6 OF 6 R. 7 ' Document T81e: Structural Performance a Doc No: FRM B7-02 Rev No. 7 Page: � oe 1 Certification "He Authorization Report Required BY: PRO B1-03 CAR & Product ID Number: 464 - 497.0 Issue Date: 6/25/2014 Revision Date: 7/6/2018 Expiration Date: 5/12/2021 Company Code: 464 This Certification Authorization Report (CAR) is issued by Keystone C811cstlons, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wallfroof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keysbnecerts.com. Licensee Information: I Product Information: V!wlnco, Inc. 861 Hemlock Rd Morgantown Morgantown B PA 19543-0499 Model: Signature/Viwinco Impact Fixed Operator Type: FW Config: No, GS-5/16" Ann Lam! IG Max Width: 72 Max Height: 72 Referenced Standard: Product Rating: AAMAIWDMA/CSA 101/IS2/A440-05 FW-R55 1829xl829 (72x72) Qualifying Test Information: Test Report No: ATI-78079.03-109-47 Test Report Expiration: 5/12/2021 Authorized Signature: Keystone Certifications, Inc. Digitally signed by Jon Hill 145 Limekiln Rd. Suite 100B Date: 2018.07.06 09:44:55 New Cumberland, Pennsylvania 17070 ' L----04'00' Phone: 717-932-8500 Fax: 717-932-8501 W W W.KEYSi'ONECERTS.COM L. Roberta Lomas P.E. 233 W; Nlain Si Danville, VA 24541 434-6,99-0609 rll�masfi+;.lrl�maspc .couz lantdacturer: Viwinco, Inc. Morgantown .Busipess Park P.Q. Boy; 499 Morgantown, [)A 1954 Product Line: Signature/Viwinco impact Fixed Engineering Evaluation Report.' Report No. 512096A Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3:005 method 1(a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-01472 Revision A, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: ATI-76362.01-109-47 signed by Michael D. Stremmel, P.E. 3. Architectural Testing Inc., York, PA.: AAMA/WDMA/CSA 101/I.&2/A440-05 Design pressure: ±50.0psf Water penetration resistance 9.2psf 4. Report No.: AT1-75251,01-109-47 signed by Michael D. Stremmel; P.E. Arr.Nipe..tbral Testing Inc., York, PA ASTI'A El 886-02 and ASTM E 1996-02 ASTM El886/ El996 Large. Missile Impact, Level. D, Wind Zone 3. ASTM E1.886/ E1996 Cyclic Load Test, ±50.0psf design pressure 5. Anchor calculations, report number 512096-1, prepared; signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use:. • Maximum design. pressure: L50.0psf Maximum unit. size: 72'` x 72" • . Units must be glazed per ASTM El300-04, see installation instructions for glass details. • This. product is not rated to be used in. the HVHZ. • This product is impart resistant and does not require impact protection in wind borne debris regions, up to wind. zone':3. • Frame material to be rigid PVC. Installation: Units must be installed in accordance with approval, document 08-01472 Revision A. Certification of Independence: Please note. that I don't have nor will acquire'a financial interest n any company manufracturing or distributing the product(s) for which this report is being issued. Also, I don't have, nor will acquire ra financial interest in any other -entity involved in the approval process of the listed product(s):' .,�4a.'` -.TA T OF 0.PRIA NAL 1 of 1 Luis R. Lomas, P.E. FL No:::62514 12/09/2014