HomeMy WebLinkAboutAPPROVED DS8877588775 | 44316-3701851852 | Page 1/2 Date: April 30th, 2021 ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: 7816 S DIXIE HWY WEST PALM BEACH FL Project: ELMES RESIDENCE Project Address: 9400 S OCEAN DRIVE, 806 Jensen Beach Florida Box for Engineer Seal Only-Original Rqd for Permit & Use Frank Bennardo, PE FL46549 or Richard Neet, PE FL86488 The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above- referenced location. ASCE: ASCE 7-16 (7TH EDN FLORIDA BUILDING CODE, 2020 FBC, 2018 IBC) Wind Velocity: 170 MPH Exposure Category: D Kd: 0.85 Kzt: 1 Minimum Building Dimension: 170FT Mean Roof Height: 120FT Unit Elevation: 80FT ROOF SLOPE: SLOPED (>=10°) Number Of Openings: 4 Shutter: NO Mark: 1 Height Of Opening: 38 IN Width Of Opening: 36 IN Zone: 4 Mark: 2 Height Of Opening: 79 IN Width Of Opening: 106 IN Zone: 4 Mark: 3 Height Of Opening: 50 IN Width Of Opening: 110 IN Zone: 4 Mark: 4 Height Of Opening: 38 IN Width Of Opening: 73 IN Zone: 4 Based on the above, the following ASD design pressures apply for the opening marks which shall correspond with contractor-supplied building layout: a: 17 FT Mark: 1 Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com 88775 | 44316-3701851852 | Page 2/2 Wall Positve Pressure: 56.9PSF Wall Negative Pressure: -60.3PSF Mark: 2 Wall Positve Pressure: 51.7PSF Wall Negative Pressure: -56.8PSF Mark: 3 Wall Positve Pressure: 53.8PSF Wall Negative Pressure: -58.2PSF Mark: 4 Wall Positve Pressure: 56.9PSF Wall Negative Pressure: -60.3PSF Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings, visit EngineeringExpress.com/Wind. Powered by TCPDF (www.tcpdf.org) Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com