Loading...
HomeMy WebLinkAboutAPPROVED HR- 200 FL21557.1 9360 Sunset Drive Ste 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com PRODUCT APPROVAL EVALUATION RULE CHAPTER #61G20-3 • METHOD 1 OPTION D FL 21557 Date: 8/7/2020 Detailed Product Description: Manufacturer: E.S. WINDOWS, LLC. Manufacturer Address: 3550 N.W. 49 STREET – MIAMI, FL. 33142 Model Name: SERIES ES-EL200 ALUMINUM HORIZONTAL ROLLING WINDOW Maximum Load: +80 PSF, -90 PSF (Large Missile Impact) Installation Drawings # W16-69 This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements. For maximum sizes, combination of span vs loads and anchor type refer to installation drawings. Comparative analysis used Yes X No Mandatory Tests (Tested in accordance with AAMA 101/I.S.2/NAFS/TAS-202) TEST DESCRIPTION TEST LOCATION TEST REPORT DATE TEST REPORT # TEST SEALED BY ASTM E283 Air Infiltration Leakage Blackwater Testing Inc. Fenestration Testing Lab. 12/08/2016 04/23/2020 BT-ESW-16-007 FTL-11027 Constantin Bortes, P.E. Idalmis Ortega, PE ASTM E331 OR ASTM 547 & TAS 202 Water Penetration Blackwater Testing Inc. Fenestration Testing Lab. 12/08/2016 04/23/2020 BT-ESW-16-007 FTL-11027 Constantin Bortes, P.E. Idalmis Ortega, PE ASTM E330 & TAS 202 Uniform Static Air Press. Blackwater Testing Inc. Fenestration Testing Lab. 12/08/2016 04/23/2020 BT-ESW-16-007 FTL-11027 Constantin Bortes, P.E. Idalmis Ortega, PE ASTM F588 Forced Entry Blackwater Testing Inc. 12/08/2016 BT-ESW-16-007 Constantin Bortes, P.E. Model Name: SERIES ES-EL200 ALUMINUM HORIZONTAL ROLLING WINDOW Maximum Load: +80 PSF, -90 PSF (Large Missile Impact) 1235 SW 87th Avenue | Miami, FL 33174 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com Supplemental Tests (Tested in accordance with TAS-201 and TAS-203) TEST DESCRIPTION TEST LOCATION TEST REPORT DATE TEST REPORT # TEST SEALED BY FBC 1626.2 (TAS 201 & 203) ASTM E1886/1996 Large Missile Impact & Cyclic Blackwater Testing Inc. Fenestration Testing Lab. 12/08/2016 10/24/2017 04/23/2020 BT-ESW-16-007 BT-ESW-17-007 FTL-11027 Constantin Bortes, P.E. Idalmis Ortega, PE Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the above product conforms to the requirements of the 2020 Florida Building Code. Evaluation Report Engineer: Jalal Farooq PE # 81223 Al-Farooq Corporation EB # 3538 Sealed: 9/23/20 Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the above product conforms to the requirements of the 2020 Florida Building Code. Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20 Sealed: 9/23/20