Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
linda pyatt specs
January 2017 22-1904-1H-EN Split System Cooling 4TTR4018L1000A 4TTR4024L10 00B 4TTR4025L10 00B 4TTR4030L10 00A 4TTR4031L10 00A 4TTR4036L10 00A 4TTR4037L10 00A 4TTR4042L10 00A 4TTR4043L10 00A 4TTR4048L10 00A 4TTR4060L10 00A NNoottee::“Graphics in this document are for representation only.Actual model may differ in appearance.” Product Data 2 22-1904-1H-EN Product Specifications Model No.(a)4TTR4018L1000A 4TTR4024L1000B/ 4TTR4025L1000B 4TTR4030L1000A/ 4TTR4031L1000A 4TTR4036L1000A/ 4TTR4037L1000A POWER CONNS.—V/PH/HZ (b)208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 14 17 18 BR.CIR.PROT.RTG.—MAX. (AMPS)20 20 25 30 COMPRESSOR CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATAUFF®- SCROLL RL AMPS —LR AMPS 9 —63 10.1 —52 12.8—68 14.1—72 Outdoor Fan FL AMPS 0.60 0.90 0.77/.64 0.77/.64 Fan HP 1/15 1/8 1/8 1/8 Fan Dia (inches)18.2 18.2 23.0 23.0 Coil SPINE FIN™SPINE FIN™SPINE FIN™SPINE FIN™ Refrigerant R-410A 4 LBS.,8 OZ 4 LBS.,11 OZ 5 LBS.,4 OZ 6 LBS.,1 OZ LINE SIZE —IN.O.D.GAS (c)3/4 3/4 3/4 3/4 LINE SIZE —IN.O.D.LIQ.(c)3/8 3/8 3/8 3/8 Charge Spec.Subcooling 10°F 10°F 10°F 10°F /(8°F on 037) Dimensions H x W X D Crated (IN.)30.1 x 26.7 x 30 30.1 x 26.7 x 30 34 x 30.1 x 33 38 x 30.1 x 33 Weight —Shipping (lbs.)153 153 183 183 Weight —Net (lbs.)133 133 156 156 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 —BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset (d)TAYREFLN950 TAYREFLN950 TAYREFLN7*TAYREFLN7* Service Valve Panel Cover AAYSVPANL0022AA AAYSVPANL0022AA AAYSVPANL0032AA AAYSVPANL3343AA (a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b)Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (c)Standard line lengths —60’,Standard lift —60’Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0*(*denotes latest revision).. (d)*=15,20,25,30,40 and 50 foot lineset available. 22-1904-1H-EN 3 Model No.(a)4TTR4042L1000A/ 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A POWER CONNS.—V/PH/HZ (b)280/230/1/60 280/230/1/60 280/230/1/60 MIN.BRCH.CIR.AMPACITY 22 24 31 BR.CIR.PROT.RTG.—MAX.(AMPS)35 40 50 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS —LR AMPS 16.7 —109 18.5 —124 23.7 —152.5 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches)27.5 27.5 27.5 Coil SPINE FIN™SPINE FIN™SPINE FIN™ Refrigerant R-410A 6 LBS.,7 OZ 6 LBS.,9 OZ 7 LBS.,10 OZ LINE SIZE —IN.O.D.GAS (c)7/8 7/8 7/8 LINE SIZE —IN.O.D.LIQ.(c)3/8 3/8 3/8 Charge Spec.Subcooling 12°F 10°F 10°F Dimensions H x W X D Crated (IN.)34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight —Shipping (lbs.)216 212 246 Weight —Net (lbs.)184 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset (d)TAYREFLN7*TAYREFLN3*TAYREFLN3* Service Valve Panel Cover AAYSVPANL0044AA (a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b)Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (c)Standard line lengths —60’,Standard lift —60’Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0*(*denotes latest revision).. (d)*=15,20,25,30,40 and 50 foot lineset available. PPrroodduucctt SSppeecciiffiiccaattiioonnss 4 22-1904-1H-EN MODEL A-Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR4018L1 71 74 71 65 68 67 63 56 50 4TTR4024L1 4TTR4025L1 71 74 71 65 68 67 63 56 50 4TTR4030L1 4TTR4031L1 71 73 73 72 69 68 60 52 45 4TTR4036L1 4TTR4037L1 71 73 73 72 69 68 60 52 45 4TTR4042L1 4TTR4043L1 71 81 72 69 69 66 60 57 54 4TTR4048L1 71 81 72 69 69 66 60 57 54 4TTR4060L1 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270–2008 *For Reference Only PPrroodduucctt SSppeecciiffiiccaattiioonnss 22-1904-1H-EN 5 Accessory Description and Usage AAnnttii--SShhoorrtt CCyyccllee TTiimmeerr —Solid state timing device that prevents compressor recycling until five (5)minutes have elapsed after satisfying call or power interruptions.Use in area with questionable power delivery,commercial applications,long lineset,etc. EEvvaappoorraattiioonn DDeeffrroosstt CCoonnttrrooll —SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions.Used for low ambient cooling to 30°F with TXV. RRuubbbbeerr IIssoollaattoorrss —Five (5)large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad.Use on any application where sound transmission needs to be minimized. HHaarrdd SSttaarrtt KKiitt —Start capacitor and relay to assist compressor motor startup.Use in areas with marginal power supply,on long linesets,low ambient conditions,etc. EExxttrreemmee CCoonnddiittiioonn MMoouunntt KKiitt —Bracket kits to securely mount condensing unit to a frame or pad without removing any panels.Use in areas with high winds,or on commercial roof tops,etc. AAHHRRII SSttaannddaarrdd CCaappaacciittyy RRaattiinngg CCoonnddiittiioonnss AHRI Standard 210/240 Rating Conditions 1.Cooling 80°F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil. 2.High Temperature Heating 47°F DB,43°F WB air entering outdoor coil,70°F DB air entering indoor coil. 3.Low Temperature Heating 17°F DB air entering indoor coil. 4.Rated indoor airflow for heating is the same as for cooling. AAHHRRII SSttaannddaarrdd 227700 RRaattiinngg CCoonnddiittiioonnss —(Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature 4 T W V 0 0 3 6 A 1 0 0 0 A A 6 22-1904-1H-EN Schematic Diagrams Figure 1.1.5–4.0 Ton Models 22-1904-1H-EN 7 Figure 2.5.0 Ton Models SScchheemmaattiicc DDiiaaggrraammss 8 22-1904-1H-EN Outline Drawing Model Base A B C D E F G H J K 4TTR4018L 2 730 (28–3/4) 724 (28–1/2) 651 (25–5/8)3/4 3/8 127 (5) 57 (2–1/4) 194 (7–5/8) 38 (1–1/2) 457 (18) 4TTR4024L 4TTR4025L 2 730 (28–3/4) 724 (28–1/2) 651 (25–5/8)3/4 3/8 127 (5) 57 (2–1/4) 194 (7–5/8) 38 (1–1/2) 457 (18) 4TTR4030L 4TTR4031L 3 730 (28–3/4) 829 (32–5/8) 756 (29–3/4)3/4 3/8 127 (5) 76 (3) 197 (7–3/4) 60 (2–3/8) 508 (20) 4TTR4036L 4TTR4037L 3 832 (32–3/4) 829 (32–5/8) 756 (29–3/4)3/4 3/8 127 (5) 76 (3) 197 (7–3/4) 60 (2–3/8) 508 (20) 4TTR4042L 4TTR4043L 4 741 (29–1/8) 946 (37–1/4) 870 (34–1/4)7/8 3/8 143 (5–5/8) 83 (3–1–4) 206 (8–1/8) 70 (2–3/4) 508 (20) 4TTR4048L 4 741 (29–1/8) 946 (37–1/4) 870 (34–1/4)7/8 3/8 143 (5–5/8) 83 (3–1–4) 206 (8–1/8) 70 (2–3/4) 508 (20) 4TTR4060L 4 943 (37–1/8) 946 (37–1/4) 870 (34–1/4)7/8 3/8 152 (6) 98 (3–7/8) 219 (8–5/8) 86 (3–3/8) 508 (20) 22-1904-1H-EN 9 Mechanical Specification Options GGeenneerraall The Outdoor Units are fully charged from the factory for up to 15 feet of piping.This unit is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. CCaassiinngg Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The corner panels are prepainted.All panels are subjected to our 1,000 hour salt spray test .The base is made of a CMBP-G30 weatherproof material to resist corrosion. RReeffrriiggeerraanntt CCoonnttrroollss Refrigeration system controls include condenser fan,compressor contactor and high pressure switch.High and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is standard.Some models may require field installation. CCoommpprreessssoorr The compressor features internal over temperature,pressure protection and total dipped hermetic motor.Other features include:Centrifugal oil pump and low vibration and noise. CCoonnddeennsseerr CCooiill The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. LLooww AAmmbbiieenntt CCoooolliinngg As manufactured,this system has a cooling capacity to 55°F.The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. TThheerrmmoossttaattss—Cooling only and heat/cooling (manual and automatic change over).Sub-base to match thermostat and locking thermostat cover. EEvvaappoorraattoorr DDeeffrroosstt CCoonnttrrooll —See Low Ambient Cooling. 10 22-1904-1H-EN NNootteess 22-1904-1H-EN 11 NNootteess Ingersoll Rand (NYSE:IR)advances the quality of life by creating comfortable,sustainable and efficient environments.Our people and our family of brands —including Club Car®,Ingersoll Rand®,Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 22-1904-1H-EN 27 Jan 2017 Supersedes 22-1904-1G-EN (March 2016)©2015 Ingersoll Rand |all rights reserved