Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 10 LA VILLA COURTFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: ``� �n' Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, v " \ Permit Number: Owner: WYNNE BUILDING CROP C� Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41442.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= {tz 5. Is this a worst case? Yes 11. Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c• NIA R= ft2 7. Windows(141.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 175 a. U-Factor. Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems k8tulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14. Heating systems kStulhr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1445.5 sqft.) Insulation Area £F:0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Total Proposed Modified Loads: 44.57 Glass/Floor Area: 0.098 PASS Total Baseline Loads: 45.19 1 hereby certify that the plans and specifications covered by Review of the plans and -iftE this calculation are in compliance with the Florida Energy specifications covered by this _4_0 Code. calculation indicates compliance with the Florida Energy Code. PREPAR D Y' Before construction is completed W ;1 DATE: -� -�D2 this building will be inspected for 10 i compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energya'�;jWF , OWNERI n1T !E- BUILDING OFFICIAL: DATE: � �\a DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/12/2021 12!02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block(Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/6dsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 fP 0 1 0 3SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft- — 0 1 0 6SIab-On-Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' — 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft. — 0 1 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft- ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft- _- 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft- 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 fit 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488W 0.1 Wood 10 Knee Wall (Vented) GREATIDINING 19 Blown 30 ft- 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below S ace P o 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 .2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int lnsuBEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 fit 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block- Int Lnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 _ 6 NEaSW Exterior Concrete Block - Int InsBEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block - Int InsINEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int Ins8EDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block- Int InsGIEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft. 0 0 0.4 0 12 SW=>NE Exterior Concrete Block- Int InSULAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int InstBREAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int Inst8REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft- 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft- WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation IM Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE�NW 7 Metal 4 NE�SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 Y 1.04 0.29 Y 1.04 0.29 Y 1.04 0.29 Y 1.11 0.27 Y 32.9 ft- 1 ft 0 in 1 ft 5 in Drapes/blinds 6.9 ft- 1 ft 0 in 1 ft 5 in None 24.0 ft- 6 It 0 in 1 ft 5 in None 37.5 ft 1 It 0 in 1 It 5 in None 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft- 315ft 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kStu/hr cfrn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT CIN RLF Heat Cool 1 Attic 6 175 ft= Attic 65IF Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablr(e ThermostaJanrDt:C'IN Fans:Cooling CFeb Mar Venting Jan Feb Mar Apr(reiling ay, rDC'I IrJO� rDO� ( Oct � Nov Dec ((X'l j ] [ ] X Apr [ May [ ] Jun [ ] Jul Aug [ ] Sep [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 It 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(81ts/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. ft' ft 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(81ts/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft' ft 0.3 ENTRY Default(811s/sq.ft. ft' ft 0.3 LAUNDRY Default 81bs/s .ft. ft. ft 0.3 GREATIDINING 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceilin soffit the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between windoWdoorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing g cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, mspemon or log wans Snail be In accordance with the provisions of IGG400. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame- Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 2 d. N1A R= ft2 5. Is this a worst rase? yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1446.00 f12 6. Conditioned floor area (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.04 101.25 ft2 12. Ducts, location 8. insulation level R ft2 SHGC: SHGC=0.29 a. Sup: Attic, Rat Attic, AH: Attic 6 175 b. U-Factor. Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. WA ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. r: N/A ft2 SHGC: SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): N/A ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 Credits (Performance method) None b. WA R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. �\ Builder Signature: Date: ' ^ Address of New Home:\� �{ \�\p� C Jy/FL Zip: �t�6 .3� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsofkm Project Summary o te: Enure House By QUICK CALCS, INC. 317 ST. LUCIE LN., FL PIERCE, FL 34946 Phxe: 772-466-6799 Fax 772-466-6796 Email: QUICKCA'LCS@AOL.COM Project Information For. WYNNE DEVELOPMENT CARLTON III,FT. PIERCE, FL Notes: \ Q� \ Q Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside cib 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Ducts 5900 Btuh Ducts 8919 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25591 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24418 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Btuh Ducts 2429 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(flz) 1602 1602 Equipment latent load 4493 Btuh Volume (le) 14827 14827 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 28912 Btuh Equiv.AVF (cfin) 94 49 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh@47°F 27 OF 1160 im 0.045 cfm/Btuh 0 in H2O Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A 030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Latentcooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfrn Airflowfaclor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrioaM5 Dtv 2021Jarv121294�36 Rigr[SJe&Uriwml201919.021 RSU08101AM Page 1 ...rt'\wrigltoft WADWYNNE-THE GRAND CARLiON.np Calc=M18 FrontDoorfaces: V wrightsoft Right4g) Worksheet '� Entire House °aba: QUICK CALLS, INC. BY 317 ST. LUCIE UN, Fr. PIERCE, FL 34946 Phone:772-466-6799FaK772466.6796 EmaiI:OUICNCALCS@AOL.COM 1 Room name ErNre House BEDROOM 2 Exposedwall 1762 ft 41.0 It II 3 Room f*ht 93 It d 8A ft heaUmol I 4 Room dimensars 14.0 x 18.0 ft 5 Room area 16015 F 2520 IF Ty Corshdon U-Vaue Or HTM Area mrnber I (BWhW-*F) (BIuhHF) or perimeter (ft) (BWh) perinretar (it) (BWh) Heat Cod Gros NIPS Heat Cool Gros NIPS Heat Cool 6 y}/ 13A-0ots 0.143 m 4A0 2.55 551 513 2055 1306 72 72 288 183 I—C 1Aclorn - 1270 - ne 3556 70A3 38 0 1344 25M 0 0 0 - - 0 13A-0as 0.143 w 440 255 128 87 348 221 0 0 0 . 0 IL---DG 1A,1w 1270 w 35M 7 25 20 0 711 1419 0 0 0 0 71 11D0 0390 se 10.92 1131 21 21 229 238 0 0 0 0 w 13A-4= 0.143 s 4A0 2$ 34 34 136 86 0 0 0 0 y/ 13A-4ocs 0.143 sw 4.00 2.55 416 390 1562 993 144 144 577 367 �C 1A-Mom 1270 sw 35M 70.95 6 0 213 426 0 0 0 0 1A-d= 1270 sw 3556 70.95 20 0 711 1419 0 0 0 0 13A4acs 0.143 nw 4A0 255 352 288 1151 732 112 88 354 225 tAclom 1270 w 35.56 4524 12 0 415 528 12 0 - 415 US 1Aatom 1270 rrw 3556 4524 12 0 427 w 12 0 - 427 543 4AS-2omd 0.770 rw 2155 36.90 41 0 880 1505 0 0 0 0 P 12C4)w OA91 255 128 120 120 306 164 0 0 0 0 C 16A30md OA32 090 232 1602 1602 1435 3715 252 252 226 585. F 22A-h11 0.9ag - 27.69 OAD 1602 176 4878 0 252 41 1135 0 6 o)AED e=rson 23 197 Erwelope loss/gain 16802 15970 3421 2627 12 a) hfiltrafion 28W 815 640 180 b) RoomeerNlaton 0 0 0 0 13 Inlerrel gains Oooupants@ 230 0 0 0 0 Applianmbifter 0 0 Subtolal(lines6b13) 19691 16785 4061 2807 Less exsmal load 0 0 0 0 Lestransfer 0 0 0 0 Redisbibufion 0 0 0 0 14 Subbial 19691 16785 4061 28D7 15 Dudloads 3D% 53% 59M 8919 30% 53% 1217 1491 Total room load 25591 25704 5278 4298 Air required(dm) 116D 1160 239 194 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. c -'- 67!Rr! 54n` 2021-, n1212A436 RigkSUfekJlhiversa1201919.021 RSU08101 ...rts\WnglWoft WACWYNNE-TIE GRAND CARLTONxW Calc=NW FrornDooriacas: N Page I T�11 F wrightsoft' RighWO Worksheet Job:Date:Entire House BY sr• QUICK CALCS, INC. 317ST.LUCIELN.,Fr.PIERCE,FL34946Pime:772-466-b799Fa T72-4666796 Email:QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 EVosedvsll 0 it 17A it 3 Room height 8.0 it heaVawl 8.0 ft IeaVoocl 4 5 Room dimereons Room area 7.0 x 9.0 It 63.0 T 7A x 17.0 It 1190 1F Ty ConsWction UAIWW Or HTM Arm (110) Load Area Load number (BIuMF-°F) (BWNftn or perimeter (it) (Bh31) or pedmetrr (1h (BWh) Heat Cool Gross N,PS Hear Cod Cvos NIPS Heat Cool 6 w 13AAM 0.143 re 4,00 255 0 0 0 0 0 0 0 0 �C y/ 1Acian 13A40rs 1270 0.143 m se 35M 4A0 70.43 2S5 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 - 0 0 IL—D(' tAcian 1270 se 3556 70.95 0 0 0 0 0 0 0 0 11 11D0 0390 se 10.92 1131 0 0 0 0 0 0 0 0 w 13AAo s 0.143 s OD 255 0 0 0 0 0 0s 0 ly �C 13A4a 1Actan 0.143 1270 w0 w 4A0 3556 2S5 70.95 0 0 0 0 0 0 0 0 136 6 130 0 621 213 331 426 �C 1AcIom 1270 w 35M 70.95 0 0 0 0 0 0 0 0 y/ 13A-4= - 0.143 w 400 255 0 0 0 0 0 0 0- - 0 �G cta 1An - 1270 w 35M 4524 0 0 0 0 0 0 0 0 fL—GG IA-dom 12M my 3556 4524 0 0 0 0 0 0 -. 0 0 4AS2orrd 0.770 my 2156 36.90 0 0 0 0 0 0 0 0 P 12C-Ow OD91 255 128 0 0 0 0 0 0 0 0 C 16A30md 0032 - 0.90 232 63 63 56 146 119 119 107 276 F 22A-V 0989 - 27.6.9 OM 63 0 0 0 119 17 471 0 6 c)AED e=rsim -13 55 Envelopeloss/on 56 133 1311 1087 12 a) Infiltration 0 0 265 75 b) Rmmvenfilation 0 0 0 0 13 Internal gains Omlpan%@ 230 0 0 0 0 Applian=bther 0 0 SubhFal(lirm61o13) 56 133 1577 1162 Lesextemalload 0 0 0 0 Les transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtdal 56 133 1577 1162 15 Ductloads 30% 53% 17 71 30%j 53% 472 618 Todd room load 73 204 2049 1780 Air required(dm) 3 9 93 80 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rk- wrightScwL— 2021JarF12120436 RigH-SLiLOL4iv 1201919.021RSU08101 Page ...rtslWdgtsoft FlVACiWYNNE-THE. GRAND CARL7oNAp Calc=MB Fror¢Doorfaoes N + Wrightson° Right-JO Worksheet Job: Entire House Mite: QUICK CALCS, INC. By. 317 ST.. LUCIE LN, FL PIERCE, FL 34946 Phve: 772-466-6799 Fax772-4666796 Email: QUIGCCALCS@AOL.COM 1 Room name WCHEN BATH 2 Elrposdvsll 0 a 5D ft 3 Room height 8.0 ft heatlmol 9.4 It heakool 4 Room dimensons 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 192A fl 45D T Ty Constuction U-value Or HTM Area Load Area number (BWhflF-T) (BWhAI� or perimeter (ft) (BWh) or perimeter (ft) (Bluh) Heat Cool Gros NIPS Heat Cool Gros WP5 Heat Cool 6 13AAors 0.143 re 460 255 0 0 0 0 47 47 188 120 1Aclom - 12M ne 35S6 70A3 0 0 0 0 0 0 0 - 0 13A-4ors 41143 se 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 as 35.56 70.95 0 0 0 0 0 0 0 0 11 11DO 0390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13AAors 0.143 s 460 2S5 0 0 0 0 0 0 0 0 y/ 13A4ocs 0.143 w 4.00 2S5 0 0 0 0 0 0 0 0 1Aclom 1270 sw 3556 70.95 0 0 0 0 0 0 0 0 ��CC tAdom 1270 sw 3556 70-% 0 0 0 0 0 0 0 0 13A4ocs 0.143 my 4A0 2S5 0 0 0 0 0 0 0 0 1A4Iom 1270 rw✓ 3556 4524 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3555 4524 0 0 0 0 0 0 0 0 4/S2omd 0.770 nw 21M 36.90 0 0 0 0 0 0 0 0 P 12C-Ow 0691 2S5 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 2.32 192 192 172 445 45 45 - - 40 104 F 22A-V 0.989 - 2769 0.00 192 0 0 0 45 5 138 0 6 c)AEDe¢ursion -39 -22 Envebpelossrgain 172 406 367 202 12 a) Mitralon 0 0 92 26 b) Roomven4lalion 0 0 0 0 13 trrtemal gain OoarpanbQ 230 0 0 0 0 Appllarxesbber 0 0 Sublomi (linesft 13) 172 406 459 228 Lese4amalload 0 01 0 0 Lestrarsfer 0 01 0 0 Redistribution 0 0 0 0 14 Subootal 172 406 459 228 15 Duct loads 3D% 53% 52 216 30% 53-4 137 121 Tohal mom bad 224 622 596 349 Airrequired (rfm) 10 28 27 i6 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2021Jarv121 Page3 A8k EGRAuteOUll-MN Lp Calc.=14 RSrorlDo Page ...rfs\Wngtlsoft l-NAC\WYNNE-iHE GRA1mCARLIONn.p CaIc=M18 RORDoorfaces: N i t wrightsoft` Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. ey. 317 ST.. LUCIE LN.,FT. PIERCE, FL 34946 Phore: 772A66-6799 Fac772466�6796 Email: OUiCKCALCS@AOL.COM 1 Roomname BEDROOV12 ENTRY 2 EVOSedwall 302 It 6.0 ft 3 Room height 8.0 It heavwd 8A It heaNmol 4 Room dimensons to x 1905 ft 6A x 10A ft 5 Room a 1905 r 60.0 1F Ty CaItIrmLon U-value Or HTM Area (fe.) Load Area (f?) Load camber (BUVIVO (BWh4F) or Wmeter M (BWh) or perimeter (ft) (BWh) Heat Cool Gros FLPS Heat Cool Gros WPS Heat Cool 6 lq/ 13A4= 0.143 ne 4A0 2.55 120 120 480 305 0 0 0 0 L—G 1Actpn 1270 ne 3555 70.43 0 0 0 0 0 0 0 - 0 13A4= 0.143 se 4.00 255 80 60 240 153 48 27 108 69 1A-dw 1270 se 35S6 70.95 20 0 711 1419 0 0 0 0 11 11DO 0.390 se 1022 11.31 0 0 0� 0 21 21 229 238 W 134-4o s 0.143 s 4A0 2S5 34 34 136 85 0 0 0 0 yl 13A4003 0.143 w 4110 2.55 8 8 32 2D 0 0 0 0 to -darn 1270 w 35M 70.95 0 0 0 0 0 0 0 0 %d= 1270 w 3556 70.95 0 0 0 0 0 0 0 0 13A4o s 0-143 rw 4110 2.55 0 0 0 0 0 0 0 0 1Ac'lom 1270 rw 3556 4524 0 0 0 0 0 0 0 0 IA-d= 1270 nw 3556 4524 0 0 0 0 0 0 0 0 OrSbmd 0.770 ma 2156 36.90 0 0 0 0 0 0 -0 0 P 12C-Ow OA91 2.55 128 0 0 0 0 0 0 0 0 C - 16A.90md OA32 - 0.90 2.32 191 191 171 442 60 60 54 139 F 22kV 0-%9 - 27.69 0.00 191 30 835 0 60 6 166 0 6 c)Amemirsion 209 41 Envelope lbs4gain 26M 2635 657 404 12 a) Mtation 472 133 94 26 b) Roomwrtilation I 1 0 0 1 0 0 13 hbm lgains O=pan6@ 230 0 0 0 0 ApplianoJoftrer 0 0 SubtoW(lines61o13) 3078 2768 651 430 Lesextemalload 0 0 0 0 Lewbansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3078 2768 651 430 15 Dudbads 300A 53% 922 1471 30% 53% 195 =1 Total room load 1 40W 4239 846 659 Airrequired(dm) 181 1911 38 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -..►.i+- htSulleOUriversal A21 RS 2021Jart1212A436 �rbiWrlgls7ftHACWYNNE-THEGRANDCAJ7L7ONxw Calc=MFortDoorfaresN Page +11- wrightsoft` Right�J® Worksheet Job: Entire House Dec QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phore:772-466-6799 Fax 772-46M796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATfDINWG 3 I Rheight 8.0 it 6.0 ft heav000l I 120 It 46A ft heavolool 4 5 Room dimensorls Room area 7.0 x 6.0 It 42.0 IF I 1.0 x 488.0 It 488.0 ft Ty Construction number U-value (BWh4F--°F) Or HTM (Bhrh4F) Area (ft� or penmeter (ft) Load (Btih) Area (ft' or perimeter (ft) Load (Btih) Heat Cool Gross NfPiS Heat Cool Gross NlP/S Heat Cool 6 V"cs 13A4o 1Ac1om 13A-4ocs 0.143 1270 0.143 ne ne se 4.00 35.% 4.00 2.55 70.43 2.55 0 0 0 0 0 0. 0 0 0 0 0 0 312 38 0 274 0 0 1098 1344 0 698 2662 0 11 tActom 11DO 1270 0.390 se se10.92 35.56 70.95 11.31 0 0 0� 01 0 0 0 0 0 0 0 0 0 0 0 0 W IN 13A4= 13A-4= 1Aciom 0.143 0.143 1270 s sv sv 4.00 4.00 35.56 2.55 2,55 70.95 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-dom 13A4c s 1Ao1am 1Actoan 4A5-2omd 1270 0.143 1270 1270 0.770 sw nw nw nw nw 35.56 4.00 35M 3556 21.56 70.95 2.55 4524 4524 36.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 0 0 41 0 199 0 0 0 0 798 0 0 880 0 507 0 0 1505 P C 12C-0sw 16A30md 0.091 0A32 - - 2.55 0.90 128 2.32 0 42 0 42 0 38 0 97 0 488 0 488 0 437 0 1132 F 22A-ml 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED exoaison -22 -597 Envelope loss/gain 396 198 5830 5908 12 a) Inliltaton 94 26 1077 304 b) Roomventlaton 0 0 0 0 13 Internal gains: Oovpant;@ 230 0 0 01 0 Appliances/other 1 0 0 Subtotal (lines 6 to 13) 4901 224 6907 6212 Les external load 01 0 0 0 14 Lestansfer Redistribution Subtotal 0 0 490 0 0 224 0 0 6907 0 0 6212 15 Dud loads 300/6 53% 147 119 301, 53% 2W0 3301 Total room load Air required(dm) 636 29 344 16 8977 407 9512 429 Calculafionsapproved bvACCAto meet all reauirementsof Manual J 8th Ed wrz9ft* ucw - 2021-Jar,1212:04:36 A&h ^^ RigkSute®Uriversal 201919.021 RSW8101 Pages ...ris\WngHsoft HVAMWYNNE-THE GRAND CARLION.np Calc=M18 Frorrt DoOrf2Qs:N wrightsofr Right-M Worksheet Ja1: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Prone: 772-466-6799 Fax 712466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOMS 2 EN)osed wall 25.0 ft 3 Room height 8.0 It heaVc of 4 Room dimensions 15.0 x 10.0 ft 5 Room area 150.0 ft' Ty Constructon U-value Or HTM Area (M Load I Area Load number (SWIVIF-'F) (BWh&) or perimeter (ft) (BWh) or penmetar Heat Cool Grog N/P/S Heat Cool Grog NIPS Heat Cool 6 V+/ 13A4ors 0.143 ne 4.00 2.55 0 0 0 0 �C 1Aclom 1270 ne 35.56 70.43 0 0 0 0 13A-4o6 0.143 se 4.00 2.55 c 0 0 0 1Aelom 1270 se 35.56 70.95 0 0 0 0 11 11 DO 0.390 se 10.92 11.31 0 0 0 0 W 13A-0as 0.143 s 4.00 2.55 0 0 0 y/ 13A-0ocs 0.143 sw 4.00 2S5 80 6pl 240 153 1Aclom 1270 sw 35.56 70.95 0 0 0 00 1A-clom 1270 sw 35.56 7095 20 0 711 1419 13AAc s 0.143 nw 4.p0 2.55 0 0 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 1Acicm 1270 nw 3556 4524 0 0 0 0 4A5-2omd 0.770 me 2156 3690 0 0 0 0 P 12C-0sw 0.091 - 2,55 128 120 120 306 154 C 16A30md OA32 - 090 232 150 150 134 348 F 224-WI 0.989 - 2T69 0.00 150 25 692 0 6 c)AEDexwrsion 296 Enselope low/gain 2084 2369 12 a) InfiltrAon +56 44 b) Room vemlafon 0 0 13 Internal gains: Oxupants@ 230 0 0 Applianoas/other 0 Subtotal(Iinw6W 13) 2240 2413 Lessememalload 0 0 Less transfer 0 01 Redistribution 0 0 14 Subtotal 2240 2413 15 Durtloads 30% 53% 671 1282 Total room load 2911 3695 Air required(cfm) 132 t67 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021-Ja,12129436 RigYtSuts(w Udversa120t9 i9.02t RSW8101 ...rtslWriglnsoft WADWYNNE-THE GRAND CARLTONnP CaIc=IVU8 FrortDoorfaces: N -ace6