HomeMy WebLinkAboutAPPROVED, 006 HVAC Energy Calcs Manual JsProject Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
ROCHE GUEST HOUSE
Street:
City, State, Zip: FORT PIERCE , FL ,
2744 BROCKSMITH ROAD
Permit Number:
Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of insulation.
Exposed earth in unvented crawl spaces shall be covered with a
Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub-floor, wall covering or ceiling
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope shall
be sealed to the finished surface.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be sealed
in a manner that is recommended by the manuf acturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software3/5/2021 6:36 AM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity with a
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation shall
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace walls.
Exterior walls adjacent to showers and tubs shall be
insulated.
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
a
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Project Summary Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
ROCHE GUEST HOUSEFor:
2744 BROCKSMITH ROAD, FORT PIERCE, FL
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90
Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15
Daily range M
Relative humidity %50
Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh25721 Struc ture Btuh18086
Ducts Btuh6024 Ducts Btuh8630
Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0
(none)(none)
Humidification Btuh0 Blower Btuh0
Piping Btuh0
Equipment load Btuh31745 Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load Btuh25380
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average
0Fireplaces Structure Btuh3067
Ducts Btuh2369
Central vent (0 cfm)Btuh0
CoolingHeating (none)
20622062Area (ft²)Equipment latent load Btuh5436
1855818558Volume (ft³)
Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh30816
Equiv. AVF (cfm)4999 Req. total capacity at 0.70 SHR ton3.0
Heating Equipment Summary Cooling Equipment Summary
Make Make Trane
Trade Trade TRANE
Model Cond 4TTR6036J1
AHRI ref Coil TEM4A0C37S31++TDR
AHRI ref 201763705
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input kW9.0 Sensible cooling Btuh24640
Heating output Btuh30754 Latent cooling Btuh10560
Temperature rise °F24 Total cooling Btuh35200
Actual air flow cfm1173 Actual air flow cfm1173
Air flow factor cfm/Btuh0.037 Air flow factor cfm/Btuh0.044
Static pressure in H2O1.00 Static pressure in H2O1.00
Space thermostat Load sensible heat ratio 0.83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name Entire House UTILITY RM
2 Exposed wall 198.0 ft 6.0 ft
3 Room height 9.0 ft 9.0 heat/coolft
4 Room dimensions ft12.0x6.0
5 Room area 2062.0 ft²72.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 279 249 997 545 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 15 0 273 225 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 15 0 273 160 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 504 424 1698 928 54 42 168 92
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 80 0 1457 2703 12 0 218 405
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 495 445 1781 973 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 50 0 912 803 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 504 409 1637 895 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 80 0 1458 2705 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 15 0 273 315 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 2062 2062 4388 6268 72 72 153 219
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 2062 198 7529 0 72 6 228 0
6 c) AED excursion 0 -32
Envelope loss/gain 22675 16520 768 684
12 a) Infiltration 3046 816 92 25
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 750 0
Subtotal (lines 6 to 13)25721 18086 860 709
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 31 41
14 Subtotal 25721 18086 891 750
15 Duct loads 23%48%6024 8630 23%48%209 358
Total room load 31745 26715 1100 1107
Air required (cfm)Air required (cfm)1173 1173 41 49
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name BATH 2 HALLWAY
2 Exposed wall 14.0 ft 0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft12.0x6.0 ft4.0x12.0
5 Room area 72.0 ft²48.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 54 54 216 118 0 0 0 0
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 72 52 208 114 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 20 0 366 322 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 0 0 0 0 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 72 72 153 219 48 48 102 146
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 72 14 532 0 48 0 0 0
6 c) AED excursion -12 -10
Envelope loss/gain 1475 760 102 136
12 a) Infiltration 215 58 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)1691 818 102 136
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 31 41 -102 -136
14 Subtotal 1721 859 0 0
15 Duct loads 23%48%403 410 23%48%0 0
Total room load 2125 1268 0 0
Air required (cfm)Air required (cfm)79 56 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 3
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name CLST 2 BEDROOM 2
2 Exposed wall 0 ft 5.0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft2.0x8.0 ft140.0x1.0
5 Room area 16.0 ft²140.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 45 30 120 66
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 15 0 273 225
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 0 0 0 0 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 16 16 34 49 140 140 298 426
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 16 0 0 0 140 5 190 0
6 c) AED excursion -3 -106
Envelope loss/gain 34 45 881 610
12 a) Infiltration 0 0 77 21
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 750
Subtotal (lines 6 to 13)34 45 958 1381
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution -34 -45 54 72
14 Subtotal 0 0 1013 1453
15 Duct loads 23%48%0 0 23%48%237 693
Total room load 0 0 1250 2146
Air required (cfm)Air required (cfm)0 0 46 94
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 4
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name OFFICE KITCHEN
2 Exposed wall 30.0 ft 24.0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft12.0x12.0 ft326.0x1.0
5 Room area 144.0 ft²326.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 108 93 372 203 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 15 0 273 160 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 216 165 662 362
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 51 0 923 1712
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 54 54 216 118 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 108 93 372 203 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 15 0 273 315 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 144 144 306 438 326 326 694 991
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 144 30 1141 0 326 24 913 0
6 c) AED excursion 41 -137
Envelope loss/gain 2954 1478 3191 2928
12 a) Infiltration 461 124 369 99
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)3416 1602 3560 3027
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 20 27
14 Subtotal 3416 1602 3581 3054
15 Duct loads 23%48%800 764 23%48%839 1457
Total room load 4216 2366 4419 4511
Air required (cfm)Air required (cfm)156 104 163 198
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 5
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name FOYER/LIVING RM PANTRY
2 Exposed wall 30.0 ft 0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft414.0x1.0 ft5.0x4.0
5 Room area 414.0 ft²20.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 54 54 216 118 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 216 166 664 363 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 50 0 912 1692 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 0 0 0 0 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 414 414 881 1259 20 20 43 61
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 414 30 1141 0 20 0 0 0
6 c) AED excursion 409 -4
Envelope loss/gain 3814 3841 43 56
12 a) Infiltration 461 124 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)4275 3965 43 56
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 4275 3965 43 56
15 Duct loads 23%48%1001 1892 23%48%10 27
Total room load 5277 5856 53 83
Air required (cfm)Air required (cfm)195 257 2 4
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 6
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name MASTER BEDROOM M WIC 1
2 Exposed wall 39.0 ft 9.0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft416.0x1.0 ft9.0x8.0
5 Room area 416.0 ft²72.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 171 141 565 308 81 81 324 177
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 30 0 546 481 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 180 150 601 328 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 30 0 546 1013 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 0 0 0 0 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 416 416 885 1265 72 72 153 219
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 416 39 1483 0 72 9 342 0
6 c) AED excursion 35 -31
Envelope loss/gain 4625 3430 820 365
12 a) Infiltration 600 161 138 37
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)5225 3591 958 402
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 5225 3591 958 402
15 Duct loads 23%48%1224 1713 23%48%224 192
Total room load 6449 5304 1183 594
Air required (cfm)Air required (cfm)238 233 44 26
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 7
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name M WIC 2 M TOILET
2 Exposed wall 0 ft 4.0 ft
3 Room height 9.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft62.0x1.0 ft4.0x8.0
5 Room area 62.0 ft²32.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 14.9914.99 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 nn 18.2018.20 10.6810.68 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ee 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 36 36 144 79
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 16.0316.03 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 33.7733.77 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 20.9720.97 0 0 0 0 0 0 0 0
CC 18A-10zd18A-10zd 0.0760.076 --2.132.13 3.043.04 62 62 132 188 32 32 68 97
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 62 0 0 0 32 4 152 0
6 c) AED excursion -13 -14
Envelope loss/gain 132 175 364 162
12 a) Infiltration 0 0 62 16
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)132 175 426 179
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 132 175 426 179
15 Duct loads 23%48%31 84 23%48%100 85
Total room load 163 259 526 264
Air required (cfm)Air required (cfm)6 11 19 12
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-26 11:04:30
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 8
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Right-J® Worksheet
Feb 26, 2021Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name M BATH
2 Exposed wall 37.0 ft
3 Room height 9.0 heat/coolft
4 Room dimensions ft228.0x1.0
5 Room area 228.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area Load
number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 13A-4ocs 0.143 n 4.00 2.19 72 72 288 158
.G 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0
.G 2 glazing, clr low-e 0.650 n 18.20 10.68 0 0 0 0
.W 13A-4ocs 0.143 e 4.00 2.19 180 163 651 356
11 G 2 glazing, clr low-e 0.650 e 18.20 33.77 17 0 315 585
W 13A-4ocs 0.143 s 4.00 2.19 81 81 324 177
G 2 glazing, clr low-e 0.650 s 18.20 16.03 0 0 0 0
W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0
G 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0
G 2 glazing, clr low-e 0.650 w 18.20 20.97 0 0 0 0
C 18A-10zd 0.076 -2.13 3.04 228 228 485 693
F 22A-tph 1.358 -38.02 0.00 228 37 1407 0
6 c) AED excursion -121
Envelope loss/gain 3471 1848
12 a) Infiltration 569 152
b) Room ventilation 0 0
13 Internal gains:Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13)4041 2001
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 4041 2001
15 Duct loads 23%48%946 955
Total room load 4987 2955
Air required (cfm)184 130
2021-Feb-26 11:04:34
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Job:Duct System Summary Feb 26, 2021Date:
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
ROCHE GUEST HOUSEFor:
2744 BROCKSMITH ROAD, FORT PIERCE, FL
CoolingHeating
External static pressure in H2O1.00in H2O1.00
Pressure losses in H2O0in H2O0
Available static pressure in H2O1.00in H2O1.00
Supply / return available pressure 0.500 / 0.500 in H2O in H2O0.500 / 0.500
Lowest friction rate in/100ft1.000in/100ft1.000
Actual air flow cfm1173cfm1173
Total effective length (TEL)ft218
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
st1115.024.7VlFx0x06.01.00056792125hBATH 2
st2115.017.9VlFx0x07.01.00094462146cBEDROOM 2
st2115.016.7VlFx0x07.01.000129982928cFOYER/LIVING RM
st3135.044.4VlFx0x07.01.000129982928cFOYER/LIVING RM-A
st1115.022.1VlFx0x07.01.00099822256cKITCHEN
st1115.030.4VlFx0x07.01.00099822256cKITCHEN-A
st4155.062.5VlFx0x07.01.0001301844987hM BATH
st4155.060.0VlFx0x04.01.0001219526hM TOILET
st4155.058.3VlFx0x05.01.00026441183hM WIC 1
st4155.060.5VlFx0x04.01.000116259cM WIC 2
st3135.042.1VlFx0x07.01.0001161193225hMASTER BEDROOM
st3135.050.1VlFx0x07.01.0001161193225hMASTER BEDROOM-A
st2115.019.7VlFx0x07.01.0001041564216hOFFICE
st3135.047.2VlFx0x04.01.0004283cPANTRY
st1115.030.4VlFx0x06.01.00049411107cUTILITY RM
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st4 Peak AVF 253 179 1.000 726 8.0 0x0 VinlFlx st3
st3 Peak AVF 591 544 1.000 753 12.0 0x0 VinlFlx st2
st2 Peak AVF 891 871 1.000 833 14.0 0x0 VinlFlx
st1 Peak AVF 283 302 1.000 555 10.0 0x0 VinlFlx
2021-Feb-26 11:04:34
Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2
E:\Documnets\Wrightsoft HVAC\ROCHE GUEST HOUSE.rup Calc = MJ8 Front Door fac es: W
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb1 0x 11730 1173 0 0 0 0 x0 0 VlFx
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 63/5/2021 6:35 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
ROCHE GUEST HOUSE
Street:
City, State, Zip: FORT PIERCE , FL ,
2744 BROCKSMITH ROAD
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
2062
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.65 174.83 ft²
SHGC=0.25
Sgl, U=0.65 80.00 ft²
SHGC=0.30
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2062.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1782.00 ft²
b. Frame - Wood, Adjacent R=13.0 216.00 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2062.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Propane Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:0.000 ft.
Area Weighted Average SHGC:0.266
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
2
(254.8 sqft.)
(1998.0 sqft.)
(2062.0 sqft.)
(2062.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
35.2 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
Tankless
EF: 0.590
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.124
Total Proposed Modified Loads:
Total Baseline Loads:
58.10
62.88 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
3-5-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
ROCHE GUEST HOUSE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2062
2
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
2744 BROCKSMITH R
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2062 18558
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 UTILITY RM 72 648 No 0 Yes Yes1 Yes
2 BATH 2 72 648 No 0 Yes Yes1 Yes
3 HALLWAY 48 432 No 0 Yes Yes1 No
4 CLST 2 16 144 No 0 Yes Yes1 No
5 BEDROOM 2 140 1260 No 0 1 Yes Yes1 Yes
6 OFFICE 144 1296 No 0 Yes Yes1 Yes
7 KITCHEN 326 2934 Yes 0 Yes Yes1 Yes
8 FOYER/LIVING RM 414 3726 No 0 Yes Yes1 Yes
9 PANTRY 20 180 No 0 Yes Yes1 No
10 MASTER BEDROO 416 3744 No 0 1 Yes Yes1 Yes
11 M WIC 1 72 648 No 0 Yes Yes1 Yes
12 M WIC 2 62 558 No 0 Yes Yes1 No
13 M TOILET 32 288 No 0 Yes Yes1 Yes
14 M BATH 228 2052 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 72 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -6 ft UTILITY RM
2 72 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -14 ft BATH 2
3 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -1 ft HALLWAY
4 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -1 ft CLST 2
3/5/2021 6:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
5 140 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -5 ft BEDROOM 2
6 144 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -30 ft OFFICE
7 326 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -24 ft KITCHEN
8 414 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -30 ft FOYER/LIVING R
9 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -1 ft PANTRY
10 416 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -39 ft MASTER BEDRO
11 72 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -9 ft M WIC 1
12 62 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -1 ft M WIC 2
13 32 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -4 ft M TOILET
14 228 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -37 ft M BATH
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Flat Concrete 2062 ft² Medium 0.3 20 0______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 No attic Unvented 2062 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 72 ft² 0.1 Wood______UTILITY RM Blown
2 Under Attic (Unvented)0 72 ft² 0.1 Wood______BATH 2 Blown
3 Under Attic (Unvented)0 48 ft² 0.1 Wood______HALLWAY Blown
4 Under Attic (Unvented)0 16 ft² 0.1 Wood______CLST 2 Blown
5 Under Attic (Unvented)0 140 ft² 0.1 Wood______BEDROOM 2 Blown
6 Under Attic (Unvented)0 144 ft² 0.1 Wood______OFFICE Blown
7 Under Attic (Unvented)0 326 ft² 0.1 Wood______KITCHEN Blown
8 Under Attic (Unvented)0 414 ft² 0.1 Wood______FOYER/LIVING R Blown
9 Under Attic (Unvented)0 20 ft² 0.1 Wood______PANTRY Blown
10 Under Attic (Unvented)0 416 ft² 0.1 Wood______MASTER BEDRO Blown
11 Under Attic (Unvented)0 72 ft² 0.1 Wood______M WIC 1 Blown
12 Under Attic (Unvented)0 62 ft² 0.1 Wood______M WIC 2 Blown
13 Under Attic (Unvented)0 32 ft² 0.1 Wood______M TOILET Blown
14 Under Attic (Unvented)0 228 ft² 0.1 Wood______M BATH Blown
3/5/2021 6:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0UTILITY RM 0006 9E Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
2 13 0UTILITY RM 00012 9N Frame - Wood 0.30.1Garage108.0 ft² ____
3 4.1 0BATH 2 0006 9E Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
4 4.1 0BATH 2 0008 9S Concrete Block - Int Insul 0.30Exterior72.0 ft² ____
5 13 0HALLWAY0004 9N Frame - Wood 0.30.1Garage36.0 ft² ____
6 13 0CLST 2 0002 9N Frame - Wood 0.30.1Garage18.0 ft² ____
7 4.1 0BEDROOM 2 0005 9N Concrete Block - Int Insul 0.30Exterior45.0 ft² ____
8 13 0BEDROOM 2 0006 9N Frame - Wood 0.30.1Garage54.0 ft² ____
9 4.1 0OFFICE00012 9N Concrete Block - Int Insul 0.30Exterior108.0 ft² ____
10 4.1 0OFFICE0006 9S Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
11 4.1 0OFFICE00012 9W Concrete Block - Int Insul 0.30Exterior108.0 ft² ____
12 4.1 0KITCHEN00024 9E Concrete Block - Int Insul 0.30Exterior216.0 ft² ____
13 4.1 0FOYER/LIVIN 0006 9N Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
14 4.1 0FOYER/LIVIN 00024 9W Concrete Block - Int Insul 0.30Exterior216.0 ft² ____
15 4.1 0MASTER BE 00019 9S Concrete Block - Int Insul 0.30Exterior171.0 ft² ____
16 4.1 0MASTER BE 00020 9W Concrete Block - Int Insul 0.30Exterior180.0 ft² ____
17 4.1 0M WIC 1 0009 9S Concrete Block - Int Insul 0.30Exterior81.0 ft² ____
18 4.1 0M TOILET 0004 9S Concrete Block - Int Insul 0.30Exterior36.0 ft² ____
19 4.1 0M BATH 0008 9N Concrete Block - Int Insul 0.30Exterior72.0 ft² ____
20 4.1 0M BATH 00020 9E Concrete Block - Int Insul 0.30Exterior180.0 ft² ____
21 4.1 0M BATH 0009 9S Concrete Block - Int Insul 0.30Exterior81.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 17.8 ft² None______N HALLWAY 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 0.65 0.25 12.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes1 Y
2 S Low-E Single 0.65 0.3 20.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes4 Y
3 N Low-E Single 0.65 0.25 15.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes7 Y
4 N Low-E Single 0.65 0.25 15.0 ft² 0 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y
5 W Low-E Single 0.65 0.25 15.0 ft² 0 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes11 Y
6 E Low-E Single 0.65 0.25 10.5 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y
7 E Low-E Single 0.65 0.3 40.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y
8 W Low-E Single 0.65 0.3 20.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y
9 W Low-E Single 0.65 0.25 30.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y
10 S Low-E Single 0.65 0.25 30.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y
11 W Low-E Single 0.65 0.25 30.0 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y
12 E Low-E Single 0.65 0.25 17.3 ft² 0 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y
3/5/2021 6:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 576 ft² 576 ft² 24 ft 9 ft 13______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1546.5 584.85.000286Wholehouse .0946159.29Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Propane 0.59 1 gal 62.3 gal 120 deg None______Tankless Exterior
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Default Leakage Garage (Default) c______1 1 (Default) c
3/5/2021 6:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT RM
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 ENTRY
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 W/D
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 GARAGE AREA
3/5/2021 6:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
2744 BROCKSMITH ROAD, FORT PIERCE, FL,
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft²)
New (From Plans)
Detached
1
2
No
2062
7. Windows**
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 174.83 ft²
SHGC=0.25
Sgl, U=0.65 80.00 ft²
SHGC=0.30
N/A f t ²
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2062.00 ft²
R= f t ²
R= f t ²
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior R=4.1 1782.00 ft²
b. Frame - Wood, Adjacent R=13.0 216.00 ft²
c. N/A R= f t ²
11. Ceiling Type and insulation level
a. Roof Deck (Unvented) R=20.0 2062.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts, location & insulation level
13. Cooling systems
14. Heating systems k B t u / h r
15. Hot water systems
a. Propane Cap: 1 gallons
EF: 0.59
b. Conservation features
None
d. N/A R= f t ²
Description Area
Insulation Area
Insulation Area
Insulation Area
Credits (Performance method)None
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
0.000 ft.
0.266
a. Electric Strip Heat 27.0 COP:1.00
a. Central Unit 35.2 SEER:16.00
k B t u / h r
Efficiency
Efficiency
a. Sup: Attic, Ret: Attic, AH: Garage 6 150
R f t ²
8. Skylights
a. U-Factor(AVG):
S H G C ( A V G ) :
Description Area
N/A
N/A
f t ²
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:
Address of New Home:City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
Page 1 of 1