HomeMy WebLinkAboutEnergy Code0-
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 13 Block 2 Waterstone 2508 CRGL
Builder Name: ADAMS HOMES
Street: 8109 Amalfi Circle
Permit Office:
City, State, Zip: Port Saint Lucie, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV020.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2623.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ft2
6. Conditioned floor area above grade (ft2) 2523
b. Knee Wall (Vented)
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(293.4 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 503.2
•
a. U-Factor: Dbl, U=0.33 117.49 ft2
"
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dtil, U=0.30 48.56 ft2
3
SHGC: SHang
Area Weighted Average Overhang Depth: 6.223 ft.
.
14Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons .
9. Floor Types (2523.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.32
PASS
Total Baseline Loads: 71.64
I hereby certify that the plans a ations covered .."'°
Revie f the plans and'iX'$T,
this calculation are in compli e e F orid rgy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
t
DATE: n�-0a-9n91 VVinn KPomany
this building will be inspected for
compliance with Section 553.908
,
* ` • k " :`
I hereby certify that this building, as designed, is in compliance
Florida Statutes..
^" �.•
with the Florida E Code.
G'O�}y� .
1
OWNER/AGENT-
BUILDING OFFICIAL:
DATE: v
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
= Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
Q ,envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
--Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/IC.0 380, is not greater than 0.060 Qn for whole house.
3/9/2021 9:58 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 13 Block 2 Waterstone 25 Bedrooms: 4
User Conditioned Area: 2523
Total Stories: 1
1 Worst Case: No,
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 13
Block/Subdivision: Waterstone
PlatBook:
Street: 8109 Amalfi Circle
County: St. Lucie
City, State, Zip: Port Saint Lucie ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ---- 0.44 0 0.56
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ft2 N N
CEILING
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2523 ft2 0.11 Wood
100 ft2 0.11 Wood
3/9/2021 9:58 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 IN1311T RUMMARY [_WFrKI ICT RFPPIRT
WALLS
Adjacent
a Ornt In Wall Type
Space
Cavity
Width
Height
Sheathing Framing Solar Below
1 SW Exterior
Concrete Block - Int Insul
Main
4.1
48
6
8 0
388.0 ft2
0
0 0.6
0
2 SE Exterior
Concrete Block - Int Insul
Main
4.1
37
2
8 0
297.3 ft2
0
0 0.6
0
3 NE Exterior
Concrete Block - Int Insul
Main
4.1
51
3
8 0
410.0 ft2
0
0 0.6
0
4 N Exterior
Concrete Block - Int Insul
Main
4.1
6
2
8 0
49.3 ft2
0
0 0.6
0
5 NW Exterior
Concrete Block - Int Insul
Main
4.1
37
6
8 0
300.0 ft2
0
0 0.6
0
6 - Garage
Frame - Wood
Main
13
34
0
8 0
272.0 ft2
0
0.23 0.01
0
7 NW Exterior
Concrete Block - Int Insul
Main
4.1
23
6
8 0
188.0 ft2
0
0 0.6
0
8 SW Exterior
Concrete Block - Int Insul
Main
4.1
8
6
8 0
68.0 ft2
0
0 0.6
0
9 NE Exterior
Concrete Block - Int Insul
Main
4.1
6
0
8 0
48.0 ft2
0
0 0.6
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE
Insulated
Main
None
.25
3
6 8
20 ft2
2 -
Wood
Main
None
.25
2
8
6 8
17.8 W
3 NE
Insulated
Main
None
.25
2
4
6 8
15.6 ft2-
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
V # Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW 1
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2 SW 1
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
'Exterior 5
3 SE 2
Vinyl Low-E Double
Yes
0.33
0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 SE 2
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 SE 2
Vinyl Low-E Double
Yes
0.33
0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
6 SE 2
Vinyl Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 NE 3
Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 NE 3
Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
9 N 4
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 NW 5
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
11 NW 5
Vinyl Low-E Double
Yes
0.33
0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 NW 7
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 NW 5
Vinyl Low-E Double
Yes
0.3
0.23
N
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
Exterior 5
GARAGE
# Floor
Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 620 ft2 620 ft2
64 ft
8 ft
1
3/9/2021 9:58 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPI IT SI IUUAPV r141:r1C1 icT QGOnOT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000391
2590.3 142.11 266.8 .1312
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing] HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
V # Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinJan Feb f X� Mar
Vent]n Jan Feb X Mar
Ceiling Fans:
Se
f APr IMay Jun Jul AuSeP
A r Ma X Jun ri
Jul rj
Au ri
[ A r May Jun JulAug Se [X]
Oct Nov
Oct Nov
Oct HX Nov
Dec
Dec
Dec
3/9/2021 9:58 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
E,JRM F{405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Main
3/9/2021 9:58 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
-:FORM'R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8109 Amalfi Circle, Port Saint Lucie, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ft2
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ft2
6. Conditioned floor area (ft2)
2523
b. Knee Wall (Vented)
R=19.0
100.00 ft2
7. Windows** Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
117.49 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main; AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
70.92 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.30
48.56 ft2
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.23
d. U-Factor: other (see details)
56.39 ft2
SHGC: other (see details)
14.. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
2
ft2
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2523.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: 1 Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of.the Florida Building Code, Energy Conservation, if not DEFAULT.
3/9/2021 9:58 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1